Unigreen RV-GDC, Super Spalliera, Ventagli, AIRDROP P Series, ELETTRA P Series Use And Maintenance Manual

...
04/2010
USE AND MAINTENANCE MANUAL
MISTBLOWERS AIRDROP - MFC
®
MOUNTED MISTBLOWERS
serie AIRDROP P - ELETTRA P - MFC P:
Ventagli - Minibar - Super Spalliera - RV-GDC
GB
2 unigreen
Summary
1 USING AND KEEPING THE USE AND MAINTENANCE MANUAL ....................... 4
1.1 COMPOSITION OF THE MANUAL ...................................................................................... 4
1.2 GUARANTEE ....................................................................................................................... 4
1.3 PRODUCT RESPONSIBILITY ............................................................................................. 4
1.4 WARNING SIGNS IN THE MANUAL AND ON THE MACHINE ............................................ 4
2 SAFETY REGULATIONS AND RESIDUAL RISKS ................................................ 5
2.1 INTENDED USE .................................................................................................................. 6
2.2 PROHIBITED USE ...............................................................................................................6
2.3 USING CHEMICAL PRODUCTS ......................................................................................... 6
2.3.1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS ............................................. 6
2.4 RECOMMENDATIONS ........................................................................................................ 6
2.4.1 TAKING PRECAUTIONS AGAINST FIRE HAZARDS .......................................................... 7
2.5 WEATHER CONDITIONS .................................................................................................... 7
2.6 MACHINES DESIGNED TO BE USED ONLY WITH CLEAN WATER................................... 7
2.7 DRIVING ON THE ROAD ..................................................................................................... 7
3 CHARACTERISTICS AND SPECIFICATIONS........................................................ 7
3.1 TABLES OF FITTINGS ALLOWED ...................................................................................... 7
3.2 NOISE LEVEL OF THE MACHINE....................................................................................... 8
3.3 STANDARDS OF REFERENCE: .......................................................................................... 8
4 INSTRUCTIONS ...................................................................................................... 8
4.1 DESCRIPTION OF THE MACHINE ..................................................................................... 8
4.1.1 WORK STATIONS ................................................................................................................ 8
4.1.2 HAND WASHING TANKS ..................................................................................................... 9
4.2 PRELIMINARY CHECKS ..................................................................................................... 9
4.3 TRANSPORTING AND MOVING THE MACHINE................................................................ 9
4.3.1 TOWED ATOMISERS .......................................................................................................... 9
4.4 TRACTOR COUPLING ...................................................................................................... 10
4.4.1 THREE-POINT COUPLING ............................................................................................... 10
4.4.5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS ..................................................... 10
4.5 CARDAN SHAFT ............................................................................................................... 11
4.6 PUMP ................................................................................................................................ 11
4.7 SUCTION FILTER .............................................................................................................. 11
4.8 PRESSURE REGULATOR................................................................................................. 12
4.8.1 COMPONENTS OF THE PRESSURE REGULATOR ........................................................ 12
4.8.2 GENERAL INSTRUCTIONS .............................................................................................. 12
4.8.3 DELIVERY FILTERS (ONLY EQUIPPED MODELS) .......................................................... 13
4.9 AUXILIARIES TAPS BLOCK .............................................................................................. 13
4.10 FILLING THE TANK............................................................................................................14
4.11 TEST WITH CLEAN WATER .............................................................................................. 14
4.12 MIXING .............................................................................................................................. 15
4.12.1 MANUAL PREMIXING ....................................................................................................... 15
4.12.2 PREMIXER ON COVER (OPTIONAL): .............................................................................. 15
4.12.2 PREMIXER ON COVER (OPTIONAL): .............................................................................. 15
4.12.4 COVER WASHER FOR CHEMICAL CONTAINERS .......................................................... 15
4.13 WASHING THE ATOMISER ............................................................................................... 16
4.13.1 CIRCUIT WASHER AND TANK WASHER .......................................................................... 16
5 BLOWER GROUP ................................................................................................. 17
5.1 MULTIPLIER - FAN UNIT ................................................................................................... 17
5.5 CLUTCH ............................................................................................................................ 17
5.3 DISTRIBUTOR ACCESSORIES ........................................................................................ 18
5.3.1 VENTAGLI (FANS) CANOPY, AND ESPALIER DISTRIBUTORS ....................................... 18
5.3.2 MINIBAR FOR ESPALIER .................................................................................................. 18
5.3.2 SUPER SPALLIERA FOR ESPALIER ................................................................................ 18
5.3.3 RV BOOM FOR GDC......................................................................................................... 19
5.4 HYDRAULICS .................................................................................................................... 19
5.4.1 OIL FEED FROM TRACTOR ............................................................................................. 19
6 SPRAYING ............................................................................................................. 20
6.1 DESCRIPTION OF THE DIFFUSERS............................................................................... 20
6.1.1 NON-DRIP VALVE .............................................................................................................. 20
6.2 DESCRIPTION OF THE MFC® NOZZLES ........................................................................ 20
6.3 MIXTURE CONCENTRATION ........................................................................................... 20
5 MISTBLOWER CALIBRATION ........................................................................................... 20
unigreen 3
6.4.1 BATCHING TAPS (SEE PICTURE 20) ............................................................................... 21
6.4.2 CALIBRATED PLATES CP ................................................................................................. 22
7 HAND LANCES ..................................................................................................... 22
8 MAINTENANCE ..................................................................................................... 22
8.1 PROGRAMMED MAINTENANCE ...................................................................................... 22
8.2 ROUTINE MAINTENANCE ................................................................................................ 22
8.2.1 CLEANING THE NOZZLES ............................................................................................... 23
8.2.2 LUBRICATION ................................................................................................................... 23
8.2.3 MULTIPLIER LUBRICATION .............................................................................................. 23
8.3 EXTRAORDINARY MAINTENANCE .................................................................................. 23
23
8.4 REPAIRS ............................................................................................................................ 23
23
8.5 STORAGE IN A WAREHOUSE AND TRANSPORTATION................................................. 23
8.6 PUTTING BACK INTO SERVICE AFTER WINTER LAYUP ............................................... 24
8.7 DEMOLITION AND DISPOSAL ......................................................................................... 24
8.7.1 MATERIALS FOR DEMOLITION ....................................................................................... 24
8.7.2 INDICATIONS FOR A SUITABLE TREATMENT OF WASTE ............................................. 24
8.7.3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE (EEAW) .................................... 24
TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.CANOPY .... 25
TABLES FOR CALIBRATING AIRDROP 2 VENT. (FANS) ESPALIER TOPDIF. ..26 TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.ESPALIER ... 26
TABLES FOR CALIBRATING AIRDROP MINIBAR ............................................................. 27
TABLES FOR CALIBRATING AIRDROP RV-GDC ............................................................... 28
TABLES FOR CALIBRATING AIRDROP SUPER SPALLIERA ........................................... 28
TABLE 3 TABLES OF DELIVERY CALIBRATED PLATE................................................... 29
TABLE 4-5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES ......................... 29
TABLE 7 TABLE OF PROGRAMMED MAINTENANCE ...................................................... 30
TAB.18A ALLOWED FITTINGS ............................................................................................ 31
4 unigreen
Thank you for having chosen UNIGREEN. The product you purchased has been designed and built with the greatest attention to the safety of the operator and the environment, nevertheless there are still some residual risks due to the nature of the product used. For this reason we recommend reading all of this manual to avoid making mistakes in the first period of use and to get the most out of the working life of the sprayer in time, doing the programmed maintenance at regular intervals.
