Unika A-500, A-800, A-1300 User Instructions

User Instructions
Professional Power Amplif iers
POW ER
ON
OFF
LIMI TER
ON
0
SIGNA L
-20dB
-10dB
CLIP
PROTE CT
POWER
PROFESSIONAL POWER AMPLIFIER
LIMI TER
ON
0
10
POW ER
ON
OFF
LIMI TER
ON
0
SIGNA L
-20dB
-10dB
CLIP
PROTE CT
POWER
PROFESSIONAL POWER AMPLIFIER
LIMI TER
ON
0
10
POW ER
ON
OFF
0
SIGNA L
-20dB
-10dB
CLIP
PROTE CT
POWER
PROFESSIONAL POWER AMPLIFIER
0
10
UNiKA
A-500
UNiKA
A-800
UNiKA
A-1300
UNiKA
This symbol is intended to alert the user to the presence of non insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
CAUTION: Risk of the electrical shock - DO NOT OPEN! CAUTION: To reduce the risk of electrical shock, do not remove cover. No user serviceable parts inside. Refer all servicing to qualified s ervice personnel.
WARNING: To prevent electrical shock or f re hazard, do not expose this amplifier to rain or moisture. Before using this amplifier r ead the user manual for further warnings.
Ce symbole est utilisé pur indiquer à l’utilisateur la présence à l'intérieur de ce produit de tension non-isolée dangereuse pouvant être d'intensité suff sante pour constituer un risque de choc électrique.
Ce symbole est utilisé pour indiquer à l’utilisateur qu'il trouvera d'importantes instructions importantes sur l'utilisation et l'entretien de l'appareil dans la littérature accompagnant le produit.
ATTENTION: Risque de choc électrique - NE PAS OUVRIR! ATTENTION: Afin de réduire le risque de choc électrique, ne pas enlever le couvercle. Il ne se trouve à l’intérieur aucune piéce pouvant être réparée par l'utilisateur. Confier l'entretien à un personnel qualif é.
AVERTISSEMENT: Afin de prévenir les risque de décharge ou de feu, n’exposez pas cet appareil à la pluie ou à l’humidité. Avant d’utiliser cet amplificateur, lisez les aver­tissements supplémentaries situés dans le guide.
ATTENTION: ATTENTION:
AVERTISSEMENT:
Este símbolo tiene el propósito de alertar al usuario de la presencia de “voltaje peligroso“ que no tiene aislamiento dentro de la caja del producto que puede tener una magnitud suf ciente como para constituir riesgo de corrientazo.
Este símbolo tiene el propósito de alertar al usuario de la presencia de instrucciones importantes sobre la operación y mantenimiento en la literatura que vienc con el producto.
PRECAUCIÓN: Riesgo del choque eléctrico - NO SE ABRA
PRECAUCIÓN: Para disminuir el riesgo de choque eléctrico, no quite la cubierta. No hay piezas adentro que el usario puede reparar. Deje todo mantenimiento al los téc-
nicos cualif cados.
ADVERTENCIA: Para prevenir choque eléctrico o riesgo de incendios, no deja expuesto a la lluvia o a la humedad este amplif cador. Antes de usar este amplif cador, lea mas advertencias en la guia de operacion.
PRECAUCIÓN:
ADVERTENCIA:
mas advertencias en la guia de operacion.
Dieses Symobl soll den Anwender vor unisollierten gefährlichen Spannungen innerhalb des Gehäuses warnen, die von Ausreichender Stärke sind, um einen elek­trischen Schlag verursachen zu können.
Dieses Symobl soll den Benutzer auf wichtige Instruktionen in der Bedienungsanleitung aufmerksam machen, die Handhabung und Wartung des Produkts betref­fen.
VORSICHT: Risiko - Elektrischer Schlag! Nicht öffnen! VORSICHT: Um ddas Risiko eines elektrischen Schlages zu vermeiden, nicht die Abdeckung enfernen. Es bef nden sich keine Teile darin, die vom Anwender repariert
werden könnten. Reparaturen nur von qualif zierte Fachpersonal durchführen lassen.
