Unitron Stride P 500, Stride P 700, Stride P Dura Pro, Stride P Dura 800, Stride P Dura 700 User Manual

...
Stride behind-the-ear (BTE) hearing aid guide
Thank you
Thank you for choosing these hearing aids.
We care deeply about people with hearing loss. We work closely with hearing healthcare professionals to make advanced, purpose­driven solutions available to everyone. Because hearing matters.
Your hearing aids
Hearing healthcare professional: _______________
___________________________________________
Telephone: _________________________________
Model: ____________________________________
This user guide applies to the following models:
Year of introduction: 2015 Stride™ P Pro Stride™ P 800 Stride™ P 700 Stride™ P 600 Stride™ P 500
Year of introduction: 2016 Stride™ M Pro Stride™ M 800 Stride™ M 700 Stride™ M 600 Stride™ M 500
Stride™ P Dura Pro Stride™ P Dura 800 Stride™ P Dura 700 Stride™ P Dura 600 Stride™ P Dura 500
Serial number: ______________________________
Replacement batteries: Size 13 Size 312
Warranty: __________________________________
Program 1 is for: ____________________________
Program 2 is for: ____________________________
Program 3 is for: ____________________________
Program 4 is for: ____________________________
Date of purchase: ____________________________
Quick reference
Table of contents
Low battery
Battery size On/O
warning
2 beeps every 30 minutes
312
13
On
Changing batteries
Stride M Stride P Dura Stride P
Plus (+) signsBattery symbol Battery symbol
Push button Rocker switch
switching programs volume control
volume control
O
Your hearing aids at a glance ..................................................... 2
Warnings .................................................................................... 6
Putting your hearing aids on your ears..................................... 10
Turning your hearingaids onando ........................................12
Batter y information ...................................................................13
Tinnitus masker ....................................................................... 16
Operating instructions ..............................................................19
Using the telephone ................................................................. 25
Protecting your hearing aids .................................................... 28
Cleaning your hearing aids ....................................................... 29
Accessories .............................................................................. 33
Assistive listening devices ....................................................... 34
Troubleshooting guide ............................................................. 36
Warning to hearing aid dispensers (tocomplywith the U.S.
Food and Drug Administration (FDA) regulations) ...................41
Information and explanation of symbols ................................. 44
Compliance information ........................................................... 46
Patient feedback ...................................................................... 48
Additional notes ....................................................................... 49
Your hearing aids at a glance
1 Earhook - your custom made earmold attaches
to your hearing aids using the earhook
2 Microphone - sound enters your hearing aids
through the microphones. Microphone shield ­protects microphones from dirt & debris
3 Push button - switches between listening
programs or changes the volume level, depending on your customized tting
4 Rocker switch - controls the volume level
5 Battery door (on & o) - close the door to turn on
your hearing aids, open the door all the way to turn o your hearing aid or to change the battery
6 Tubing - part of the earmold that attaches it to
the earhook
7 Earmold - allows the sound to pass from the
hearing aids to the ear and holds the hearing aids in place
8 Slim tube - sound travels down the slim tube to
the ear canal
9 Dome - holds the slim tube in place in your ear
canal
2 3
10 Retention piece - helps prevent the dome and
slim tube from moving out of the ear canal
Stride M BTE hearing aids
2 3
2
5
2 3
2
5
1
6
7
8
9
10
Stride P Dura BTE hearing aids
Stride P BTE hearing aids
2 3
2
5
2 3
2
5
4 5
1
6
7
8
9
10
2 3
2
4
5
2 3
2
4
5
1
6
7
8
9
10
Warnings
The intended use of hearing aids is to
amplify and transmit sound to the ears and hereby compensate for impaired hearing.
The hearing aids (specially programmed for
each hearing loss) must only be used by the intended person. They should not be used by any other person as they could damage hearing.
Hearing aids should only be used as
directed by your physician or hearing healthcare professional.
Hearing aids will not restore normal
hearing and will not prevent or improve a hearing impairment resulting from organic conditions.
Do not use your hearing aids in explosion
hazard areas.
Allergic reactions to hearing aids are unlikely.
However, if you experience itching, redness, soreness, inflammation or a burning sensation in or around your ears, inform
6 7
your hearing healthcare professional and contact your physician.
In the unlikely case that any parts remain
in the ear canal aer the removal of the hearing aid, contact a physician immediately.
