Unitech MS250 User Manual

Page 1
CCD Barcode Scanner
- MS250 -
Version 2.0
Page 2
I
Disclaimer
Unitech reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Unitech to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Unitech.
Unitech shall not be liable for technical or editorial errors or omissions contained herein: nor for incidental or consequential damages resulting from the furnishing, performance, or use of this manual.
This document contains propriety information that is protected by copyright. All rights reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Unitech.
© 2013 Unitech. All rights reserved.
Trademarks
Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are the property of their respective owners.
Regulatory Compliance Statements
RoHS Statement
This device conforms to RoHS (Reduction Of Hazardous Substances) European Union regulations that set maximum concentration limits on hazardous materials used in electrical and electronic equipment.
Page 3
II
Table of Contents
Disclaimer ................................................................................................................... I
Trademarks ................................................................................................................. I
Regulatory Compliance Statements ............................................................................ I
Table of Contents ....................................................................................................... II
Chapter 1. Quick Tour ................................................................................................ 1
Chapter 2. Installation and Operation ........................................................................ 2
Chapter 3. CONFIGURATION ................................................................................... 3
3.1 Flow Chart .................................................................................................... 3
3.2 Loop of Programming ................................................................................... 4
3.3 Factory Default Settings................................................................................ 4
3.4 Main Page of Configuration .......................................................................... 4
Chapter 4 Interface and Reading Mode Selection ..................................................... 6
4.1 Interface SeIection ........................................................................................ 6
4.2 Reading Mode Selection ............................................................................... 6
Chapter.5 Communication Parameters ...................................................................... 8
5.1 RS232 Communication Parameters ............................................................. 8
5.2 Keyboard Wedge Mode Parameters ........................................................... 10
5.3 Output Characters Parameters ................................................................... 13
5.4 Wand Emulation Mode Parameters ............................................................ 15
Chapter. 6 Bar Codes & Others ............................................................................... 16
6.1 SymboIogies Selection ............................................................................... 16
6.2 UPC/EANI/JAN Parameters ........................................................................ 20
6.3 Code 39 Parameters ................................................................................... 23
6.4 Code 128 Parameters ................................................................................. 25
6.5 Interleave 25 Parameters............................................................................ 27
6.6 IndustriaI 25 Parameters............................................................................. 29
6.7 Matrix 25 Parameters ................................................................................. 31
6.8 CODABAR/NW7 Parameters ...................................................................... 32
6.9 Code 93 Parameters ................................................................................... 35
6.10 Code 11 Parameters ................................................................................. 36
6.11 MSI/PLESSEY Code Parameters ............................................................. 38
6.12 LCD25 Parameters ................................................................................... 39
6.15 GS1 Databar ............................................................................................. 42
Chapter 7 Miscellaneous Parameters ...................................................................... 44
Page 4
III
7.1 Language Selection .................................................................................... 44
7.2 Bar Code ID ................................................................................................ 45
7.3 Reading Level ............................................................................................. 48
7.4 Accuracy ..................................................................................................... 48
7.5 Buzzer Beep Tone....................................................................................... 49
7.6 Sensitivity of Continuous Reading Mode .................................................... 49
7.7 Reverse Output Characters ........................................................................ 50
7.8 Setup Deletion ............................................................................................ 50
7.9 Setup Insertion ........................................................................................... 54
Appendix A Decimal Value Table .............................................................................. 58
Appendix B ASCII Table ........................................................................................... 58
Appendix C Function Key Table ............................................................................... 62
8 SPECIFICATION ................................................................................................... 63
8.1 Dimensions ................................................................................................. 63
8.2 Technical Data ............................................................................................ 64
8.3. Readable Symbology ................................................................................. 65
8.4. Reliability ................................................................................................... 66
Page 5
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
1
Chapter 1. Quick Tour
Page 6
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
2
Chapter 2. Installation and Operation
1. Connect the USB connector of MS 250 to the USB port of a host PC.
2. Aim at the barcode and pull the trigger to scan the barcode.
Page 7
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
3
Chapter 3. CONFIGURATION
3.1 Flow Chart
Page 8
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
4
3.2 Loop of Programming
The philosophy of programming parameters has been shown on the flow chart of 2.1. Basically user should
1. Scan Start of Configuration.
2. Scan all necessary labels for parameters that meet applications.
3. Scan End of Configuration to end the programming.
4. To permanently save the settings you programmed, just scan label for Save Parameters. To go back to the Default Settings, just scan label for Set All Defaults.
