United Security Products SD-3, SD-2 Specsheet

NO TANGLED WIRES! - NO CONTROL UNITS! - NO HARDWARE! - NO BATTERY!
Revolutionary QUICK AND EASY USE DESIGN with Special “PAUSE” Feature
40 Years of Superior American Manufacturing • Made in U.S.A. • U.S. and Foreign Patents.
THE SENSOR AREA OF:
SD-2 Bed Standard is 18” x 24”
SD-3 Bed Large is 24” x 30”
Simply place Stand Down on Bed, under mattress
cover or sheet- Beneath patient Hip and upper legs.
as shown in Photo above.
Place and Operate or Remove in Seconds!
• Complete One Piece System
• No Tangled Wires, No Control Boxes & No Batteries to Replace
• Slip Resistant Surface
• Thin “Patient Comfort” Design
• Simply Place and Operate
• Nurse Call Station Output
• Alarm Volume Control
Wheel Chair, Bed and Floor Models Available
• Latex Free and Environmentally Friendly
• Moisture Proof - Quick Wipe Down.
• Folds for Easy Storage
• 1 Year Warranty from Date of First Use. Stand Down can be Stored up to 1 Year before First Use.
Slide selector Switch to desired position-
OFF - ON - PAUSE
Pause for low sound alert until patient is returned to bed
FALL PREVENTION AT IT’S BEST!
(T) 800-227-1592 • (F) 858-413-0124 • Email: sales@unitedsecurity.com • Web: www.emergencycaller.com
Bed Monitoring System
INSTRUCTIONS – QUICK START GUIDE
STAND DOWN is a completely self-contained bed monitoring
system. There are no plugs to connect, wires to route, or alert units to locate. Simply position the sensing pad, place patient, and move the tamper resistant slide selector switch to the ON position.
After non-bed activity is completed and patient has been
Positioned and laying in Bed, simply move the slide selec­tor from PAUSE, up position, back to ON, center position, to resume monitoring.
1. SYSTEM PLACEMENT
Locate Pad on Bed, under mattress cover or sheet ­located under patient hips and upper leg area. Route and Place the Extension Control Unit Outside of Bed at lower bed position. End of Extension Control Unit routed down toward floor ( see fig A above).
2. MONITORING
With patient positioned and laying in bed, hold the control
unit with one hand and move the slide selector from the OFF, or down position, to the ON, or center position. See Fig. B for slide selector location.
The system will not alarm as long as the patient remains
in bed. If the patient attempts to exit from bed, alarm will sound. When patient returns to Bed position, the system will automatically reset with no alarm sound and monitoring will resume. Alarm Volume may be adjusted with Alarm Volume Control.
3. END MONITORING SESSION
Locate slide selector and move it to OFF, or down
position.
4. STORAGE AFTER USE
The STANDDOWN monitoring system may be loosely
rolled, or loosely folded through its length for storage.
Please follow the instructions on the bottom of the Pad to avoid damage and voiding warranty.
5. CLEANING
STANDDOWN is moisture proof and may be cleaned with
standard healthcare disinfectants. Do not immerse in water.
6. TESTING AND E.O.L.
Caregivers should test the disposable STANDDOWN sys-
tem before each use by applying pressure to the Pad with their hand, moving the slide switch to ON, and removing hand pressure. If STANDDOWN fails to alarm, immediate replacement is required.
Thank you for choosing…
If a patient is being escorted from the bed to a Temporary
non-bed activity, the slide selector switch may be moved to the PAUSE, position. To remind caretaker to return se­lector switch to ON position when patient returns to Bed position.
In Pause position, the alert unit emits low-volume beeps
indicating that the system is “standing by” and neither monitoring (ON) or completely out-of-service (OFF).
If Nurse Call Station monitoring is desired, connect ac-
cessory cable to Nurse Call Output jack on Stand Down sensor pad, other end to Nurse Call Station using “Y” plug adapter accessory.