United States Stove 9947 User Manual

UNITED STATES
STOVE COMPANY
227 INDUSTRIAL PARK ROAD • P.O. BOX 151 • SOUTH PITTSBURG, TN. 37380 • (423)-837-2100
Natural Gas Model
C9947N
Supplemental Heater
Propane (LPG) Gas Model
C9947L
Supplemental Heater
Fiero
®
Owner's Operation and Installation ManualOwner's Operation and Installation Manual
Owner's Operation and Installation Manual
Owner's Operation and Installation ManualOwner's Operation and Installation Manual
This appliance may be installed in an aftermarket* manufactured (mobile) home,This appliance may be installed in an aftermarket* manufactured (mobile) home,
This appliance may be installed in an aftermarket* manufactured (mobile) home,
This appliance may be installed in an aftermarket* manufactured (mobile) home,This appliance may be installed in an aftermarket* manufactured (mobile) home,
where not prohibited by state or local codes.where not prohibited by state or local codes.
where not prohibited by state or local codes.
where not prohibited by state or local codes.where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
This appliance is only for use with the type gas indicated on the rating plate. This appli-This appliance is only for use with the type gas indicated on the rating plate. This appli-
This appliance is only for use with the type gas indicated on the rating plate. This appli-
This appliance is only for use with the type gas indicated on the rating plate. This appli-This appliance is only for use with the type gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases.ance is not convertible for use with other gases.
ance is not convertible for use with other gases.
ance is not convertible for use with other gases.ance is not convertible for use with other gases.
This is an unvented gas-fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combus­tion and ventilation air must be provided. Refer to "Adequate Combustion And Ventilation Air" on page(s) 6 of this manual.
WW
ARNING:ARNING:
W
ARNING:
WW
ARNING:ARNING:
Do not use a blower insert,Do not use a blower insert,
Do not use a blower insert,
Do not use a blower insert,Do not use a blower insert,
heat exchanger insert or otherheat exchanger insert or other
heat exchanger insert or other
heat exchanger insert or otherheat exchanger insert or other
accessories not approvedaccessories not approved
accessories not approved
accessories not approvedaccessories not approved
ff
or use with this heateror use with this heater
f
or use with this heater
ff
or use with this heateror use with this heater
Save this manual for
future reference.
..
.
..
WW
ARNING:ARNING:
W
ARNING:
WW
ARNING:ARNING:
ff
olloollo
wed ewed e
f
ollo
wed e
ff
olloollo
wed ewed e
causing prcausing pr
causing pr
causing prcausing pr life.life.
life.
life.life.
~Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
~WHA~WHA
~WHA
~WHA~WHA
~Installation and service must be performed by a~Installation and service must be performed by a
~Installation and service must be performed by a
~Installation and service must be performed by a~Installation and service must be performed by a qualified installerqualified installer
qualified installer
qualified installerqualified installer
If the inf If the inf
If the inf
If the inf If the inf
xactlxactl
xactl
xactlxactl
operoper
ty damaty dama
oper
ty dama
operoper
ty damaty dama
T T
TT
O DO IF O DO IF
T
T
O DO IF
T T
TT
O DO IF O DO IF
• Do not try to light any appliance.• Do not try to light any appliance.
• Do not try to light any appliance.
• Do not try to light any appliance.• Do not try to light any appliance.
• Do not touch any electrical switch; do not• Do not touch any electrical switch; do not
• Do not touch any electrical switch; do not
• Do not touch any electrical switch; do not• Do not touch any electrical switch; do not use any phone in your building.use any phone in your building.
use any phone in your building.
use any phone in your building.use any phone in your building.
• Immediately call your gas supplier from a• Immediately call your gas supplier from a
• Immediately call your gas supplier from a
• Immediately call your gas supplier from a• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier'sneighbor's phone. Follow the gas supplier's
neighbor's phone. Follow the gas supplier's
neighbor's phone. Follow the gas supplier'sneighbor's phone. Follow the gas supplier's instructions.instructions.
instructions.
instructions.instructions.
