TABLE OF CONTENTS
03 Installation and operation of your Unique portable AC/DC
fridge/freezer
04 Defrosting the cabinet
05 UGP-80L1 W Portable fridge/freezer: features
06 Power requirements
06 AC power connection
06 DC power connection
06 Emergency overide
07 Replacing the fuse
09 Operation
11 Error codes
11 Bluetooth APP
12 Connecting to a battery
12 Using solar panels
13 Using portable generators
14 Tips and suggestions
15 Technical specifications
16 Troubleshooting
17 Wiring diagram
18 Parts diagram and list
20 Appliance information
20 Notes
21 Contact us
21 Limited warranty
![](/html/77/77c8/77c82d7aca9d4b2de350fe91315c80fcf72f59efd6c90ee121ac3e1b2acc7900/bg3.png)
3
INSTALLATION AND OPERATION OF
YOUR UNIQUE PORTABLE AC/DC
FRIDGE/FREEZER
It is important that your fridge/
freezer is installed and operated in accordance with the
manufacturer’s instructions to
guarantee the performance,
efficiency and operation.
• Position the fridge/freezer in
a safe and secure location, out
of the reach of rain/snow and
excessive wind. Prolonged
exposure to heat sources or
direct sunlight can aect the
unit’s performance and eciency.
• The normal operation of the fridge/freezer requires heat to be radiated away from the condensers located in the end of the cabinet.
Ensure the vented areas of the cabinet are kept clear at all times to
allow adequate airflow to the compressor.
• The cooling system has been
designed to continue operating correctly when the fridge/
freezer is positioned on angles
up to 35˚. It is recommended
that the time the unit is exposed to angles over 30˚ is
limited to no more than four
(4) hours continuous operation.
IMPORTANT: After transit where the fridge/freezer is on
its side or back, ensure fridge/freezer is in a level, upright position for 3-4 hours to allow compressor fluids
to redistribute evenly before use.
![](/html/77/77c8/77c82d7aca9d4b2de350fe91315c80fcf72f59efd6c90ee121ac3e1b2acc7900/bg4.png)
4
DEFROSTING THE CABINET
If your appliance is being used primarily as a freezer, it is possible
that an ice build-up on the interior may occur. This build up can affect the performance and eciency of the cooling system and must
be removed.
Do not use pointed tools, knives or sharp utensils, or significant force
to remove the ice as this may result in damage to the unit. Turn the
fridge/freezer o and empty the cabinet of food/drinks. Allow the
ice to melt and then drain the water from the cabinet using the drain
plugs. Use a soft, clean cloth to wipe down all surfaces and allow the
fridge/freezer to dry completely.
IMPORTANT
This fridge/freezer is not intended for use by children or persons
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they are under supervision or
instruction concerning the use of the fridge/freezer by a person
responsible for their safety.
• This is not a toy. Do not allow children to play with or within the
fridge/freezer.
• The fridge/freezer is suitable for outdoor and camping use and
should not be exposed to rain or snow or other inclement weather.
INSTALLATION AND OPERATION OF
YOUR UNIQUE PORTABLE AC/DC
FRIDGE/FREEZER continued
![](/html/77/77c8/77c82d7aca9d4b2de350fe91315c80fcf72f59efd6c90ee121ac3e1b2acc7900/bg5.png)
5
UGP-80L PORTABLE
FRIDGE/FREEZER FEATURES
Protective insulated cover
DC power cord
with 10 amp fuse
Battery alligator clips12V AC power cord
Interior insulated compartment lids
Internal LED light
Powder coated
steel exterior
Stainless steel lid
latches
Protective
corners
2 x Drain
plugs
Digital
control
panel
1 x USB 2.1A
Sturdy side
handles
3 x S t o r a g e
Baskets
1 x 12V
socket
(40W
Max)
2 x USB
2.1A
Emergency
overide
![](/html/77/77c8/77c82d7aca9d4b2de350fe91315c80fcf72f59efd6c90ee121ac3e1b2acc7900/bg6.png)
6
POWER REQUIREMENTS
The Unique UGP-80L1 W portable fridge/freezers are designed to
operate on AC and DC voltage inputs.
AC input Voltage is required to be 110V AC at 50 - 60 Hz
DC input Voltage is required to be 12 or 24 DC +/- 10%
AC/DC Convertor is 12V
AC POWER CONNECTION
The Unique UGP-80L1 W portable fridge/freezers are supplied with
an approved 2 pin AC power cord. It is recommended that this cord
is not lengthened as this may result in a voltage drop and reduced
performance.
DC POWER CONNECTION
EMERGENCY OVERIDE
The Unique UGP-80L1 W portable fridge/freezers are supplied with
a vehicle DC plug (cigarette lighter plug). It is recommended that
this cord is not lengthened as this may result in a voltage drop and
reduced performance.
When connecting the fridge/freezer to DC, plug the power cord into
the DC socket on the fridge/freezer and then plug the other end of
the power cord into the DC supply.
The supplied DC power cord comes with an in-line fuse. If the red
indicator light on the DC cigarette plug is not illuminated, there is
either no DC voltage being supplied or the fuse is blown. See below
for fuse replacement instructions.
*Only use the DC power cord that is supplied with the fridge/freezer.
The emergency switch is located above the power inlet socket on
the side of the unit. If the digital thermostat fails and you are unable to set the temperature, turn this switch to Emergency override.
This enables the fridge to run until you reach a service centre to
replace the faulty component.
NOTE: If the switch is in the “ EMERGENCY OVERRIDE” position,
the fridge/compressor will run with full cooling capacity and may
freeze. This will only freeze the zone of the fridge that is currently
turned on before flicking the emergency override switch.
![](/html/77/77c8/77c82d7aca9d4b2de350fe91315c80fcf72f59efd6c90ee121ac3e1b2acc7900/bg7.png)
7
REPLACING THE FUSE
1
2-3
4-5
The Unique UGP-80L1 W portable fridge/freezers are supplied with
2 additional replacement 10A fuses for the adaptor. These can be
found in a plastic bag attached to the cord. If the indicator light on
the DC power cord is not illuminated, it could mean that the fuse has
blown. Here is how to replace the fuse:
1. Unscrew the black
plastic end cap from
the DC power plug.
2. Unscrew the metal
threaded tip of the DC
power plug to expose
the cylindrical 10 amp
fuse.
3. Remove blown fuse and
replace with a new fuse.
4. Replace metal threaded
tip of DC power plug and
screw back into place.
5. Replace black plastic
end cap of the DC power
plug and screw into
place.
Black plastic end cap
Metal threaded tip
10 A fuse
NORMAL
USE
EMERGENCY
OVERIDE
DC 12V / 24V
12 / 24V based on input
12 / 24V base sur l’entree
IT IS NOT FOR EVERYDAY USE - ONLY FOR EMERGENCIES
If the Emergency Switch is turned on. The
control panel will only show the temperature and voltage, you will not be able to
set the temperature or voltage.