3.3 Factory Default Settings
The factory default settings are shown with <> and bold in the following sections. You can make your own settings by following the procedures in this manual. If you want to save the settings permanently, you should scan the label of “Save Parameters“ in chapter 2.4,otherwise the settings will not be saved after the decoder power is off, and all settings will go back to previous settings.
By scanning “Set All Default“ label, the settings will go back to the factory default settings.
3.4 Main Page of Configuration
Set AII Defaults
Start Configuration
End Configuration
Abort Configuration
Version Information
Page 9
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
5
Save Parameters -
The parameter settings will be saved permanently. Recall Stored Parameters -
Replace the current parameters by the parameters you saved last time. Set AII Defaults -
Set all the parameters to the factory default settings. Abort Configuration -
Terminate current programming status. Version Information -
Display the decoder version information and date code.
Page 10
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
6
Chapter 4 Interface and Reading Mode Selection
4.1 Interface SeIection
<USB Mode>
Keyboard Mode
RS232 Mode
WAND Emulation
Virtual Com Port Mode
4.2 Reading Mode Selection
<Trigger ON/OFF>
Good Read OFF
Continuous/Trigger OFF
Testing
Page 11
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
7
Continuous/Auto Power On
Flash
Flash/Auto Power On
Reserved1
Auto Sense (Option)
Reserved3
Reserved4
Reserved5
Page 12
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
8
Chapter.5 Communication Parameters
5.1 RS232 Communication Parameters
A. Set
Up
BAUD Rate
1200
2400
4800
<9600>
19200
38400
B. Set Up Data Bits
7 Data Bits
<8 Data Bits>
Page 13
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
9
C. Set Up Stop Bits
<1 Bit>
2 Bits
D. Set Up Parity
<None>
Even
Odd
Mark
Space
E. Handshaking
RTS/CTS Enable
<RTS/CTS Disable>
Page 14
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
10
ACK/NAK Enable
<ACK/NAK Disable>
XON/XOFF Enable
<XON/XOFF Disable>
5.2 Keyboard Wedge Mode Parameters
A. Terminal Type
<IBM PC/AT, PS/2>
IBM PC/XT
IBM PS/2 25, 30
NEC 9800
Apple Desktop Bus(ADB)
Page 15
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
11
IBM 5550
IBM 122 Key (1)
IBM 102 Key
IBM 122 Key (2)
Reserved 1
Reserved 2
Reserved 3
Reserved 4
Reserved 5
Page 16
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
12
B. Upper/Lower Case
<No Change>
Upper Case
Lower Case
C. Caps Lock Detection
Enable
<Disable>
D. Send Character by ALT Method
Enable
<Disable>
Page 17
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
13
E. Select Numerical Pad
ON
<OFF>
5.3 Output Characters Parameters
A. Select Terminator
<CR+LF>
None
CR
LF
Space
HT(TAB)
STX-ETX
Page 18
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
14
B. Time-out Between Characters
<0 ms>
5 ms
10 ms
25 ms
50 ms
100 ms
200 ms
300 ms
Page 19
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
15
5.4 Wand Emulation Mode Parameters
A. TTL Level Representation
<Bar Equals High>
Bar Equals Low
B. Scan Speed Selection
<Fast>
Slow
C. Output Format Selection
<Output as Code 39>