• If y• If y
ou cannot reacou cannot reac
• If y
ou cannot reac
• If y• If y
ou cannot reacou cannot reac
the fire department.the fire department.
the fire department.
the fire department.the fire department.
ormation in this manormation in this man
ormation in this man
ormation in this manormation in this man
yy
,,
a fire or e a fire or e
y
,
a fire or e
yy
,,
a fire or e a fire or e
gg
ee
g
e
gg
ee
YY
OU SMELL GASOU SMELL GAS
Y
OU SMELL GAS
YY
OU SMELL GASOU SMELL GAS
h yh y
h y
h yh y
,,
ser ser
vice avice a
,
ser
vice a
,,
ser ser
vice avice a
xplosion maxplosion ma
xplosion ma
xplosion maxplosion ma
,,
per per
sonal injursonal injur
,
per
sonal injur
,,
per per
sonal injursonal injur
our gas supplierour gas supplier
our gas supplier
our gas supplierour gas supplier
gg
encenc
yy
g
enc
y
gg
encenc
yy
ual is notual is not
ual is not
ual is notual is not
y resulty result
y result
y resulty result
yy
,,
or loss of or loss of
y
,
or loss of
yy
,,
or loss of or loss of
,,
call call
,
call
,,
call call
,,
or the gas supplier or the gas supplier
,
or the gas supplier
,,
or the gas supplier or the gas supplier
851371-C
..
.
..
TABLE OF CONTENTS
SECTION PSECTION P
SECTION P
SECTION PSECTION P
IMPORTANT SAFETY INFORMA TION.......................................................3-4
PRODUCT FEATURES..................................................................................4
9947 SPECIFICATIONS.................................................................................5
CONTENTS....................................................................................................5
ITEMS REQUIRED FOR INSTALLATION......................................................6
INSTALLATION...............................................................................................7
MANTEL CLEARANCES................................................................................8
GAS CONNECTION..................................................................................9-10
GAS PRESSURE CHECK.............................................................................10
FRONT SCREEN REMOVAL.......................................................................11
LOG ASSEMBLY...........................................................................................11
OPERATING INSTRUCTIONS................................................................12-14
AA
A
AA
GEGE
GE
GEGE
CLEANING / SERVICING.......................................................................14-15
FLAME APPEARANCE................................................................................15
PARTS LIST FOR HEATER ASSEMBLY.................................................16-17
PARTS LIST FOR BURNER AND LOG ASSEMBLY...............................18-19
TROUBLE SHOOTING...........................................................................20-21
OPTIONAL EQUIPMENT..............................................................................22
WIRING DIAGRAMS...............................................................................23-25
NOTES..........................................................................................................26
LIMITED WARRANTY POLICY....................................................................27
NOTICE
Installation and repair must be done by a qualified service person. The appliance should be in­spected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
2
IMPORTANT SAFETY INFORMATION
INSTINST
ALLER:ALLER:
INST
ALLER:
INSTINST
ALLER:ALLER:
OWNER: OWNER:
OWNER: Please retain these instructions for future reference.
OWNER: OWNER: IMPORIMPOR
IMPOR
IMPORIMPOR WW
W
WW
use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
1.
2. The installation must conform with local codes or , in the absence of local codes, with the National
2. This heater shall not be installed in a bedroom or bathroom.
4.
TT
T
TT
ARNING:ARNING:
ARNING:
ARNING:ARNING:
CARBON MONOXIDE POISONING:CARBON MONOXIDE POISONING:
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to
CARBON MONOXIDE POISONING:CARBON MONOXIDE POISONING:
the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater serviced as it may not be operating properly.
Fuel Gas Code, ANSI Z223.1.
WW
ARNING:ARNING:
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause
WW
ARNING:ARNING:
injury or property damage. Refer to this owner's manual. Installation and service must be performed by a qualified installer, ser vice agency or the gas supplier.
Please leave these instructions with the owner.
ANTANT
::
ANT
:
Read these instructions carefully before installing or trying to operate this heater.