1 USING AND KEEPING THE USE AND MAINTENANCE MANUAL
The manual is an integral part of the machine and should be kept in a safe place where it can be reached easily for consultation.
1.1 COMPOSITION OF THE MANUAL
This manual consists of various parts to make it easier to consult by subject and to avoid repetitions; the following are part of the manual:
a) pump handbook b) pressure regulator handbook (manual or electric) c) spraying computer handbook (if fitted) d) optional accessories handbooks (marker, premix, cardan shaft, etc.)
UNIGREEN reserves the right to make changes to the manual without prior warning and the normal printing cycles may vary slightly.
1.2 GUARANTEE
The enclosed card indicates the conditions of the UNIGREEN guarantee. The UNIGREEN guarantee covers the repair or replacement of parts considered manufacturing flaws, according to the unquestionable judgement of UNIGREEN, only after the authorised agent for that zone has verified the fault. Ambit of the guarantee The guarantee doesn’t cover cases of normal wear, negligent use, poor maintenance and/or improper use.
The following materials subject to normal wear are not covered by the guarantee: gaskets and seals, diaphragms, seal rings, tubes and pipes,
nozzles, pressure gauges, oil, tyres, friction material of the clutches. Evident cases of negligence include: work speed over that indicated in the spraying tables in the handbook (or too high for the conditions of the terrain), use of herbicide booms without an auto-levelling system or with the auto­levelling system blocked, power-takeoff speed over 540 rpm. Mounted mistblowers: activation of the three-point elevator with cardan shaft en­gaged and power-takeoff operational. And anything else indicated in the present Use and Maintenance Manual. Maintenance: The guarantee is void if the maintenance indicated in the tables in this manual isn’t respected, regarding the period and deadline of the interventions, washing the machine and the circuit at the end of the treatment. Improper use: The use the UNIGREEN machines are designed for is indicated in this manual, any other use is forbidden and makes the guarantee void.
1.3 PRODUCT RESPONSIBILITY
UNIGREEN spa is not responsible if: a) During the working life of the machine the normal maintenance operations aren’t performed and documented as indicated in this handbook, in the enclosed handbooks of the pumps-motors-regulators-etc. and in any case as is customary for the normal maintenance of mechanical machinery. b) The machine is equipped with non original accessories or components or parts that aren’t acknowledged by UNIGREEN as their own. c) The machine is equipped with original accessories or components that are unsuitable in the measurements, weight or version for the same. Please consult the page of available and recommended fittings.
d) Not following the instructions in the manual whether totally or partially. e) Modifications made to the machine that haven’t been authorised by
UNIGREEN.
1.4 WARNING SIGNS IN THE MANUAL AND ON THE MACHINE
Below you will find all of the pictograms on the machine (see FIG.1 for their position), in order to illustrate the warnings, the prohibitions and the correct method of use. The operations that require particular attention are shown in the images beside the text.
Composite handbook, consult the specific files on the various components
unigreen 5
2 SAFETY REGULATIONS AND RESIDUAL RISKS
In relation to safety, the following terms will be used: Dangerous zones: any zone inside and/or near the machine where the presence of a person exposed constitutes a risk for the safety and health of the same person. Person exposed: any person who has their body or any part of their body in a dangerous zone.
Before starting the machine, the operator must check for any visible faults in the safety devices and the machine itself. Never start the machine until you have told anyone in the range of action of the machine to move away and they have done so. The protective devices must not be removed or disabled when the machine is running. It is obligatory to keep all the plates with danger and safety signs in perfect conditions. If they get damaged or deteriorate, replace them in good time. Replace parts believed to be faulty with others indicated by UNIGREEN. NEVER try makeshift or hazardous solutions. Don’t wear clothes, jewellery, accessories, or anything else that can get caught in the moving machine members. Pay the greatest attention to all the warning and danger signs on the machine. Don’t use the machine for any other purpose other than that indicated in the manual. The machine has been designed and built with the appropriate devices to guarantee the safety of the user. In any case there are some residual risks associated with the improper use of the machine by the operator; for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine (see previous pictograms).
2019 2221
2
1
6
3
4 5
8
7
12
9
10 11
14
13
18
15
16 17
23
da 1 a 18
19+20
23
FIG.1
21+22
11+12
Key to the symbols
1- Read the Use and Maintenance manual 2- Stop the machine and read the manual before every intervention 3- Don’t lubricate while running 4- Don’t drink 5- Don’t dispose of residue liquids in the environment 6- No smoking 7- Danger, risk or injury, don’t get near the machine until the moving machine members have stopped 8- Danger of crushing, don’t get your hands near the moving mechanical machine members 9- Danger, risk or injury caused by fluids under pressure 10- Don’t climb on the machine during work or transfers 11- Don’t climb on the tank 12- Don’t enter in the tank 13- Wearing earmuffs is obligatory 14- Wearing a face mask is obligatory 15- Wearing safety footwear is obligatory 16- Wearing protective gloves is obligatory 17- Wearing protective overalls is obligatory 18- Use a working pressure under that indicated in red on the manometer. 19- Don’t get your hands near the moving cardan shaft 20- Make sure power-takeoff of the tractor turns in the right direction and runs at the right speed. 21- Don’t remove the protecting device with fan moving. 22- Material shooting off the machine, stand at a safe distance. 23- Don’t stand between the machine and the tractor.
INDICATIVE POSITION OF THE WARNING SIGNS ON THE MISTBLOWERS NB: the position may vary on the basis of the characteristics of the model.
6 unigreen
2.1 INTENDED USE
The sprayer in this series is built for agricultural use. The materials used are resistant to normal chemical products used in agricultural spraying (or herbicides) at the time of construction. Any other use is not allowed and the manufacturer is not responsible for any damage caused by aggressive, dense or sticky chemicals. THE USE OF THE MACHINE BY PERSONS UNDER 18 YEARS OF AGE IS STRICTLY FORBIDDEN The use of liquid fertilizers in suspension is not allowed, while the use of the same in a solution is possible if requested when the machine is ordered from Unigreen and in any case changing some of the parts described in the handbooks of the regulator, such as the manometer (stainless steel), the nozzles (large diameter ceramic) and eliminating the fine mesh filters to prevent blockages.
2.2 PROHIBITED USE
Using the machine with the following products is strictly forbidden: = Paints of any kind and type = Solvents or thinners for paints of any kind and type = Combustibles or lubricants of any kind and type = LPG or gas of any kind and type = Flammable liquids of any kind and type = Liquid foodstuffs, whether for animals or humans = Liquids containing granules or consistent solids = Mixtures of various incompatible chemical products = Liquid fertilizer or manure in suspension with lumps and/or that is
particularly dense = Liquids with a temperature of over 40°C = Any products that aren’t suitable for the specific use of the machine.
2.3 USING CHEMICAL PRODUCTS
All pesticides or herbicides can be dangerous to humans and the environment if used erroneously or inadvertently. Therefore we recommend that only suitably trained persons should use these products (license) and in any case only after having carefully read the instructions on the container.