Output as Code 39 Full ASCII
Output as Original Code Format
Page 20
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
16
Chapter. 6 Bar Codes & Others
6.1 SymboIogies Selection
UPC-A <ON>
OFF
UPC-E <ON>
OFF
EAN-13/JAN-13/ISBN-13<ON>
OFF
EAN-8/JAN-8 <ON>
OFF
CODE 39 <ON>
OFF
Page 21
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
17
CODE 128 <ON>
OFF
CODABAR/NW7 <ON>
OFF
Interleave 25 <ON>
OFF
Industrial 25 ON
<OFF>
Matrix 25 ON
<OFF>
Page 22
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
18
CODE 93 ON
<OFF>
CODE 11 ON
<OFF>
China Postage ON
<OFF>
MSI/PLESSEY ON
<OFF>
Code 2 of 6 ON
<OFF>
Page 23
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
19
LCD25 ON
<OFF>
Reserved5 ON
<OFF>
Reserved6 ON
<OFF>
GS1 DataBar Omnidirectional ON
<OFF>
GS1 DataBar Limited ON
<OFF>
GS1 DataBar Expanded ON
Page 24
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
20
<OFF>
Select All Bar Codes
6.2 UPC/EANI/JAN Parameters
A Reading Type
UPCA=EAN13 ON
UPCA=EAN13<OFF>
ISBN-1C Enable
ISBN-13 <Enable>
ISSN Enable
ISSN <Disable>
Decode with Supplement
Page 25
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
21
<Auto discriminate Supplement>
Expand UPC-E Enable
Expand UPC-E <Disable>
EAN8=EAN13 Enable
EAN8=EAN13 <Disable>
GTIN Format Enable
GTIN Format <Disable>
B Supplemental Set Up
<Not Transmit>
Transmit 2 Code
Transmit 5 Code
Page 26
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
22
Transmit 2&5 Code
C Check Digit Transmission
UPC-A Check Digit Transmission <ON>
OFF
UPC-E Check Digit Transmission <ON>
OFF
EAN-8 Check Digit Transmission <ON>
OFF
EAN-13 Check Digit Transmission <ON>
OFF
Page 27
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
23
ISSN Check Digit Transmission <ON>
OFF
6.3 Code 39 Parameters
A Type of Code
<Standard>
Full ASCII
Italian Pharmacy/Code 32 <OFF>
Italian Pharmacy/ Code 32 ON
B Check Digit Transmission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
Page 28
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
24
C Output Start/Stop Character
Enable
<Disable>
D Decode Asterisk
Enable
<Disable>
E Set Up Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin
2. Decimal Value (See Appendix A)
Page 29
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
25
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin
2. Decimal Value (See Appendix A)
3. Complete
6.4 Code 128 Parameters
A Reading Type
UCC/EA1-128 Enable
<UCC/EA1-128 Disable>
<Enable’]C1’Code Format>
Disable‘]C1‘Code Format
Page 30
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
26
<Enable Code128 Group Separators(GS)>
Disable Code128 Group Separators(GS)
B Check Digit Transmission
Do Not Calculate Check Digit
Calculate Check Digit & Transmit
<Calculate Check Digit& Not Transmit>
C Append FNC2
ON
<OFF>
D Set Up Code Length
To set the fixed length
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Page 31
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
27
Fix Length (2 Sets Available)
1. 1st Set Begin
2. Decimal Value (See Appendix A)
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin
2. Decimal Value (See Appendix A)
3. Complete
6.5 Interleave 25 Parameters
A Check Digit Transmission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Page 32
