The OPERA and OPERA eco are multi-user, electric powered breast pumps intended to express and
collect breast milk.
USAGE ENVIRONMENT
Use Environment: Home or health care settings.
WARNINGS
IMPORTANT SAFEGUARDSWARNING: To reduce the risk of burns, electrocution, re, or injury to persons:
- For Opera eco, always unplug this device immediately after use. For Opera, unplug the device immediately
after use, if it is plugged in during use.
- Separation from the power outlet is only assured through the disconnection of the plug and socket connection.
- Do not use while bathing.
- Make sure the voltage of the device is compatible with the power source.
- Do not reach for a device that has fallen into water. If this occurs, unplug the device immediately.
- This device should never be left unattended when plugged in.
- Close supervision is necessary if operating this device near infants or children.
- Only use certied AC 14V DC, 2A adapter and cables provided by the manufacturer.
- Only use the device accessories as outlined in the manual.
- Only use this device for its indication for use as described in the manual.
- Never operate an electrical device if it has a damaged cord or adapter, if it is not working properly, if it has been
dropped or damaged, or if it has been dropped into water.
- Do not place in or drop motor unit into water or other liquid.
- Keep the device away from heated surfaces.
- Never use while sleeping or drowsy.
- Do not try to disassemble or modify this device.
- This equipment is not suitable for use in the presence of a ammable anesthetic mixture.
- Replacing the battery by user is not permitted. please contact your local distributor or manufacturer if you
need to change the battery.
- Keep the tubes out of the reach of children.
- If you are a mother who is infected with Hepatitis B, Hepatitis C, or Human Immunodeciency Virus (HIV), pumping
breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.
Caution : When using electrical products, always read all instructions and
follow basic safety precautions.
NO.Accessory
| 1
CAUTIONS
- Do not expose the breast pump to direct sunlight.
- If you feel pain in your breast or nipple, turn the pump o or slide a nger between the ange and your breast to immediately
break the suction.
- Contact a healthcare professional or breastfeeding specialist if you experience problems or pain.
- Portable and mobile radio frequency communications equipment can aect the Opera breast pump.
- Wash hands thoroughly with soap and water before touching breast pump, kit and breasts and avoid touching the inside of
containers or lids.
- Separate and wash all parts that come in contact with breast milk immediately after use to avoid dry up of breast milk residue
and prevent growth of bacteria. Always inspect breast shields, connectors, valves, membranes and tubing prior to use for
cleanlines
- Do not store wet or damp parts as mold may develop.
- If tubing becomes moldy, discontinue use and replace tubing. Contact the manufacturer or authorized distributor.
- While some discomfort may be felt when rst using a breast pump, using a breast pump should not cause pain.
PUMPING TIPS
- Eat lactation-friendly foods to increase your milk production.
- Stay hydrated and avoid coee and alcohol.
- Set yourself up for success by making things easy on yourself. Stress can inhibit let-down and milk production.
- Use warm compresses and massage your breasts while pumping. Not only will this keep ducts from becoming clogged,
but it will also ensure every last drop of milk is removed from your breasts, helping to increase your milk production.
- Make sure you’re pumping long enough to stimulate multiple let-downs.
- For maximum milk expression, we recommend that you pump more frequently but in short increments.
(10-15 minutes per breast, every 2-3 hours, 7-8 times a day.)
- If pain occurs, consult your lactation consultant or physician.
OPERATING GUIDE
- Clean your hands and sanitize the kit before using the breast pump.
- Make sure you have the proper breast shield size for you.
- Press the power button gently for 1-2 seconds to turn the pump on.
- Position the nipple in the center of the breast shield.
- Start on massage mode to stimulate your let-down reex. After 2 - 3 minutes, switch to expression mode to eectively
collect breast milk.
- Increase or decrease vacuum level and cycles until you nd the most comfortable setting for you.
- Turn the unit o after use.
* Memory feature : When you turn on the pump, Opera will automaticaly will start on the last setting used.
Caution : Do not twist or bend the air tube. Do not overll the collection bottle.
TRANSPORTATION & STORAGE
Recommended transportation and storage conditions
- Temperature range: - 25º C ~ + 70º C
- Relative humidity range: Under 93%, non-condensing
*If the device has been stored at temperature outside the recommended range, it’s necessary for the device to stay at room temperature
for approximately 1 hour before operating.
