fridge/freezer 04 Defrosting the cabinet 05 UGP-80L1 W Portable fridge/freezer: features 06 Power requirements 06 AC power connection 06 DC power connection 06 Emergency overide 07 Replacing the fuse 09 Operation 11 Error codes 11 Bluetooth APP 12 Connecting to a battery 12 Using solar panels 13 Using portable generators 14 Tips and suggestions 15 Technical specifications 16 Troubleshooting 17 Wiring diagram 18 Parts diagram and list 20 Appliance information 20 Notes 21 Contact us 21 Limited warranty
3
INSTALLATION AND OPERATION OF
YOUR UNIQUE PORTABLE AC/DC
FRIDGE/FREEZER
It is important that your fridge/ freezer is installed and oper­ated in accordance with the manufacturer’s instructions to guarantee the performance, efficiency and operation.
• Position the fridge/freezer in a safe and secure location, out of the reach of rain/snow and excessive wind. Prolonged exposure to heat sources or direct sunlight can aect the unit’s performance and e­ciency.
• The normal operation of the fridge/freezer requires heat to be radi­ated away from the condensers located in the end of the cabinet. Ensure the vented areas of the cabinet are kept clear at all times to allow adequate airflow to the compressor.
• The cooling system has been designed to continue operat­ing correctly when the fridge/ freezer is positioned on angles up to 35˚. It is recommended that the time the unit is ex­posed to angles over 30˚ is limited to no more than four (4) hours continuous opera­tion.
IMPORTANT: After transit where the fridge/freezer is on its side or back, ensure fridge/freezer is in a level, up­right position for 3-4 hours to allow compressor fluids to redistribute evenly before use.
4
DEFROSTING THE CABINET
If your appliance is being used primarily as a freezer, it is possible that an ice build-up on the interior may occur. This build up can af­fect the performance and eciency of the cooling system and must be removed.
Do not use pointed tools, knives or sharp utensils, or significant force to remove the ice as this may result in damage to the unit. Turn the fridge/freezer o and empty the cabinet of food/drinks. Allow the ice to melt and then drain the water from the cabinet using the drain plugs. Use a soft, clean cloth to wipe down all surfaces and allow the fridge/freezer to dry completely.
IMPORTANT
This fridge/freezer is not intended for use by children or persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are under supervision or instruction concerning the use of the fridge/freezer by a person responsible for their safety.
• This is not a toy. Do not allow children to play with or within the
fridge/freezer.
• The fridge/freezer is suitable for outdoor and camping use and
should not be exposed to rain or snow or other inclement weather.
INSTALLATION AND OPERATION OF
YOUR UNIQUE PORTABLE AC/DC
FRIDGE/FREEZER continued
5
UGP-80L PORTABLE
FRIDGE/FREEZER FEATURES
Protective insulated cover
DC power cord with 10 amp fuse
Battery alligator clips12V AC power cord
Interior insulated compartment lids
Internal LED light
Powder coated steel exterior
Stainless steel lid latches
Protective corners
2 x Drain plugs
Digital
control
panel
1 x USB 2.1A
Sturdy side
handles
3 x S t o r a g e Baskets
1 x 12V socket
(40W
Max)
2 x USB
2.1A
Emergency
overide
6
POWER REQUIREMENTS
The Unique UGP-80L1 W portable fridge/freezers are designed to operate on AC and DC voltage inputs.
AC input Voltage is required to be 110V AC at 50 - 60 Hz
DC input Voltage is required to be 12 or 24 DC +/- 10%
AC/DC Convertor is 12V
AC POWER CONNECTION
The Unique UGP-80L1 W portable fridge/freezers are supplied with an approved 2 pin AC power cord. It is recommended that this cord is not lengthened as this may result in a voltage drop and reduced performance.
DC POWER CONNECTION
EMERGENCY OVERIDE
The Unique UGP-80L1 W portable fridge/freezers are supplied with a vehicle DC plug (cigarette lighter plug). It is recommended that this cord is not lengthened as this may result in a voltage drop and reduced performance.
When connecting the fridge/freezer to DC, plug the power cord into the DC socket on the fridge/freezer and then plug the other end of the power cord into the DC supply.
The supplied DC power cord comes with an in-line fuse. If the red indicator light on the DC cigarette plug is not illuminated, there is either no DC voltage being supplied or the fuse is blown. See below for fuse replacement instructions. *Only use the DC power cord that is supplied with the fridge/freezer.
The emergency switch is located above the power inlet socket on the side of the unit. If the digital thermostat fails and you are un­able to set the temperature, turn this switch to Emergency override. This enables the fridge to run until you reach a service centre to replace the faulty component.
NOTE: If the switch is in the “ EMERGENCY OVERRIDE” position, the fridge/compressor will run with full cooling capacity and may freeze. This will only freeze the zone of the fridge that is currently turned on before flicking the emergency override switch.
7
REPLACING THE FUSE
1
2-3
4-5
The Unique UGP-80L1 W portable fridge/freezers are supplied with 2 additional replacement 10A fuses for the adaptor. These can be found in a plastic bag attached to the cord. If the indicator light on the DC power cord is not illuminated, it could mean that the fuse has blown. Here is how to replace the fuse:
1. Unscrew the black plastic end cap from the DC power plug.
2. Unscrew the metal threaded tip of the DC power plug to expose the cylindrical 10 amp fuse.
3. Remove blown fuse and replace with a new fuse.
4. Replace metal threaded tip of DC power plug and screw back into place.
5. Replace black plastic end cap of the DC power plug and screw into place.
Black plastic end cap
Metal threaded tip
10 A fuse
NORMAL
USE
EMERGENCY
OVERIDE
DC 12V / 24V
12 / 24V based on input
12 / 24V base sur l’entree
IT IS NOT FOR EVERYDAY USE - ONLY FOR EMERGENCIES
If the Emergency Switch is turned on. The control panel will only show the tempera­ture and voltage, you will not be able to set the temperature or voltage.