ASD-10QR
smoke alarm using radio links
User Manual
Safety issues
Please follow the recommendations:
• Loud test signal will sound during the function test (see Test mode). Keep safe distance of 50 cm
between your ear and the alarm.
• Do not paint the alarm.
• Do not locate smoke alarms in highly vapourized premises such as bathrooms, saunas and kitchens
Features
• Q-label for higher quality
• Infinite number of smoke alarms can be radio interlinked with possibility to transmit Remote Alarm
and Remote low battery signals.
• Simple generation of the unique code and wireless interlinking
• Different sounding of Alarm and Remote Alarm modes
• Secure fire detection by intellectual sensitivity calibration using integral microcontroller and
intellectual analysis of smoke chamber signal
• Drift compensation (including smoke chamber contamination). This mechanism automatically
adjusts sensitivity of the smoke alarm to the factory level during operation

• Audible indication of exceeding the threshold compensation level (signal to cleaning the smoke
chamber from dust)
• New technical solutions were applied thanks to which influence of electromagnetic interferences
and temperature change has been reduced.
• Different ways of mounting (screws/adhesive pads)
• Fluent sound volume increase (fade-in) in Alarm, Remote Alarm and Test modes
• Hush function – muting of local alarm signal for approx. 10 min. by pushing the Test button.
•
You will hear a sound signal of the last fault when removing the alarm from the base
• You will hear the relevant sound signal in case of fault when removing the alarm from the base
•
Supports test RF remote control
Specifications
Standby current consumption ≤ 12 µА
Alarm current consumption ≤ 90 mА
RF frequency 868.100 (<1% duty cycle)
RF Codes 65535
RF Power +14 dBm max
RF range 100 meters min air free
Battery life at least 10 years under normal conditions
Battery type sealed, Lithium, AA, 3.0V
Hush time 10 ±2min.
Alarm and Remote Alarm sound level > 85dB at 3 m
Light and sound indication
emote Alarm, low battery,
remote low battery, smoke chamber fault,
exceeding the ultimate compensation level
(see Sound and Light signals table)
Operating temperature range 0 – 55° C
Operating humidity < 93% RH at 40° C
Dimensions Ø80 х 45 mm
Approvals
EN 14604, CE, VdS3131, VdS
R&TTE
Audible and visual signals
Audible signal Red LED Function
No signal flashes every 320 sec
periodical automatic self-diagnostics
Long intermittent
signal
flashes every 0.5 сек. Alarm status
signal
(different from the
latter)
off
Remote Alarm status.
One of the interlinked alarms went to Alarm
status