ACHTUNG: Um einen elektrischen Schlag oder Feuergefahr zu vermeiden, sollte diesen Gerät nicht dem Regen oder Feuchtigkeit ausgesetz werden. Vor Inbetriebnahme unbedingt die Bedienungsanleitung lesen.
ACHTUNG:
page 2
CAUTION: TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE THE COVER.
THERE ARE NO USER SERVICEABLE PARTS
INSIDE. REFER ALL SERVICE TO YOUR
AUTHORIZED AMERICAN AMX DEALER.
CAUTION
Do not open -
risk of electric shock
The lightning flash with an arrow triangular symbol is intended to alert the user to the presence of non insulated “dangerous volt­age” wit hin the products enclosu re, and may be of sufficient magnitude to consti­tute a risk of electric shock.
The exclamation point triangular symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the user manual accompanying the amplifier.
page 3
CONTENTS:
Introduction..... ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ......................................4
Front Panel........... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ................... ............5
Rear Panels
A-500................... ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... .............................6
A-800................... ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... .............................7
A-1300.................. ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ............................8
Inputs................. ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ..................................9
Outputs............. ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... .................................9
Operating Modes. ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ..............................13
Protection Circu itr y
Limiter................. ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ............................13
Short Circuit Protect ion ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ........................13
Ther mal P rot ect ion ............................................................. ... ... ... ... ... ... ... ... ... .........................................................14
Low Cut Filter........... ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... .....................14
Specifications ... ... ... ... ... ... ... ... ... ... ............................................................. ... ... ... ... ... ... ... ... ... ... ...................................15
..
FOR OPTI MUM PERFO RMANCE AND RELI ABI LITY DO N OT PRE SENT THE AMPL IFI ER WITH A SP EAK ER LOAD OF LESS THAN 2 OHMS OR ANY COMB INATIO N OF SPEAKERS THAT TOGETHER ARE L ESS THAN 2 OH MS!
USIN G ONE SPEAKER, IT MUST BE R AT E D AT 4 O R M O R E O H M S .
USIN G TWO SPEA KERS, THEY M UST RATED E ACH AT 4 OR MORE OHM S.
USING THREE SPEAKERS, THEY MUST BE RATED EAC H AT 8 OR MORE O HMS .
POUR ASSURER LA FIA BILETE ET OBTE NIT UNE PERFO RMANC E OPTI MALE, NES OUMET TE JAMAIS L’AMP LIFICATEUR A UNE CHA RGE D’IM PEDANCE TOTALE INFER IEURE A 2 OHMS, NI AVEC UN H.P. N EN COMB INAISON D ES H.P.
AVEC UN H.P., IL FAUT UNE CHA RGE D’IM PEDANCE MINIMU M DE 2 OHMS.
AVEC DEUX H.P., FAUT POUR CH AOUN UNE CH ARGE D’IM PEDAN CE MINIMU M DE 4 OHMS.
AVEC TROIS H.P., FAUT POUR CHA OUN UNE CH URGE D’IM PEDAN CE MINIMU M DE 8 OHMS.
Important Precautions
To reduce the risk of electrical shock or f ire, do not expose this unit rain or moisture
• Do not spill water or other liquids into or on to your unit
• Do not attempt to operate this unit if the power cord has been frayed or broken
• Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and f re in case of an internal short
• Disconnect main power before making any type of connection
• Do not remove the cover under any conditions. There are no user serviceable parts inside
• Never plug this unit in to a dimmer pack
Always be sure to mount this unit in an area that will allow proper Always be sure to mount this unit in an ar ea that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall
• Do not attempt to operate this unit, if it becomes damaged
This unit is intended for indoor use only, use of this product out­ doors voids all warranties
• During long periods of non-use, disconnect the unit’s main power
Always mount this unit in a safe and stable manner Always mount this unit in a safe and stable manner
• Power cords should be routed so they are not likely to be walked on, pinched by items placed upon or against them.
• Cleaning -The outside of the unit should be wipe down with a soft cloth and mild cleaner when needed.
