Unitek ALPHA 750 PS, ALPHA 1200 PS, ALPHA 1000 PS User Manual

Manual del usario
User’s manual
Manual do utilizador
ALPHA
750/1000/1200 PS
SAI in-line 750/1000/1200 VA
750/1000/1200 VA in-line UPS
www.unitekpoweronline.com
TABLE OF CONTENT
1. Overview – System Description
1-1. Introduction 1-2. System Description
2. Installation and Operation
2-1. Installation 2-2. Operation
3. Led and Alarm Indication
3-1. Alarm Indication 3-2. Led Indication
4. Caution
5. Trouble shooting
1. Overview 1-1 Introduction
The PS family of UPS (Uninterruptible Power Supply), is a line interactive device with features conceived to provide an excellent protection to computers (PC), networks, workstations and small capacity internet devices.
The PS family has an Automatic Voltage Regulator (AVR) that allows to operate in stable conditions under varations of the main power, without the need to get into battery or backed up mode. This features results in in extended battery life.
The family uses a RISC (Reduced Instruction Set Computer), that provides greater operational flexibility: 1) “Delayed turn on”. During the turn on process the microprocessor analizes the main power in order to ensure that it is in adequate conditions for the unit to operate. 2) Green Power function. 3) “Overload Detection” and desactivation of the load if the overload persists during a predetermined time. Additionally, the PS family has surge protection, nosie filtering and fax/modem protection.
SPECIFICATIONS:
UPS UNITEK
MODEL
ALPHA 750Ps, 1000Ps & 1200Ps
CAPACITY
VA/W
750VA/360W, 1000VA/480W & 1200VA/600W
INPUT
Voltage
220, 230, 240VAC
Voltage Range
+/- 25%
Frequency
50Hz / 60Hz Auto sensing
OUTPUT
Voltage
220, 230, 240VAC
Voltage Regulation
+/- 10% with Automatic Voltage Regulation
Frequency
50Hz or 60Hz Frequency Regulation (Battery Mode)
+/- 0.5%
Output Waveform
Modified Sinewave
Topology
Line Interactive
Transfer Time
4ms Typical
Number of sockets
4 IEC with Back-up
BATTERY
Battery Type
Sealed, Lead Acid, Maintenance Free,
Rechargeable Battery Quantity and Capacity
1 x 12V/7.2AH, 1 x 12V/7.2AH & 1 x 12V/9AH
Recharge Time
4 Hours to 90% after complete discharge
Protection
Self-Diagnostics Upon Power On
INDICATOR
AC Mode
Green LED lighting
Battery Mode
Yellow LED lighting
Fault
Red LED lighting
AUDIBLE ALARM
Battery Mode
Sounding every 4 seconds / Alarm Reset
Function
Low Battery
Sounding every second
Overload
Continuously sounding
PROTECTION
Switch Function
UPS Automatic Switch for City Power &
Battery
Unit Input
Fuse for Overload & Short Circuit Protection
Overload Protection
UPS Automatic Shutdown if Overload:
Over 110% of Nominal at 60 Seconds and
130% at 5 Seconds
Short Circuit
UPS Output Cut Off Immediately and Input
Fuse Protection
Spike Protection
80 Joules, Over 2ms
Green Mode
Inverter will Automatically Shutdown without
Load
Modem / Network
RJ-11
APPROVALS
Noise Suppression
MEETS CE (EN 50091) and FCC Class B
Surge Suppression
MEET IEEE 587
PHYSICAL
Dimension, DxWxH
275 x 110 x 202 (mm)
Weight: Net / Gross
5.3 / 5.8 (kgs), 5.9 / 6.4 (kgs) & 6.5 / 7 (kgs)
ENVIRONMENT
Altitude
Less than 5000 meters
Temperature
0 °C ~ 50 °C
Relative Humidity
0 ~ 90 % (non-condensing)
Audible Noise Level
Less than 40dB (1 meter from surface)
INTERFACE
Smart RS-232 or USB, cable included
Support Windows: 95, NT4.0, 98SE, ME, 2K,
XP, Server2003
Linux: Redhat7.0~7.3 & Mandrake8.2, Novell:
4.X & 5.1
www.unitekamerica.com
1-2 System Description
1. Full digital microprocessor controlled
2. Power saving and sleeping mode
3. Boost and buck AVR (Auto Voltage Regulation)
4. Smart communication port (USB)
5. Fax/Modem/Network surge suppression
6. 50/60Hz auto detecting
7. Cold start function (DC power on)
8. Short Circuit and overload protection
9. Automatic diagnostics & battery check while power on
10. Attractive smart color combination
11. Elegant outlook for both vertical and horizontal positioning
Orange LED Indicator:­Battery Mode
Front Panel
Red Led Indicator: ­Battery Low/ Overload
Green Led indicator:­AC Mode
Modem / Phone Line Surge Protection
AC Input with Fuse
IEC Output Receptacles
Rear Panel
2. INSTALLATION AND OPERATION 2-1. Installation
The following steps explain how to install the UPS to your PC. Step 1. Assure AC power source output voltage is in the UPS Requires voltage range specified on the rear panel. Step 2. Plug the UPS power cord into a wall outlet or other Power source. Step 3. Plug the personal computer (PC) into the UPS output. Step 4. Start the UPS by pressing the ON/OFF button for 4 seconds. After the UPS turns on, it conducts a self-test and enters Normal AC power mode. The AC power green LED indicator illuminates indicating that power is available from the rear
receptacles. Step 5. Shutdown the UPS by pressing ON/OFF button for 6 seconds untill Red LED indicator illuminate.
2-2. OPERATION
2-2-1. Turning the UPS ON Press the power ON/OFF on the front panel. After the UPS green LED is turned on. It conducts a self-test and enters normal mode. 2-2-2. Starting the UPS on battery To turn on the UPS without using AC power, press ON/OFF button
and Hold for 6 seconds to conserve battery power
(The UPS does not conduct Self-test when UPS start on battery). 2-2-3. Turning The UPS OFF Press the power ON/OFF on the front panel when UPS power off.
It would not in standby mode Indicator
3. LED and Alarm Indication: 3-1. LED indication
GREEN
ORANGE
RED AC power mode (UPS ON)
AC power failure and Switch to battery mode
UPS fault overload
3-2. Alarm indication
Beep Every 4 seconds
Beep Every 1 Second
Beep Continuously
Beep Every 0.5 second UPS runs on battery Mode. Press ON/OFF button for 6 seconds to stop Beep
Low battery Warning
Battery overload warning
Battery Low