ANTANT
::
Any change to this heater or its controls can be dangerous. Improper installation or
5. To prevent malfunction and/or sooting, a vent-free gas heater should be cleaned at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, etc. It is imperative that control compartments, burners and circulating air passageways be kept clean.
6.
Correct placement of the ceramic fiber logs is necessary to avoid problems with sooting. Sooting can settle on surfaces outside the heater and cause discoloration. See the appropriate sections of this manual for instructions.
WW
7.
8. This is a vent-free gas fired heater. It uses air (oxygen) from the room in which it is installed.
9.
10.
ARNING:ARNING:
W
ARNING:
WW
ARNING:ARNING:
flame patterns. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.
Provisions for adequate combustion and ventilation air must be provided. Refer to installation guidelines.
Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
Young children should be carefully super vised when they are in the same room with the appliance.
Do not allow f ans to b lo w directly into the fireplace. A v oid any dr afts that alter burner
11. Do not place clothing or other flammable material near the appliance.
3
IMPORTANT SAFETY INFORMATION
13. Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
15. Any safety screen or guard removed for servicing, must be replaced prior to heater operation.
16.
This vent-free gas heater is intended to be smok eless. If logs appear to smoke , turn off the heater and call a qualified service person. during the first four hours of operation.
17. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings s Refer to the National Fuel Gas Code.
18. The appliance and its appliance main gas shut off valve must be disconnected from the gas supply piping 2 psig (3.5 kPa).
19.
The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
system during any pressure testing of that system at test pressures in excess of 1/
hould be reduced 4 percent per 1,000 feet above sea level.
Initial burn off may cause slight smoke and odor
CONTINUED
20. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control that has been under water.
PRODUCT FEATURES
Features:Features:
Features:
Features:Features:
• Heating Efficiency - 99.9%
• Wide BTU Range: 27,000-39,900.
• Safe Operation -
Oxygen Depletion Sensor (ODS).
• Fibre Ceramic Logs.
• 120 CFM Blower
• Push-Button Piezo Ignitor.
• Clean Operation.
• Easy Operation.
• Heats up to 1,200 square feet.
• Optional Remote Control, Wall Switch
and Wall Thermostat Kits
9947 Vent-free Gas Pedestal Heater9947 Vent-free Gas Pedestal Heater
9947 Vent-free Gas Pedestal Heater
9947 Vent-free Gas Pedestal Heater9947 Vent-free Gas Pedestal Heater
Figure 1.Figure 1.
Figure 1.
4
Figure 1.Figure 1.
9947 SPECIFICATIONS
Natural GasNatural Gas
Natural Gas
Natural GasNatural Gas
Manifold Pressure Setting: 4" w.c. Gas Inlet Pressure: Maximum 10-1/2" w.c.
Minimum 5" w.c.
Propane/LPGPropane/LPG
Propane/LPG
Propane/LPGPropane/LPG
Manifold Pressure Setting: 10" w.c. Gas Inlet Pressure: Maximum 13" w.c.
Minimum 11" w.c.
Model NumberModel Number
Model Number
Model NumberModel Number
9947N Manual 39,900 27,000 1 9947L Manual 39,900 27,000 1
ControlsControls
Controls - Main control has 4 positions:
ControlsControls
1. OFF - All gas to the gas logs is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light/maintain a standing pilot
4. ON - Gas flow to complete system.
HIGH / LOW ControlHIGH / LOW Control
HIGH / LOW Control - Infinite control :
HIGH / LOW ControlHIGH / LOW Control
Rotate knob clockwise to
TT
ypeype
T
ype
TT
ypeype
LOLO
LO
LOLO
CONTENTS
9947L and 9947N Un9947L and 9947N Un
9947L and 9947N Un
9947L and 9947N Un9947L and 9947N Un
1. Packet containing Homeowner's/Installation instructions.
2. Three (3) individually wr apped fiber ceramic logs, refer to installation instructions.
3. Un vented gas heater.
vented Gas Heatervented Gas Heater
vented Gas Heater
vented Gas Heatervented Gas Heater
Gas RateGas Rate
Gas Rate
Gas RateGas Rate
Max BTU/HrMax BTU/Hr
Max BTU/Hr
Max BTU/HrMax BTU/Hr
WW
,,
W
,
counter clockwise to
WW
,,
ss
s
ss
Min BTU/HrMin BTU/Hr
Min BTU/Hr
Min BTU/HrMin BTU/Hr
HIGHHIGH
HIGH.
