UniTracer
[Electronic locking device for container]
USER MANUAL
FOR UniTracer L-100(G)
This guide explains the device UniTracer L-100(G).
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
Table of Contents
1. Precautions concerning pre-service .......................................................................................................................... 3
1.1 Precautions .................................................................................................................................................................. 3
1.2 Device package configuration .......................................................................................................................... 3
1.3 Component parts of the device ...................................................................................................................... 5
1.4 Device installation and sealing method ..................................................................................................... 6
1.5 How to unseal and retrieve the device ....................................................................................................... 8
2. How to use the device ...................................................................................................................................................... 9
2.1 Device operating process .................................................................................................................................... 9
2.2 Insertion of the USIM ......................................................................................................................................... 10
2.3 Check battery remaining volume ................................................................................................................ 11
3. Device maintenance ........................................................................................................................................................ 12
3.1 Wire replacement method ............................................................................................................................... 12
3.2 USIM replacement method ............................................................................................................................. 12
3.3 How to deal with battery charging/discharging and replacement.......................................... 12
3.4 Device reset method ........................................................................................................................................... 12
3.5 APN and NFC setting method ....................................................................................................................... 13
4. Trouble Shooting ............................................................................................................................................................... 20
4.1 Device debugging method .............................................................................................................................. 20
4.3 Log data analysis method ................................................................................................................................ 33
5. Device FAQ ........................................................................................................................................................................... 35
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
1. Precautions concerning pre-service
1.1 Precautions
- The battery should be used after full charging. The device connects a 5V 2A adapter to the
USB port using the included USB cable.
- The USIM card should be prepared for local use or roaming in accordance with the purpose
of use.
- Once inserted, it is imperative that the insertion of caution is checked again, because it cannot
be withdrawn again.
- To use an NFC card, you must register the NFC card ID in the L-100 device.
- This device can be operated in at least one Member State of EU without infringing applicable
requirements on the use of radio spectrum.
1.2 Device package configuration
UniTracer L-100 Mini B type USB cable
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
- UniTracer L-100 Specification
792 Times(33 days)
(24 Collections per day, every hour)
Lithium-Ion
6,000mAh(Rechargeable)
Open/Close of door, Location,
Detect cutting
1.5Kg
(Inclusive 500g battery)
NFC transmit / receive
frequency range
GPS receive
frequency range
-
-
GSM 850 : 8 24.2 ~ 848.8 MHz
GSM 1900 : 1850.2 ~ 1909.8 MHz
GSM 850 : 869.2 ~ 893.8 MHz
GSM 1900 : 1930.2 ~ 1989.8 MHz
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
1.3 Component parts of the device
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
The left wire segment is fixed.
You can hold and open and close the right
wire segment.
Where to tag the NFC card
- Blinking green light for GPS
communication
- Blinking blue light for WCDMA/GSM
communication
Port that inserts USIM card
Port that charges the device and analyzes
the device log
Switch to reset the device
1.4 Device installation and sealing method
- With the wire open, wire the device to the container lock and fasten the device.
- When connecting the wire to the device, be sure to push it all the way to prevent the connection
failure.
- Confirm the lock by touching the NFC card registered in the NFC antenna section within
5 seconds after wire tightening.
- Attach the magnet on the back of the L-100 to the flat surface (steel material) of the container
and tighten the device to the container.
- When attaching the L-100 to a container, etc., be sure to install the L-100 in the following
direction to obtain optimal GPS reception.
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
<Figure. Device installation Position>
- GPS reception rate is the best
when the GPS antenna is pointing
in the sky.
<Figure. actual device installation example>
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
1.5 How to unseal and retrieve the device
1) The operation switch is not lit when the device is operating. At this time, when the
operation switch is pressed, the NFC antenna lights in blue. (The light is kept in blue for 5
seconds.)
2) Attach the registered NFC card before the blue light on the NFC antenna turns off. (The
blue light is on for 5 seconds.) When the touch is completed, the buzzer sounds and the
NFC antenna turns off. At this time, pull the right wire segment after press it slightly inwards.
When the wire is disconnected, a green light blinks to receive the GPS(to send the device's
open signal). When the green light is off, a blue light will come on for the data
communication. The blue light turns off when data transmission is completed.
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
3) Device retrieve method
- Hold the eSeal device with the magnet attached to the container with both hands firmly and
remove it safely.
- Retrieve the device with opened wire device.
