Model No. : UT-101 F
z
OPERATION MANUAL
z
UNIVERSAL PROCESS INDICATOR / CONTROLLER
Model No. : UT-101 F
CH-1
AL-1
AL-1
CH-1
AL-2
AL-2
M
O
C
-1
L
A
“Sure for service with hi-end versal nology”Uni Tech
Add.-503/504,Helix Complex , Opp. Surya Hotel, Sayajigunj, Vadodra-05. Gujrat. INDIA, PH-0265 6623551
+91 94273 01436
Sales: Email :
Website:
www.unitechinstrument.com
Sales@unitechinstrument.com
Model No. : UT-101 F
UNIVERSAL INDICATOR/CONTROLLER
F
F
F
F
F
F
F
F
F
F
F
zz
INTRODUCTION
FRONT PANEL DESCRIPTION
TECHNICAL SPECIFICATION
INSTALLATION
TERMINAL ARRANGEMENT
PROGRAMMING FLOW CHART
OPERATION 5
ERROR MESSAGE AND TROUBLESHOOTING 8
PANEL CUTOUT 9
zz
CONTENTS
1
2
3
3
4
9REGISTER ADDRESS FOR MODBUS
9CALIBRATION VALUES
INTRODUCTION
Unitech Instrument’s Universal Indicator is designed to
accept thermo-couple or RTD or Linear Input and displays the
process parameter through a 4 Digit Red LED Display.
The instrument is available in a panel mounted housing which
requires a cut out as per Panel cutout Dimensions given later .
A variety of power supply options are available for this. The
instrument has low drift precision components for long trouble
free operation. The instrument is a jumper less system. There are
different types of modes such as normal mode, operation mode,
configuration mode, setup mode, and change password mode.
4 keys provided can do any change in the mode.
The instrument can be configured for RTD or Thermocouple or
Linear input by making changes in configuration mode using 4
keys provided. This instrument can operate with full range for all
inputs.
“Sure for service with hi-end versal nology”Uni Tech
“Sure for service with hi-end versal nology”Uni Tech
Add.-503/504,Helix Complex , Opp. Surya Hotel, Sayajigunj, Vadodra-05. Gujrat. INDIA, PH-0265 6623551
Add.-503/504,Helix Complex , Opp. Surya Hotel, Sayajigunj, Vadodra-05. Gujrat. INDIA, PH-0265 6623551
+91 94273 01436
+91 94273 01436
Sales: Email :
Sales: Email :
Website:
Website:
www.unitechinstrument.com
www.unitechinstrument.com
Sales@unitechinstrument.com
Sales@unitechinstrument.com
Model No. : UT-101 F
PAGE:1
SR
NO
1
zz
DISPLAY
8888
FRONT PANEL DESCRIPTION
*C
*C
AL-1 AL-2
COM.
UT-101 F-F
UT-101 F-F
DESCRIPTION
PV
Seven Segment LED display
SR
2
3
4
5
8
9
10
NO
PV
AL1
AL2
COM
KEY
M
Actual Process Value
Red LED will glow on Relay 1 activation. (If Applicable)
Red LED will glow on Relay 2 activation. (If Applicable)
Red LED will blink when there is communication.
(If Applicable)
PARTICULAR
DESCRIPTION
Press to access the programmable
FUNCTION(M)
Parameter.
(UP)
Press to increase selected digit or value
in Programming Mode.
Press to change digit selection or selected
(PASS)
value in Programming Mode.
11
ENTER
Press to accept modified digit or
in Programming Mode.
Press to Change Set point Value. Change up
12
Add.-503/504,Helix Complex , Opp. Surya Hotel, Sayajigunj, Vadodra-05. Gujrat. INDIA, PH-0265 6623551
+91 94273 01436
Sales: Email :
M
“Sure for service with hi-end versal nology”Uni Tech
Set Point
Website:
www.unitechinstrument.com
and down when decimal dot blinking
Sales@unitechinstrument.com
value
Model No. : UT-101 F
PAGE:2
z
TECHNICAL SPECIFICATION
INPUT
TYPE RANGE RANGETYPE
Technical Specification
Input Type
Special on demand :
Input
Transmitter power supply
Cold junction comp. & Sensor break ind.
Range limits
Accuracy
Input impedance
Indication
Indication
Status indication
z
4 to 20mA -1999 to 9999K-Type T/C -50 to 1200 ºC
0 to 20mA -1999 to 9999J-Type T/C -50 to 750 ºC
0.5 to 2.5V -1999 to 9999R-Type T/C 0 to 1750 ºC
1 to 5V -1999 to 9999S-Type T/C 0 to 1750 ºC
0 to 10VDC -1999 to 9999T-Type T/C 0 to 400 ºC
SPECIAL -1999 to 9999E-Type T/C -50 to 500 ºC
Cu 53 -50 to 250 ºCRTD PT-100 -50 to 400 ºC
T/C
RTD
Currant
Voltage
200 mV 1000- /300V DC
24 V DC @ 30 mA max, isolated from I/p & O/P.
Software base Automatic.
As per input range Table.
+L+0.1 % of span for inear & RTD , 0.25 % for T/C
>330 K for Voltage ,mV, and T/C, 100 for current.ΩΩ
4 Digit 7 Segment display 0.56”
LEDs for Relay status & Communications
.
K, J, R, S, E, N, T
.
.
.
Pt100, Cu53 ( 2wire & 3 wire)
.
.
0 ~ 20mA dc , 4~20mA DC
.
.
0-5V/1-5V, 0.5 -2.5V/0- DC10 V
0- & 0- /300/V DC,0-75/75/200 mV 1/10V/100
Resistence
.
.
0-500 Ω , 0-1/5/10 KΩ, 1MΩ
Control Mode
Output
Comunication
Programmable
Parameters
Other
(A) (B)Supply voltage Power consumption
On Off control
Dead Band controls
Relay Output
SSR Output
Retransmition Current & Voltage outputs
Communication Protocol & mathode
Programeble parameter & Connectable number
Wireless comunication
Setpoint / Hysteresis / High scale / Low scale
Relay logic
Display resolution
Programming of parameters
(A) (B) (C)Dimensions Panel cutout Mounting
Operating ambient temperature and humidity
Relay / SSR
High and Low Set point for level applications.
NO - C - NC Contacts , 5A@240 V AC Resistive
1/2/3/4Relays/SSRoutput
24VDC @ 20 mA ,12VDC @ 20 mA
0~20/ 4~20 mA,
Modbus RTU RS- 485/RS- 232 communications.
Baud rate , Node, Parity , nodeaddress , stop bit. & 0-256 unit.
GSM/GPRS base mobile(sms) communications.
Full range as per input selection.
F.S. igh & owH L alarm
-1.999 to 9999 fully configurable for linear input
Through 4 tactile keys
(A) (B) (C)96(H) x 96(W) x 100(D) 92 x 92 Panel mounted
0~50 °C
0~5V, 0~10V, 1~5V DC, fully 3 port isolated
Deadband alarm.
V AC, 50/60 Hz 4 watts maximum(A) 110/230 (B)
Below 90%, non condensing
“Sure for service with hi-end versal nology”Uni Tech
Add.-503/504,Helix Complex , Opp. Surya Hotel, Sayajigunj, Vadodra-05. Gujrat. INDIA, PH-0265 6623551
+91 94273 01436
Sales: Email :
Website:
www.unitechinstrument.com
Sales@unitechinstrument.com