UNISONIC TECHNOLOGIES CO UR132 Technical data

UTC UR132 LINEAR INTEGRATED CIRCUIT
200mA LOW DROPOUT LINEAR VOLTAGE REGULATOR
DESCRIPTION
The UTC UR132 is a 200mA fixed output voltage low dropout linear regulator. Wide range of available output voltage fits most of applications. Built-in output current-limiting most thermal-limiting provide maximal protection against any fault conditions.
FEATURES
*Guaranteed 200mA output current *Input voltage range up to 12V *Extremely tight load regulation *Fast transient response *Current-limiting and Thermal-limiting *Three-terminal adjustable or fixed voltage.
APPLICATIONS
*Voltage regulator for LAN Card, CD-ROM, and DVD *Wireless communication systems
PIN DESCRIPTION
NAME FUNCTION VOUT Output
GND Ground/Adjustable
VIN Positive Power Input
Function Block Diagram
SOT-23 : 1: V SOT-25 : 1: V
2
1
3
SOT-23
1
2
3
5
4
SOT-25
2: GND 3: V
OUT
GND 3: NC 4: NC 5: V
IN 2:
IN
OUT
UTC UNISONIC TECHNOLOGIES CO., LTD. 1
QW-R102-007,E
UTC UR132 LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS
Input Voltage Vin -0.3 12 V Operating Junction Temperature Range -40 125 Storage Temperature Range -65 150 Power Dissipation 0.3 W
UTC UR132- Vo<3.3V (Vo±2%) ELECTRICAL CHARACTERISTICS
Output Voltage IL=2mA, VIN-VOUT=2V Output Voltage Temperature
Coefficient Line Regulation IL=2mA, VIN-Vout=2V~Vin=9V 0.5 %VOUT Load Regulation (note 2) IL=2mA~200mA, VIN-Vout =2V 10 30 mV Current Limit (note 3) VIN-Vout=2V, VOUT=0V 300 mA Dropout Voltage (note 4,5) 1.5 V
Standby current IL=0, VIN=9V 3.0 mA
UTC UR132- ADJ / Vo3.3V (Vo±2%) ELECTRICAL CHARACTERISTICS
Output Voltage IL=2mA, VIN-VOUT=2V Adjustable (R1=120Ω,R2=200Ω,Vout=3.3V)
Reference Voltage Vin-Vo=2V, IL=2mA 1.238 1.250 1.262 V Output Voltage Temperature Coefficient Line Regulation IL=2mA, VIN-Vout=2V~Vin=12V 0.5 %VOUT Load Regulation (note 2) I Current Limit (note 3) VIN-Vout=2V, VOUT=0V 300 mA Dropout Voltage (note 4,5) 1.3 V Standby current IL=0, VIN=12V 5.0 mA
Note 1: Guaranteed by design. Note 2: Regulation is measured at constant junction temperature, using pulsed ON time. Note 3: Current Limit is measured at constant junction temperature, using pulsed ON time. Note 4: Dropout is measured at constant junction temperature, using pulsed ON time, and the criterion is V
inside target value±2%.
Note 5: Dropout test is skipped at the condition of V
PARAMETER MIN. TYP. MAX. UNIT
°C °C
(Ta=25°C, CIN=1µF, COUT=10µF, unless otherwise specified)
PARAMETER TEST CONDITIONS MIN TYP. MAX UNITS
50 150
(Ta=25°C, CIN=1µF, COUT=10µF, unless otherwise specified)
PARAMETER TEST CONDITIONS MIN TYP. MAX UNITS
50 150
=2mA~200mA, VIN-Vout =2V 10 30 mV
L
IN<3V.
Vo×0.98
Vo×0.98
Vo
Vo
Vo×1.02
Vo×1.02
V
PPM/°C
V
PPM/°C
OUT
UTC UNISONIC TECHNOLOGIES CO., LTD. 2
QW-R102-007,E
Loading...