Remove your hearing aids for CT and
MRI scans or for other electromagnetic procedures.
Special care should be exercised in wearing
hearing aids when maximum sound pressure levels exceed 132 decibels. There may be a risk of impairing your remaining hearing. Speak with your hearing healthcare professional to ensure the maximum output of your hearing aids is suitable for your particular hearing loss.
Magnet and battery warnings
Never leave hearing aids, batteries or
magnets where small children and pets can reach them. Never put hearing aids or batteries in your mouth. If a hearing aid or battery is swallowed, call a physician immediately.
The magnet may aect some medical
devices or electronic systems. Always keep the magnet (or the telephone equipped with the magnet) at least 30 cm (12”) away from pacemakers, credit cards or other magnetically sensitive devices.
Precautions
The use of hearing aids is only part of
hearing rehabilitation; auditory training and lip reading instruction may be required as well.
In most cases, infrequent use of hearing
aids does not provide full benet. Once you have become accustomed to your hearing aids, wear your hearing aids everyday all day.
Your hearing aids use the most modern
components to provide the best possible sound quality in every listening situation. However, communication devices such as digital cell phones can create interference (a buzzing sound) in hearing aids. If you
experience interference from a cell phone being used close by, you can minimize this interference in a number of ways. Switch your hearing aids to another program, turn your head in a dierent direction or locate the cell phone and move away from it.
Too high distortion during dialing or
phoning may mean that the phone handset is stressed by the magnet. To avoid any damage, please move the magnet to another place on the telephone receiver.
Note to hearing healthcare professional
Domes should never be tted on patients
with perforated eardrums, exposed middle ear cavities, or surgically altered ear canals. In the case of such a condition, we recommend to use a customized earmold.
Labeling
The serial number and year of manufacture are
located inside the battery door.
8 9
Putting your hearing aids on your ears
Your hearing aids may be color-coded with a
small dot on the battery door: red = right ear; blue = le ear.
Hearing aids with earmolds
1. Hold the earmold between your thumb and index nger, with the opening facing toward your ear canal and the hearing aid resting above your ear.
2. Carefully insert the earmold in your ear. You may need to twist it slightly to the back. The earmold should t into your ear snugly and comfortably. Gently pull down and back on your earlobe to help you insert the earmold into your ear canal more easily.
3. Place the hearing aid over the top of your ear.
10 11
1.
2.
3.
Hearing aids with domes
1. Place the hearing aid over the top of your ear. The slim tube should lie flush against your head and not stick out.
2. Hold the slim tube where it attaches to the dome and gently push the dome into your ear canal.
3. Place the retention piece in your ear so it rests at the bottom of the opening of your ear canal.
1.
2.
3.
Turning your hearingaids onando
The battery door acts as an on and o switch.
1. On: Close the
1.
battery door fully.
Note: It may
take ve seconds before the hearing aid turns on. Your hearing healthcare professional can increase the start up delay if required.
2.
2. O: Open the battery door.
Note: When turning your hearing aid on and o
while it is on the ear, grasp the top and bottom of the device with your index nger and thumb. Use your thumb to open and close the battery door.
1.
2.
Battery information
Low battery warning
Two long beeps indicate the hearing aid battery
is low. Aer the low battery warning, sounds may not be as clear. This is normal and can be xed by changing the batteries.
If you can’t hear the low battery warning, your hearing healthcare professional can change its pitch or loudness. If you prefer, it can be turned o entirely.
Your hearing aids are designed to generate a
low battery warning every 30 minutes until you change the batteries, but depending on the condition of the batteries, they may die before another low battery warning occurs. Therefore, it is recommended that the batteries are replaced as soon as possible once you hear the low battery warning.
12 13
Replacing the battery
1. Gently swing out the battery door with your ngernail.
2. Push the battery with your thumb and index nger towards the open side, and remove or pull the battery straight out, depending on your style of hearing aid.
3. Insert the new battery into the battery compartment with the plus (+) sign on the battery facing the same way as the
1. 1.
2. 2.
3.
3.
4. 4.
battery symbol on the battery door. This will ensure that the battery door closes properly.
Note: If the battery is inserted incorrectly, the
hearing aid will not turn on.
4. Close the battery door.
Note: There is a tamper-proof batter y door
option for these hearing aids. Please see your hearing healthcare professional for further information.