2 |
LABELS & SYMBOLS
No.
Graphic of the symbol
1
Referenced Standard
ISO 7000
Reference numberTitleDescription
ISO 7000-1641
Protection agains
electric shock
Class II
2
3
4
5
6
7
REF
+70
-25
8
9
10
11
12
93
0
13
ISO 60417
ISO 7010
ISO 7000
IEC 60529
ISO 7000
ISO 7000
ISO 7000
ISO 7000
ISO 7000
ISO 7000
ISO 7000
ISO 7000
ISO 60417-5333
ISO 7010-M002
ISO 7000-3082
IEC 60529
ISO 7000-2493
ISO 7000-0632
ISO 7000-0632
ISO 7000-0626
ISO 7000-0624
ISO 7000-2620
ISO 7000-2620
ISO 7000-2498
Applied part
Instructions for Use
Manufacturer
Protection against solid
foreign objects and water
Catalogue Number
Temperature limit
Temperature limit
Keep dry
Avoid Sunlight
Fragile, handle with care
Humidity Limit
Humidity Limit
Type BF
Refer to IFU
Name/Address of
the Manufacturer
Protection against solid
foreign objects and water
Indicates the manufacturer’s
catalogue number
Temperature range
Temperature range
Protect from moisture
Protect from direct sunlight
Handle carefully
Humidity range
Humidity range
14
15
16
17
18
80kPa
19
ISO 7000
ISO 7000
ISO 7000
ISO 60417
ISO 60417
EN 50419
ISO 7000-2498
ISO 7000-0434A
ISO 7000-2497
ISO 60417-5009
ISO 60417-2621
EN 50419
Serial Number
Caution
Date of manufacture
Stand-by
Atmospheric Limit
Serial Number
Caution
Indicates the date when
product was
manufactured
On/O Button
Atmospheric
pressure range
WEEE SYMBOL
| 3
CLEANING INSTRUCTIONS
The Opera breastpump may be cleaned with wipes or a non-abrasive detergent for general cleaning.
However, the Opera should be disinfected between use by dierent mothers. Please follow the steps to clean or disinfect
your Opera Breastpump.
Separate and wash all parts that come in contact with breast milk immediately after use to remove breast milk
residue and prevent growth of bacteria. Only use drinking-quality tap or bottled water for cleaning.
Wash before rst use and after each use.
- Rinse all separated parts that come in contact with the breast and breast milk in cool water
to remove breast milk residue.
- Soak with warm soapy water in sink for 5 minutes with clear water, then wash and rinse.
- Place parts on a clean surface and/or towel. Allow parts to air dry.
- Store dry parts in a cool place when not in use.
- Do not store wet or damp parts.
Dishwasher cleaning.
- Wash all separated parts by using the top rack of your dishwasher.
- Place parts on a clean surface and/or towel. Allow parts to air dry.
- Store dry parts in a cool place when not in use.
- Do not store wet or damp parts.
Sanitize before rst use and once per day.
- Fill pot with water to cover all parts and bring to a boil.
- Place parts in boiling water for 10 minutes.
- Place parts on a clean surface and/or towel.
- Allow parts to air dry.
- Store dry parts in a cool place when not in use.
- Do not store wet or damp parts.
Caution : Never submerge the pump body in water or any liquid.
DISPOSAL
- Please dispose of this product according to your local collection requirements. Improper disposal
could result in harmful eects on the environment.
PUMPING MODES
Opera and Opera Eco have Massage and Expression Modes.
- Massage mode features a fast sucking/pumping rhythm to stimulate milk ow.
- Expression mode features a slower sucking/pumping rhythm for gentle and ecient milk removal after milk has started owing.
Opera also allows you to operate 4 dierent pumping styles: Single left, single right, synchronous, and alternate.
DescriptionMode
4 |
Single Mode
Synchronous Mode
Alternate Mode
Left
One side pumping (left side)
Right
One side pumping (right side)
Double pumping for both sides at the same time
During the Alternate Mode, each side will be pumped every 1 minute as shown below.
[01] Power button: Turn on/o the device.
*Memory function: The last mode setting used before turning o the device will be automatically
stored when turning back on the device.)