2.3.1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS
Some recommendations for avoiding damage and accidents:
= Keep the machine in a suitable, protected place with no access for children or strangers = Handle the products with care, wearing rubber acid-proof gloves, goggles- face masks or filtering helmets, overalls made of water-repellent fabrics or TIVEK and boots made of rubber or similar materials. = If chemical products or mixtures of product come into contact with the eyes or are swallowed consult a doctor immediately, taking the label of the product with you. = Wash all clothes that come into contact with the chemical, whether diluted or undiluted, thoroughly before using them again. = Don’t smoke, drink or eat when preparing or spraying the mix or near or in the fields treated. = DON’T ENTER THE TANK: the residues of a chemical product can cause poisoning and suffocation. = When spraying, respect safe distances from residential areas, water courses, roads, sports centres and public parks or paths. = Thoroughly wash the containers of plant protection products using the relevant accessories, rinsing several times with clean water. The liquids used for washing can be used for treatment. = Collect the washed containers and send them to the relevant collection centres. Never dispose of them in the environment and don’t use them again for any other purpose. It is good practice to knock a hole in the bottom of the tins so they can’t be used again. = When you have finished spraying, wash the sprayer thoroughly, diluting the residues with a quantity of water at least 10 times that of the residues, spraying the resulting mix over the treated field.
2.4 RECOMMENDATIONS a) Refer to the present handbook for the use and maintenance of the
frame, tank, auto-levelling systems, elevators, mechanical and hydraulic herbicide booms, spray booms and hose reels.
unigreen 7
Refer to the enclosed handbooks for the use and maintenance of the pump and pressure regulator and any accessories or motors. b) Please contact the agent in your zone, the nearest authorised workshop or UNIGREEN S.p.A. directly for any repairs the user feels they aren’t capable of performing alone. (see point 8.4) c) Due to the complexity of the equipment and the variety of technologies used (mechanical, hydraulic, oil-pressure and electrotechnical) operators must not dismantle or modify the equipment. All of the relevant operations must be performed by specialised personnel, authorised by UNIGREEN S.p.A.
2.4.1 TAKING PRECAUTIONS AGAINST FIRE HAZARDS
Don’t use naked flames or heat sources near the machines. The mistblowers are made with many materials that derive from petroleum: tanks, tubes, pipes and hoses, wheels and plastic parts; furthermore the presence of oils of various nature and residues of chemical products make them potentially flammable.
2.5 WEATHER CONDITIONS
We recommend spraying in the early hours of the morning or late in the afternoon, avoiding the hottest time of day. Never do any spraying if it’s raining or rain is forecast. Don’t spray in strong wind or in any case, in winds above 3/5 m/second. If you have to spray in windy conditions, use relatively low pressures to obtain quite large drops that are less sensitive to drifting (being heavier the wind has less effect). There are also special anti-drift nozzles available from UNIGREEN S.p.A.; for information, please contact our offices.
2.6 MACHINES DESIGNED TO BE USED ONLY WITH CLEAN WATER
There are versions of the machines designed only to be used with a hose reel for washing with cold clean water. These machines cannot be used with chemical products as they don’t have some of the devices or accessories that are needed to use these products safely. These machines are identified by the word “washing” on the CE plate.
2.7 DRIVING ON THE ROAD
The towed mistblowers are not specifically designed for road use. Nevertheless, many models are also available in the version homologated for road traffic with the tank empty. You should check with your local reseller on the correct couplings to use and use tractors that meet the regulations in force.
3 CHARACTERISTICS AND SPECIFICATIONS
This handbook is valid for mounted and towed mistblowers with axial fans for phytosanitary treatment in orchards and vineyards, in any case for arboreal cultivation in rows of varying nature and type. It is also valid for cannon mistblowers for the phytosanitary treatment of tall plants and forest trees such as poplars or similar. The axial mistblowers produce a mixed spray, breaking the drops with the pressure and the speed of the air produced by the fan. These mistblowers produced by UNIGREEN SPA are identified by the CE plate (FIG. 2) bearing one of the marks indicated in the tables of the allowed fittings (see the following paragraph).
3.1 TABLES OF FITTINGS ALLOWED
Table N° 18a let you identify the version of your machine indicating the basic equipment and all the possible fittings available (optional). You can also find the other fittings allowed or other versions to meet your requirements in the future.
THE EQUIPMENT DEFINED IN THE TABLES OF THIS HANDBOOK (TAB: 18a, page 31) SHOULD BE CONSIDERED BINDING FOR THE VALIDITY OF THE DECLARATION OF CONFORMITY. Other fittings or setups of basic components and/or optionals should be considered unsafe and therefore are not covered by the guarantee and aren’t UNIGREEN’s responsibility. The same goes for fittings realised with components or accessories that aren’t original UNIGREEN parts. UNIGREEN accessories can easily be identified by the label with the yellow background “ORIGINAL UNIGREEN ACCESSORY”
TYPE : .......................................................................
code: ........................................ N˚ ...........................
massa a vuoto: ..........................Kg. max press. : ........... bar
net mass
massa totale ammessa: .............................. Kg.
total mass
via Rinaldi, 105 - Reggio Emilia ITALIA
ANNO YEAR
20 .......
made in
Italy
FIG.2
8 unigreen
3.2 NOISE LEVEL OF THE MACHINE
Use earmuffs to protect your ears when using the machine, below you will find the data on the maximum noise levels during work.
Atomisers with centrifugal fan rotor (Airdrop)
ACOUSTIC POWER LEVEL emitted by the machine: 123,8 dBA in 2nd gear ACOUSTIC POWER LEVEL AT THE OPERATOR’S POSITION emitted by the machine:
103,2 dBA in 2nd gear
Readings taken in accordance with the following standards: Machines Directive 2006/42/CE Legislative Decree D.Lgs. n°292 of the 4th of September 2002 concerning the environmental acoustic emission of machines and equipment for use outdoors. UNI EN ISO 4254-1; 2006
3.3 STANDARDS OF REFERENCE:
- MACHINES DIRECTIVE 2006/42/CE
- D.Lsg. 81/08 Unique text for safety and hygiene in working places
-UNI EN ISO 12100-1/Apr.2005 : Machinery safety - Fundamental concepts, general design principles - Part 1: basic terminology, methodology
-UNI EN ISO 12100-2/Apr.2005 : Machinery safety - Fundamental concepts, general design principles - Part 2: Technical principles
-UNI EN ISO 13857: May 2008 : Machinery safety, safe distances to avoid reaching hazardous areas with upper limbs.
-UNI EN 349/November 2008: Machinery safety, minimum spaces to prevent crushing of body parts
-UNI EN 907/Nov.1998: Agricultural and forestry machinery - Sprayers and spreaders of liquid fertilizers - Safety.
-UNI EN ISO 13849-1: February 2007: Machinery safety - Fundamental concepts, general design principles
-UNI EN 982/January 2007: Machinery safety. Safety requisites relevant to systems and their components for hydraulic and pneumatic transmissions. Hydraulics.
-UNI EN ISO 4254-1/June 2006: Agricultural machines - Safety - Part 1: General requisites
-ISO 11684/1995: Pictograms - general principles.
