UNI-TREND UT 673A Instructions

P/N:0000000000
UT673A/UT675A Battery Tester
Overview
UT673A/UT675A battery tester, with its leading-edge conductivity test technology, accurately and rapidly helps users to measure the cold cranking amps capability of the vehicle starting battery, healthy state of the battery itself, detect the common fault of vehicle starting and charging system, which helps repair vehicle quickly.
Safety information
Please carefully read this manual and follow the warning and safety information before use.
To avoid fire and overcurrent, please read all rated values and symbol descriptions before use. Do not open the case cover. Do not turn on the tester if its cover or front panel is open. Do not touch the connectors and components if the tester is powered on. Please contact the authorized repair personnel to detect, repair, maintain the tester if you find any fault on it. Do not use in humid, explosive or inflammable environment. Keep the tester surface clean and dry. Keep it well-ventilated.
Product introduction
Interface
UT673A
1) Battery: Battery test.
2) Crank: Vehicle Cranking system test. Charge: Vehicle Charging system test.
3)
4) Data: The last test result can be viewed.
5) Setting: Language setting.
6) About: View the system information.
UT675A
1) Battery: Battery test.
2) Crank: Vehicle Cranking system test. Charge: Vehicle Charging system test.
3)
4) Data: The last test result can be viewed or upload.
5) Print: Print test data.
6) Setting: Language and time setting, view the system information.
Battery
Battery
Feature
1) Applicable to 12V battery testing and 12V/24V vehicle cranking/charging system test.
2) Measurement standard and range:
Measurement
standard
CCA
BCI
CA
MCA
JIS
3) Working temperature: -20°C 50°C.
Measurement
range
100-2000
100-2000
100-2000
100-2000
26A17—245H52
Measurement
standard
DIN
IEC
EN
SAE
4) Special test clip: Double-conductor Kelvin clip.
5) Case material: Acid-resistant ABS plastic.
6) Measurement range of battery: 30Ah200Ah.
7) Measurement range of voltage: 7V16V.
8) Portable.
Example for selecting standard
Battery identification
12V/60Ah/CCA 500A
300A EN
12V 250Ah 60Ah DIN
26A19R 12V 60Ah
26A19RMF 12V 60Ah
12V/60Ah
Standard
CCA
EN
DIN
JIS#
JIS#
AH
Battery
parameter
500
300
250A
200
220
60Ah
12V battery, the capacity is 60Ah, the cold-start current is 500A.
The standard value is 300A.
12V battery, the capacity is 60Ah, the standard value is 250A.
12V battery, the capacity is 60Ah, check JIS CODE conversion table and find that 26A19R corresponds to 220A for CCA.
12V battery, the capacity is 60Ah, check JIS CODE conversion table and find that 26A19R corresponds to 220A for MF CCA.
If the standard is not found, estimate CCA value according to the battery capacity.
Operation instruction
1. Connect the red and black clips of tester to the measured battery, red is positive, black is negative, the tester screen will display startup interface. If the battery voltage is lower than 7.0V, the test will become abnormal.
2. According to the prompts, press up and down button to select:
UT673A: Battery test, Charging test, View test results, Cranking test,
System setting, About.
UT675A: Battery test, Charging test, View test results, Cranking test,
Print test result, Setting.
UT673A
Crank
Setting
Data
UT675A
Data
Print
Measurement
Remark
Crank
range
100-1400
100-1400
100-2000
100-2000
30-200Ah
Charge
About
Charge
Setting
Tests below are based on 12V, 60Ah, CCA580A:
1. Battery test
1. Make sure engine is off. 2. Connect to the correct polarity.
NORMAL BAT.
AGM ATTERYB
TYPE
EFB ATTERYB
GEL ATTERYB
4. Select “NORMAL BAT”
TESTING
7. Press ENTER to start the test.
5. Select standard,CCA for example.
SOH 75% 495A
SOC 100% 12.8V
R= 3.35mΩ
CCA
DIN
JIS
EN
STANDARD
GOOD BATTERY
8. Display test result.
6. Set rated capacity of battery.
Battery Test results
Description
The battery is in
good condition.