HIGHHIGH
NumberNumber
Number
NumberNumber
of Burnersof Burners
of Burners
of Burnersof Burners
CHECK CHECK
CHECK
CHECK CHECK
GLOGLO
VES ARE RECOMMENDED VES ARE RECOMMENDED
GLO
VES ARE RECOMMENDED
GLOGLO
VES ARE RECOMMENDED VES ARE RECOMMENDED
LOGS LOGS
LOGS
LOGS LOGS ARE FRAARE FRA
ARE FRA
ARE FRAARE FRA
Carefully inspect the contents for shipping damage and immediately inform
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
your dealer if any damage is found.
TT
T
TT
THATHA
T ALL LISTED PT ALL LISTED P
THA
T ALL LISTED P
THATHA
T ALL LISTED PT ALL LISTED P
O PREVENT SKIN IRRITO PREVENT SKIN IRRIT
O PREVENT SKIN IRRIT
O PREVENT SKIN IRRITO PREVENT SKIN IRRIT
GILE,GILE,
GILE,
GILE,GILE,
HANDLE HANDLE
HANDLE
HANDLE HANDLE
ARAR
AR
ARAR
WITH CARE.WITH CARE.
WITH CARE.
WITH CARE.WITH CARE.
TS HATS HA
TS HA
TS HATS HA
WHEN HANDLING CERAMIC FIBERWHEN HANDLING CERAMIC FIBER
WHEN HANDLING CERAMIC FIBER
WHEN HANDLING CERAMIC FIBERWHEN HANDLING CERAMIC FIBER
AA
TION FRTION FR
A
TION FR
AA
TION FRTION FR
VE BEEN RECEIVEDVE BEEN RECEIVED
VE BEEN RECEIVED
VE BEEN RECEIVEDVE BEEN RECEIVED
OM LOOSE FIBERS.OM LOOSE FIBERS.
OM LOOSE FIBERS.
OM LOOSE FIBERS.OM LOOSE FIBERS.
LOGS LOGS
LOGS
LOGS LOGS
5
ITEMS REQUIRED FOR INSTALLATION
ITEMS REQITEMS REQ
ITEMS REQ
ITEMS REQITEMS REQ
Ensure that the following items are available before proceeding with installation:
CODESCODES
CODES
CODESCODES
Adhere to all local codes or in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSIZ223.1 or NFPA54 which can be obtained from:
American National Standards Institute, Inc.American National Standards Institute, Inc.
American National Standards Institute, Inc.
American National Standards Institute, Inc.American National Standards Institute, Inc.
ARNINGARNING
ARNINGARNING
ARNING WW
WW
W
UIRED FOR INSTUIRED FOR INST
UIRED FOR INST
UIRED FOR INSTUIRED FOR INST
• External regulator (for propane/LPG only) • Manual cutoff valve
• Piping which complies with local codes • Sediment trap
• Pipe sealant approved for use with • Pipe wrench propane / LPG (resistant to sulfur compounds)
1430 Broadway
New Yor k, NY 10018 Quincy, MA 02269
Due to high temperatures, do not install the heater:Due to high temperatures, do not install the heater:
Due to high temperatures, do not install the heater:
Due to high temperatures, do not install the heater:Due to high temperatures, do not install the heater:
• Where curtains, furniture, clothing or other flammable objects are less than• Where curtains, furniture, clothing or other flammable objects are less than
• Where curtains, furniture, clothing or other flammable objects are less than
• Where curtains, furniture, clothing or other flammable objects are less than• Where curtains, furniture, clothing or other flammable objects are less than 42" fr42" fr
42" fr
42" fr42" fr
• In high traffic areas.• In high traffic areas.
