Unitron UTMD, UTMD-AL, UTMD-MB Installation Manual

22-UTMD-00
-
-
I N S T A L L A T I O N
M A N U A L
TOUCHMASTER DELTA™ SIREN/PA SYSTEM
UTMD
UTMD-MB
-AL
FS UNITROL 1108 RAYMOND WAY ANAHEIM, CA. 92801 • 1-714-871-3336 • FAX 1-714-871-3418
1
LIMITED WARRANTY
LIMITED WARRANTY
F S UNI TR OL , a unit of Federal Sign al Corporation, warrants each
FS UNITROL
new product to be free from defects in material and workmanship under normal use and service for a period of five year on parts replacements and one year labor from the date of purchase.
During this warranty period, the obligation of repairing or replacing, as
products which, after examination by Unitrol, is found to be defective in material and/or workmanship.
UNITROL will warrant any unit that is delivered, prepaid, to the
UNITROL
U NI T R O L f actory or designated authorized warranty service center for
UNITROL
examination within the warranty period. If such examination reveals a defect in material and/or workmanship,
necessary repairs under warranty.
This warranty does not cover travel exp enses, the cost of specialized equipment for gaining access to the product, or labor charges for removal and re-installation of the product. Lamps, flash tubes or batteries are not covered under warranty.
Warranty will not be extended to any unit that has been subjected to abuse, misuse, improper installation, or to one that has been inadequately maintained. Warranty does not apply to units that have problems relating to service or modification at any facility other than
the
UNITROL factory or authorized warranty service centers.
UNITROL
THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL UNITROL BE LIABLE FOR ANY
U NITROL may elect, any part or par ts of such
UNITROL
UNI TR OL is limited to
UNITROL
UNITROL will complete the
UNITROL
2
T A B L E O F C O N T E N T S
SECTION TITLE PAGE
I GENERAL INFORMATION…………………… 4
II SPECIFICATIONS……………………………… 4
III SAFETY MESSAGE TO INSTALLERS……….. 5
IV INSTALLATION……………………………….. 6-8
V LATCHING ACCESS ORY SWITCHES……….. 8
VI SAFETY MESSAGE TO OPERATORS………. 10
VII SERVICE AND MAINTENANCE……………... 11
3
SECTION I GENERAL INFORMATION
SECTION I
GENERAL INFORMATION
STANDARD SIREN SOUNDS
The TM DELTA is shipped with (5) operational si ren sounds: MAN: manu al WAIL WAIL: WAIL plus 5-sec ond YELP, or WAIL/YELP/Ultra HI-LO, (sweep), all by pressing the horn
ring once.
YELP: YELP plus 5-second FUTURA, or YELP/FUTURA/Ultra HI-LO (sweep), All by pressing the
horn ring once.
SECTION II
SPECIFICATIONS
STANDARD SIREN SWEEP SOUNDS
When horn ring is activa ted and the mode switch is in:
WAIL: WAIL/YELP/ULTRA HI-LO YELP: YELP/FUTURA/ULTRA HI-LO
Height Width Depth Ship Input Operating Standby Weight Voltage Current Current In. Cm. In. Cm. In. Cm. Lbs. Kg.
2.4 6.2 6.5 16.5 6.0 15.2 5.0 2.3 11 – 16VCD 0-205 amps 0 amps
Input voltage__________________________ _________11-16VDC Standby current_________________________________0 amps Operating c urrent (amplifier)______________________7.5 amps (one 100 watt s pea ker) 14 amps (two 100 watt speakers) Operating temperature range______________________-30°C to 65°C Frequency range_________________________ _______500Hz to 1650 Hz Nominal cycle range Wail Yelp Nominal voltage output__________________________64V pea k-to-peak (siren tones ) Audio frequenc y response________________________300 Hz to 3,000 Hz (+ Input Impedance ________________________________4,000 ohms (nominal) Current ratings: Slide bar outputs (progressive): Position 1___________________________________20 amps Position 2___________________________________20 amps Position 3___________________________________20 amps Progressive total___________________ ___________60 amps
____________________ ___________________11 cycles per minute ____________________ ___________________240 cycles per minute
3 dB )
Push-button swi tches__________________________20 amps each
4
Loading...