4 INSTRUCTIONS
To use the machine the personnel must be suitably trained on the basis of the regulations in force on safety and hygiene at work. THE USE OF THE MACHINE FOR PERSONS UNDER 18 YEARS OF AGE IS STRICTLY FORBIDDEN
4.1 DESCRIPTION OF THE MACHINE
The mistblowers consist of a structural steel frame and a polyester tank reinforced with fibreglass or high-density polyethylene. The frame is hot-galvanised. The tank is easy to empty and this makes it possible to use the machine even on hillsides. The pumps are generally diaphragm pumps but in some cases they are fitted with pistons. The accessories for completing the fitting, non-drip jets and ceramic nozzles make the UNIGREEN mistblower a highly qualified and efficient piece of equipment.
4.1.1 WORK STATIONS
The use of this machine does not envisage an operator standing constantly near the same, the operator normally sits in the cab of the tractor. During calibration and maintenance operations the operator will be working near the machine at ground level (for all the calibration and maintenance operations refer to the relevant chapters). In case of operations that request the entry to parts of the machines located at 1,5 mt. height ,it is advised to use a ladder at rule; the ladder shall be positioned steady on a flat ground not yielding and with the machine at a standstill and braked. In some special models with controls above 1.5 metres there is a platform to make these operations easier. This platform must only be used with the machine stopped.
unigreen 9
4.1.2 HAND WASHING TANKS
The mistblowers are supplied with an auxiliary hand-washing tank with clean water and a hand tap. This tank must always be supplied with water and the inside must be clean so you can wash any parts of the body that come into contact with the chemical product used. Never drink the liquid inside.
4.2 PRELIMINARY CHECKS
When you receive the machine, check that it is complete and no parts are missing. If there are any damaged parts, inform your local reseller or UNIGREEN directly in good time. When the machine is delivered, make sure you ask:
a) that the machine is delivered with all of its parts fitted and that the fitting meets the requisites in table N° 18a (page 31). This procedure is necessary because for reasons of space during transportation the machine is often delivered partially dismantled.
b) that it is tested in your presence in particular checking: = that the suction filter and the inside of the tank are clean and free of work
residues. = that the connections are made correctly following the basic layout (FIG. N° 16, page 16). = that the hose clips and all the unions and connections are tightened properly. = that all of the protective covers are fitted solidly to the machine, in particular the protective cover of the power-takeoff of the pump. = that the multiplier is sufficiently supplied with lubricant oil. = that the zone where the fan turns hasn’t been bent by knocks during transportation.
4.3 TRANSPORTING AND MOVING THE MACHINE
Every time you have to lift the machine, before starting the operation, always make sure the lifting gear and the relevant tools and equipment (cables, hooks, etc..) are suitable for lifting the load and check the stability of the same.
It is forbidden to unhook and move the machine with the tank full.
The dry weight of the machine at the maximum level of fitting and with all the accessories allowed is stamped on the nameplate (FIG.2); use slings and lifting gear with a adequate load-bearing capacity (FIG.3). Never lift or move the mistblowers by hand if there is liquid in the tank. The machine will weigh more and the movement of the liquid can change the centre of gravity causing uncontrolled movements. We recommend using slings as shown in the figure, the lifting points to use on the machine are indicated with the relevant symbol. Don’t lift the machine with the forks of a forklift truck because the machine can tip over due to the overhanging weight of the blower group. Don’t pass or stand under the machine when it is being lifted.
4.3.1 TOWED ATOMISERS
PARKING Don’t stand the atomiser on unstable ground or steep slopes, the machine is designed to be parked safely on compact ground with a slope of up to 8.5°
MOVING To lift the machine, follow the instructions above.
FIG.3
This symbol identifies the clean water tank on the machine used to wash your hands
This symbol identifies the coupling points of the machine
Only move and lift the machine with the tank empty
10 unigreen
4.4 TRACTOR COUPLING
The tractor must have 1”3/8 ASAE DIN 9611/A power-takeoff that runs at 550 rpm. It must have a 3-point elevator suitable for safely supporting the weight of the atomiser. Check this by consulting the table of allowed fittings N° 18a (pages 31).
WARNING: make sure there are no persons or things near the atomiser before starting the machine and while you are using it.
4.4.1 THREE-POINT COUPLING
a) We recommend carefully checking that the tractor is suitable for supporting the weight of the fully loaded sprayer safely. The total weight of the sprayer with all of its accessories and fittings is indicated on the nameplate in FIG. 2 and also (in the version with the maximum fittings allowed) in tables N° 18a (pages 31).
For verification use the formula shown here.
Non-observance can result in a very dangerous situation as the tractor will lose steering sensitivity and can tip over when driving uphill or over bumps. b) Check the diameter of the elevator coupling pins. If necessary position the double diameter pins correctly; there are also appropriate adapter bushes available. c) Adjust the length of the third point tie-rod correctly so the sprayer is perfectly vertical in normal working position. d) Check for the presence of the safety pins that stop the arms of the tractor jumping off the connecting pins.
4.4.5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS
Machines that need a hydraulic connection to drive the movements of the cannon are equipped with 1/2", “Push-Pull”, quick-fit male couplings. You can connect the pipes by simply pushing them in, making sure you:
- do so only with the engine turned off;
- lower any tools connected to the elevator of the tractor;
- carefully clean the two parts that will be coupled
Warning: the hydraulic cylinders used are the “Double Effect” type. Consult the use and maintenance manual of the tractor.
Tractor coupling
FIG.4
M x s < 0,2 T x i + Z x (d + i)
i = tractor wheelbase
d = distance from the front axis and the ballast
s = overhang from the rear axle of the
operating machine
T = mass of the tractor + operator (75kg)
Z = ballast mass
M = sprayer mass
unigreen 11
4.5 CARDAN SHAFT
In some models this is supplied on request. The cardan shaft must bear the CE mark. It must always have its own instructions that must be followed scrupulously and it should come with a cover bearing the mark, integrated in every part. You should have previously checked the length to avoid:
= if it is too long, DANGEROUS THRUST ON THE PUMP SHAFT = if too short, the POSSIBILITY OF DANGEROUS BREAKAGES
THE MINIMUM OVERLAP OF THE TWO TELESCOPIC TUBES MUST NEVER BE LESS THAN 1/3 OF THE LENGTH OF THE TUBES.
The power that can be transmitted by the cardan shaft must be at least equal to that required to run the mistblower. These power ratings are indicated in tables N° 18a (page 31).
a) Hook any safety chains to solid anchor points b) Check that the button or ringnut “E” (FIG. 6) is correctly engaged and blocked both on the pump side and on the tractor side.
c) Don’t exceed an inclination of 30° in any direction for any reason d) With the machine stopped, periodically grease the spiders and the pipes,
keeping the connecting zone particularly clean. e) Avoid letting the end of the cardan shaft come into contact with the ground with the machine stopped; use the relevant support on some versions for this, if your machine has no support, hook the external safety chain to a part of the frame of the machine (ex. control unit support). f) For towed mistblowers with a steering drawbar, be very careful not to lift the arms of the elevator too high to prevent the cardan shaft touching parts of the drawbar. l) For towed mistblowers, avoid very tight steering circles with the cardan shaft turning (max 30°) as this could damage both the cardan shaft and the feet of the pump (FIG. 7).
NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING:
- TRACTOR POWER-TAKEOFF PROTECTIVE COVER
- CARDAN SHAFT PROTECTIVE COVER
- FIXED PROTECTIVE COVER ON THE PUMP SHAFT
4.6 PUMP
When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the manufacturer. The pump can be identified by the ratings plate on the same; the main data on the pressure and delivery are easy to find on this plate. Normally the pumps mustn’t exceed 550 RPM; a higher speed won’t improve performance but there is a risk of compromising the life and safety of the pump. There is a safety valve on the pump, calibrated to prevent overpressure. Don’t tamper with this valve for any reason and don’t block or obstruct the pipes connected to it in any way.
4.7 SUCTION FILTER
The sprayer is fitted with a suction filter with filter cartridges that have roughly a 50-gauge mesh, which is equivalent to a hole of 0.4 at 0.35 mm. An efficient filter lets the sprayer work properly. You should periodically check that the filter cartridge is clean, this check should be done more often if there are impurities in the liquid. To inspect the filter cartridge wear rubber acid-proof gloves as the liquid in the filter can come into contact with your hands when you open the filter. Don’t perform this operation with the pump running as the depression produced blocks the cover preventing the removal. Before removing the cover of the filter, make sure that the same is isolated from the tubing by unscrewing the relevant rear valve (FIG. N°8) or on the 3-way deviator (FIG. N° 10, page 14). After washing the cartridge, reassemble the cover making sure you connect the same to the circuit again, using the valves described above in the opposite order. WARNING!: Don’t disperse the washing residues in the environment!!
FIG. 7
FIG. 6
FIG. 8
Valve
Filter
12 unigreen
4.8 PRESSURE REGULATOR
To use the pressure regulator, follow the instructions in the enclosed hand­book scrupulously. The pressure regulator controls all of the most important spraying functions, the thorough knowledge of its functions makes work easier and more precise. The working pressure and the maximum pressure of the sprayer are deter­mined by the pressure regulator which also protects the circuit from overpressure in any work conditions. (In serious but very rare cases, if the connecting pipes get blocked the pressure relief valve lets the pressure off) In some setups there may be a pump that can reach a pressure of 50 bar controlled by a regulator designed for 20 bar. In this case the maximum pressure that can be reached is 20 bar. The regulators can be manual, mounted on the sprayer or at a distance to make the controls easier to use; or electrical with a control panel in the cabin. There are also regulator versions with mechanical remote controls with a cable. If the tractor has a waterproof cabin the use of electrical controls is obligatory.
4.8.1 COMPONENTS OF THE PRESSURE REGULATOR
Below you will find the indications for the main models fitted on Unigreen products.
A main ON-OFF command: “open” lets the fluid flow into the circuit in use; “closed” empties the tank. B maximum pressure valve: adjusted by hand with the relevant knob (drains the excess liquid when the set pressure is reached). C jets section tap: opens the corresponding jet boom or drains to the compensation regulator (G).
D auxiliary tap: can be used for various accessories (it is always manual). E volumetric pressure valve (proportional):
(when present) it regulates the spraying pressure. The valve automatically compensates variations in speed (within the scope of the same gear ratio), keeping the quantity of liquid supplied per surface unit (litres/hectare) unchanged.
F self-cleaning filter: filters the delivery liquid. G compensation regulators: suitably regulated, these make it possible to
keep the pressure constant when one or more sections of jets is closed, they don’t influence treatments with the boom fully open. H manometer: indicates the working pressure.
Connections:
R1 supply union R2 drain union R3 volumetric drain union R4 jets section delivery union R5 auxiliary delivery union
Control box for GCP ELETTRICO electrical regulators I1 main control valve switch I2 volumetric pressure valve switch (proportional) I3 jets section valves switches
4.8.2 GENERAL INSTRUCTIONS
When using the pressure regulator, scrupulously observe the instructions in the enclosed handbook, below you will find generic indications for the major models fitted by Unigreen.
All the regulation and adjustment tests must be carried out with clean water.
Pressure regulators without a volumetric valve (GCP3-way - GRH-RVA)
Adjusting the maximum pressure valve = put main control A in the drain position (“OFF”). = loosen the hand wheel of maximum pressure valve B completely (anticlockwise). = start the pump by activating the power-takeoff of the tractor at 540rpm = open main control A (position “ON”), the manometer will be activated = open all of the section valves C (position “ON”)
Don’t use the sprayer without having consulted the enclosed handbook.
unigreen 13
= adjust maximum pressure valve B to the working value (in any case less than the safe maximum pressure the system can reach).
Pressure regulators with a volumetric valve (GCP ELETTRICO)
Adjusting the maximum pressure valve = put main control A in the drain position (“OFF”). = loosen the hand wheel of maximum pressure valve B completely (anticlockwise). = open volumetric valve E completely. = start the pump by activating the power-takeoff of the tractor at 540rpm = open main control A (position “ON”), the manometer will be activated = open the drain tap on filter F slightly (only GCP ELETTRICO). = close volumetric valve E completely. If the pressure rises over the maximum limit of the system, make sure maximum pressure valve B is open (see previous indications) = open all of the section valves C (position “ON”) = adjust maximum pressure valve B to a value over that of the working pressure (generally 10-14bar) and in any case lower than the safe maximum pressure that the system can reach.
Adjusting the volumetric pressure. = with the volumetric pressure valve E adjust the pressure to the value the treatment will be done at (the pressure is indicated on the nozzles tables on the basis of the tractor speed and litres/hectare to spray)
Warning! The working pressure must be adjusted with the volumetric valve and not with the maximum pressure valve. In the case the working pressure is too near to the calibrated pressure of the maximum pressure valve, the proportional valve may not be able to compensate the speed variations correctly.
Adjusting the compensated returns = close only one tap of section C (position “OFF”). = adjust the corresponding compensator G until you return to the pressure set previously (displayed on the manometer). = open and close the tap of section C and check that the pressure remains constant. = repeat the above operations for all the section taps. If the types of nozzles aren’t changed the regulations carried out will guarantee a constant spraying of the liquid also per treatments that are done at different working pressures. NB: if the type of nozzle is changed then the calibrating will have to be done again.
4.8.3 DELIVERY FILTERS (ONLY EQUIPPED MODELS)
This is particularly useful when using small nozzles (low volume), they are normally mounted on the jet booms and have a filter cartridge with a 40-gauge mesh (the equivalent of a 0.4 mm hole). At the end of each treatment cycle you should clean the cartridge: turn the jets to the closed position, put the command under pressure and open the tap under the filter to drain the tank for a few minutes. You should clean the cartridge by hand periodically, on the basis of the product used. Stop the pump to clean. Wear rubber gloves and the other personal protective equipment when cleaning.
4.9 AUXILIARIES TAPS BLOCK
A collector is installed (FIG. 9) in the Airdrop machines with taps for the utilities and accessories, which require a working pressure that is independent from the spraying pressure:
- Tank washing jet: see paragraph 4.13.1
- Ejector: see paragraph 4.10
- Agitators (2 independent taps): see paragraph 4.12 The taps are identified by the relevant sticker and the methods of use are described in the paragraphs indicated. The pressure is normally regulated to 30-35 bar with the relevant valve (using a yellow knob) and displayed on the manometer installed; opening the utilities makes the pressure drop.