• In high traffic areas.
• In high traffic areas.• In high traffic areas.
• In windy or drafty areas.• In windy or drafty areas.
• In windy or drafty areas.
• In windy or drafty areas.• In windy or drafty areas.
DO NODO NO
DO NO
DO NODO NO THE APPLIANCE.THE APPLIANCE.
THE APPLIANCE.
THE APPLIANCE.THE APPLIANCE.
om the from the fr
om the fr
om the from the fr
T PLAT PLA
T PLA
T PLAT PLA
ALLAALLA
ALLA
ALLAALLA
ont of the heateront of the heater
ont of the heater
ont of the heateront of the heater
CE CLOCE CLO
CE CLO
CE CLOCE CLO
TIONTION
TION
TIONTION
THING OF OTHING OF O
THING OF O
THING OF OTHING OF O
National Fire Protection Association, Inc.National Fire Protection Association, Inc.
National Fire Protection Association, Inc.
National Fire Protection Association, Inc.National Fire Protection Association, Inc.
oror
or Batterymarch Park
oror
..
.
..
THER FLAMMABLE MATHER FLAMMABLE MA
THER FLAMMABLE MA
THER FLAMMABLE MATHER FLAMMABLE MA
TERIAL ON OR NEARTERIAL ON OR NEAR
TERIAL ON OR NEAR
TERIAL ON OR NEARTERIAL ON OR NEAR
ADEQADEQ
ADEQ
ADEQADEQ
This heater shall not be installed in a confined space unless provisions are provided for adequate combus­tion and ventilation air.
The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8m³ per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space is defined as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8m³ per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not fur­nished with doors, are considered a part of that unconfined space.
UU
AA
TE COMBTE COMB
U
A
TE COMB
UU
AA
TE COMBTE COMB
(a) Walls and ceiling exposed to the outside atmosphere have a continuous water vapor retarded with a rating of 1 perm (6 x 10 kg per pa-sec-m²) or less with openings gasketed or sealed , and (b) Weather str ipping has been added on openable windows and doors, and (c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, gas lines, and at other openings.
USTION AND USTION AND
USTION AND
USTION AND USTION AND
VENTILAVENTILA
VENTILA
VENTILAVENTILA
11
TION AIRTION AIR
TION AIR
TION AIRTION AIR
6
INSTALLATION
The following formula can be used to determine the maximum heater rating per the definition of unconfined space:
BTU/HR = (L1+L2) Ft x (W) Ft x (H) Ft x 1000
50
Consider two connecting rooms with an open area between, with the following dimensions:( See Fig. 2, Example)
L1=15-1/2 Ft., L2=12 Ft., W=12 ft., H=8Ft
50
=52800 BTU/HR
If there were a door between the two rooms the calculation would be based only on the room with the heater.
BTU/HR=(15-1/2) x (12) x (8) x 1000
50
=29760 BTU/HR
When installing the appliance directly on carpeting, tile or other combustibleWhen installing the appliance directly on carpeting, tile or other combustible
When installing the appliance directly on carpeting, tile or other combustible
When installing the appliance directly on carpeting, tile or other combustibleWhen installing the appliance directly on carpeting, tile or other combustible material, other than wood flooring, the appliance must be installed on amaterial, other than wood flooring, the appliance must be installed on a
material, other than wood flooring, the appliance must be installed on a
material, other than wood flooring, the appliance must be installed on amaterial, other than wood flooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.metal or wood panel extending the full width and depth of the appliance.
metal or wood panel extending the full width and depth of the appliance.
metal or wood panel extending the full width and depth of the appliance.metal or wood panel extending the full width and depth of the appliance.
WARNINGWARNING
WARNINGWARNING
WARNING
FIGURE 2.FIGURE 2.
FIGURE 2.
FIGURE 2.FIGURE 2.