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
28
Calculate Check Digit & Not Transmit
B Set Up Number of Character
<Even>
Odd
C Brazilian Banking Code
<Disable>
Enable
D Set 8p Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1.1st Set Beg
2. Decimal Value (See Appendix A)
Page 33
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
29
3. 1st Set Complete
1.2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin
2. Decimal Value (See Appendix A)
3. Compete
6.6 IndustriaI 25 Parameters
A Reading type
IATA25 Enable
<Disable>
B Check Digit Transmission
<Do Not Calculate Check Digit>
Page 34
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
30
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
C Set Up Code Length
To set the fixed length
1. Scan the “Begin“ label of the desired set.
2. Go the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin
2. Decimal Value (See Appendix A)
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Page 35
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
31
Minimum Length
1. Begin
2. Decimal Value (See Appendix A)
3. Complete
6.7 Matrix 25 Parameters
A Check Digit Transmission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
B Set Up Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Page 36
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
32
Fix Length (2 Sets Available)
1. 1st Set Begin
2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin
2. Decimal Value (Appendix A)
3. Complete
6.8 CODABAR/NW7 Parameters A Set Up Start/Stop Characters Upon Transmission
ON
Page 37
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
33
<OFF>
B Transmission Type of Start/Stop
<A/B/C/D> <Start>
<A/B/C/D> <Stop>
A Start
A Stop
B Start
B Stop
C Start
C Stop
D Start
Page 38
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
34
D Stop
C Set Up Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1st Set Begin Decimal Value (Appendix A)
1st Set Complete
2nd Set Begin
Decimal Value (Appendix A)
2nd Set Complete
Page 39
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
35
Minimum Length
Begin Decimal Value (Appendix A)
Complete
6.9 Code 93 Parameters A Check Digit Transmission
<Calculate Check 2 Digits & Not Transmit>
Do Not Calculate Check Digit
B Set Up Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1st Set Begin Decimal Value (Appendix A)
Page 40
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
36
1st Set Complete
2nd Set Begin Decimal Value (Appendix A)
2nd Set Complete
Minimum Length
Begin Decimal Value (Appendix A)
Complete
6.10 Code 11 Parameters A Check Digit Transmission
<Do Not Calculate Check Digit>
Calculate Check 1 Digit & Transmit
Calculate Check 2 Digits & Not Transmit
Page 41
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
37
Calculate Check 2 Digits & Transmit
Calculate Check 2 Digits & Not Transmit
B Set Up Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1st Set Begin Decimal Value (Appendix A)
1st Set Complete
2nd Set Begin Decimal Value (Appendix A)
2nd Set Complete
Page 42
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
38
Minimum Length
Begin Decimal Value (Appendix A)
Complete
6.11 MSI/PLESSEY Code Parameters A Check Digit Transmission
Do Not Calculate Check Digit
Calculate Check Digit & Transmit
<Calculate Check Digit & Not Transmit>
B Set Up Code Length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Page 43
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
39
Fix Length (2 Sets Available)
1st Set Begin Decimal Value (Appendix A)
1st Set Complete
2nd Set Begin Decimal Value (Appendix A)
2nd Set Complete
Minimum Length
Begin Decimal Value (Appendix A)
Complete
6.12 LCD25 Parameters A Check Digit Transmission
<Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Page 44
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
40
Calculate Check Digit & Not Transmit
B Setup Code length
To set the fixed length:
1. Scan the “Begin“ label of the desired set.
2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read.
3. Scan the “Complete“ label of the desired set.
4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1st Set Begin Decimal Value (Appendix A)
1st Set Complete
2st Set Begin Decimal Value (Appendix A)
2nt Set Complete
Minimum Length
Begin Decimal Value (Appendix A)
Page 45
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
41
Complete
Fix Length (2 Sets Available)
1st Set Begin Decimal Value (Appendix A)
1st Set Complete
2nd Set Begin Decimal Value (Appendix A)
2nd Set Complete
Minimum Length
Begin Decimal Value (Appendix A)
Complete
Page 46
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
42
6.15 GS1 Databar A GS1 DataBar Omnidirectionl
<Transmit Check Digit>
Dont Transmit Check Digit <Transmit Application ID>
Dont Transmit Application ID Transmit Symbology ID
<Dont Transmit Symbology ID>
B GS1 DataBar Limited Parameters
<Transmit Check Digit>
Don’t Transmit Check Digit
Page 47
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
43
<Transmit Application ID>
Don‘t Transmit Application ID
Transmit Symbology ID
<Don‘t Transmit Symbology ID>
C GS1 DataBar Expanded Parameters
Transmit Symbology ID
<Don‘t Transmit Symbology ID>
Page 48
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
44
Chapter 7 Miscellaneous Parameters
7.1 Language Selection
<US English>
UK English
Italian
Spanish
French
German
Swedish
Switzerland
Hungarian
Japanese
Page 49
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
45
Belgium
Portuguese
Denmark
Netherlands
Turkey
Reserved2
7.2 Bar Code ID
ON
<OFF>
Default
With this function ON, a leading character will be added to the output string while
Page 50
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
46
scanning code, user may refer to the following table to know what kind of bar code is being scanned.
Please refer to the table below for matching code ID of codes read in.