Caring for batteries
Always discard batteries in a safe and
environmentally friendly way.
To prolong battery life, remember to turn
your hearing aids o when not in use, especially when asleep.
Remove the batteries and keep the battery
door open while hearing aids are not being worn, especially when asleep. This will allow internal moisture to evaporate.
14 15
Tinnitus masker
Tinnitus masker uses broadband noise to
provide temporary relief of tinnitus.
Tinnitus masker warnings
The tinnitus masker is a broadband sound
generator. It provides a means of sound enrichment therapy that can be used as part of a personalized tinnitus management program to provide temporary relief from tinnitus.
The underlying principle of sound
enrichment is to provide supplementary noise stimulation which can help defocus your attention from your tinnitus and avoid negative reactions. Sound enrichment, coupled with instructional counseling, is an established approach to managing tinnitus.
Air conduction hearing aids with the
tinnitus masker are to be tted by a hearing healthcare professional familiar with the diagnosis and management of tinnitus.
Should you develop any side eects
while using the tinnitus masker, such as headaches, nausea, dizziness or heart palpitations or experience a decrease in auditory function such as decreased loudness tolerance, worsening of tinnitus, or speech not as clear, you should discontinue use of the device and seek medical attention.
The volume of the tinnitus masker can be
set to a level which could lead to permanent hearing damage when used for a prolonged period of time. Should the tinnitus masker be set to such a level in your hearing aid, your hearing healthcare professional will advise you of the maximum amount of time per day you should use the tinnitus masker.
The tinnitus masker should never be used at
uncomfortable levels.
16 17
Important information
The tinnitus masker generates sounds that are
used as part of your personalized temporary tinnitus management program to provide relief from tinnitus. It should always be used as prescribed by a hearing healthcare professional who is familiar with the diagnosis and treatment of tinnitus.
Good health practice requires that a person
reporting tinnitus have a medical evaluation by a licensed ear physician before using a sound generator. The purpose of such an evaluation is to ensure that medically treatable conditions, which may be causing tinnitus, are identied and treated prior to using a sound generator.
The tinnitus masker is intended for adults 18
years of age or older who have both hearing loss and tinnitus.
Operating instructions
Your hearing aids may come with two controls that allow you to further adjust them – a rocker switch and a push button.
Rocker switch
The rocker switch on your hearing aids
is a volume control.
Volume control
Press up to increase volume
Press down to decrease volume
As you change the volume level, your hearing aids will beep.
Volume setting Beeps
Suggested volume level 1 beep
Turning volume up short beep
Turning volume down short beep
Maximum volume level 2 beeps
Minimum volume level 2 beeps
18 19
Push button
The push button on your hearing
aids can be either a program control, a volume control or a
combination of both.
Program control
If your push button is a program control, each time you push the button, you will move to a new hearing aid program.
Your hearing aids beep to indicate which
program you are in.
Volume control
If your push button has been congured as a volume control, either:
Push the button on your right hearing aid to
increase the volume, and
Push the button on your le hearing aid to
decrease the volume
or:
Push the button to step through your volume
levels
As you change the volume control, your hearing
Program setting Beeps
Program 1 (e.g. automatic program) 1 beep
Program 2 (e.g. speech in noise) 2 beeps
Program 3 (e.g. easy-t/telephone) 3 beeps
Program 4 (e.g. music) 4 beeps
Easy-t/telephone short melody
DuoLink (if enabled) Opposite ear beeps
the same as side being adjusted
aids will beep.
Volume setting Beeps
Suggested volume level 1 beep
Turning volume up short beep
Turning volume down short beep
Maximum volume level 2 beeps
Minimum volume level 2 beeps
Please see the front of this booklet for a listing of your personalized programs.
20 21
Program/volume control push button
If your hearing healthcare professional has congured one hearing aid to be a program control and the other hearing aid to be a volume control:
Push the button on your right / le
hearing aid to access your dierent programs, and
Push the button on your right / le
hearing aid to step through your volume levels
Tinnitus masker
If your hearing healthcare professional has congured both a tinnitus masker program and a volume control, you can adjust the tinnitus masker level while you are in the tinnitus masker program. To adjust the noise level, either:
Rocker switch
Push up on the rocker switch to increase
the tinnitus masker, and
Push down on the rocker switch to
decrease the tinnitus masker
Push button (right/le)
Push the button on your right hearing aid
to increase the tinnitus masker, and
Push the button on your le hearing aid to
decrease the tinnitus masker
Push button (steps)
Push the button to step through your
tinnitus masker volume levels
As you change the level, your hearing aids will beep.