If the area in which the heater may be operated is smaller than that defined as anIf the area in which the heater may be operated is smaller than that defined as an
If the area in which the heater may be operated is smaller than that defined as an
If the area in which the heater may be operated is smaller than that defined as anIf the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provideunconfined space or if the building is of unusually tight construction, provide
unconfined space or if the building is of unusually tight construction, provide
unconfined space or if the building is of unusually tight construction, provideunconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in theadequate combustion and ventilation air by one of the methods described in the
adequate combustion and ventilation air by one of the methods described in the
adequate combustion and ventilation air by one of the methods described in theadequate combustion and ventilation air by one of the methods described in the National Fuel Gas CodeNational Fuel Gas Code
National Fuel Gas Code
WARNINGWARNING
WARNINGWARNING
National Fuel Gas CodeNational Fuel Gas Code
WARNING
Ensure the minimum clearances shown in FIGURE 3 are maintained forEnsure the minimum clearances shown in FIGURE 3 are maintained for
Ensure the minimum clearances shown in FIGURE 3 are maintained for
Ensure the minimum clearances shown in FIGURE 3 are maintained forEnsure the minimum clearances shown in FIGURE 3 are maintained for accessibility for purposes of servicing and proper operation. Left andaccessibility for purposes of servicing and proper operation. Left and
accessibility for purposes of servicing and proper operation. Left and
accessibility for purposes of servicing and proper operation. Left andaccessibility for purposes of servicing and proper operation. Left and right cright c
right c
right cright c
WARNINGWARNING
WARNINGWARNING
WARNING
FIGURE 3. Minimum ClearancesFIGURE 3. Minimum Clearances
FIGURE 3. Minimum Clearances
FIGURE 3. Minimum ClearancesFIGURE 3. Minimum Clearances
learances are determined when facing the frlearances are determined when facing the fr
learances are determined when facing the fr
learances are determined when facing the frlearances are determined when facing the fr
,,
ANSI Z223.1, ANSI Z223.1,
,
ANSI Z223.1,
,,
ANSI Z223.1, ANSI Z223.1,
Section 5.3, Section 5.3,
Section 5.3,
Section 5.3, Section 5.3,
Top of heater...............................36"
Right Side of heater.....................15"
Left Side of heater.........................8"
Front of heater.............................42"
Rear of heater...............................4"
or applicab or applicab
or applicab
or applicab or applicab
ont of the heateront of the heater
ont of the heater
ont of the heateront of the heater
Maintain these clearancesMaintain these clearances
Maintain these clearances
Maintain these clearancesMaintain these clearances to ensure adequate spaceto ensure adequate space
to ensure adequate space
to ensure adequate spaceto ensure adequate space around air opening foraround air opening for
around air opening for
around air opening foraround air opening for proper operation.proper operation.
proper operation.
proper operation.proper operation.
Minimum clearances to
combustibles:
le local codes.le local codes.
le local codes.
le local codes.le local codes.
..
.
..
7
MANTEL CLEARANCES
If placing a custom mantel above the heater, you must meet minimum clearances between mantel shelf and the top of the heater.
If your installation does not meet the below minimum clearances, you must:
• Raise the mantel to an acceptable height, OR
• Remove the mantel.
MINIMUM MANTEL CLEARANCESMINIMUM MANTEL CLEARANCES
MINIMUM MANTEL CLEARANCES
MINIMUM MANTEL CLEARANCESMINIMUM MANTEL CLEARANCES
Figure 4.Figure 4.
Figure 4.
Figure 4.Figure 4.
UNDERSIDE OF MANTEL SHELF
MANTEL SHELF
TOP OF HEATER
ALL MINIMUM
DISTANCES ARE
IN INCHES
DISTANCE TO
UNDERSIDE OF
MANTEL
BACK WALL
FLOOR
MINIMUM CLEARANCE
TO BACK WALL
8
GAS CONNECTION
A qualified gas appliance installer must connect the fireplace to the gas supply.A qualified gas appliance installer must connect the fireplace to the gas supply.