Code Type
ID
Code Type
ID
UPC-A
A
UPC-E
E
EAN-8
FF
EAN-13
F
CODE 39
M
CODE 128
K
Interleave 25
I
Industrial 25
H
Matrix 25
I
Codabar/NW7
N
CODE 93
L
CODE 11
L
China Postage
C
MSI
O
LCD25
Q
PLESSEY
P
GS1 DataBar Omnidirectional
U
GS1 DataBar Expanded
W
GS1 DataBar Limited
V
User Define Code ID
To set the code ID:
1. Scan the symbologies label.
2. Go to the ASCII Tables in Appendix B, scan label that represents the desired code ID. Note: User define code ID will override default value. Program will not check the conflict. It is possible to have more than two symbologies which have same code ID.
UPC-A
UPC-E
EAN-13/JAN-13
Page 51
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
47
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
Page 52
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
48
LCD25
GS1 DataBar Omnidirectional ON
GS1 DataBar Limited ON
GS1 DataBar Expanded ON
Reserved5
Reserved6
7.3 Reading Level
Bar Equals High
<Bar Equals Low>
7.4 Accuracy
1 Time
2 Times
Page 53
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
49
3 Times
4 Times
7.5 Buzzer Beep Tone
<High>
Medium
Low
Off
7.6 Sensitivity of Continuous Reading Mode
A Quick Setting:
<Fast> Slow
B Same Code Delay Reading Interval
Following code sequences represent the length of time before a barcode can be rescanned at continuous and flash reading mode. The value can be defined from 1-50 and they represent 100ms to 5 seconds in 100ms interval. Default value is 3 (0.3 seconds).
Page 54
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
50
To setup same code delay reading interval:
1.Scan the "Begin" label
2.Go the Decimal Value Tables in Appendix A, Scan label(s),that represents the same code delay reading interval. They are ranged form 1-50.One step is represented
0.1second.So the interval is from 0.1 to 5 seconds.
3.Scan the "Complete" label
4. Repeat the steps 1-3 to set time out of same symbol
Begin Decimal Value (1-50) (Appendix A)
Complete
7.7 Reverse Output Characters
<Disable> Enable
7.8 Setup Deletion
To setup the deletion of output characters:
1. Scan the label of the desired set below.
2. Scan the label of the desired symbology.
3. Go to the Decimal Value Tables listed in Appendix A, scan labels that represents the desired position to be deleted.
4. Scan "Complete" label of "Character Position to be Deleted".
5. Go to the Decimal Value Tables in appendix A,scan labels that represents the desired position to be deleted.
6. Scan the "Complete" label of "Number Position to be Deleted".
7. Repeat the steps 1 – 6 to set additional deletion.
Page 55
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
51
A. Select Deletion Set Number
1st Set
2nd Set
3rd Set
4th Set
5th Set
6th Set
B SymboIogy Selection
UPC-A
UPC-E
EAN-13/JAN-13/ISBN-13
Page 56
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
52
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/N97
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
Page 57
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
53
LCD25
GS1 DataBar Omnidirectional
GS1 DataBar Limited
GS1 DataBar Expanded
All Codes
None
C Character Position to be Deleted
1. Decimal Value (Appendix A)
2. Complete
D Number of Characters to be Deleted
1. Decimal Value (Appendix A)
2. Complete
Page 58
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
54
7.9 Setup Insertion
To setup the insertion of output characters
1. Scan the label of the desired set.
2. Scan the label of the desired symbology.
3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be inserted.
4. Scan the “Complete“ label of “Character Position to be Inserted“.
5. Go to the ASCII Tables in Appendix B or Function Key Tables in Appendix C, scan label(s) that represents the desired characters to be inserted.