2. How to use the device
2.1 Device operating process
1) When the wire is tightened, the NFC card authentication is performed first.
- The LED of the NFC antenna flashes together with a beep for 5 seconds.
- The registered NFC card should be touched to the NFC tag within 5 seconds.
- If the NFC card is authenticated, the alarm is stopped and the LED flashes.
※ In order to use NFC card, NFC card ID must be registered in L-100 device.
(Refer to '3.5 APN and NFC setting method’ .)
2) When the NFC card authentication is completed, GPS is received. (Takes up to 180 seconds)
- At this time, the Operation switch flashes green.
- When the GPS reception is complete, the green light turns off.
3) Once the GPS reception is complete, access the communication network. (Up to 300 seconds).
- At this time, the Operation switch flashes blue.
- When the device is connected to the network and the data transmission is finished, the
blue light turns off.
4) After the Operation switch light is blinking, the device waits until the next operation.
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
2.2 Insertion of the USIM
Open the water-proof cover and insert it into the following directions.
(Once engaged, ensure that the correct tightening is achieved and the correct orientation
is achieved.)
<Figure. Device USIM insertion direction>
< Figure. Actual device USIM insertion example>
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
2.3 Check battery remaining volume
Under the operation of the Operation switch, the battery power level notification (LED Color)
is like
the Blue light is High level, the Green light is Middle level, the Red light is Low level.
- How to check the remaining battery level is as follows.
1) You can check the remaining battery level by viewing the debugging data of the device.
e.g.) II 2017/08/18 04:56:48 BSU(0:0:1) SM(0) BAT(4350)
In the above debugging data, the BAT(4350) is the remaining battery power.
Here, the battery means 4350 is 4.35V.
※ Refer to '4.1 Device debugging method' for details.
2) You can check the remaining battery level by viewing the log of the equipment.
e.g.) 17/08/25 06:55:40, 1, 0, A, 37 24.088240 N, 127 06.467960 E, 4236, 0xD0 0x76 0x5
- Meaning: August 25
th
2017 6:55:40(Date), 1(event code), 0(open status), A(GPS reception
status), 37 24.088240 N(latitude), 127 06.467960 E(longitude), 4236(battery value), D0-76-
58-7E(NFC key value)
In the above log, the battery value is 4236 and the value is 4.236V.
※ Refer to '4.2 Log data analysis method' for details.
3) You can check the remaining battery level in the tracking monitoring system.
You can check the remaining battery level in 'Battery' item in 'Transport history' - 'Tracking
' by accessing the tracking monitoring system.
Here, the remaining battery level is displayed in %.
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
3. Device maintenance
3.1 Wire replacement method
- If the wire breaks and the wire needs to be replaced, refer to the Technical Maintenance
Document, which describes how to replace the wire.
3.2 USIM replacement method
Once inserted, it is imperative that the insertion of caution is checked again, because it
cannot be withdrawn again.
If the USIM is incorrectly inserted or the USIM is defective, refer to the Technical
Maintenance Document that describes how to replace the USIM.
3.3 How to deal with battery charging/discharging and replacement
- Battery charging can be charged by plugging the mini B USB cable underneath the device.
The charging input voltage uses 5 V 2A.
- If the battery is discharged and the wire cannot be released, connect a portable external
battery to the USB port of the device and release the wire.
- The battery is cut off at 3.21 V to enter sleep mode and will not operate the equipment.
- If the battery is completely discharged or the battery is defective, refer to the Technical
Maintenance Document for replacement of the battery.
3.4 Device reset method
- Press the Operation switch on the device and press the Reset switch when no light flickers.
(When the remaining battery power is normal)
- When upgrading the firmware of the device, press the reset switch after completing the
file transfer.
※ Refer to UniTracer L-100 Firmware upgrade manual.
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548
- Change the settings such as APN and NFC registration and press the reset switch.
3.5 APN and NFC setting method
Input the commands by the PuTTY Program.
1) The device’s wire is opened by NFC generally.
2) The device receives GPS signal and wait until transmitting ‘Open’ event.
3) After ‘Open’ event is sent, the device will be changed to ‘setting mode’.
4) The USB cable(A to Mini-B type) connects to PC.
5) After Serial COM port is recognized, COM port connects to ‘115200’ Speed.
(Checking the COM port can be found in Device Manager on your PC.)
6) After the device closes, the device is working normally again.
www.unisem.co.kr | iot@unisem.co.kr | +82.31.724.2548