Model Numbers:
GR1-06-18
GR1-06-24
GR1-14-18
GR1-14-24
2
IMPORTANT SAFETY INSTRUCTIONS
This document contains instructions and warnings that must be followed when installing
and using the Electric Vehicle Supply Equipment (EVSE). Before installing or using the EVSE,
read this entire document as well as WARNING and CAUTION markings in this document.
The symbols used have the following meaning:
Warning: risk of personal injury
Warning: risk of electric shock
• The charging station must be installed, adjusted, and repaired only by a licensed
electrician.
• Make sure that the materials used, and the installation procedures follow local building
codes and safety standards.
• The information provided in this manual in no way exempts the user of responsibility to
follow all applicable codes or safety standards.
• This document provides instructions for the charging station and should not be used for
any other product. Before installation or use of this product, review this manual carefully and
consult with a licensed contractor, licensed electrician, or trained installation expert to make
sure of compliance with local building codes and safety standards.
• CAUTION: To reduce the risk of fire, connect only to a circuit provided with the minimum
branch circuit overcurrent protection requirements in accordance with the National Electrical
Code, ANSI/NFPA 70, and the Canadian Electrical Safety Code, Part I, C22.1.
Warning: risk of fire
Caution: risk of damage to
the equipment
Repair and Maintenance Clause
• All United Chargers products do not require routine maintenance however, periodic
inspections should be conducted to ensure that all parts remain in good working order and
no damage exists. Do not attempt to open, disassemble, repair, tamper with, or modify
any components of the products – the products are not user serviceable. Contact United
Chargers for any repairs.
• Only licensed electricians can repair or maintain the charging station. It is forbidden for
general users to repair or maintain it. Turn off input power before performing any repairs or
maintenance to the charging station.
FCC Declaration of Conformity
• This charging station complies with part 15 of the FCC Rules. Changes or modifications the
charging station not expressly approved by the manufacturer could void FCC compliance.
3
• Operation is subject to the following two conditions: (1) This charging station may not cause
harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
OVERALL WARNINGS & CAUTIONS
Warning: risk of electric shock
Basic precautions should always be followed when using electrical products,
including the following:
• Read all the instructions before using this product.
• This device should be supervised when used around children.
• Do not put fingers into the EV connector.
• Do not use this product if the flexible power cord or EV cable is ragged, has broken
insulation, or any other signs of damage.
• Do not use this product if the enclosure or the EV connector is broken, cracked, open,
or shows any other indication of damage.
• Improper connection of the equipment grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the
product is properly grounded.
• Do not touch live electrical parts.
• Incorrect connections may cause electric shock.
WARNING: This equipment is intended only for charging vehicles that do not require
ventilation during charging. Please refer to your vehicle’s owner’s manual to determine
ventilation requirements.
4
PRODUCT FEATURES
United Chargers GRIZZL-E™ Electric Vehicle Charging Station (EVSE)
• Adjustable Maximum Current Output (40A, 32A, 24A, 16A) to Support Multiple Circuit
Ratings (50A, 40A, 30A, 20A)
• Extreme Duty, Rigid & Compact Design:
EVSE form factor smaller than a standard sheet of letter-size paper
• Robust Construction, designed for Outdoor Use:
Robust and heavy duty aluminum cast case; airtight enclosure for indoor or outdoor use.
• Simple Operation:
No user interface required with EVSE, simply Plug-in to your EV to initiate charging
• Cable & Connector Management:
EasyEvPlug™ with cable Management System.
• Portable:
Standard NEMA 6-50 (Models GR1-06-18 and GR1-06-24)
or NEMA 14-50 (Models GR1-14-18 and GR1-14-24)
Plug-in Configuration for easy portability depending on model.
• Simple, Flexible Mounting Options:
Wall Mount with security features (including single stud mount), Pedestal, Bollard/Pole
(Single & Dual Port) available from United Chargers.
• UL certified components.
Adjustable Maximum Current Output to Support Multiple Circuit Ratings
The GRIZZL-E ™ charging station product features the ability to adjust the maximum Charging
Station current output to allow the use of a 50A, 40A, 30A, or 20A Dedicated Circuit as follows:
50A Circuit Rating: To support 40A (9.6 kW) maximum Charging Station output
40A Circuit Rating: To support 32A (7.68 kW) maximum Charging Station output
30A Circuit Rating: To support 24A (5.76 kW) maximum Charging Station output
20A Circuit Rating: To support 16A (3.84 kW) maximum Charging Station output
Notes on Circuit Requirements and Amperage settings:
• The Charging Station Default Factory Maximum Current Output Setting is 40A (9.6 kW) for
use with a 50A Circuit Rating – Please refer to Adjusting Maximum Current Output on page
12 when using a 40A or 30A or 20A Circuit Rating.