6. Scan the “Complete“ label of “Characters to be Inserted“.
7. Repeat the steps 1 - 6 to set additional insertion.
A Select Insertion Set Number
1st Set
2nd Set
3rd Set
4th Set
5th Set
6th Set
Page 59
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
55
B SymboIogies Selection
UPC-A
UPC-E
EAN-13/JAN-13/ISBN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
Page 60
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
56
CODE 11
China Postage
MSI/PLESSEY
LCD255
GS1 DataBar Omnidirectional
GS1 DataBar Limited
GS1 DataBar Expanded
All Codes
None
C Character Position to be Inserted
Decimal Value (Appendix A)
Complete
Page 61
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
57
D Characters to be Inserted
ASCII Table (Appendix B)
Complete
Page 62
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
58
Appendix A Decimal Value Table
0 5
1 6
2 7
3 8
4 9
Appendix B ASCII Table
NULL
STX
SOH
ETX
ENQ
EOT
ACK
BS
BEL
HT VT LF
FF SO CR
SI
DC1
DLE
Page 63
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
59
DC2
DC4
DC3
NAK
ETB
SYN
CAN
SUB
EM
ESC
GS FS
RS US
SPACE
!
# % $
& ( ‘
) + *
, . -
/ 1 0
2 4 3
5 7 6
8 : 9
; = <
> ?
Page 64
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
60
@ B A
C E D
F H G
I K J
L N M
O Q P
R T S
U W V
X Z Y
[ ] \
^ _
` b a c e d
f h g
i k j
Page 65
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
61
l n M
o q p
r t s
u w v
x z y
} |
~ DEL
Page 66
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
62
Appendix C Function Key Table
F1 F3 F2
F4 F6 F5
F7 F9 F8
F10
F12
F11
Insert
Home
Delete
Page Up
End
Page Down
Left
Up
Right
Down
Page 67
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
63
8 SPECIFICATION
8.1 Dimensions
Page 68
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
64
8.2 Technical Data
Interface
USB
Supply Voltage
DC +5V ± 10%
Output Voltage (Typ.)
+5V
Output low Voltage (Max.)
0.4V
Current Draw (Typ.)
± 5%
Power On (Typ.)
120mA
Stand by (Typ.)
20mA
Operation (Typ.)
120mA
Light Source
Visible Red light 635nm LED
Sensor
Linear CCD Sensor
Processor Type
ARM Cortex™-M3, 32-bit
Operating Freq.
8 MHz (Internal)
Scan Speed
200 scans/ second ±10%
Depth of Field
Up to 75mm @ 20mil, PCS90%, Code39
Width of Field (Window)
80 mm
Print Contrast Ratio
45%
Resolution
3mil (0.076mm) @ PCS90%
Ambient Light
20,000 Lux Max
Reading Angle
Test Conditions : Code 39, 10mil/0.25mm, PCS 90%
Forward & Backward
±10°~30° (±5°)
Left & Right
± 60° (±5°)
Firmware
Available for updated
Driver
Support USB emulation COM port
ESD
8kv contact, 12kv on air
Bit error rate
50/100,000
Operating Temperature
0 oC to 50 oC (32 oF to 122 oF)
Storage Temperature
-20 oC to 70 oC (-4 oF to 158 oF)
Relative Humidity
20% to 95% (Non-condensing)
Page 69
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
65
8.3. Readable Symbology
Readable
Default Enable
All UPC/EAN/JAN
V
V
EAN128 Code V V
Code 39 V V
Code 39 Full ASCII
V
Code32 / Italian Pharmacy
V
Code 128 V V
CODABAR/NW7
V
V
Interleave 25 V V
Industrial 25 V
Matrix 25 V
MSI/PLESSEY V
Code 93 V
Code 11 V
China Postage V
LCD25
V
GS1 DataBar Omnidirectional
V
GS1 DataBar Turncated
V
GS1 DataBar Stacked
V
GS1 DataBar Omnidirectional Stacked
V
GS1 DataBar Limited
V
GS1 DataBar Expanded
V
GS1 DataBar Expanded Stacked
V
Page 70
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
66
8.4. Reliability
Life Time
Trigger Switch
1,000,000 times
MTBF(Calculated)
50,000 hours
Thermal Shock
High Temp.
60 oC (140 oF)
Low Temp.
-20 oC (-4 oF)
Cycle time
20 minutes for high temp. , 20 minutes for low temp.
Cycles
5 cycles
Cable Bending Test
25,000 times/ minimum (30 times/ min @ 500g/ 90 o)
Drop
59.06 inches (150cm) drop on Concrete Surface
Beeper
90 db/ minimum
Loading...