Universal Flow Monitors (UFM) CPM Operating Manual

1
CPM manual
Vortex Shedding Water Add Flowmeter
PROPRIETARY NOTICE
Install in pipe making sure to orient IN port to flow supply.
10 pipe diameters distance is required upstream and 5 down for best accuracy.
Use proportional spacing if this much space is not available.
50 pipe diameters are required upstream as distance from a valve.
No use of Teflon tape please. (See detailed piping instructions.)
Attach cable assembly using grease (included) for added sealing around pins.
STARTUP FOR UNITS WITHOUT DISPLAY (PART NUMBER 73702)
QUICK SETUP
PIPING
There are no additional steps beyond piping and wiring.
STARTUP WITH DISPLAY UNITS (PART NUMBER 78223)
Setup
At startup, digital display of 8.8.8 to show that all segments are present 8.8.8. Display shows that it is a totalizing unit. Tot Firmware version displayed. 4.66 Gallons/liters are the engineering units. G-L Total is shown at zero (unless the total was saved). 00.0
Resetting total
Push “Set” button to reset the total to zero. 00.0
Changing from Gallons to Liters
There are two buttons. “Menu” and “Set”. Menu changes the readings from Gallons to liters and back again.
If set to liters, there is an added decimal at the end 32.3. If set for gallons, no added decimal point. 8.53