Unipulse LD514 Instruction Manual

INSTRUCTION MANUAL FOR THE LD514 REMOTE DISPLAY
Rev.1.08 02 Sep. 2010
Standard
LD515
comparible
A/D converter input negarive over
Net weight Net Over
Total weight Maximum scale value + 9 divisions
Total weight Total quantity over
Tare quantity > 99999
Loadcell Indicator
CZ ZT MD ZALM TARE NET GROSSHOLD
LD514 EXTERNAL DISPLAY
HOLD
When the indicator is in one of the following states, this LED comes on.
- The indicated weight value is held.
- The hold signal is input in the rear panel terminal base.
- The digital indicator status is HOLD.
GROSS
When the indicated weight value is a total weight, this LED comes on.
NET
When the indicated weight value is a net weight, this LED comes on.
TARE
When the indicated weight value is a tare weight or the indicator is in the tare subtraction status, this LED comes on.
CZ
When the indicator is within ± 1/4 scale division from the zero point, this LED comes on to indicate the true zero point.
ZT
When the indicator is Zero Tracking (ZT), this LED comes on.
MD
When the indicator status is stable, this LED comes on. (This may come on in the unstable status depending on the indicator type.)
ZALM
When the indicator status is Zero Alarm (ZALM), this LED comes on.
kg
N
t
g
Unit of weigt
The unit of weight value is none at delivery. Select a necessary unit indication from attached unit seals and paste it at a proper position.
l
b
Negative sign indicating digit
Digital Indicator
(※ This indicator is based on the
overflow indication of our F360A series, so the indication may be different from the indication of the LD514 main unit depending on the
indicator that is connected.
A/Dconverter over scale
A/Dconverter over scale
Indicated value > 99999
      Connection Fault Indication
When the dedicated serial interface input short-circuits or wire breaking occurs, or when the rotary switch is not selected correctly, blanking (all digit OFF) takes place and all the status indicating LEDs come on.
In this case, check the following items and take a proper
measure.
- When the dedicated serial interface is used, check if it is correctly connected or any wire breaking does not occur.
- Check if the rotary switch is set according to the specified number.
- Check if the indicator is normally operated.
When the all-digit indicating part and the status indicating LEDs do not come on, check the following item and take a proper measure.
- Check if the power supply (100 to 220 V AC) is correctly input.
FRONT PANEL
Numeric display part
This part indicates the following 7 types of value.
- Total weight
- Net weight
- Tare weight
- Load cell indicator interrelated value (Standard mode)
- Load cell indicator interrelated value (LD151 compatible mode)
- Digital indicator interrelated value
- Over-scale indication
    Self-check (self-diagnosis) method
The LD514 can make a self-diagnostic test by special operation or a command from the indicator. If any fault is not found by self-diagnostic test (ROM check), a visual check is started in succession. At the visual check, a decimal point and a number of 0 to 9 are displayed for each digit on the display unit. Visually check if the numeric value can be normally indicated.
The self-check is made in the following two cases.
- The power supply is turned on after the rotary switch is set to the self-check mode.
When the rotary switch is set to No.8 and then the power supply is turned on, the check is repeated until this setting on the rotary switch is changed.
- A self-check command is given from the indicator that is connected. For making a self-check, the load cell indicator such as F805 outputs a check command to the LD154. Some types of indicator may not output a check command. For details, refer to the instruction manual for the respective indicator.
Visual check
If the indication is provided as shown above, the display unit is normal.
→→→→
→→→→
→→→→
→→→→
→→→→
→→→→
→→→→
→→→→
→→→→
→→→→
→→→
→→→→
→→→→
LN
AC IN
HOLD SI F
F. G.
SET
8
0
4
8
C
1
5
9
D
2
6
A
E
3
7
B
F
9
SI/F terminal base
This is a terminal base for SI/F input (two-wire serial interface input). The applicable wire material is a parallel 2-core cable, cabtyre cable, etc.
SIF
Frame ground
This is a grounding terminal. Be sure to ground this F.G terminal to prevent an electric shock and a fault due to static electricity.
AC power supply input terminal base
Connect the attached AC power cable.The input voltage is 100 to 240 V AC and the frequency is 50/60 Hz.
Unipulse Corporation
9-11 Nihonbashi Hisamatsucho, Chuo-ku, Tokyo, 103-0005 Tel. +81-3-3639-6120 Fax. +81-3-3639-6130
Hold input terminal base
To hold the indicated value, strap these two terminals. The right-hand terminal is a COM terminal.
HOLD
+
-
Open-circut OFF
Short-circuit ON
Vcc Iso
COM
Ic=Approx. 6mA
Input circut
REAR PANEL
Indication contents selecting rotary switch
Various data from the indicator can be selected and displayed by changing over the rotary switch. The decimal point automatically follows the setting from the indicator.
SW No. Contents of indication
0 Total weight indication
1 Net weight indication
2 Tare weight indication
3
Load cell indicator interrelated value (normal mode)
4
Load cell indicator interrelated value (LD151 compatible mode)
5 Digital indicator
interrelated value
8 Self-check mode
0
4
8
C
1
5
9
D
2
6
A
E
3
7
B
F
SET
External Dimensions
The plate thickness of the mounting panel is 1.5 mm or more.
Unit :mm
92
+0.8
-0
96 56.8
45
+0.6
-0
FRONT VIEW >< SIDE VIEW >
(4)
LN
AC IN
HOLD S IF
F.G.
SET
8
0
4
8
C
1
5
9
D
2
6
A
E
3
7
B
F
91
CZ Z T MD ZALM TARE NET GROSSHOLD
LD514
EXTERNAL DISPLAY
48
2.5
442 2
2.5
REAR VIEW
PANEL CUT
DIMENSIONS
Connecting to Cage Clamp Terminal Block
As the SI/F terminal and hold input terminal is using the cage clam system terminal stand, connecting is simple.
1.Strip the casing 0.2in(6mm) on the cable to be connected.
2.Twist the bare wire to fit the terminal hole.
3.Insert the supplied screwdriver into the upper hole and lift upward
4.Insert he twisted wires into the lower hole.
5.Pull the screwdriver out from the upper hole.
6.Make sure cable is clamped securely and does not come
out wight a slight tug.
Cable can be from 24 to 12AWG (0.2 to 2.5MM
2
). It is not necessary to solder the cable wires or to fix a solderless terminal
If several cables to be inserted to the same hole,
twist those cable wires together and insert.
0.2in(6mm)
       About the power cable
The power cable attached to this product as standard
equipment can be used in the AC100V power supply in Japan. (Official ratings voltage AC125V) Please use the power cable authorized in the country when you use this product outside Japan.
Our company sells following resistance pressure
cable AC250V (European standard product) sepa­rately. Please purchase it from us when you need after con­firming its plug shape/voltage.
CAAC3P-CEE7/7-B2
: CEE7/7 Plug cable (2m)