PA Series Installation Guide
Wiring and Circuit Diagram
Model PA
Excitation Voltage: 25 VDC or VAC Max.
Potentiometer Resistance: 1000 ohms ±10%
Note: Any input voltage up to the maximum specified above
may be used. However, for best performance, the input
voltage should be closely regulated to insure a stable and accurate output voltage.
Dimensional Information
Ranges to 50" (1250 mm) Ranges to 80" (2000 mm)
Range
2”, 10” 0.66 16.8
3”, 15”, 30” 0.51 12.9
4”, 20”, 40” 0.35 8.8
5”, 25”, 50” 0.19 4.8
“A”
(in.) (mm.)
*
*
* 1.56 (39.6 mm) with "DS" option.
* 1.56 (39.6 mm) with "DS" option.
4175 SW Research Way, Corvallis, Oregon, 97333
•Tel: (541) 757-3158 •Fax (541) 757-0858

OPTION "CES" SIDE CABLE EXIT
PA, PB, P420, P510, P1010, EP, V, VP SERIES
PA, PB, P420, P510, P1010
RANGE
DIMENSION "A" DIMENSION "B"*
2”, 10” 1.52" (38.6 mm) 1.28" (32.5 mm)
3”, 15”, 30” 1.68" (42.7 mm)** 1.28" (32.5 mm)
4”, 20”, 40” 1.84" (46.7 mm)** 1.28" (32.5 mm)
5”, 25”, 50” 1.97" (50.8mm)** 1.28" (32.5 mm)
60" 2.53" (64.3 mm) 1.78" (45.2 mm)
75" 2.76" (70.2 mm) 1.78" (45.2 mm)
80" 2.84" (72.2 mm) 1.78" (45.2 mm)
RANGE
DIMENSION "A" DIMENSION "B"*
2”, 10” 1.58" (40.1 mm) 1.68" (42.7 mm)
3”, 15”, 30” 1.74 (44.2 mm)** 1.68" (42.7 mm)
4”, 20”, 40” 1.90 (48.3 mm)** 1.68" (42.7 mm)
5”, 25”, 50” 2.03 (52.3 mm)** 1.68" (42.7 mm)
60" 2.59 (65.8 mm) 1.68" (42.7 mm)
75" 2.82 (71.6 mm) 1.68" (42.7 mm)
80" 2.90 (73.7 mm) 1.68" (42.7 mm)
* With "DS" (dust shield) option, add 0.36" (9.1 mm) to "B" dimensions above.
** With "HG" (high wire rope tension) option, add 0.375" to dimension shown
for 30", 40" and 50" measurement ranges only.
EP, V SERIES
VP SERIES
OPTION "CEB" BOTTOM CABLE EXIT
PA, PB, P420, P510, P1010, EP, V SERIES
RANGE DIMENSION "A"
2”, 10” 1.34 (34.0 mm)
3”, 15”, 30” 1.49 (37.8 mm)
4”, 20”, 40” 1.65 (41.9 mm)
5”, 25”, 50” 1.81 (46.0 mm)
60" 1.96 (49.8 mm)
75" 2.20 (55.9 mm)
80" 2.28 (57.9 mm)
With "DS" dust shield
option, add 0.36" (9.1
mm)
4175 SW Research Way, Corvallis, Oregon, 97333
•Tel: (541) 757-3158 •Fax (541) 757-0858