FIG. 9
Tank rinsing
Ejector
Agitator 1
Agitator 2
14 unigreen
4.10 FILLING THE TANK
The machines for defensive crop treatments, in consideration of the safety of persons, animals and the protection of the environment, must only be filled indirectly from open water courses and only by free-falling water from the waterworks. The pipe used for filling must never come into contact with the liquid inside the tank and therefore the water must always fall over the upper edge of the filling inlet and through the filter installed on it. The tank is fitted with a transparent graduated band that shows the exact quantity of liquid inside. This reading is precise if the tank is on flat ground; the actual total capacity coincides with the highest number. All the filling systems fitted by Unigreen on their production machines or on request are antipollution and stop the liquid overflowing out of the tank.
a) FILLING WITH THE 3-WAY DEVIATOR (Fig. 10- Fig. 11). It is possible to fill the tank using the pump and the floating filter kit G (cod.1002/ 0080F) with 6 metres of rubber hose (the floating filter lets you always and only suck up clean water). = connect hose T to deviator D using the union hose adaptor supplied. = turn the lever of deviator D to the filling position. = place the other end of the hose, on which you fitted filter G, in the watering point. = start the power-takeoff leaving pressure regulator C in the draining position (you don’t have to put the pump under pressure). = the filling speed in litres/minute is equal to the delivery of pump P. = visually check the level of the liquid in the tank and after filling stop the pump and put the lever of deviator D back in the working position. = disconnect pipe T from deviator D.
b) FILLING WITH THE SUCTION FILTER (Fig. 3- Fig. 11). If the 3-way deviator isn’t fitted you can fill the tank using the coupling on the cover of the suction filter. Unscrew the rear wing nut of the filter and using a G1"1/2 threaded union, connect pipe T with the floating filter to the coupling. Also in this case the filling speed in litres/minute is equal to the delivery of the pump.
c) FILLING WITH THE ANTIPOLLUTION EJECTOR (Fig. 12) If you are filling with an antipollution hydroejector (mounted as standard on some models) then you should proceed as follows:
= put roughly 20-30 L of water in the tank and start the pump. = remove the cap of ejector E and insert filling pipe T. = place the other end of the hose, on which you fitted filter G, in the watering
point.
= open the tap that supplies the ejector (on auxiliary taps, see point 4.9). = increase the pressure until it reaches a value which is sufficient to suck up
the liquid. = visually check the level of the liquid inside the tank and after filling disconnect pipe T from the ejector, close the tap and replace the cap.
4.11 TEST WITH CLEAN WATER
It is good practice to do a test with clean water (without chemical product in the tank) before the first treatment to make sure the mistblower is working properly and to get to know the controls. For instructions on how to proceed with the treatment see the chapter SPRAYING.
FIG. 12
FIG. 10
WARNING: using the taps on the pump or in any case on the front of the machine puts the operator near the cardan shaft. Despite the presence of protections at CE rule, it is compulsory to switch off the engine and to take the key off.
FIG. 11
unigreen 15
4.12 MIXING
The active principle can be mixed using the relevant stirrers before and during the treatment. Correct mixing and stirring is the basis of the correct distribution on the crops. We recommend some useful accessories such as the premixer for powders and liquids (see the following paragraph). The machines in the Airdrop-MFC range can be equipped with 2 hydro­pneumatic agitators, supplied by the relevant taps in the auxiliaries taps block (paragraph 4.9). o mix the product in the tank run the stirrer (or ejector) for roughly 10-15 minutes at the maximum pressure available
4.12.1MANUAL PREMIXING
Dilute the active principle by hand before introducing it into the tank, (you must wear suitable protective clothing such as rubber gloves, a mask or goggles, overalls, etc.). WARNING: the indications to follow for using chemical products are indicated in paragraph 2.2.1.
4.12.2PREMIXER ON COVER (OPTIONAL):
Open the cover and pour all of the chemical powder into the filter, close the cover and open the supply tap until all of the powder has dissolved.
4.12.2PREMIXER ON COVER (OPTIONAL):
Open the cover and pour all of the chemical powder into the filter, close the cover and open the supply tap until all of the powder has dissolved.
4.12.4COVER WASHER FOR CHEMICAL CONTAINERS
The washer for chemical containers (FIG.15) is installed as standard in the hatch on the entire Airdrop-MFC range. To wash the container, proceed as follows:
-Lift the cover of the tank
-Open auxiliary tap (D) of the pressure regulator (see paragraph 4.8.1) supplying it with a pressure of under 8 bar
- Introduce the tin into the hopper, inserting the washing pipe into the tin.
-Press the tin onto the pipe until it has been washed clean.
-At the end of the operations close the tap (D) of the pressure regulator again.
FIG. 13
FIG. 15
Box washing device on cover
16 unigreen
4.13 WASHING THE ATOMISER
After every treatment, thoroughly clean the equipment, washing it with water inside and out. Dirty equipment is very dangerous for people and in particular for children. Discharging the residues of washing in the environment without taking precautions is forbidden as this pollutes water courses. Distribute the residues on the field or the crops where they won’t cause any damage. WARNING: the indications to follow for using chemical products are indicated in paragraph 2.2.1.
4.13.1CIRCUIT WASHER AND TANK WASHER
Some machine models are fitted with a circuit washer tank (FIG.17). This tank must be filled with clean water and used to rinse the entire circuit including the suction, delivery, pump, pressure regulator, jets and nozzles. Thanks to the practical rotary nozzle it also rinses the inside surfaces of the tank. NB: To completely clean the tank and the pipes of any residues of the various active principles, we recommend adding 2kg of soda to the washing liquid for every 100 L of water.
At the end of the treatment, wash the circuit and the tank.
a) Stop the diaphragm pump disengaging the power-takeoff. b) Check you have filled the circuit washer tank (C). c) Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed. d) Turn suction deviator A to the circuit washer position (H2O). e) Start the diaphragm pump by engaging the power-takeoff. f) Increase the engine speed until all of the liquid in circuit washer tank C has been sucked up. g) Turn the diaphragm pump off and turn deviator A to the work position (TANK). h) Turn the main control to ON, so there is pressure in the circuit. i) Start the diaphragm pump again and use the tank washing tap on the regulator (or on pump P) that supplies jet B. j) After a few minutes you can close the tank washing tap k) Distribute the washing residues over a portion of the field where it won’t cause damage. l) After you have finished washing, stop the diaphragm pump.
NB: at the end of the washing cycle, if there is the risk of frost, pour roughly 500 grams of normal antifreeze for auto vehicles into the tank.
FIG. 16
A
B
C
F
P
This symbol identifies the clean water tank on the machine used to wash the circuit
WARNING: using the taps on the pump or in any case on the front of the machine puts the operator near the cardan shaft. Despite the presence of protections at CE rule, it is compulsory to switch off the engine and to take the key off.
unigreen 17
5 BLOWER GROUP All the mistblowers have a high speed fan rotor. You must take great care and beware of the effects that this can provoke: such as the aspiration and projection of foreign bodies which, although of a small size, can be very dangerous especially for the eyes and face.
