Unitron 9725 User Manual

Page 1
User Manual
SFU dCSS Switch
Ref. 9725
Page 2
2
CONTENTS
1. PRODUCT DESCRIPTION .................................................................... 3
2. INSTALLATION OF THE HARDWARE ...................................................... 4
3. TECHNICAL SPECIFICATIONS ............................................................. 5
4. SAFETY INSTRUCTIONS .................................................................... 6
5. CONDITIONS OF WARRANTY ............................................................... 7
No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language without permission.
Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time.
Unitron cannot be held liable for any damages resulting from the use of this product. Specifications are subject to change without notice. 7/19
© Unitron - Frankrijklaan 27 - B-8970 Poperinge - Belgium
T +32 57 33 33 63 F +32 57 33 45 24
email sales@unitrongroup.com
www.unitrongroup.com
Page 3
SFU dCSS Switch (Ref. 9725)
3
1. PRODUCT DESCRIPTION
Upgrade to Sky Q without changing your existing quadplex wall socket. The 9725 SFU dCSS Switch converts a wideband signal to dCSS so you can connect any digital Set­Top box – such as Sky Q, Sky+, FreeSat or Freeview – without changing your in-home wall socket.
Designed for Pre-Wired dwellings with Wideband LNBs and Terrestrial and Radio
antennas
3 inputs: 2 Satellite cables (Wideband LNB) + 1 Terrestrial cable
2 outputs with 16 user bands each
multistandard: EN50494 – EN50607 – SKY – Legacy – Terr.
supporting New Build Developers and also for Retro-Fitting
makes all digital platforms available to residents
upgrade to Sky Q without changing your existing quadplex wall socket
for indoor use and outdoor use
Product can be used as indoor unit or as outdoor unit
Indoor unit Outdoor unit
Page 4
4
2. INSTALLATION OF THE HARDWARE
Page 5
SFU dCSS Switch (Ref. 9725)
5
3. TECHNICAL SPECIFICATIONS
9725
Inputs
-
2 SAT + 1 Terr./FM/DAB
Outputs
-
2 (Terr. + Legacy + SCR)
Input Frequency
MHz
Terr.: 5-862 SAT (wideband): 290-2340
Output Frequency
MHz
5-862 + 950-2150
Input/output connector
-
75 Ohm F type (Female)
dCSS/dSCR UBs
-
16 + 16
dCSS/dSCR output level
dBµV
85
Return loss
dB
>=8 dB (Typ 12)
Satellite loss
-
Not applicable, AGC (automatic gain control)
Terrestrial/Cable loss
dB
-4
Band and polarity selection
-
Universal LNB voltage & Tone DiSEqC 1.0 (unidirectional) DiSEqC 2.0 (bidirectional) Standard EN 50494 (SCD) Standard EN 50607 (SCD 2) SKY UK standard
Power consumption
W
< 3
Max DC current consumption
-
< 230mA @ 13 Volt
Power supply
-
From STB - To LNB
Operatin temperature
°C
-20 to +50
Dimensions indoor unit
mm
65x100x30 mm
Dimensions outdoor unit
mm
120x115x50 mm
Page 6
6
4. SAFETY INSTRUCTIONS
Read these instructions carefully before connecting the unit
To prevent fire, short circuit or shock
hazard:
• Do not expose the unit to rain or moisture.
• Install the unit in a dry location without infiltration or condensation of water.
• Do not expose it to dripping or splashing.
• Do not place objects filled with liquids, such as vases, on the apparatus.
• If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of
overheating:
• Install the unit in a well aery location and keep a minimum distance of 15 cm around the
apparatus for sufficient ventilation
• Do not place any items such as newspapers, table-cloths, curtains,
on the unit that might cover the ventilation holes.
• Do not place any naked flame sources, such as lighted candles, on the apparatus
• Do not install the product in a dusty place
• Use the apparatus only in moderate climates (not in tropical climates)
• Respect the minimum and maximum temperature specifications
To avoid any risk of electrical
shocks:
• Connect apparatus only to socket with protective earth connection.
• The mains plug shall remain readily operable
• Pull out power plug to make the different connections of cables
• To avoid electrical shock, do not open the housing of adapter.
Maintenance
Only use a dry soft cloth to clean the
cabinet.
Do not use solvent For repairing and servicing refer to qualified
personnel.
Dispose according your local authority’s recycling processes
Page 7
SFU dCSS Switch (Ref. 9725)
7
5. CONDITIONS OF WARRANTY
Unitron N.V. warrants the product as being free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it. See note below.
If during this period of warranty the product proves defective, under normal use, due to defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the product. Return the product to your local dealer for reparation
THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM:
Misuse or use of the product out of its specifications.
Installation or use in a manner inconsistent with the technical or safety standards in
force in the country where the product is used
Use of non-suitable accessories (power supply, adapters...).
Installation in a defect system.
External cause beyond the control of Unitron N.V. such as drop, accidents,
lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
Production date or serial number on the product is illegible, altered, deleted or
removed.
The product has been opened or repaired by a non-authorized person.
NOTE
Date of production can be found in the product’s serial number code. The format will either be “YEAR W WEEK” (e.g., 2018W01 = year 2018 week 1) or “YYWW” (e.g., 1847 = year 2018
week 47).
Page 8
8
UNITRON NV Frankrijklaan 27 B-8970 Poperinge Belgium
T +32 57 33 33 63 F +32 57 33 45 24
sales@unitrongroup.com
www.unitrongroup.com
Loading...