5
• To obtain the fastest charging capability of 40A, a 50A Circuit Rating must be used.
• The Circuit must be a DEDICATED CIRCUIT 208-240 VAC, 50-60 Hz, Single Phase.
• Per only 80% of the circuit rated load may be utilized, hence the higher Circuit Ratings
Requirement relative to maximum Charging Station output.
The ability to utilize alternate circuit ratings can be beneficial in the instance the location
of installation cannot support a 50A circuit, or in instance where an existing 40A
or 30A or 20A dedicated circuit is already installed.
Security and Tamper Feature
In addition to the pin that secures the GRIZZL-E ™ charging station to the wall mount bracket
(Refer to Section 2.3, Paragraph 3., Installing the Charging Station), if desired, a feature is
included as part of the charging station and wall mount bracket to replace provided pin with
the coupler lock with the minimum parameters:
Length: 90mm, Diameter: 7mm
for added security and tamper benefits.
Self-Monitoring and Recovery | Power Outage Recovery
When a charging session is interrupted due to a temporary error condition, the charging
station will automatically restart charging when the cause of the temporary error condition
returns to normal. The status indicator lights remain flashing RED until the error condition
is resolved.
• Temporary error condition include: Overcurrent, Overvoltage, Undervoltage, Missing diode,
Ground fault and Over Temperature.
• For Over Current (OC) conditions: The charging session will be stopped while OC occurs.
After recovery from OC for 30 seconds, the charging station will automatically restart charging
for 4 times.
• When charging session stopped due to Ground Fault (GFCI) trip, the charging station will
try to restart after 15 minutes for 4 times. After 4 times, the charging station buzzer will stay
on continuously, and status indicator will stay RED. The user should plug-out and plug-in the
power cable of the charging station.
6
PRODUCT SPECIFICATIONS
United Chargers GRIZZL-E™ Electric Vehicle Charging Station (EVSE)
DescriptionSpecifications
Model Numbers
Connector / EVSE
Level
Max Output
Rating
Alternate
Adjustable Output
Ratings
Charge Cable
Lengths
Electrical Circuit
/ Input Power
Requirements
Input Power
Connection
GR1-06-18: GRIZZL-E
GR1-06-24: GRIZZL-E
GR1-14-18: GRIZZL-E
GR1-14-24: GRIZZL-E
™ EVSE, 18 ft. J1772 Cordset, Plug-in: NEMA 6-50 Plug
™ EVSE, 24 ft. J1772 Cordset, Plug-in: NEMA 6-50 Plug
™ EVSE, 18 ft. J1772 Cordset, Plug-in: NEMA 14-50 Plug
™ EVSE, 24 ft. J1772 Cordset, Plug-in: NEMA 14-50 Plug
SAE J1772; AC Level 2
40A; 9.6 kW Maximum Output – For use with 50A Circuit Rating
32A; 7.68 kW Maximum Output – For use with 40A Circuit Rating
24A; 5.76 kW Maximum Output – For use with 30A Circuit Rating
16A; 3.84 kW Maximum Output – For use with 20A Circuit Rating
18 ft. (5.5m) for GR1-06-18 and GR1-14-18
24 ft. (7.2m) for GR1-06-24 and GR1-14-24
Circuit Requirement: Dedicated Single Phase 208-240VAC, 50/60 Hz.;
Branch Breaker: Double pole;
Circuit Conductors: Line 1, Line 2, Earth / Ground
Standard: Plug-in, NEMA 6-50 or NEMA 14-50 Plug.
Plug is removable for Hardwire Connection.
Charging Station
Color
Installation Rating
Operational Ratings
Mounting
Overall Dimensions
Display & Indicators
Standard: Black
NEMA 4, Indoor/Outdoor Rated
Temperature: -22⁰F to 122⁰F (-30⁰C to 50⁰C); Humidity: 95% RH
non-condensing
Wall or Pedestal Installation
EVSE: 10.25 x 6.25 x 3.75 inches (26.0 x 16.0 x 9.3 cm)
LED Charge Status Indicators (Power/Ready, Charging, Fault)
7
Cable Management
EasyEvPlug™ with cable management
Standards &
Compliance
UL certified components
8
Loading...