Unison ERn2-RM-120, ERn2-RM-230CE, ERn2-RM-240, ERn4-RM-240, ERn4-RM-120 Installation Manual

...
Part Number: 7180M2110 Rev: C
Released: 2016-11
Unison
®
ERn Rack Mount Enclosure
Installation Manual
ETC® and Unison® are either registered trademarks or trademarks of Electronic Theatre Controls, Inc. in the United States and other countries.
Echelon®, LON®, LONW
ORKS
®
are registered trademarks of Echelon Corporation in the United States
and other countries.
All other trademarks, both marked and not marked, are the property of their respective owners.
ETC intends this document, whether printed or electronic, to be provided in its entirety.This product is intended for professional use only. Read this entire document before using this product.
Table of Contents i
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
ERn Modules and Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Warnings and Notice Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Contacting ETC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Prepare for Installation . . . . . . . . . . . . . . . . . . . . 5
Preparations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Unpack and Inspect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Main Circuit Breaker Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Lockout/Tagout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Maximum Current Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Rack Mounting Specifications . . . . . . . . . . . . . . . . . . . . . . . . .6
Dimensions and Weights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Installation Environment Requirements . . . . . . . . . . . . . . . . . . . . . . . .6
Wire Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Wire Routing and Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Control Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Data Types and Topologies . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Install Enclosure . . . . . . . . . . . . . . . . . . . . . . . . .10
Install in a 19” Equipment Rack . . . . . . . . . . . . . . . . . . . . . . .10
Connect Wiring . . . . . . . . . . . . . . . . . . . . . . . . . 11
IEC Power Input Connector. . . . . . . . . . . . . . . . . . . . . . . . . . .11
ERn Rack Mount Enclosure Power Input. . . . . . . . . . . . . . . . .11
Connect Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Connect Rear Panel I/O Data Terminations . . . . . . . . . . . . . . . . . . . . .12
Terminate DMX Control Wiring . . . . . . . . . . . . . . . . . . . . . . .12
Terminate LinkConnect Control Wiring . . . . . . . . . . . . . . . . .13
Terminate Auxiliary Power . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Connect to Serial RS-232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Connect to Ethernet RJ-45 . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Connect to Contact Inputs and Contact Outputs . . . . . . . . . .16
Right I/O Board Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Terminate DMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Install Rack Options . . . . . . . . . . . . . . . . . . . . . . 19
Rack Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Install the Ride Thru Option (URTO) Kit. . . . . . . . . . . . . . . . . . . . . . . .19
Connect Ride Thru Option Wiring . . . . . . . . . . . . . . . . . . . . . .20
ii Unison® ERn Rack Mount Enclosure Installation Manual
Install a Paradigm Repeater or Dual Repeater Module . . . . . . . . . . .21
Terminate LinkConnect Control Wiring . . . . . . . . . . . . . . . . .22
Terminate Auxiliary Power . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Install Redundant Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Status Indicator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Final Installation and Power Up . . . . . . . . . . . .25
Completing the Installation . . . . . . . . . . . . . . . . . . . . . . . . . .25
Check Main Power Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Putting the Rack Back Together . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Aux Power and LinkPower Status Indicators . . . . . . . . . . . . . . . . . . . .26
Final Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Introduction 1
Introduction
Welcome to the installation manual for the Unison® ERn rack mount external processing enclosure. This manual contains the procedures for safe and efficient installation of ERn series processing racks, including wire termination and option kit installation.
The ERn enclosure is available in two sizes, ERn2 and ERn4, which can be supplied for surface mounting on a wall (reference the
Unison ERn Wall Mount Enclosure Installation Manual
) or with rack mounting brackets for installation in a standard 19” equipment rack. The ERn is available in three voltage options, 120, 230, and 240 VAC to meet your installation requirements.
The ERn provides Unison architectural control to distributed Unison, Sensor3, or other DMX512 dimming systems. Used stand alone or in multi-processor network systems, the ERn series enclosure offers elegant low-profile rack mounting, integrated back-lit control electronics, and the ultimate in architectural lighting control versatility.
The ERn2 enclosure provides two module slots, one slot for the Paradigm architectural control processor (P-ACP) and one for use of the Paradigm station power module (P-SPM) or a blank (air flow) module (ERn-BM). The accessory tray in the bottom of the enclosure can be used for either an optional redundant rack power supply (ERn-RPS) or blank option module.
The ERn4 enclosure provides four module slots, two slots which can be used for Paradigm architectural control processor’s (P-ACP) and an additional two slots for use of option modules such as the Paradigm station power module (P-SPM) or a Paradigm repeater module (P-REP). Alternatively, the top two slots in the enclosure may be used for a dual paradigm repeater module (P-DREP).The accessory tray in the bottom of the enclosure can be used for either an optional redundant rack power supply (ERn-RPS) or the blank option module.