The battery is in good condition, please charge the battery.
Retest after charging
Replace the battery
The battery is in bad condition, replace the battery.
The performance of storage battery is good, please continue using the battery.
Because the voltage of storage battery is lower than 12.3V, so the performance of storage battery is good, please continue using the storage battery after it is fully charged.
Because the battery voltage is lower than 12V, so please retest after it is fully charged. Incorrect reading may occur if the battery is not fully charged. Please replace the battery if “Retest after charging” displays again after charging.
Replace the storage battery.
Battery inside is damaged, replace the storage battery.
Interpretation
Battery capacity (SOC): The percentage of remaining battery capacity, 1)
Remaining capacity
SOC= ×100%.
Actual capacity
2) Battery voltage (VOLTAGE): The voltage value of storage battery (Unit: V). Battery life (SOH): State of health of battery storage, 3)
Actual capacity
SOH= ×100%.
Nominal capacity
The measured cold-start current: The measured cold-start current of tester.4) Nominal cold-start current: Nominal cold-start current of storage battery5) Internal resistance of battery (R): The measured internal resistance of storage battery.6)
NOTE: For low-capacity battery (For example, the vehicle is shut down for a long time, the battery is not charged in time, the battery power is significantly lost because the vehicle door is not closed.), the tester may prompt you to “Replace battery” during actual measurement, please consult the storage battery factory and charge the battery according to the designated method, and then retest.
2. Cranking test
1. Make sure engine is off. 2. Connect to the correct polarity.
CRANKING TEST
START ENGINE
4. Enter the interfaceof starting engine.
TESTING
7. Automatically enter the test.
5. Start engine.
CRANKING NORMAL
CRANKING 11.34V
TIME 243ms
8. Display test result.
UT673A
Crank
Setting
UT675A
Crank
Print
580 A
UT673A
Crank
Setting
UT675A
Crank
Print
Charge
About
Charge
Setting
CCA
Charge
About
Charge
Setting
Battery
Data
Battery
Data
3. Select “Battery”
SET RATING
Battery
Data
Battery
Data
3. Select “Crank”
CRANKING TEST
RPM DETECTED
6. Engine RPM is detected.
Test results
Decision
Starting voltage is normal.
Starting voltage is low.
Interpretation
The starting voltage is higher than 9.6V.
The starting voltage is lower than 9.6V.
3. Charging test
UT673A
Battery
Data
Battery
Data
1. Make sure engine is off. 2. Connect to the correct polarity. 3. Select “Charge”
CHARGING TEST
START ENGINE
PRESS ENTER TO
CONTINUE
4. Enter the interface of starting engine.
LOADED TESTING
***
7. Start loaded testing
5. Start engine.
INCREASE RPM TO
2500 R/MIN AND
KEEP IT 5 SECONDS PRESS ENTER TO
8. According to the prompt, Step on accelerator to increase the engine speed to 2500 R/Min and hold for 5 seconds.
6. Start ripple test.
CHARGING NORMAL
LOADED 14.26V
UNLOADED 12.65V RIPPLE 5mV
9. Display test result.
Charge
Crank
About
Setting
UT675A
Charge
Crank
Setting
Print
RIPPLE TEST
5mV 12.65V
Test results:
Decision
Charging voltage is normal.
Charging voltage is low.
Charging voltage is high.
No voltage output.
Diode test.
Charging system is normal, the output voltage of engine is 13.5V 14.7V.~
Charging system is under-voltage, the voltage is lower than 13.5V.
The voltage of charging system is higher than that of vehicle voltage stabilizer.
Generator voltage output is not detected. Check if the connector and generator belt is normal.
Test via current waveform, for example, the diode is damaged due to high ripple voltage of diode.