22 23
DuoLink
If DuoLink is enabled, when you change the volume or program settings on one hearing aid, the other one changes as well. DuoLink works for both the push button and the rocker switch.
For example, if your push button is congured as a program control and DuoLink is enabled, when you push the button on one hearing aid, the program will change on both hearing aids.
Using the telephone
Push button
Your hearing healthcare professional may have set up a phone program on your hearing aids that you can access using the push button or optional remote control.
Easy-t
Your hearing aids may also have a telephone feature, which automatically switches to a dedicated telephone program when a receiver is brought close to one of your hearing aids. You will hear a short melody when you switch to the easy-t program. When the receiver is moved away from the hearing aid it will automatically return to the previous listening program.
If your hearing aid doesn’t automatically switch to the easy-t program when a receiver is held to your ear, you may need to attach an easy-t magnet to your telephone. The magnet is designed to strengthen the magnetic eld at the earpiece of the telephone.
24 25
To attach the optional magnet:
1.
1. Clean the telephone receiver. Hold the magnet near the “listening end” of your telephone receiver and release it. The magnet will flip to the
2.
appropriate side and seek the optimal position on the telephone receiver.
2. Place the double-sided tape
3.
in this optimal position on the telephone receiver.
3. Attach the magnet to the tape.
Your hearing healthcare professional may also
have set up a phone program that you can access through your optional remote control.
Binaural Phone
The Binaural Phone feature allows you to hold a
phone to one ear and hear the sound clearly in both ears. No accessories are required.
Binaural Phone is available in your hearing aids through:
Push button Easy-t
If your hearing aids are congured to work with the wireless uDirect™ or uStream streamers, you might benet from a Bluetooth® hands-free option. Refer to the uDirect or uStream user guide for more information.
26 27
Protecting your hearing aids
Open the battery door when not in use.
Always remove your hearing aids when
using hair care products. The hearing aids can become clogged and cease to function properly.
Do not wear your hearing aids in the bath or
shower or immerse them in water.
If your hearing aids do become wet, do not
attempt to dry them in an oven or microwave. Do not adjust any controls. Open the battery doors immediately, and allow your hearing aids to dry naturally for 24 hours.
Protect your hearing aids from excessive heat
(hair dryer, vehicle glove box or dashboard).
Ensure you do not twist or squeeze the wire
when your hearing aids are placed in their case.
Regular use of a dehumidier, such as a Dri-Aid
kit, can help prevent corrosion and prolong the life of your hearing aids.
Do not drop your hearing aids or knock them
Cleaning your hearing aids
Use a so cloth to clean your hearing aid at the end of each day, and place it in its case with the battery door open to allow moisture to evaporate.
Ear wax is natural and common. Ensuring your
hearing aids are free of ear wax is an important step in your daily cleaning and maintenance routine.
Never use alcohol to clean your hearing aids,
earmolds or domes.
Do not use sharp tools to dislodge ear wax.
Sticking household items into your hearing aids
or earmolds can seriously damage them.
Cleaning your earmolds and earpieces
Clean the earmold and the outside of the earhook with a damp cloth at the end of each day. Avoid getting any water in and around the hearing aids.
Do not use alcohol to clean your earmolds.
against hard surfaces.
28 29
If the earmolds become plugged, clear the opening with a wax loop or pipe cleaner.
If your physician prescribes eardrops, clean any moisture that may get into the earmolds or tubing to prevent plugging.
If the earmolds require further cleaning:
1. Disconnect the plastic tube from the hook of the hearing aid, by holding the hearing aid in one hand and gently pulling the tubing away from the earhook.
2. Wash only the earmolds and tubing in warm water with a mild soap.
3. Rinse them with cool water and dry overnight.
4. Make sure the earmold tubes are completely dry. Reconnect them to the earhook on your hearing aid by sliding the tubing back on to the earhook. Use of a hearing aid blower can assist with removing moisture/debris from the tube. See your hearing healthcare
professional for more information.
Cleaning your slim tubes and domes
You should have the slim tubes and domes replaced by your hearing healthcare professional approximately every three to six months or when they become sti, brittle, or discolored.
