Route the 16AWG White Power Cord for the Transformer
5050PS
CVD-5050, CVD-5050P, CVD-
Cellular Voice/Dialer System INSTALLATION INSTRUCTIONS
TM
CVD-5050 is a complete four-channel monitoring system. Faults in N.O. or N.C. zone circuits prompt either cellular only, or landline backed by cellular calling of up to eight phone numbers sequentially. Pre­recorded messages, released when calls are answered, identify events specific to locations and conditions being monitored.
INPUT/OUTPUT PRE-WIRING PREPARATION
Knockouts are provided in the Cabinet for wire entry/exit when using metallic or non-metallic conduit, or other shielding.
Run wiring from monitoring devices (up to four) to the pre­determined Cabinet location. Be sure to mark wires N.O. or N.C. as required.
from a 120VAC outlet to the Cabinet location. Extend wire if necessary.
Route the cell phone charger wire from a nearby AC outlet to the Cabinet location. Extend wire if necessary.
If a bell, light, or siren is part of your system, you should route that wire to the Cabinet location at this time.
CABINET MOUNTING
The four teardrop holes in the back of the metal Cabinet can be used for surface mounting the Cabinet.
LISTEN IN / TWO-WAY AUDIO INSTALLATION
Determine a central location for the Audio Module; it can be wall or ceiling mounted. Make sure that you have determined the CVD-5050 Dialer location, and that it is within the Audio Cable length.
A template is supplied for drilling Mounting Anchor and Plug relief holes. Route the right angle Plug through a 1” hole and insert the Plug into the Audio Module jack. Install supplied Anchors, and mount the Audio Module. Run the Audio Cable (conceal) to the CVD-5050 Dialer.
Refer to the CVD-5050 User Manual and CVD-5050 Supplement for complete “how to” instructions regarding Listen In and Two-Way audio features.
INPUT/OUTPUT CONNECTIONS
A Wiring Diagram on the Cabinet door identifies all necessary and optional connections. The suggested connection sequence is as follows:
1. Connect inputs to the Channels 1 through 4 terminals on the Terminal Block.
2. Connect local alarm device (Bell, Light, Siren, etc.) to +12VDC and + AUX Output Terminals.
3. Connect ends of the 16AWG White Power Cord to the Mini Controller, AC Input. Connect other ends of 16AWG White Power Cord (routed to AC outlet) to the Transformer outer terminals marked AC.
4. Plug cell phone charger wire into cell phone.
5. Connect an “in cabinet type” backup battery (see COM- PONENT IDENTIFICATION) by pushing the Red and Blue Connectors, routed from the Mini Controller Location Battery Rechargeable, onto the battery posts. A standard 12V, 7.0Ah battery is recommended. Battery is not supplied with the System.
Note: 12V backup (battery in cabinet or other source)
supplies power to the Cell Phone Docking Module and the Dialer during a power outage.
CELL PHONE DOCKING (PARING)
If you have CVD-5050P or CVD-5050PS, make sure that all power connections are completed (power up System) and then proceed to Dialer PROGRAMMING NOTES.
If you have a CVD-5050 model, “your” cell phone must be paired to the Cell Phone Docking Module.
1. Make sure that all power connections are completed: Power up System.
2. Hold down the button (marked with a single dot) on the Docking Module until it starts flashing.
3. Enable Bluetooth on your phone, or search for Bluetooth, or “Handsfree” devices, or search for headsets.
4. Select XLink Gateway.
5. Enter PIN when prompted. See label on Cell Phone Docking Module for PIN code. Note: When paring is complete, the button light (marked with single dot) turns to solid green.
Proceed to Dialer PROGRAMMING NOTES.
LANDLINE CALLING WITH CELLULAR BACKUP
The system can use a landline as the primary connection and cellular service as backup. If the landline is disrupted or cut, the system will immediately switch to cellular.
To enable landline, Route a telephone cord (RJ11 to RJ11) from the lower RJ11 jack on the Cell Phone Docking Module (marked with telephone pole symbol) to a telephone wall jack.
PROGRAMMING NOTES
Complete programming instructions for the CVD-5050 Dialer are found in its User Manual.
Please pay attention to N.O. or N.C. when setting up channels or zones.
When entering phone numbers, remember to enter a # symbol after the last phone number digit. A # symbol is required to make the cell phone dial.
To leave a message, include three pauses after the # symbol.
For pagers, program for a regular phone number and after the # symbol insert five pauses followed by the return call number and the # symbol.
If installation and programming are completed, proceed to testing the system by simulating channel or zone event.
NOTE
The Dialer is Velcro mounted and can be pulled out for programming.
Dialer
COMPONENT IDENTIFICATION
See below.
Audio Module
Thank you for choosing…
Audio Cable
40 Years of Superior American Manufacturing
Made in U.S.A
(T) 800-227-1592
(F) 858-413-0124
Email: sales@unitedsecurity.com Web: www.unitedsecurity.com
Cell Phone Docking Module
Terminal Block
16AWG White Power Cord
Cell Phone included with CVD-5050P and CVD-5050PS
Battery not included with Systems
Mini Controller
Transformer
Cell Phone Holder
REV. 02.12