Model Voltage / Frequency Notes
Rack Mount
ERn2-RM-120 85-120 VAC, 47-63 Hz (single phase) External processing rack configured for
19” rack mounting utilizing 5 rack units (or 5U) of rack space. Use with one Paradigm architectural control processor (ACP) and one option module.
ERn2-RM-230CE 180-265 VAC, 47-63Hz (single phase)
ERn2-RM-240 180-265 VAC, 47-63 Hz (single phase)
ERn4-RM-120 85-120 VAC, 47-63 Hz (single phase) External processing rack configured for
19” rack mounting utilizing 8 rack units (or 8U) of rack space. Use with up to two Paradigm architectural control processors (ACP) and up to two option modules.
ERn4-RM-230CE 180-265 VAC, 47-63Hz (single phase)
ERn4-RM-240 180-265 VAC, 47-63 Hz (single phase)
ERn2-RM
ERn4-RM
2 Unison® ERn Rack Mount Enclosure Installation Manual
ERn Modules and Options
Model
Part
Number
Description Notes
P ACP 7180A1001
Paradigm Architectural Control Processor
The Paradigm ACP provides powerful and flexible control for architectural and theatrical applications with straightforward integrated networking for both NetConnect and LinkConnect networks.
• Tool-free installation into the ERn enclosure. Up to two Paradigm ACPs may be installed in the ERn4 enclosure.
• Features an easy to navigate user interface which is usable with the door attached.
• Supports up to 62 Unison control stations over the LonWorks network with the use of Paradigm station power and repeater modules.
• Provides two ports of one DMX universe each (512 addresses each), individually switchable between input and output.
P-SPM 7182A1001
Paradigm Station Power Module
The Paradigm SPM provides power for Unison control stations over the LinkConnect network and provides the station data bus length up to 1,640 feet (500m).
• Tool-free installation into an ERn enclosure.
• Supplies LinkConnect for up to 32 Unison control stations.
P-REP 7182A1003
Paradigm Station Repeater Module
The Paradigm REP module extends the system station bus length 1,640 feet (500m) and increases the possible station count by an additional 30 stations. For use only in an ERn4 enclosure.
• Tool-free installation into an ERn4 enclosure.
• For use in an ERn4 enclosure only.
ERn-BM 7180A1402
Airflow Option Module
The ERn BM is used to fill empty module space in the ERn series enclosure, maintaining the convection cooled design.
• Tool-free installation into an ERn enclosure.
P-ACP
P-SPM
P-REP
P-DREP
ERn-RPS
URTO
ERn-BM
Introduction 3
Warnings and Notice Conventions
These symbols are used in ETC documentation to alert you to danger or important information:
P-DREP 7182A1004
Paradigm Dual Station Repeater Module
The Paradigm DREP module extends the system station bus length 3,280 feet (1,000m) through two separate topology­free Echelon segments, each supporting 1,640 feet (500m).
• Tool-free installation into and ERn4 enclosure.
• The dual repeater module also adds support for up to 30 additional Unison architectural control stations.
• For use in an ERn4 enclosure only.
URTO 7180A1410
Unison Ride Thru Option Kit
The URTO kit provides power for one Paradigm architectural control processor in the host enclosure for a limited time (minimum of 12 seconds) during brief power outages or drop outs.
• If installed in an ERn4 enclosure, one URTO is required per Paradigm ACP.
ERn-RPS 7180A1401
ERn Redundant Power Supply
The ERn RPS provides an additional rack power supply that powers the ERn enclosure if the primary rack power supply fails.
Note:
The redundant power supply (ERn-RPS) is not supported in ERn4 enclosures at 230 VAC. Instead the ERn4 at 230 VAC is shipped from the factory with a rack power supply installed in the top (normal) position and in the lower option module slot as standard.
Note:
Notes are helpful hints and information that is supplemental to the main text.
CAUTION:
A Caution statement indicates situations where there may be undefined or unwanted consequences of an action, potential for data loss or an equipment problem.
WARNING:
A Warning statement indicates situations where damage may occur, people may be harmed, or there are serious or dangerous consequences of an action.
WARNING:
RISK OF ELECTRIC SHOCK! This warning statement indicates situations where there is a risk of death by electric shock.
4 Unison® ERn Rack Mount Enclosure Installation Manual
Contacting ETC
For questions about Unison rack system delivery, contact ETC Systems Group. For general information, your most convenient resources are the references provided in this manual. To search more widely try the ETC web site at etcconnect.com.