• Heat -The amplifier should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
The fixture should be serviced by qualified service personnel when: The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. A. The power-supply cor d or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the unit. C. The appliance has been exposed to rain or water. D. The fixture does not appear to operate normally or exhibits a marked change in performance.
Introduction
Installation: This amplifier is designed to mount into a standard 19” rack. The front panel provides four holes used to screw the unit into a rack. The unit also provides a way to rear mount the unit into a rack for added security. Rear mounting the unit is especially recom­mended if the unit is to mounted into a mobile rack.
page 4
Introdu cti on: Congratu lat ions and t han k you f or p urchasing an UNiKA’s A s eries amplifier. Th is am pli fier is a repre sen tat ion o f UNiKA’s c ont inuing commit men t to produce the
amplifiers are de sig ned to pr ovide a big impa ct in sou nd reprodu cti on. Please read and und erstand this man ual completely befo re attempt ing t o operate yo ur new ampli fie r. Th is booklet c ont ains important i nformation c oncerning th e proper a nd s afe opera tio n of your new ampl ifi er.
best and highe st
quality au dio products at an aff ord able price . These
Un Every A series amplifier has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for any damage and be sure all accessories necessary to operate the system have arrived intact. In the event damage has been found or parts are missing, please contact your dealer for further instructions.
acking:
FRONT PANEL
1. Power Switch - This switch controls the units main power.
This is used to activate the channels built-in limiter. The limiter reduces the average output level when the signal begins to distort, this process is designed to reduce distortion and protect the speakers. See limiter page 13.
3. Channel 1 Clip Indicator - This red LED will begin to f lash when
channel one begins to overload (clip). At this point channel one will be­gin to distort. Under heavy clipping activity lower the channel one gain control to reduce the risk of damage to your speakers and amplifier. This LED may glow when the unit has been turned off, this is normal.
4. Channel 1 Protect Indicator - The red Protect LED will begin to
glow when the channel goes into protect mode. When the channel goes into protect mode all output for that channel will turn off. This is to pro­tect any speakers connected to the channel.
5. Power Indicator - This blue LED will glow when main power is ap-
plied to the unit. This light may continue to glow brief y after main power has been turned off, this is normal.
6. Channel 2 Protect Indicator - The red Protect LED will begin to
glow when the channel goes into protect mode. When the channel goes into protect mode all output for that channel will turn off. This is to pro­tect any speakers connected to the channel.
7. Channel 2 Clip Indicator - This red LED will begin to f lash when
channel two begins to overload (clip). At this point channel one will be­gin to distort. Under heavy clipping activity lower the channel one gain control to reduce the risk of damage to your speakers and amplifier. This LED may glow when the unit has been turned off, this is normal.
8. Channel 2 Limiter Switch ( ) -A-800 & A-1300 Only This is used
to activate the channels built-in limiter. The limiter reduces the average output level when the signal begins to distort, this process is designed to reduce distortion and protect the speakers. See limiter page 13.
9. Cooling Vents - These vents are used for proper cooling. Never
block these vents and keep them clean at all times.
10. Channel 1 Gain Control - This rotary knob is used to control the
output signal of channel one. Turning the knob in a clockwise direction will increase signal output.
11. Channel 1 Signal Indicators - These green and yellow LED’s will
glow according to the average signal output.
12. Channel 2 Signal Indicators - These green and yellow LED’s will
glow according to the average signal output.
13. Channel 2 Gain Control - This rotary knob is used to control the
output signal of channel two. Turning the knob in a clockwise direction will increase signal output.
Diagram 1
CONTROLS AND FUNCTIONS
10
2 7
3
9
1 4 5 6 8
9131211
POW ER
ON
OFF
LIMI TER
ON
0
SIGNA L
-20dB
-10dB
CLIP
PROTE CT
POWER
PROFESSIONAL POWER AMPLIFIER
LIMI TER
ON
0
10
page 5
A-800
UNiKA
2. Channel 1 Limiter Switch (A-800 & A-1300 Only) -
Loading...
+ 10 hidden pages