A qualified gas appliance installer must connect the fireplace to the gas supply.
A qualified gas appliance installer must connect the fireplace to the gas supply.A qualified gas appliance installer must connect the fireplace to the gas supply. Consult all local codes.Consult all local codes.
Consult all local codes.
Consult all local codes.Consult all local codes.
NOTICENOTICE
NOTICENOTICE
NOTICE
Use new black iron or steel pipe only. Internally tinned copper tubing can be usedUse new black iron or steel pipe only. Internally tinned copper tubing can be used
Use new black iron or steel pipe only. Internally tinned copper tubing can be used
Use new black iron or steel pipe only. Internally tinned copper tubing can be usedUse new black iron or steel pipe only. Internally tinned copper tubing can be used in some areas when permitted by local codes. Only use pipe of 1/2" or greaterin some areas when permitted by local codes. Only use pipe of 1/2" or greater
in some areas when permitted by local codes. Only use pipe of 1/2" or greater
in some areas when permitted by local codes. Only use pipe of 1/2" or greaterin some areas when permitted by local codes. Only use pipe of 1/2" or greater diameter to allow full gas volume to heater. Excessive pressure loss will occur if thediameter to allow full gas volume to heater. Excessive pressure loss will occur if the
diameter to allow full gas volume to heater. Excessive pressure loss will occur if the
diameter to allow full gas volume to heater. Excessive pressure loss will occur if thediameter to allow full gas volume to heater. Excessive pressure loss will occur if the pipe is too small.pipe is too small.
pipe is too small.
pipe is too small.pipe is too small.
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must beA manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be
A manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must beA manual shutoff valve, union and plugged 1/8" NPT pressure tapping point must be installed upstream of the heater (FIGURE 5).installed upstream of the heater (FIGURE 5).
installed upstream of the heater (FIGURE 5).
installed upstream of the heater (FIGURE 5).installed upstream of the heater (FIGURE 5).
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
A sediment trap must be installed upstream of the heater to prevent moisture andA sediment trap must be installed upstream of the heater to prevent moisture and
A sediment trap must be installed upstream of the heater to prevent moisture and
A sediment trap must be installed upstream of the heater to prevent moisture andA sediment trap must be installed upstream of the heater to prevent moisture and contaminants from passing through the pipe to the heater controls and burners.contaminants from passing through the pipe to the heater controls and burners.
contaminants from passing through the pipe to the heater controls and burners.
contaminants from passing through the pipe to the heater controls and burners.contaminants from passing through the pipe to the heater controls and burners. Failure to do so could prevent the heater from operating reliably (FIGURE 5).Failure to do so could prevent the heater from operating reliably (FIGURE 5).
Failure to do so could prevent the heater from operating reliably (FIGURE 5).
Failure to do so could prevent the heater from operating reliably (FIGURE 5).Failure to do so could prevent the heater from operating reliably (FIGURE 5).
IMPORTANT:IMPORTANT:
IMPORTANT: Loosen the pipe adapter
IMPORTANT:IMPORTANT:
on the flex tube before installing to the system piping.
FIGURE 5. Gas ConnectionFIGURE 5. Gas Connection
FIGURE 5. Gas Connection
FIGURE 5. Gas ConnectionFIGURE 5. Gas Connection
CHECK GAS TYPE:CHECK GAS TYPE:
CHECK GAS TYPE: The gas supply must be the same as stated on heater's rating plate. If the gas
CHECK GAS TYPE:CHECK GAS TYPE:
supply is different, DO NOT INSTALL the heater. Contact your dealer for the correct model.
Connecting directly to an unregulated propane/LPG tank can cause an explosion.Connecting directly to an unregulated propane/LPG tank can cause an explosion.
Connecting directly to an unregulated propane/LPG tank can cause an explosion.
Connecting directly to an unregulated propane/LPG tank can cause an explosion.Connecting directly to an unregulated propane/LPG tank can cause an explosion.
ARNINGARNING
ARNINGARNING
ARNING WW
WW
W
9
Loading...
+ 19 hidden pages