Installation Manual - FPLC V2 SLIM
hank you for purchasing a FPLC V2 SLIM lift!
Please make sure to read the instructions mentioned below before installing and using this lift!
FPLC V2 Slim mechanism is manufactured for flat panel installation on ceiling in horizontal position and should be installed by specialized installers.
FPLC V2 Slim must be firmly installed on the ceiling with the use of metal screws and the appropriate for the ceiling anchors. The ceiling surface on which the FPLC V4 will be installed, must be able to bare 3 times the total weight of the application: lift weight + weight of the flat panel +weight of the ceiling cover.
Lift wei
ht: FPLC V2 30-40 = 60kg FPLC V2 42-50 = 72k
FPLC V2 52-60 = 84k
The FPLC V2 slim lift must be mounted through the 4 slat holes shown in the drawing beside, with the use of (4) four M10 screws with washer.
he hole pattern is: FPLC V2 30-40 : 990x695mm FPLC V2 42-50 : 1247x831mm
FPLC V2 52-60 : 1447x961mm
ortant Note:
Im
The lift must be firmly, well balanced and tightly mounted on the ceiling, so that there will be no oscillation during opening and closing of the lift. In cases when the ceiling has big depth, then special over constructions of metal or other firm structure must be applied before the lift is installed, in order to achieve lift's firm mounting.
Important Note:
he distance between the back side of the lift and the back side of the false ceiling box (if applicable) must be at least 20mm in order to have enough room for the ceiling cover to rotate inside the false ceiling (see drawing beside).
Ceiling hole recommended dimensions:
FPLC V2 30-40 : 1495x820mmFPLC V2 42-50 : 1752x956mmFPLC V2 52-60 : 1952x1086mm
The flat panel must be mounted, aligned and centred, on the two vertical bars shown in the drawing beside, after they are adjusted in the appropriate distance, in order to feet the vesa mounting of the screen.
page 1/3
FPLC V2 Slim: Installation manual
g
p
g
p
g
T
The ceiling cover is recommended to be from phenol­marine plywood of 8mm or 12mm and it must be mounted on the metal frame indicated in the drawing beside.
It is recommended that the lift cell is not drilled by other
teams in the project site.
workin
If for any reason this must be done, in order to complete false ceiling installation works, it must not be done in areas marked by signs "No drilling area"!
After the flat panel and the ceiling cover are firmly installed on the lift, then it is the right time to adjust the opening and closing angles of it.
o
FPLC V2 Slim has a maximum opening angle of 110
. The degrees of the opening angle can be reduced by the specialized installer:
Open the "angle control box" in the left inner side of the
lift, by unscrewing the (4) four screws that hold it.
Control the opening angle by turning the two rosettes
to the appropriate direction.
Upper rosette marked as UP controls the maximum
opening angle and lower rosette marked as DOWN controls the closing angle of the lift (see drawing at the side).
Caution:
The maximum weight of flat panel and ceiling over must not exceed the load capacity of FPLC V2 Slim lift!
Maximum load ca
acity for FPLC V2 30-40 : 30k Maximum load capacity for FPLC V2 42-50 : 35kg Maximum load ca
Attention: In order for the lift to be able to reach the full
opening position at 110
acity for FPLC V2 52-60 : 45k
o
, it is required that the back side of the lift has a minimum distance from the wall or other vertical surface that exists behind the area that the lift is installed.
his minimum distance is :
- 180mm for FPLC V2 Slim 30-40
- 240mm for FPLC V2 Slim 42-50
- 260mm for FPLC V2 Slim 52-60