[02] Massage / Expression button: Select Massage or Expression mode.
[03] Massage / Expression mode display: Current mode will appear on the screen.
[04] Mode button: Mode setting of Single Left Single Right, Synchronous, or Alternate mode.
[05] Mode display: When pressing the mode button [04], the selected mode will appear on the screen.
- Single Left Mode [SINGLE L].
- Single Right Mode [SINGLE R].
- Synchronous Modes [SYNCHRONOUS].
- Alternate Mode [ALTERNATE].
[06] Pumping side indicator: Pumping side indicator will blink showing current side used.
[07] Vacuum button: Press the [+] button to increase the vacuum level and the [-] button
to decrease the vacuum level.
[08] Vacuum level display: Press the vacuum button [7] to display the current level on the screen.
- Massage mode up to 5 levels.
- Expression mode up to 8 levels.
[09] Cycle button: The number of cycles per minute will increase by pressing the [+] button and will decrease
by pressing the [-] button.
- Massage mode cycle/min : 60 ~ 100.
- Expression mode cycle/min: 26 ~ 42.
[10] Cycle display: Press cycle button [8] to display cycle/min on the screen.
- When using [SINGLE L], numbers will be displayed on the left.
- When using [SINGLE R], numbers will be displayed on the right.
- When using [SYNCHRONOUS] or [ALTERNATE] modes, numbers will be displayed on both sides.
[11] Usage time display: Usage time will be displayed.
[12] A/S mode: Contact manufacturer if A / S mode is displayed on the screen.
[13] Battery indicator: Remaining battery life will be displayed.
[14] Night light button: Adjustable 3 levels of night light functions.
| 5
Massage Mode
[Massage Mode]
Vacuum control button
(5 levels)
SINGLE Left Mode
will blink as per current side usage
Pumping indicator
Left display
+ Increase ↑
- Decrease ↓
A L T E R N A T E
SINGLE Left Mode
- Single Left Mode [SINGLE L]
– Single Right Mode [SINGLE R]
* All components are available to be purchased from the manufacturer or your local distributor.
ASSEMBLY INSTRUCTIONS
01
020304
07
01
Diaphragm cap
02
K-pop diaphragm
03
Breast shield
04
08
09
10
11
White valve
05
Bottle
06
Bottle stand
07
Silicone massager
08
Bottle cover
09
Nipple
10
Cap
11
Disk
12
Air tube
13
Air tube connector
14
Main body
15
AC adapter
0910
8 |
0605
07
08
Note: The specially designed massager
encourages milk ow while providing
maximum comfort. Suction power
can slightly decrease while using the
silicone massager.
THAWING & WARMING TIPS
- Thaw the oldest breast milk rst.
- Breast milk does not need to be warmed. Some moms prefer to serve it at room temperature.
- Thaw the bottle or bag of frozen milk by putting it in the refrigerator overnight.
- If you decide to warm the breastmilk:
- Keep the container sealed while warming.
- Hold it under warm running water, or set it in a container of water that is warm, not hot.
- Never put a bottle or bag of breast milk in the microwave, as it creates hot spots that could
-
burn your baby and damage the milk.
- Test the temperature before feeding it to your baby by dropping some on your wrist. The milk should
-
feel warm, not hot.
- Swirl the milk to mix the fat, which may have separated. Do not shake the bottle.
-
Use breast milk within 24 hours of thawing it in the refrigerator. This means 24 hours from when the
-
breast milk is no longer frozen, not from when you remove it from the freezer.
- Once breast milk is thawed to room temperature, use it within 2 hours. If you have any leftover milk after
-
the baby is nished feedi
- Do not refreeze breast milk after it has been thawed.
ng, be sure to throw it out after 2 hours of usage.
BREAST MILK STORAGE
After each pumping session, you can:
-
- Keep breast milk at room temperature. Breast milk is ok for up to 4 hours after pumping at room temperature (up to 77°F).
-
- Refrigerate the breast milk. Breast milk is ok in the refrigerator for up to 4 days.
-
- Place breast milk in the freezer. If you're not going to use refrigerated breast milk within 4 days, freeze it right after pumping.
- Use cooler packs. You can put the breast milk in a cooler or insulated container with frozen ice packs for up to 24 hours
after pumping. After 24 hours in a cooler the breast milk should be refrigerated or frozen.