Clean the outside of the domes at the end of each day with a damp cloth. Avoid getting any water in and around the hearing aids.
You should also clean the slim tubes periodically, with the cleaning pin provided, when you begin to notice debris in and around the tubes.
1. Hold the slim tube in one hand and the hearing aid in the other hand.
2. Gently turn the hearing aid until it detaches from the slim tube.
3. Use a damp cloth to clean the outside of the slim tube and dome.
4. Remove the dome from the slim tube by pulling gently, before cleaning the slim tube.
30 31
5. Using the black cleaning pin provided in the kit, gently insert the cleaning pin where the slim tube attaches to the hearing aid and push the pin all the way through the tube.
Note: The slim tubes and domes should never
be rinsed or submerged in water as water drops may become lodged in the tube, block sound or damage the electrical components of the hearing aid.
6. Once the slim tube has been cleaned, reattach it by gently turning the hearing aid onto the slim tube.
7. Reattach the dome to the slim tube by gently pushing it back onto the threading at the end of the tube. You will feel the dome click onto the ridges of the slim tube, and you won’t be able to push it any further.
Accessories
The uDirect, uStream, uMic,™ uT V™ and a remote
control are optional accessories that may be available for your hearing aids.
uDirect , uStream and uTV 
uDirect and uStream are streamers that provide easy, hands-free access to Bluetooth enabled devices, such as mobile phones. They can provide remote control functions to adjust your hearing aids for increased listening comfort. uDirect also has a wired audio jack to plug in devices like MP3 players.
uTV is used with a streamer (uDirect or uStream) to send sound from your TV directly to your hearing aids. The uTV can also transmit sound from stereo systems, computers and other audio sources.
For more information on using the uDirect, uStream or uTV, please see the user guide for that accessory. For information on how to get a streamer or uTV accessory, please contact your hearing healthcare professional.
32 33
uMic
uMic is a personal wireless microphone system that lets you hear conversations better in noisy environments, through either uStream or uDirect.
Remote control
Your hearing aids may also come with an
optional remote control which allows you to switch between dierent listening programs, and change your volume settings.
Assistive listening devices
Listening in public places
Telecoils pick up electromagnetic energy and
convert it into sound. Your hearing aid’s telecoil option can help you listen in public places equipped with telecoil compatible assistive listening devices such as a loop system. When you see this symbol, a loop system is present and it is compatible with your hearing aid. Please contact your
hearing healthcare professional for more information on loop systems.
Connecting to external audio sources
Your hearing aids may have a direct audio input
(DAI) to connect to other audio sources, such
as a stereo or television, using an FM system or a cable. The uDirect, an optional wireless accessory, also has a DAI jack.
When your hearing aids detect a DAI signal, they switch to your easy-DAI program automatically. A short melody indicates that easy-DAI is active. When you disconnect the DAI, your hearing aids return to the previous program automatically.
Ask your hearing healthcare professional for information about the DAI system and a connector cord.
34 35
Troubleshooting guide
Cause Possible remedy
No sound
Not turned on Turn on
Low/dead battery Replace battery
Poor battery contact Consult your hearing
healthcare professional
Battery upside down Insert battery plus (+) side
up
Custom shells/domes blocked with ear wax
Plugged microphone shield
Clean custom shells/ domes. See “Cleaning your hearing aids.” Consult your hearing healthcare professional
Consult your hearing healthcare professional
Cause Possible remedy
Not loud enough
Low volume Turn up volume; see hearing
healthcare professional for models without a manual volume control or if problem persists
Low battery Replace battery
Custom shells/domes not inserted properly
Change in hearing Consult your hearing
Custom shells/domes blocked with ear wax
Plugged microphone shield
See “Putting your hearing aids on your ears.” Remove and reinsert carefully
healthcare professional
Clean custom shells/domes. See “Cleaning your hearing aids.” Consult your hearing healthcare professional
Consult your hearing healthcare professional
36 37
Cause Possible remedy
Intermittent
Low battery Replace battery
Dirty battery contact Consult your hearing
healthcare professional
Two long beeps
Low battery Replace battery
Whistling
Custom shells/domes not inserted properly
Hand/clothing near ear Move hand/clothing away
Poorly tting custom shells/domes
See “Putting your hearing aids on your ears.” Remove and reinsert carefully
from ear
Consult your hearing healthcare professional
Cause Possible remedy
Not clear, distorted
Poorly tting custom shells/domes
Custom shells/ domes blocked with ear wax
Low battery Replace battery
Plugged microphone shield
Consult your hearing healthcare professional
Clean custom shells/domes. See “Cleaning your hearing aids.” Consult your hearing healthcare professional
Consult your hearing healthcare professional
Custom shells/domes falling out of ear
Poorly tting custom shells/domes
Custom shells/domes not inserted properly
Consult your hearing healthcare professional
See “Putting your hearing aids on your ears.” Remove and reinsert carefully
38 39
Cause Possible remedy
Weak on the telephone
Telephone not
positioned properly
Move telephone receiver around ear for clearer signal. See “Using the telephone”
Hearing aid requires adjustment
Consult your hearing healthcare professional
For any problems not listed in the guide, contact your hearing healthcare professional.
