Unitary products group P1XU / G9D UPFLOW, P1XD / G9D DOWNFLOW/HORIZONTAL Installation Instruction

HIGH ALTITUDE APPLICA TION
INSTALLATION INSTRUCTION
CONVERSION INSTRUCTION
HIGH EFFICIENCY
DELUXE TWO STAGE FURNACES
035-14460-000
MODELS: P1XU / G9D UPFLOW
P1XD / G9D DOWNFLOW/HORIZONTAL
WARNING: Th is conversion kit is to be installed b y a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the autho rity having jurisdiction. If the information in these instructio ns is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete u ntil the operation o f the conver ted appliance is checked as specified in the manufacturer’s instructions supp lied with the kit.
WARNING: The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction. Installation must be made in accordance with American National Standard National Fuel Gas Code, ANSI Z223.1-latest edition, unless superseded by local codes. For Canadian installations, the conversion shall be carried ou t in accordan ce with the r equirem ents of the Provin cial author ities having jurisdiction and in accord ance with the CAN1-B149.1 and .2 installation codes.
The manufacturer accepts no responsibility for malfunctions due to improper conversi ons.
GENERAL
This instru ction is intend ed for the conv ersion of new eq uip­ment only, for operation at altitudes greater than 2,000 ft. above sea lev el. Follow th e basic unit in stallation instruction for all other aspects of the installation.
All unit installations above 2,000 ft. must be field derated as required by the National Fuel Gas Code, ANSI Z223.1 (latest edition), or in Canada , CAN /CGA B149.1 or .2 a nd all o ther applicable local codes and util ity requirements.
This instruc tion pr ovides th e neces sary infor mation to s elect and install both the proper pressure switch and orifice for your specific application. Data is provided for both natural and propane (LP ) gases. This high alti tude pressure switc h and accessory includes a special switch and other items as de­tailed below.
WARNING: Improper installati on, adjustment serv­ice, or maintenance can cause injury or property damage; therefore, only a qualified in staller or quali­fied servi ce personnel should perform this conv er­sion.
COMMON P ARTS
Description Part Number Quantity
Conversion Label 035 - 1 1635 - 000 1
Install. Instruction. 035 - 14460 - 000 1
PRESSURE SWITCH
Accessory Kit Switch Part Number Pressure Setting
1PS0315 024-27680 .25 / .75 IWG 1PS0316 024-27681 .30 / .75 IWG 1PS0317 024-27682 .25 / .50 IWG 1PS0318 024-27683 .35 / .80 IWG
PRESSURE SWITCH
All units require a pressure switch change to provide safe and reliable o peration at altitudes o ver 2,000 ft. Table 1 in dicates the correct pressure switch accessory for each unit model applied at two different altitude groupings.
WARNING: Do not adjust the original pressure switch to allow operation at high altitude. Unsafe operation will result.
TABLE 1
Upflow/Downflow Models
The high altitude pressure switch should be changed by follow­ing this procedure.
- HIGH AL TITUDE PRESSURE SWITCH U SAGE
Input
(MBH)
60 / 39 55 / 36 1PS0315 1PS0315
80 / 52 74 / 48 1PS0316 1PS0316 100 / 65 93 / 60 1PS0317 1PS0317 120 / 78 112 / 72 1PS0318 1PS0318
CAUTION: The gas supply shall be shut off prior to disconnectin g the electri cal power , b efore procee ding with the conversio n.
1. Remove the burner access door.
2. Note the locati on of the wir es on th e right h and pr essur e control and then di scon nect them . Remo ve the h ose f rom the pressure control.
Output (MBH)
2,000 Ft
to 10,000 Ft.
> 2,000
To 10,000 Ft.
650.78-N2.1V
3. Remove the screws securing the pressure control and remove it from the unit. Check that the new pressure control part number is correct for your application (refer to Table 1). Install the new pressure control.
4. Replace the hose and wiring as originally connected.
ORIFICE SIZE SELECTION
A numb er of factors determi ne the correct orifice us age for your application. These factors include the original orifice sizing, BTU content of the gas and the altitude.
The standard o rifice us ed in the furna ce is shown in Table 2. Find your unit and determine the standard orifice provided.
For natural gas applications, contact your gas supplier for the actual BTU content (heating value) of the fuel provided at your altitude. Table 3 indicates various BTU content fuels.
Use the BTU heat ing v alue that is ne arest to your valu e. Read across the selected table from the standard orifice to the altitude for your application and the note the new orifice num­ber.
EXAMPLE: If your unit ha s a #45 orifice as stan dard and a heating gas value of 900 BTU/CU.FT., at an altitude of 7, 000 feet a #47 orif ice will provide the c orrect firing rate.
For propane (LP) gas applications, Use Table 4 to select the proper high altitude orifice s ize.
WARNING: The fu rnace must first b e converted to use propane (LP) gas throug h the use of the stand ard propane conversion kit accessory.
TABLE 2
Upflow-Downflow/Horizontal Models
- STANDARD ORIFICE USAGE
Input
(MBH)
60 / 39 55 / 36 # 45 # 55
80 / 52 75 / 48 # 45 # 55 100 / 65 95 / 60 # 45 # 55 120 / 78 112 / 72 # 45 # 55
Output (MBH)
Natural
Orifice Size
Propane
Orifice Size
After selecting the proper orifice size for your application, see the listing o n Table 5 that in dicates the par t number for your required orifice number. The orifices may be obtained through your local Source 1 Parts Distribution Center.
The high altitude orifices should be changed by the following procedure:
1. Carefull y remove the wi res from the gas valve and n ote their location so they may be properly replaced. Remove the burner box door. Remove the two screws that hold the manifold to the burner box and slide the manifold and orifices back out of the burners.
2. Remove the main burner orifices from the manifold and discard them
3. Install the derate main burner ori fices in the manifold and tighten them. Aft er installing a new orific e in each locat ion, any leftover orifi ce s ma y be dis ca rde d.
TABLE 3
(Manifold Pressure
TABLE 4
(Manifold Pressure
- ALTITUDE/NATURAL GAS HEATING VALUE ORIFICE SECTION
Natural Gas
Heating V al ue
3.5" W.C.) 1200
BTU/CU.FT.
1 100
BTU/CU.FT.
1000
BTU/CU.FT.
900
BTU/CU.FT.
800
BTU/CU.FT.
- ALTITUDE/PROPANE (LP) GAS HEATING VALUE ORIFICE SECTION
Propane Gas
Heating V al ue
10.0" W.C.)
2516
BTU/CU.FT.
Orifice
Shipped
With Unit
45 48 49 49 50 50 50 51 51 52 52 43 45 46 47 47 47 48 48 49 49 49 45 47 48 48 49 49 49 50 50 51 51 43 44 45 45 45 46 47 47 48 48 49 45 45 46 47 47 47 48 48 49 49 50 43 43 44 44 44 45 45 46 47 47 48 45 44 45 45 45 46 47 47 48 48 49 43 42 42 43 43 43 44 44 45 46 47 45 43 44 44 44 45 45 46 47 47 48 43 39 40 41 41 42 42 43 43 44 44
Propane
Orifice @
Sea Level
54 54 54 55 55 55 55 55 56 56 56 55 55 55 55 55 56 56 56 56 56 57 56 56 56 56 57 57 57 58 59 59 60
0 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
0 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
Recommended Orifice
Altitude (Ft. Above Sea Level)
Recommended Orifice
Altitude (Ft. Above Sea Level)
2 Unitary Products Group