Interpretation
View test result
a) F or UT6 73A, ENT ER to v iew th e last test res ult of Batte ry tes t, Crank ing an d Charging system test. b) For UT675A, ENTER to view and export the last test result of Battery test, Cranking and Charging system test. Connect the computer to export the last test result via serial port and print the result.
Note: Please find the application software on our website by searching UT675A and search under Docs & Software section.
https://www.uni-trend.com.cn/index.php?m=content& c=index&a=show&catid=515&id=882
About (Applicable to UT673A)
ENTER to view system information.
Print test result (Applicable to UT675A)
ENTER to print the last test result of Battery test, Cranking and Charging system test.
Note: The normal working voltage of the printer is 10 16V.~
Setting
ENTER to select language (English or Chinese).
Function
ENTER to enter setting page.
Language selection
User can select desired language as needed. After entering language selection page, press ENTER to select English or Chinese.
Time adjustment (Applicable to UT675A)
User can adjust or correct the system time, time sequence adjustment (Year/Month/Day /Hour/Minute) does not affect the setting of date and time format. a. Press up or down button to adjust the last two digits of the YEAR, then press ENTER to confirm this adjustment and enter month adjustment.
b. Press up or down button to adjust Month, then press ENTER to confirm this adjustment and enter date adjustment. c. Press up or down button to adjust DATE, then press ENTER to confirm this adjustment and enter hour adjustment. d. Press up or down button to adjust HOUR, then press ENTER to confirm this adjustment and minute adjustment.
e. Press up or down button to adjust MINUTE, then press ENTER until “OK” is displayed. After finishing the adjustment, the tester will go back to main interface. When adjusting the time, the time character will flash. By pressing and holding the button, the character will increase or decrease continuously.
NOTE: Make sure the button is pressed for more than one second when adjusting time. After entering time setting, pressing return button is disabled because the system time is protected, users need to set Year/Month/Day/Hour/Minute or press return button 5 times to return.
Specification
Model
Applicable battery
Battery type
Battery capacity
Battery standard and range
Voltage range
Test method
AH rapid measurement
Overvoltage protection
Prevent counter voltage
A prompt of poor contact
Internal resistance measurement
Battery life
Remaining battery capacity
Cranking test
Charging test
USB data transfer
Printing function
LCD
Language
General
Temperature Working environment
Net weight (excluding batteries)
Product dimension (excluding test leads)
Relative humidity
Packing box dimension
76mm *2 2m m* 14 2m m
175m m* 45 mm *3 20 mm 285m m* 90 mm *2 30mm
UT673A
UT675A
12V cranking lead acid battery
Ordinary lead acid battery, AGM flat plate battery,
AGM spiral battery, GEL battery, EFB battery.
3 250AH~
CCA:40 2000; BCI 40 2000; CA 40 2000 MCA
~ : ~ : ~ ; :
40~2000; JIS:26A17~245H52; DIN:40~1400; IEC:
40~1400; EN:40~2000;SAE:40~2000; AH:3~250 AH
7 16V DC~
Four-terminal kelvin test lead
12/24V cranking system test
12/24V charging system test
/ /
LCD (128*64 black and white lattice)
Chinese and English
0°C 50°C~
Operating: below +35°C, 90%
Non-operating: +35°C +40°C, 60%~
264g
413g
95mm *4 7m m* 18 3m m
Accessories
UT675AUT673A
Tester host: 1 piece
User manual: 1 piece
Velcro strap: 1 piece
Tester host: 1 piece
User manual: 1 piece
USB cable: 1 piece Printing paper: 3 pieces
Cloth bag: 1 piece
Maintenance
1. Do not put or store the tester in the place where its LCD is exposed to direct sunlight for a long time. No sprays, liquids or solvents are allowed on the tester or fixtures.
2. Please clean the dust on the tester with soft cloth. Do not scratch the protection screen of LCD. Wipe the tester with a damp but non-dripping soft cloth. Never use any corrosive chemical detergents.
Warning: Before the tester is powered on, please make sure it is completely dry to
avoid short circuit caused by moisture.
Loading...
+ 1 hidden pages