Warning to hearing aid dispensers
(tocomplywith the U.S. Food and Drug
Administration (FDA) regulations)
A hearing aid dispenser should advise a prospective hearing aid user to consult promptly with a licensed physician (preferably an ear specialist) before dispensing a hearing aid if the hearing aid dispenser determines through inquiry, actual observation, or review of any other available information concerning the prospective user, that the prospective user has any of the following conditions: (i) Visible congenital or traumatic deformity of the ear. (ii) History of active drainage from the ear within the previous 90 days. (iii) History of sudden or rapidly progressive hearing loss within the previous 90 days. (iv) Acute or chronic dizziness. (v) Unilateral hearing loss of sudden or recent onset within the previous 90 days. (vi) Audiometric air-bone gap equal to or greater than 15 decibels at 500 hertz (Hz), 1,000 Hz, and 2,000 Hz. (vii) Visible evidence of signicant cerumen accumulation or a foreign body in the ear canal. (viii) Pain or discomfort in the ear. Special care should be exercised in selecting and tting a hearing aid whose maximum sound pressure level exceeds 132 decibels because there may be risk of impairing the remaining hearing of the hearing aid user. [This provision is required only for those hearing aids with a maximum sound pressure capability greater than 132 decibels (dB).]
Important notice for prospective hearing aid users
Good health practice requires that a person with a hearing loss have a medical evaluation by a licensed physician (preferably a physician who specializes in diseases of the ear) before purchasing a hearing aid.
40 41
Licensed physicians who specialize in diseases of the ear are oen referred to as otolaryngologists, otologists or otorhinolaryngologists. The purpose of medical evaluation is to assure that all medically treatable conditions that may aect hearing are identied and treated before the hearing aid is purchased. Following the medical evaluation, the physician will give you a written statement that states that your hearing loss has been medically evaluated and that you may be considered a candidate for a hearing aid. The physician will refer you to an audiologist or a hearing aid dispenser, as appropriate, for a hearing aid evaluation. The audiologist or hearing aid dispenser will conduct a hearing aid evaluation to assess your ability to hear with and without a hearing aid. The hearing aid evaluation will enable the audiologist or dispenser to select and t a hearing aid to your individual needs. If you have reservations about your ability to adapt to amplication, you should inquire about the availability of a trial-rental or purchase-option program. Many hearing aid dispensers now oer programs that permit you to wear a hearing aid for a period of time for a nominal fee aer which you may decide if you want to purchase the hearing aid. Federal law restricts the sale of hearing aids to those individuals who have obtained a medical evaluation from a licensed physician. Federal law permits a fully informed adult to sign a waiver statement declining the medical evaluation for religious or personal beliefs that preclude consultation with a physician. The exercise of such a waiver is not in your best health interest and its use is strongly discouraged.
Children with hearing loss
In addition to seeing a physician for a medical evaluation, a child with a hearing loss should be directed to an audiologist for evaluation and rehabilitation since hearing loss may cause
problems in language development and the educational and social growth of a child. An audiologist is qualied by training and experience to assist in the evaluation and rehabilitation of a child with a hearing loss.
Cell phone
Some hearing aid users have reported a buzzing sound in their hearing aids when they are using cell phones, indicating that the cell phone and hearing aid may not be compatible. According to the ANSI C63.19 standard (ANSI C63.19-2011 American National Standard Methods of Measurement of Compatibility Between Wireless Communications Devices and Hearing Aids), the compatibility of a particular hearing aid and cell phone can be predicted by adding the rating for the hearing aid immunity to the rating for the cell phone emissions. For example, the sum of the hearing aid rating of 2 (M2) and a telephone rating of 3 (M3) would result in a combined rating of 5. Any combined rating that equals at least 5 would provide “normal use”; a combined rating of 6 or greater would indicate “excellent performance.”
