UNI-T UT39A, UT39C, UT39B Operating Manual

TABLE OF CONTENTS TITLE PAGE
Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement Operation A. DC Voltage Measurement B. AC Voltage Measurement C. DC Current Measurement D. AC Current Measurement E. Measuring Resistance F. Frequency Measurement (The Model UT39C only) G. T emperature Measurement (The Model UT39C only) H. Capacitance Measurement I. Measuring Diodes & Continuity J. Measuring Transistor Sleep Mode General Specifications Accuracy Specifications A. DC Voltage B. AC Voltage C. DC Current D. AC Current E. Resistance Test F. Frequency (The Model UT39C only) G. Temperature (The Model UT39C only) H. Capacitance
1
3 3 4 5 7 7 8 8 9 9 10 11 13 14 15 16 17 18 19 20 20 21 21 21 22 22 23 23 23 24
Model UT39A/B/C: OPERATING MANUAL
24 24 25 25 25 26
PAGE
I. Diodes and Continuity Test J. Transistor Test Maintenance A. General Service B. Replacing the Battery C. Replacing the Fuses
Model UT39A/B/C: OPERATING MANUAL
2
3
Overview
Warning To avoid electric shock or personal injury, read the “Safety Information” and “Rules for Safety Operation” carefully before using the Meter.
Digital Multimeters Model UT39A, UT39B and UT39C (hereafter referred to as “the Meter”) are 3 1/2 digits with steady operations, fashionable structure and highly reliable hand-held measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. The Meter not only can measure AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Temperature, Transistor, Frequency, Diodes and Continuity, but also has Data Hold and Sleep Mode features.
The Meter comes with a holster which can provide sufficient and anti-shaking.
Unpacking Inspection
Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part:
Item Description Qty
English Operating Manual Test Lead Point Contact Temperature Probe (UT39C only) Holster 9V Battery (NEDA 1604 or 6F22 or 006P)
1 2 3
4 5
1 piece 1 pair 1 piece
1 piece 1 piece
In the event you find any missing or damage, please contact your dealer immediately.
Model UT39A/B/C: OPERATING MANUAL
Safety Information
This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. I 1000V, CAT. II 600V) and double insulation.
CAT. I: Signal level, special equipment or parts of equipment, telecommunication, electronic, etc., with smaller transient overvoltages than overvoltages CAT. II.
CA T. II: Local level, appliance, PORT ABLE EQUIPMENT etc., with smaller transient voltage overvoltages than CAT. III
Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test.
A Note identifies the information that user should pay attention on.
International electrical symbols used on the Meter and in this Operating Manual are explained on page 7.
4
Model UT39A/B/C: OPERATING MANUAL
Rules For Safe Operation
Warning To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules:
l
l
l
l
l
l l
l l
Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity . Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter. When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock. Use the proper terminals, function, and range for your measurements. Do not use or store the Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened. When using the test leads, keep your fingers behind the finger guards. Disconnect circuit power and discharge all high­voltage capacitors before testing resistance,
5
Model UT39A/B/C: OPERATING MANUAL
l
l
l
l
l
l
l l
l
continuity, diodes, capacitance or current. Before measuring current, check the Meter’s fuses and turn off power to the circuit before connecting the Meter to the circuit. Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury. Remove test leads and temperature probe from the Meter and turn the Meter power off before opening the Meter case. When servicing the Meter, use only the same model number or identical electrical specifications replacement parts. The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter and any accident. Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. The Meter is suitable for indoor use. Turn the Meter power off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter.
6
Model UT39A/B/C: OPERATING MANUAL
Deficiency of Built-In Battery AC (Alternating Current) AC or DC Double Insulated Warning. Refer to the Operating Manual Conforms to Standards of European Union Grounding DC (Direct Current) Diode Continuity Test Fuse
International Electrical Symbols
The Meter Structure (see figure 1)
1. LCD Display
2. Data Hold Button
3. Transistor Jack
4. COM Input Terminal
5. Other Input Terminals
6. mA Input Terminal
7. 20A/10A Input Terminal
8. Capacitance Jack
9. Rotary Switch
10. Power
( figure 1)
7
Model UT39A/B/C: OPERATING MANUAL
Button POWER
(Y ellow Button)
HOLD
(Blue Button)
Operation Performed
Turn the Meter on and off. Press down the POWER to turn on the Meter. Press up the POWER to turn off the Meter. Press HOLD once to enter hold mode. Press HOLD again to exit hold mode. In Hold mode, is displayed and the present value is shown.
Functional Buttons
Below table indicated for information about the functional button operations
l l l l l
Display Symbols (see figure 2)
( figure 2)
Symbol
hFE
0
C
No.
1 2 3
4 5 6 7 8
Meaning
Data hold is active. Indicates negative reading. The battery is low.
Warning: To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator appears.
Unit of Transistor Centigrade temperature Test of diode. The continuity buzzer is on. Dangerous Voltages.
8 7 6
5
4
1
2 3
8
Model UT39A/B/C: OPERATING MANUAL
9
Make sure the Sleep Mode is not on if you found there is no display on the LCD after turning on the Meter. Make sure the Low Battery Display is not on, otherwise false readings may be provided. Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measeurement.
l l l
A. DC Voltage Measurement (see figure 3)
Warning T o avoid harms to you or damages to the Meter from electric shock, please do not attempt to measure voltages higher than 1000V or 750V rms although readings may be obtained.
Take extra attention when measuring high voltages to avoid electric shock.
To measure DC voltage, connect the Meter as follows:
1. Insert the red test lead into the V input terminal and the black test lead into the COM input terminal.
2. Set the rotary switch to an appropriate measurement position in V range.
3. Connect the test leads across with the object being measured. The measured value shows on the display.
( figure 3)
Black Red
Model UT39A/B/C: OPERATING MANUAL
Measurement Operation
Loading...