Universal Flow Monitors (UFM) Vortex Operating Manual

QUICK SETUP
PIPING
There are no additional steps beyond piping and wiring.
STARTUP WITH DISPLAY UNITS (PART NUMBER 78223)
Setup
At startup, digital display of 8.8.8 to show that all segments are present 8.8.8. Display shows that it is a totalizing unit. Tot Firmware version displayed. 4.66 Gallons/liters are the engineering units. G-L Total is shown at zero (unless the total was saved). 00.0
Resetting total
Push “Set” button to reset the total to zero. 00.0
Changing from Gallons to Liters
There are two buttons. “Menu” and “Set”. Menu changes the readings from Gallons to liters and back again.
If set to liters, there is an added decimal at the end 32.3. If set for gallons, no added decimal point. 8.53
2
Retaining the total at power off
Press “Menu” button and the “Set” button simultaneously until the LED blinks and release. Total will be retained. When power is turned on, the total will display as it was left. You must press “Set” to re-zero the display.
GENERAL SPECIFICATIONS
Maximum Operating Pressure: 200 PSIG (13.6 Bar) Minimum Operating Pressure: 10 PSI of back pressure is required for the formation of
vortices. Operating Temperature: 35 °F (2°C) to 210°F (99°C) Capacities: 1" = 50 GPM (190 LPM) Turndown Ratio: 10:1 standard Process Connections: Female NPT Wetted Parts: Polysulfone, PEEK and Viton Display: Blind or 3 digits. Enclosure Rating: Type 1, 3, 4, 12, 13, IP65 Power: 10 - 30 VDC @ 80 mA
Caution: The unit shall be supplied by a SELV (separated extra-low voltage) source in accordance with CSA Standard C22.2 No.1010.1-92 Annex H.
Environmental conditions: This device has been designed for use in Installation
Category I, pollution degree 4, at altitudes up to 2000
meters (6560 ft.), either indoors or outdoors as defined
in CSA Standard C22.2 No.1010.1-92.
*Viton® is a registered trademark for DuPont Performance Elastomers.
FCC statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Features
Engineering units LPM or GPM. It retains this setting when powered off.