The immunity of this hearing aid is at least M2/T2. The equipment performance measurements, categories and system classications are based upon the best information available but cannot guarantee that all users will be satised.
Note: The performance of the individual hearing aids may
vary with individual cell phones. Therefore, please try this hearing aid with your cell phone or, if you are purchasing a new phone, please be sure to try it with your hearing aid prior to purchase. For additional guidance, please ask your hearing healthcare professional for the booklet entitled
“Hearing aid compatibility with digital wireless cell phones.”
42 43
Information and explanation of symbols
With the CE symbol, Unitron conrms that this
xxxx
©
Unitron product – including accessories – meets the requirements of the Medical Devices Directive 93/42/ EEC as well as the R&TTE Directive 1999/5/EC on radio and telecommunications transmitters.
The numbers aer the CE symbol correspond to the code of certied institutions that were consulted under the above-mentioned directives.
This symbol indicates that it is important for the user to read and take into account the relevant information in this user guide.
This symbol indicates that it is important for the user to pay attention to the relevant warning notices in this user guide.
Important information for handling and eective use of the product.
Australia and New Zealand EMC and Radiocommunications compliance label.
This symbol indicates that the products described in these user instructions adhere to the requirements for an application part of Type B of EN 60601-1. The surface of the hearing aid is specied as applicated part of Type B.
Copyright symbol
This symbol shall be accompanied by the name and
the address of the authorised representative in the
European Community.
This symbol shall be accompanied by the name and
the address of the manufacturer (who are placing this
device on the market).
Operating conditions:
This device is designed such that it functions without problems or restrictions if used as intended, unless otherwise noted in these user guides.
Transport conditions:
Temperature: –20° to +60° Celsius (–4° to +140° Fahrenheit). Humidity: Up to 90% (non condensing).
The symbol with the crossed-out garbage bin is to make you aware that this device may not be thrown away as normal household waste. Please dispose of old or unused devices, at waste disposal sites intended for electronic waste, or give your device to your hearing
healthcare professional for disposal. Proper disposal
protects the environment and health.
The Bluetooth® word mark and logos are registered
trademarks owned by Bluetooth SIG, Inc. and any
use of such marks by Unitron is under license. Other
trademarks and trade names are those of their
respective owners.
Stride™Stride™ is a trademark of Unitron.
44 45
Compliance information
Declaration of conformity
Unitron hereby declares that this Unitron product meets the requirements of the Medical Devices Directive 93/42/EEC as well as the Radio and Telecommunications Terminal Equipment Directive 1999/5/EC. The full text of the Declaration of Conformity can be obtained from the manufacturer.
The hearing aid described in this user guide is certied under:
Standard hearing system
Stride P Stride P Dura Stride M USA - FCC ID: VMY-UWNB3 VMY-UWNB1 VMY-UWNB4 Canada - IC: 2756A-UWNB3 2756A-UWNB1 2756A-UWNB4
Notice 1
This device complies with Part 15 of the FCC Rules and with RSS-
210 of Industry Canada. Operation is subject to the following two
conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received, including
interference that may cause undesirable operation.
Notice 2
Changes or modications made to this device not expressly approved by Unitron may void the FCC authorization to operate this device.
Notice 3
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of Industry Canada. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the device into an outlet on a circuit dierent from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for help
Australia: Supplier Code Number N15398
New Zealand: Supplier Code Number Z1285
46 47
Patient feedback
Record your specic needs or concerns and bring to
your rst oce visit aer getting your hearing aids.
This will help your hearing healthcare professional
to address your needs.
Additional notes
___________________________________________
___________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
________________________________________
48 49
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
___________________________________________
Unitron Hearing 20 Beasley Drive, P.O. Box 9017,
Kitchener, ON N2G 4X1 Canada
Unitron Hearing GmbH Max-Eyth-Straße 20, 70736
Fellbach-Oengen, Germany
For a listing of Unitron group
companies, please visit
www.unitron.com
Distributor
7
15-048 029-6061-02 © 2015-2016 Unitron. All rights reserved.
unitron.com
630034 390735
Loading...