Follow the procedures in this manual to operate this machine safely and effectively. Ensure that this manual is readily available to the operator at all times. If you have any questions about the operation of this machine, contact:
North America: Uni-ram Technical Service 1-800-417- 9133
Other Continents: Contact Your Supplier
FEA TURES AND SPECIFICA TIONS
The UR700QVAC is 120 V, 2000 W, 50/60 Hz and the UR700QVAC-H is 240 V, 2000 W, 50/60 Hz. These mobile vacuums are ideally suited for automotive, marine and industrial applications wherever air operated, vacuum-assist tools are used. Two technicians can work on different projects at the same time.
• Portable. A Single Cartridge Filters is standard. High Density Filters are available.
• One or two operators can work simul-
taneously, 20 foot power cord, 16 foot vacuum hose.
Electrical outlet for use with one electrical sander.
• Automatic activation of vacuum by air
tool, manual override.
• 2 motors 1,000 W each; Select single or
dual vacuum motors, single - 1,000 W and dual 2,000 W. Maximum decibel rat­ing at 2,000 W is 70 db. Wattage (power consumption) can be reduced using the Variable Power Adustment dial.
Sealed Vacuum: 99” water (2500mm)
Supply air pressure: 100 -150 PSI (6.510.0 bar)
Weight: (700) 72 lb / 33 kg
••Motor is a bypass, 2 stage motor for long life and va­cum power. Diecast housing. Internal fan for cooling. Shipping Dimensions (WDH): 41 X 23 X 24”
CAUTIONS AND WARNINGS Do not use this vacuum with hazardous dust such as alumina and magnesia dust
and do not use with fl ammable liquids like gasoline. Repair must be carried out by a qualifi ed technician.
PREVENTATIVE MAINTENANCE
Replace brushes every 450 hours. See the list of Replacement Parts.
SETUP
Check for transportation or handling damage.
Make sure the Vacuum Head is securely clamped.
The Pressure Switch is in a separate carton. Install the Pressure Switch. Connect the Short Power Cord from the Presure Switch to the Control Panel connector on the Vacuum Head. Make sure the connection is secure.
Install 1/4” npt male air plug to the the female air inlet on the pressure switch.
Connect the two Air Supply Lines and two Vacuum Hoses to the Pressure Switch.
Provide at least 100 PSI (7 bar) supply to the air plug on the pressure switch. To ensure dry air use a moisture fi lter (not provided).
• Connect the Air Tools.
• Make sure the correct voltage is supplied. Plug in the unit. Set On / Off control to Auto. Test the
operation of the vacuum and sander. Ensure all air fi tting connections are secure without air leakage.