-
- Breast milk can be stored in the freezer (0 °F or colder) for 3 to 6 months.
- When storing breast milk, use breast milk storage bags, which are made for freezing human milk. You can also use
a clean glass container or BPA-free plastic bottles with tight-tting lids. Do not use containers with the recy
which may contain BPA. Do not use disposable bottle liners or other plastic bags to store breast milk.
- Storage bottles or bags to refrigerate or freeze your breast milk also qualify as tax-deductible.
Most insurance plans must cover breastfeeding supplies, such as storage bags, in addition to breast pumps.
Call your insurance company to learn more.
Storage: Tips for freezing breast milk:
- Clearly label breast milk containers with the expression date. Include your child's name if you
are giving the milk to a child care provider.
- Freeze in small amounts (2 to 4 ounces, or ¼ to ½ cups) for later feedings.
- Leave an inch or so from the top of the breast milk container, as it will expand when freezing.
- Wait to tighten bottle caps or lids until the milk is completely frozen.
- Store breast milk in the back of the freezer, not by the shelf of the freezer door, to avoid thawing out.
Reference: https://www.cdc.gov/healthywater/pdf/hygiene/breast-pump-fact-sheet.pdf
cle number 7,
The Essential Performances of the OPERA & OPERA eco are as follows:
Performance Reference
Expression Mode
(During charging / operating mode)
Pressure
Backow Protection
(During charging / operating mode)
Massage Mode
(During charging / operating mode)
set pressure ± 10% mmHg, Max 280 mmHg
Description
set pressure ± 10% mmHg
No Backow occurs
| 9
BATTERY, CYCLE AND VACUUM INFORMATION
*
The dierence between OPERA and OPERA eco is that the OPERA has a echargeable battery while the OPERA eco doesn'
The following battery information is only applicable to the OPERA model.
BATTERY STATUS
Operating time remaining (approx.)
Massage - Single L mode (suction in mmHg)Massage - Single R mode (suction in mmHg)
Cycle/min
Level
60
708090100
1
45
45
2
60
60
3
90
90
4
120
120
5
150
150
Massage – Synchronous mode (suction in mmHg)Massage – Alternate mode (suction in mmHg)
Level
Cycle/min
1
2
3
4
5
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
708090100
60
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
Expression – Single L mode (suction in mmHg)Expression – Single R mode (suction in mmHg)
Cycle/min
26
Level
1
2
3
4
5
6
7
8
30343842
90
90
140
140
170
170
200
200
230
230
250
250
270
270
280
280
Expression – Synchronous mode (suction in mmHg)Expression – Alternate mode (suction in mmHg)
Cycle/min
Level
2630343842
1
2
3
4
5
6
7
8
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
4 BAR
(FULLY CHARGED)
2 hours1.5 hours
45
60
90
120
150
(45,45)
(45,45)
(60,60)
(60,60)
(90,90)
(90,90)
(120,120)
(120,120)
(150,150)
(150,150)
90
140
170
200
230
250
270
280
(90, 90)
(90, 90)
(140,140)
(140,140)
(170,170)
(170,170)
(200,200)
(200,200)
(230,230)
(230,230)
(250,250)
(250,250)
(270,270)
(270,270)
(280,280)
(280,280)
Charging Time (approx.)
45
60
90
120
150
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
90
140
170
200
230
250
270
280
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
140
170
200
230
250
270
280
120
150
90
3 BAR
2 BAR
1 hour
1 BAR
20 minutes
NO BAR
Less than 5 Minutes
3 hours
Cycle/min
Level
45
60
90
1
2
3
4
5
Cycle/min
Level
(45,45)
1
(60,60)
2
(90,90)
3
4
(120,120)
5
(150,150)
Cycle/min
Level
Level
2630343842
1
90
2
140
3
170
4
200
230
5
250
6
270
7
8
280
Cycle/min
2630343842
1
(90, 90)
2
(140,140)
3
(170,170)
4
(200,200)
(230,230)
5
(250,250)
6
7
(270,270)
8
(280,280)
708090100
60
45
45
60
60
90
90
120
120
150
150
708090100
60
(45,45)
(45,45)
(60,60)
(60,60)
(90,90)
(90,90)
(120,120)
(120,120)
(150,150)
(150,150)
90
140
170
200
230
250
270
280
(90, 90)
(90, 90)
(140,140)
(140,140)
(170,170)
(170,170)
(200,200)
(200,200)
(230,230)
(230,230)
(250,250)
(250,250)
(270,270)
(270,270)
(280,280)
(280,280)
120
150
140
170
200
230
250
270
280
45
45
60
60
90
90
120
150
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
90
90
140
170
200
230
250
270
280
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
t.