For technical questions about Unison rack systems, contact ETC Technical Services directly at one of the offices listed below. Emergency service is available from all ETC offices outside of normal business hours. When calling for assistance, please have the following information handy:
• Your location and job name.
• A complete list of ETC equipment.
• A complete list of other installed products and components connected to the system you are troubleshooting.
• DMX control source, if any.
Please email comments about this manual to: TechComm@etcconnect.com
Americas
ETC International Technical Services Department 3031 Pleasant View Road Middleton, WI 53562 800-775-4382 (USA, toll-free) +1-608 831-4116
service@etcconnect.com
United Kingdom
Electronic Theatre Controls, Ltd. Technical Services Department 26 - 28 Victoria Industrial Estate Victoria Road, London W3 6UU, UK +44 (0)20 8896 1000
service@etceurope.com
Asia
ETC Asia, Ltd. Technical Services Department Room 1801, 18/F, Tower 1, Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay, Kowloon, Hong Kong +852 2799 1220
service@etcasia.com
Germany
Electronic Theatre Controls, GmbH Technical Services Department Ohmstrasse 3 93607, Holzkirchen, Germany +49 (80 24) 47 00-0
techserv-hoki@etcconnect.com
Prepare for Installation 5
Prepare for Installation
Preparations
Unpack and Inspect
Before you begin installation, check your shipment and confirm it arrived complete and undamaged.
1: Check the shipping container for physical damage. 2: If you find damage, document it to help with a claim against your shipper. 3: Unpack your order and check the contents against the packing list to be sure your order is
complete.
4: If you discover a problem, call the ETC Systems Group at the closest office of purchase. See
Contacting ETC
on
page 4
.
Main Circuit Breaker Protection
Before you begin installing the Unison® ERn enclosure, make sure you have installed a main circuit breaker cabinet or other readily accessible input power disconnect device in the same room or in close proximity of the installed ERn enclosure.
Lockout/Tagout
Equipment should be locked out while being repaired. Accidents which occur because machinery that is being repaired and not locked out often result in serious injuries like amputations, fractures, and even death. Locking out and tagging power at its source is important while repairing or adjusting equipment because it ensures that power does not reach the equipment being serviced.
• To lockout means to place a lock on a device that prevents the release of energy. Locking out is intended to prevent the unexpected startup or energizing of machinery and equipment during service and maintenance operations.
• To tagout means to place a tag on a switch or other shut off device which warns others not to start the piece of equipment. Tagout should only be used with lockout, unless locking out the equipment is impossible.
General Lockout/Tagout Procedures:
• Notify all affected employees that a lockout/tagout procedure is ready to begin.
• Turn off the equipment at the control panel.
• Turn off or pull the main disconnect. Be sure all stored energy is released or restrained.
• Check all locks and tags for defects.
• Attach your safety lock or tag on the energy isolating device.
• Try to restart the equipment at the control panel to ensure that it is secured.
• Check the machine for possible residual pressures, particularly for hydraulic systems.
• Complete the repair or servicing work.
• Remove the safety lock and adapter.
• Let others know that the equipment is back in service.
WARNING:
Enclosures installed without an accessible power disconnect device cannot be serviced or operated safely. Follow all local codes and restrictions.
When the disconnect device is not located near the installed enclosure, the disconnect must allow for proper lockout / tagout.
6 Unison® ERn Rack Mount Enclosure Installation Manual
Maximum Current Input
The ERn enclosure draws a maximum current of 3 amps when fully populated.
Rack Mounting Specifications
An ERn configured for installation in a 19” equipment rack requires 5U of rack space for an ERn2 and 8U of rack space for an ERn4. ERn enclosures are provided with rack mounting brackets attached to the ERn enclosure at shipment. The locking door attaches to the equipment rack for a secure installation.
Dimensions and Weights
Installation Environment Requirements
• For your safety, you should install a circuit breaker cabinet or other readily accessible input power disconnect device in the same area as the Unison ERn enclosure. Breakers not in the same room must have a physical means to be locked off.
• A clean (not dusty), temperature controlled environment with the following conditions:
• ambient temperature of 32-104°F / 0-40°C
• ambient humidity of 10-90%, non-condensing
• Restricted public access to prevent tampering.
• All CE equipment is tested to EMC category B environment.
Enclosure
Type
Height Width Depth
Product
Weight
Shipping
Weight
inches mm inches mm inches mm lbs kgs lbs kgs
ERn2-RM w/ rack door
8.8 223 19 483 9.6 244 16.6 7.7 20 9.1
ERn4-RM w/ rack door
14.1 358 19 483 9.6 244 23.8 11 25 11.3
CAUTION:
HVAC systems must at all times maintain the specified ambient temperature at the Unison ERn enclosure.