SFU dCSS Switch (Ref. 9725)
CONTENTS
1. PRODUCT DESCRIPTION .................................................................... 3
2. INSTALLATION OF THE HARDWARE ...................................................... 4
3. TECHNICAL SPECIFICATIONS ............................................................. 5
4. SAFETY INSTRUCTIONS .................................................................... 6
5. CONDITIONS OF WARRANTY ............................................................... 7
No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language
without permission.
Unitron reserves the right to change the specifications of the hardware and software described in these manuals
at any time.
Unitron cannot be held liable for any damages resulting from the use of this product. Specifications
are subject to change without notice. 7/19
© Unitron - Frankrijklaan 27 - B-8970 Poperinge - Belgium
T +32 57 33 33 63 F +32 57 33 45 24
email sales@unitrongroup.com
www.unitrongroup.com

SFU dCSS Switch (Ref. 9725)
1. PRODUCT DESCRIPTION
Upgrade to Sky Q without changing your existing quadplex wall socket. The 9725 SFU
dCSS Switch converts a wideband signal to dCSS so you can connect any digital SetTop box – such as Sky Q, Sky+, FreeSat or Freeview – without changing your in-home
wall socket.
• Designed for Pre-Wired dwellings with Wideband LNBs and Terrestrial and Radio
antennas
• 3 inputs: 2 Satellite cables (Wideband LNB) + 1 Terrestrial cable
• 2 outputs with 16 user bands each
• multistandard: EN50494 – EN50607 – SKY – Legacy – Terr.
• supporting New Build Developers and also for Retro-Fitting
• makes all digital platforms available to residents
• upgrade to Sky Q without changing your existing quadplex wall socket
• for indoor use and outdoor use
Product can be used as indoor unit or as outdoor unit
Indoor unit Outdoor unit

SFU dCSS Switch (Ref. 9725)
2. INSTALLATION OF THE HARDWARE

SFU dCSS Switch (Ref. 9725)
3. TECHNICAL SPECIFICATIONS
Terr.: 5-862
SAT (wideband): 290-2340
Not applicable, AGC (automatic gain control)
Band and polarity selection
Universal LNB voltage & Tone
DiSEqC 1.0 (unidirectional)
DiSEqC 2.0 (bidirectional)
Standard EN 50494 (SCD)
Standard EN 50607 (SCD 2)
SKY UK standard
Max DC current consumption

SFU dCSS Switch (Ref. 9725)
Read these instructions carefully before connecting the unit
To prevent fire, short circuit or shock
hazard:
• Do not expose the unit to rain or moisture.
• Install the unit in a dry location without infiltration or condensation of water.
• Do not expose it to dripping or splashing.
• Do not place objects filled with liquids, such as vases, on the apparatus.
• If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of
overheating:
• Install the unit in a well aery location and keep a minimum distance of 15 cm around the
apparatus for sufficient ventilation
• Do not place any items such as newspapers, table-cloths, curtains,
on the unit that might cover the ventilation holes.
• Do not place any naked flame sources, such as lighted candles, on the apparatus
• Do not install the product in a dusty place
• Use the apparatus only in moderate climates (not in tropical climates)
• Respect the minimum and maximum temperature specifications
To avoid any risk of electrical
shocks:
• Connect apparatus only to socket with protective earth connection.
• The mains plug shall remain readily operable
• Pull out power plug to make the different connections of cables
• To avoid electrical shock, do not open the housing of adapter.
Only use a dry soft cloth to clean the
cabinet.
Do not use solvent
For repairing and servicing refer to qualified
personnel.
Dispose according your local authority’s recycling processes

SFU dCSS Switch (Ref. 9725)
5. CONDITIONS OF WARRANTY
Unitron N.V. warrants the product as being free from defects in material and
workmanship for a period of 24 months starting from the date of production indicated on
it. See note below.
If during this period of warranty the product proves defective, under normal use, due to
defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the
product. Return the product to your local dealer for reparation
THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP
AND DOES NOT COVER DAMAGE RESULTING FROM:
• Misuse or use of the product out of its specifications.
• Installation or use in a manner inconsistent with the technical or safety standards in
force in the country where the product is used
• Use of non-suitable accessories (power supply, adapters...).
• Installation in a defect system.
• External cause beyond the control of Unitron N.V. such as drop, accidents,
lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
• Production date or serial number on the product is illegible, altered, deleted or
removed.
• The product has been opened or repaired by a non-authorized person.
NOTE
Date of production can be found in the product’s serial number code. The format will either be
“YEAR W WEEK” (e.g., 2018W01 = year 2018 week 1) or “YYWW” (e.g., 1847 = year 2018
week 47).