45
60
90
120
150
(45,45)
(60,60)
(90,90)
(120,120)
(150,150)
90
140
170
200
230
250
270
280
(90, 90)
(140,140)
(170,170)
(200,200)
(230,230)
(250,250)
(270,270)
(280,280)
10 |
TROUBLESHOOTING
OPERA
Check if the malfunction
occurs when operating
the controls.
Check if the AC adapter
is conected.
Check if all accessories are
properly installed.
Check the valve for
damages.
Check if the device
is able to turn on.
Unplugged the AC adapter and
turn o the device. Then plug the
AC adapter back into the device.
Plug the AC adapter to a
power outlet.
disassemble and
reassemble all accessories.
If the device is not turning on,
connect it to the AC adapter
to charge the battery.
Adjust the suction level as
needed. If you still experience
pain or discomfort, please
contact a lactation consultant
or physician.
Lost or broken parts : Spare parts are available from the location where you purchased
the product or the manufacturer.
| 11
EMC
OPERA /OPERA eco
OPERA /OPERA eco
in such an environment.
OPERA /OPERA eco
OPERA /OPERA eco
OPERA /OPERA eco
supply
OPERA /OPERA eco
12 |
location
OPERA
OPERA
OPERA
OPERA
OPERA
* The National Deviation of the US, which is UNITED STATES NATIONAL DIFFERENCES
(National standard ANSI / AAMI ES60601-1” 2005) , is applied.
Caution
Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in
improper operation. If such use is necessary, this equipment should be observed to verify that they are operating
normally.
Use of accessories, transducers and cables other than those specied or provided by the manufacturer of this
equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this
equipment and result in improper operation.
Portable RF communications equipment (including peripherals such as antenna cables and external antennas)
should be used no closer than 30cm (12 inches) to any part of the OPERA and OPERA eco, including cables specied
by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
UM-IFU-OP
REF
Revision No.01
ISSUED date 22.Oct.2018
| 13
SPECIFICATIONS
AC Adaptor 14V DC, 2.0A Vaccum range: Max=280mmHg
Certied AC adapter can be purchased separately.
Firmware Version: OPR_1.0 Rev-1.0
Expected Service Life Time Battery or device : 2 year
Adapter input : AC100~240V, 50/60Hz, 0.8A
Battery : 11.1V DC, 2200mAh (OPERA Only)
LIMITED WARRANTY
For a period of 2 year from the date of original purchase, Unimom warrants this product (excluding accessories)
against defects in material or workmanship. At Unimom’s option, Unimom may repair or replace the item that is
determined to be defective by Unimom and determined to be covered by this warranty.
For warranty service, please return the product, along with dated sales receipt or other proof of the
purchase date, to Unimom or Local distributor.
This warranty does not cover damage caused by accident, misuse, abuse, improper maintenance, unauthorized
modication, or connection to an improper power supply. A charge will be made for repair of such damage.
This warranty excludes all incidental or consequential damages and any liability other than what is stated above.
Unimom makes no other warranties regarding this product either express or implied.
WARRANTY CARD
OPERA / OPERA eco
Origin : Republic of Korea
14 |
Unimom Co.
110-19, Gajangsaneopseobuk-ro, Osan-si, Gyeonggi-do, 18102, KOREA
Tel : +82-70-8798-5577 / Fax : +82-31-372-6782
E-mail : info@unimom.com / infounimom@naver.com
Web : www.unimom.com
Unimom USA.
3020 NW 27th Street, Fort Lauderdale, Florida 33311
Tel : +1- 954-858-5588 / Fax : +1-754-217-2738
E-mail : info@unimomus.com
Web : www.unimomusa.com
OPERA / OPERA eco Double Electric Breast pump
Name
Telephone
Mobile Phone
Address
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.