5.1 MULTIPLIER - FAN UNIT The Airdrop range is fitted with two versions of a Ø500 centrifugal fan: STD (max absorption 30 HP) and XP (max 50 HP). The transmission of the drive from the pump to the fan is done through a multiplier with one or two gears, plus neutral. Normally the rotation speed of the fan is 3240 RPM in first gear and 3620 RPM in second in the 2-speed multiplier (multiplied ratios 1:6 - 1:6.7) with the power takeoff running at 540 RPM. You can change from one gear to the next with the lever on the multiplier, made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side. The lever has 2 or 3 positions depending on the number of gears and the central position is neutral (to use only the pump without the fan).
WARNING: the gear change lever must only be used with the power-takeoff disengaged and the fan stopped. If it is difficult to engage, turn the cardan shaft slightly by hand to find the right position of the lever (make sure the tractor is turned off).
For the maintenance of the multiplier (see point "Multiplier Lubrication"
5.5 CLUTCH
Fans have a centrifugal type clutch that makes it possible to engage the fan rotor gradually. This prevents jerky starts, due to the inertia of the fan rotor, which can have a negative effect on the transmission. For the centrifugal clutch to work properly the speed of the power-takeoff mustn’t be less than 450 rpm, especially if you are using the first gear of the multiplier. Generally clutches with shoes/plates made of sintered material with a high coefficient of friction are fitted, on some low power models rubber clutches may be fitted.
WARNING! As there is a high multiplication ratio, the fan must be started gradually. Suddenly engaging the power-takeoff clutch (at high speed) can damage the gears.
Ø500 Nylon impeller with sinterized expansion clutch.
Ø500 fan with multiplier, 2-speed plus neutral.
WORK TEMPERATURE
Heat is generated by the friction between the various moving components and on the basis of the power transmitted. The temperature of the multiplier or disengaging box depends on the capacity to dissipate heat to the surrounding environment and therefore the surfaces involved in the heat exchange and the environmental conditions. The specifications refer to environmental conditions with a temperature between
-10° +50°C (14°C -122°F). The working temperature limit of the box is 90°C (200°F) established to prevent the ageing of the seals and guarantee a sufficient viscosity of the oil. The heat makes the air in the box expand and therefore increases the pressure inside. The correct use of the oil seals is guaranteed up to an internal pressure of 0.5 bar. Boxes designed to be used for particularly heavy duty work are equipped with a breather cap that can be fitted on any cast iron box on request.
18 unigreen
5.3 DISTRIBUTOR ACCESSORIES
Various configurations of accessories or distributors are fitted to the outlet of the fans. At present these are: 2 Fans, Canopy and Espalier - Double espalier Minibar - RV espalier and GDC
- VL Espalier - FXF "Up and Over" boom for espalier. WARNING: for all adjustments, always observe the safety indications in the chapters relevant to maintenance and repair of this manual, as well as paragraph
2.3.1 relevant to the use of chemical products.
5.3.1 VENTAGLI (FANS) CANOPY, AND ESPALIER DISTRIBUTORS
These have been developed to adapt very simply to the type of vegetation to be treated. For dosing and distribution they are equipped with two DOSER-TAPS with 1-2­3-4 calibration (see chapter 6 SPRAYING). They turn on their own axis for the best distribution of the chemical product. The air-outlet section is differentiated to guarantee a greater range and distribution of the mixture to where it is required. In this way, the simple inversion of the distributors makes the system suitable for both the canopy and espalier versions; moving the left-hand distributor to the right-hand and vice-a-versa. (the same inversion must be performed for the two distributor taps 1-2-3-4). For particularly high espaliers an upper, double distributor is available as an OPTIONAL.
The Ventagli accessories are available with STD and XP fans.
5.3.2 MINIBAR FOR ESPALIER
Tangential flow head created to bring the diffusers closer to the areas to be treated for specific and localised operations, the vertical construction positions the distributors parallel to the vegetation area, guaranteeing uniform treatment. The variable diffusers contribute to an improved distribution of the product in relation to the requirements of the vegetation. The Minibar accessory can be used with STD fans.
5.3.2 SUPER SPALLIERA FOR ESPALIER
With this accessory you can treat particular espaliers with thick vegetation. It is especially indicated where you need to pass beyond the rows, using a lot of air and power. The variable diffusers let you direct the product in relation to the requirements of the vegetation. All of the adjustments are done by hand using the knobs and screws. The SUPER ESPALIER accessory is used with XP fans.
VENTAGLI SPALLIERA
VENTAGLI TENDONE
MINIBAR SPALLIERA
SUPER SPALLIERA
unigreen 19
5.3.3 RV BOOM FOR GDC
This boom has lateral diffusers (variable and moveable) and two top arms with hydraulic or manual adjustment, so the jets can be directed onto the vegetation to be treated. In the bottom part there are two adjustable, telescopic distributors for GDC treatment. The height of the structure can be adjusted by hand for different types of vegetation. The RV-GDC accessory is used with XP fans.
5.4 HYDRAULICS
The RV, VL, VLX, FXF and FXL model distributor accessories have hydraulics that can be controlled by the operator directly from the seat in the cab. Check that no one and nothing is in the area where the booms will open; particular attention should be paid to the presence of any electric power lines.
The hydraulic plant can be fed from the hydraulic pump of the tractor. The hydraulics can be controlled using the lever of the tractor (RV and VL) or a hydraulic distributor with mechanical or electro-hydraulic command with switches in the cabin (VLX, FXF and FXL).
- All of the controls on both versions are sustained action controls and each lever or switch has a pictogram of the relevant operation it controls.
WARNING: with hydraulic booms, don’t stand in the range of action of the machine.
Pay attention to the integrity and efficiency of the hydraulic components and in particular to the pipes to prevent the risk of bursting. Do a full check on the pipes and components at least once a year, we recommend replacing hydraulic pipes every 3-4 years.
5.4.1 OIL FEED FROM TRACTOR
(for hydraulic systems) Connect the delivery and discharge quick-fit coupling to the respective connections, respecting the direction of flow. The distributor inlet pipe is connected to the aluminium flow separator valve next to the distributor. The flow separator must be adjusted correctly so it sends less than 4-5 L/1° to the distributor. To prevent the cylinders moving at a dangerous speed, adjust the relevant chokes near the cylinders. If the registration ringnuts aren’t visible then fixed chokes are fitted. The chokes are fitted on the discharge line of the movement to slow. Any impurities in the oil could block the chokes and as a consequence block the cylinder; remove the dirt if necessary. The maximum pressure valves of the distributors are regulated to a pressure of around 150 bar. To prevent the excessive heating of the oil we recommend supplying the distributor of the sprayer only when the cylinders are being used. We recommend having qualified personnel do any adjustments. Pay attention to the integrity and efficiency of the hydraulic components and in particular to the pipes to prevent the risk of bursting. Do a full check on the pipes and components at least once a year, we recommend replacing hydraulic pipes every 3-4 years.
RV per GDC
20 unigreen
6 SPRAYING
WARNING: the indications to follow when using chemical products are indicated in paragraph 2.2.1.
