SAFETY PRECAUTIONS
IMPORTANT: Read this entire manual before
installing and operating this product. Failure
to do so may result in property damage, bodily
injury, or even death. Proper installation of
this stove is crucial for safe and efficient operation.
Install vent at clearances specified by the vent
manufacturer.
Do not connect the pellet vent to a vent serv-
ing any other appliance or stove.
Do not install a flue damper in the exhaust
venting system of this unit.
Use of outside air is required for this unit.
Contact your local building officials to obtain a
permit and information on any additional installation restrictions or inspection requirements in your area.
Do not throw this manual away. This manual
has important operating and maintenance instructions that you will need at a later time.
Always follow the instructions in this manual.
This heater is designed and approved for pre-
mium hardwood pellet fuel only. Any other
type of fuel burned in this heater will void the
warranty and safety listing.
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fluid, or similar liquids to start or ’freshen up’ a fire in this stove.
Keep all such liquids well away from the stove
while it is in use.
A working smoke detector must be installed in
the same room as this product.
The use of outside air is mandatory for safe
operation of this unit.
Do not unplug the stove if you suspect a mal-
function. Turn the ON/OFF SWITCH to ”OFF’
and contact your dealer.
Your stove requires periodic maintenance and
cleaning (see ”MAINTENANCE ”). Failure to
maintain your stove may lead to improper
and/or unsafe operation.
Disconnect the power cord before performing
any maintenance! NOTE: Turning the ON/OFF
Switch to ”OFF” does not disconnect all power
to the electrical components of the stove.
Never try to repair or replace any part of the
stove unless instructions for doing so are
given in this manual. All other work should be
done by a trained technician.
Allow the stove to cool before performing any
maintenance or cleaning. Ashes must be disposed in a metal container with a tight fitting
lid. The closed container of ashes should be
placed on a non-combustible surface or on the
ground, well away from all combustible materials, pending final disposal.
The exhaust system should be checked
monthly during the burning season for any
build-up of soot or creosote.
Do not touch the hot surfaces of the stove.
Educate all children on the dangers of a hightemperature stove. Young children should be
supervised when they are in the same room as
the stove.
The hopper and stove top will be hot during
operation; therefore, you should always use
some type of hand protection when refueling
your stove.
A power surge protector is required. This unit
must be plugged into a 110 - 120V, 60 Hz
grounded electrical outlet. Do not use an
adapter plug or sever the grounding plug. Do
not route the electrical cord underneath, in
front of, or over the heater. Do not route the
cord in foot traffic areas or pinch the cord under furniture.
The heater will not operate during a power
outage. If a power outage does occur, check
the heater for smoke spillage and open a window if any smoke spills into the room.
The feed door, hopper lid, and ash pan must be
closed and sealed during operation.
Never block free airflow through the open
vents of the unit.
-3-
SAFETY PRECAUTIONS
Keep foreign objects out of the hopper.
The moving parts of this stove are propelled
by high torque electric motors. Keep all body
parts away from the auger while the stove is
plugged into an electrical outlet. These moving parts may begin to move at any time while
the stove is plugged in.
Do not place clothing or other flammable
items on or near this stove.
When installed in a mobile home, the stove
must be grounded directly to the steel chassis
and bolted to the floor. WARNING—THIS
UNIT MUST NOT BE INSTALLED IN THE BEDROOM (per HUD requirements). CAUTION—
THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF
MUST BE MAINTAINED.
This appliance is not intended for commercial
use.
Note: United States Stove Company grants no warranty, implied or stated, for the installation
or maintenance of your stove, and assumes no responsibility of any consequential damage(s).
-4-
HEATING SPECIFICATIONS
1
Heat Output
Heating Capacity
Fuel Burn Rate
Burn Time (lowest setting) 24 hrs
38,000 BTU/hr
2
800 – 2,000 sq ft
3
1.5 – 4.7 lbs/hr
SPECIFICATIONS
Hopper Capacity 50 lbs
1
BTU output will vary depending on the quality of fuel. Use PFI listed fuels for the best results.
2
Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature.
3
Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates m ay vary by as much as 20%. Use PFI listed fuel for best re-
sults.
DIMENSIONS
Height 38 3/4 in
Width 24 1/4 in
Depth 25 3/4 in
Weight (empty) 280 lbs
ELECTRICAL SPECIFICATIONS
Electrical Rating 110-120 volts 60 HZ 3.0 amps
Watts (operational) 175 (approximately)
Watts (igniter running) 425 (approximately)
FUEL CONSIDERATIONS
Your
Ashley Heritage Model 5700
tion of Pellet Fuel Industries standards. (Minimum of 40 lbs density per cubic ft, 1/4” to 5/16” diameter, length no
greater than 1.5”, not less than 8,200 BTU/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). Pellets that are soft, contain excessive amounts of loose sawdust, have been, or are wet,
will result in reduced performance.
stove is designed to burn premium hardwood pellets that comply with Associa-
SAFETY AND EPA COMPLIANCE
Your
Ashley Heritage Model 5700
exempt from EPA Phase II requirements by OMNI-Test Laboratories, Inc. Beaverton, Oregon, USA.
stove has been safety tested and listed to ASTM E 1509, (UM) 84-HUD, and is
-5-
INSTALLATION
INSTALLATION OPTIONS
Read this entire manual before you install and use your
instructions may result in property damage, bodily injury, or even death!
(See specific installation details for clearances and other installation requirements)
Ashley Heritage
stove. Failure to follow
A Freestanding Unit
clearance requirements for a freestanding stove installation.
An Alcove Unit
requirements for an alcove installation.
Your
Ashley Heritage Model 5700
(see SPECIAL MOBILE HOME REQUIREMENTS
It is recommended that only a authorized technician install your
specialist.
IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the
malfunction of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer if you have any questions.
—supported by (4) legs and placed on a non-combustible floor surface in compliance with
—supported by (4) legs and placed on a non-combustible floor surface in compliance with clearance
stove may be installed to code in either a conventional or mobile home
).
Ashley Heritage
stove, preferably an NFI certified
FLOOR PROTECTION
This unit must be installed on a non-combustible floor surface. If a floor pad is used, it should be UL listed or equal.
The floor pad or non-combustible surface should be large enough to extend a minimum of 6-inches in front, 6inches on each side, and 1-inch behind the stove (see FIGURE 1).
Floor protection must extend under and 2-inches to each side of the chimney tee for an interior vertical installation
(see FIGURE 2).
Ashley Heritage Model 5700
Your
stove will need a minimum 36 1/4” x 30 3/8” floor protector.
THROUGH THE WALL INSTALLATION
FIGURE 1
FIGURE 2
INTERIOR VERTICAL INSTALLATION
-6-
INSTALLATION
CLEARANCES
Your Ashley Heritage Model 5700 stove has been tested and listed for installation in residential, mobile home, and
alcove applications in accordance with the clearances given in FIGURES 3-5 and TABLE 1.
NOTE: Distance “C” on the right-hand side of your
Ashley Heritage Model 5700
stove may need
to be greater than the minimum required clearance for suitable access to the control panel.
FIGURE 3
SIDEWALL CLEARANCES
PARALLEL INSTALLATION
FIGURE 4
SIDEWALL CLEARANCES
CORNER INSTALLATION
PARALLEL
CORNER
ALCOVE
A—BACKWALL TO UNIT 3 IN / 75 MM
B—SIDEWALL TO FLUE 12 IN / 305 MM
C—SIDEWALL TO TOP EDGE OF UNIT 10 IN / 254 MM
D—ADJACENT WALL TO UNIT 10 IN / 254 MM
E—ALCOVE DEPTH 36 IN / 914 MM
F—ALCOVE HEIGHT 60 IN / 1520 MM
TABLE 1
CLEARANCES
FIGURE 5
ALCOVE CLEARANCES
-7-
INSTALLATION
VENTING REQUIREMENTS
Install vent at clearances specified by the vent manufacturer.
Do not connect the pellet vent to a vent serving any other appliance or stove.
Do not install a flue damper in the exhaust venting system of this unit.
The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove
and to local building codes.
IMPORTANT! This unit is equipped with a negative draft system that pulls air through the burn pot
and pushes the exhaust out of the dwelling. If this unit is connected to a flue system other than the
way explained in this manual, it will not function properly.
MAXIMUM VENTING DISTANCE
Installation MUST include at least 3-feet of vertical pipe. This will create some natural draft to reduce the possibility
of smoke or odor during appliance shutdown and keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. The maximum recommend vertical venting height is 12-feet for 3-inch type
“PL” vent. Total length of horizontal vent MUST NOT exceed 4-feet. Use no more than 180 degrees of elbows (two
90-degree elbows, or two 45-degree and one 90-degree elbow, etc.) to maintain adequate draft.
PELLET VENT TYPE
A UL listed 3-inch or 4-inch type “PL” pellet vent exhaust system must be used for installation and attached to the
pipe connector provided on the back of the stove (use a 3-inch to 4-inch adapter for 4-inch pipe). Use 4-inch vent if
the vent height is over 12-feet or if the installation is over 2,500 feet above sea level.
®
We recommend the use of Simpson Dura-Vent
ing codes and/or building inspectors). Do not use Type-B Gas Vent pipe or galvanized pipe with this unit. The pellet
vent pipe is designed to disassemble for cleaning and should be checked several times during the burning season.
Pellet vent pipe is not furnished with the unit and must be purchased separately.
or Metal-Fab® pipe (if you use other pipe, consult your local build-
PELLET VENT INSTALLATION
The installation must include a clean-out tee to enable collection of fly ash and to permit periodic cleaning of the
exhaust system. 90-degree elbows accumulate fly ash and soot thereby reducing exhaust flow and performance of
the stove. Each elbow or tee reduces draft potential by 30% to 50%.
All joints in the vent system must be fastened by at least 3 screws, and all joints must be sealed with HI-TEMP RTV
silicone sealant to be airtight. The area where the vent pipe penetrates to the exterior of the home must be sealed
with silicone or other means to maintain the vapor barrier between the exterior and the interior of the home.
Vent surfaces can get hot enough to cause burns if touched by children. Noncombustible shielding or guards may be
required.
PELLET VENT TERMINATION
Do not terminate the vent in an enclosed or semi-enclosed area, such as; carport, garage, attic, crawl space, under
a sundeck or porch, narrow walkway, or any other location that can build up a concentration of fumes.
The termination must exhaust above the outside air inlet elevation.
The termination must not be located where it will become plugged by snow or other materials.
-8-
INSTALLATION
VENT TERMINATION CLEARANCES:
A) Minimum 4-foot clearance below or beside any door or window that opens.
B) Minimum 1-foot clearance above any door or window that opens.
C) Minimum 3-foot clearance form any adjacent building.
D) Minimum 7-foot clearance from any grade when adjacent to public walkways.
E) Minimum 2-foot clearance above any grass, plants, or other combustible materials.
F) Minimum 3-foot clearance from an forced air intake of any appliance.
G) Minimum 2-foot clearance below eves or overhang.
H) Minimum 1-foot clearance horizontally from combustible wall.
I) Must be a minimum of 36-inches above the roof and 24-inches above the highest point or the roof within 10-
feet.
I
B
C
H
A
F
E
A
F
D
FIGURE 6
VENT TERMINATION CLEARANCES
-9-