United States Stove Company DV8 User Manual

MODELS
DV8 (N,L) DV14 (N,L) DV21 (N,L)
TESTED & LISTED BY
C
OMNI-TEST LABORATORIES, INC
REPORT NO.:
215-S-31-4
PORTLAND
OREGON, USA
NEED HELP ?
DO NOT RETURN THIS PRODUCT TO THE STORE WHERE YOU PURCHASED IT. If you have questions about assembling or operating this appliance or if it seems defective or parts are missing or replacement parts required: Please contact our Customer Support 1-800-750-2723
Page 1
Heater ............................
Page 2
DV8
DV8
DV14
DV21
DV14 DV21
Propane/
/NG
or
/NG
DV8
/NG
DV14
DV21
610 m
/NG /NG/LP /LP
DV8
DV14 DV21
The efficiency rating of the appliance is a product thermal efficiency rating
determined under continuous operating conditions and was determined independently of any installed system.
610 m
DV14 DV8 DV21
Page 3
24 5/64”
DV8 DV14 DV21
12 15/64” 19 39/64” 25 19/32”
5 1/32” (MDV8-MDV14) 7 1/32” (MDV21)
Do not use this appliance if any part has been under water. Immediately call a qualified technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Page 4
(For U.S. vent terminal installations)
*
* This installation information applies in the USA, for Canadian installation refer to page 7 of this manual
Page 5
4.
Page 6
Clearance above grade, veranda, porch, deck, or balcony
Clearance to window or door that may be opened
Clearance to permanently closed window
Vertical Clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61 cm) from the center line of the terminal
Clearance to unventilated soffit Clearance to outside corner. Clearance to inside corner.
Clearance to each side of center line extended above meter/regulator assembly.
Clearance to service regulator vent outlet.
Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any building or other appliance.
Clearance to mechanical air supply inlet.
Clearance above paved side walk or paved driveway located on public property.
Clearance under veranda, porch, deck or balcony.
Canadian Installations¹
12 inches (30cm)
6 inches (15 cm) for appliances < 10,000 Btuh (3 kW), 12 inches (30 cm) for appliances > 10,000 Btuh (3kW) and <100,000 Btuh (30kW), 36 inches (91 cm)for appliances > 100,000 Btuh (30kW).
3 feet (91 cm)
3 feet (91 cm) within a height 15 feet (4.57 m) above the meter/regulator assembly.
3 feet (91 cm)
6 inches (15 cm) for appliances < 10,000 Btuh (3 kW), 12 inches (30 cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36 inches (91 cm) for appliances > 100,000 Btuh (30kW).
6 feet (1.83 m)
7 feet (2.13m)
12 inches (30cm)
2
12 inches (30cm)
6 inches (15 cm) for appliances < 10,000 Btuh (3 kW), 9 inches (23 cm) for appliances > 10,000 Btuh (3 kW) and < 50,000 Btuh (15 kW), 12 inches (30 cm) for appliances > 50,000 Btuh (15 kW).
3 feet (91 cm)
6 inches (15 cm) for appliances <10,000 Btuh (3 kW), 9 inches (23 cm) for appliances > 10,000 Btuh (3 kW) and < 50,000 Btuh (15 kW), 12 inches (30 cm) for appliances > 50,000 Btuh (15 kW).
3 feet (91 cm) above if within 10 feet (3 m) horizontally.
Page 7
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Page 8
DV21
DV14
DV8
Do not connect this appliance to a chimney flue serving a separate solid fuel appliance.
Page 9