6.1 DESCRIPTION OF THE DIFFUSERS
The distributor accessories of the AIRDROP range are equipped with variable diffusers (FIG. 18) that let you direct the airflow (and as a consequence the treatment) on the vegetation to treat, adapting to your various needs. According to the configuration of the accessory the diffusers have outlet mouths with different shapes and sections, furthermore they are equipped with a tap for turning the liquid on/off (R) so you can independently close one or more diffusers in the case of scarce vegetation. In the VENTAGLI version the diffuser is the fan itself.
6.1.1 NON-DRIP VALVE
There is a non-drip valve (V) on the distributors (FIG. 18) that limits and/stops the mix dripping when the supply tap is closed. In any case we recommend closing the delivery of the mix a few seconds before disconnecting the power takeoff. In versions with fans the valve is mounted immediately upstream of the dosing taps (see paragraph 6.4.1)
6.2 DESCRIPTION OF THE MFC® NOZZLES
The Unigreen low-volume pneumatic atomization system uses MFC
®
nozzles (FIG. 19) consisting of a steel wire supported by Nylon deflector vanes that also act as collectors for the liquid. The high-speed action of the air atomises the film of liquid on the wire; in this there is a high air/water surface area in contact and not just a single atomisation point, which means a big advantage in terms of uniformity and homogeneity of the jet.
6.3 MIXTURE CONCENTRATION As you may know, the pneumatic equipment are used for more or less concentrated treatments. To prepare the mixture, it is necessary to follow the instructions on the chemical product label. As a general rule, the product quantity to be sprayed on the hectare is the same as normal-volume treatments (a 20%-reduction is also possible); the water volume is reduced a lot even up to 9 times = 10 concentrations. We will try to clear this concept as regards concentration with an example for the correct use both of equipment and products. Imagine that in order to protect a normal-volume culture hectare you use 15 ml. of mixture. If the product dose recommended by the expert amounts to 100 g/hl. (normal-volume dose indicated on the label which is always to be followed), for 15 hl. You will use 1,5 kg. of prod­ucts. If you decide to reduce the water quantity per hectare at 500-300-150 litres (that is to say
concentrating 3-5-10 times), in these new water volumes we must always use 1,5 kg. of product and 1,2 kg. if necessary (for reductions up to 20%). As a consequence, the mixture concentration can vary according to the water quantity that you wish to use.
From this example, you can notice a reduction of 4 fillings and 12 ml. of
water.
5 MISTBLOWER CALIBRATION
The tables on pages 25 to 28 make it possible to determine the delivery in litres/hectares of the various equipment having the following initial data:
- position of the batching tap ringnut (Ventagli - Fans)
- calibrated plate CP (all others diffusors)
- used pressure;
- working speed (in km/h);
- working length (in meters).
FIG. 18
V
R
FIG. 19
unigreen 21
For instance, having a mistblower with fans and knowing:
- the working length L = 3,0 meters;
- the forward speed of 4,0 km/h;
- the tap ringnut in position 5;
- the pressure adjusted at 2,5 bars you will have a flow rate value of 5,6 l/min. and consequently of 280 l/ha.
Similarly, by knowing the l/ha value to be sprayed, as well as the working speed and distance, we can obtain the ringnut position and the pressure which is necessary for treatment.
As the speed values indicated in the tables will hardly correspond to the real ones, at first it will be necessary to calibrate the speed by operating in the following way. With the equipment in average working conditions (half-filled tank), with power take-off at 500 r.p.m. and with the fan/s in operation (without spraying), drive a measured base of 100 meters, possibly on the field on which you have to work and measure the time (t) in seconds that you need to drive it. Then calculate speed according to the formula:
V = S x 3,6 (1)
t whereas S is the distance in meters (in our case, 100 meters) and t is the time necessary to drive it. Example: if t = 66 seconds, you will have V = 100 x 3,6 = 5,4 km/h
66
It is recommended to repeat the calibration with 2-3 different gears in order to have more data relating to speed. As - beyond forward speed - also working width may not correspond to the ones indicated on the table, by using the flow rate in l/min. of the spraying head (see last line of table No. 3), you may obtain the volume in l/ha according to the following formula (2):
VOLUME in l/Ha. = 600 x l/min. (2)
working width (m) x working speed (km/h)
Therefore, if from the initial example only working speed is different from V = 5,4 km/h, you will have:
volume in l/ha = 600 x 5,6 = 207,4 l/ha
3 x 5,4
If also working width is different, for instance 3,5 m:
volume in l/ha = 600 x 5,6 = 177,8 l/ha 3,5 x 5,4
6.4.1 BATCHING TAPS (SEE PICTURE 20) On the equipment VENTAGLI (FANS) there are two batching taps which can be used to quickly change the flow rate to the jets; ringnut shows the position we advise of use the position from 4 to 8 (f.i. picture 20 = pos. 6). Each tap can carry out different positions. In the range of each single mode, for four different pressures set on the regulator, we obtain four different values of the litre capacity per minute, for a total of 16 values as you can observe from table pages 30-31. An increase in pressure means an increase in capacity; a decrease in pressure means a decrease in capacity. For other types of heads, the number of positions and the pressure value can be different, as you can notice on the relevant tables. PS: With optional top side diffusers are added two spreading taps additional, with adjustable independently. (see pg.31 ).
Flow regulation for machines with two flat outlet kit
The spreading tables referred to machines with two flat outlet kit – spalliera / tendone are purely as an indication , as the flow regulator and the 4-ways collector , due to the normal tolerance of machining and pressing, cannot grant a perfect uniformity of flow between left and right side. Consequently we suggest to make a test with clean water by making the following operations: By positioning the regulators as the one choose on the table, and after let working the machine at the correspondent pressure, you can collect the liquid from the 4-ways collector. (after having removed the Rilsan tubes) in a graduated container.
4916-47 4916-51 4916-55 4916-70
N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width.
Example­In the table: 280 lt/ha with row distance 3m.
280x3 = 300 Lt/ha with row distance 2,8m 2,8
FIG. 20
FIG. 21
CALIBRATED PLATE
GASKET
ANTIDRIPPING VALVE
MARKED SIDE
22 unigreen
In these conditions the two regulators must furnish a liquid flow equal to the half of the one readable from the table. In this way is possible to verify if each regulator furnish the right flow of liquid; if this does not happen , it is sufficient to screw or unscrew slightly the regulator, until to obtain the requested flow.
6.4.2 CALIBRATED PLATES CP
In the accessories provided with an anti-dripping valve on each sprayer, on the valve output there is a calibration plate which guarantees an homogeneous distribution among the various sprayers. According to the spraying table to be carried out, it is necessary to install the plate indicated in the table. NOTE: The plate must be mounted with the side bearing the initials towards the liquid output (picture 21). The values indicated on the tables are approximate; according to the mixture concentration, spraying values can be slightly different. These differences can be easily corrected by acting on the working pressure. Increasing pressure means increasing spraying and vice versa.
7 HAND LANCES
When using hand lances bear in mind the following notes: = Don’t direct the jet of liquid towards electric power lines or zones where there is electrical current, houses or where people might pass. = Don’t point the jet at people or animals. The jet can cause serious injuries simply due to the mechanical force of the liquid under pressure. = Never block the spraying lever of the lance in an open position because if the lance falls it will be uncontrollable. = At the end of work after you have stopped the pump, make sure that any residual pressure in the pipes under pressure has been drained to avoid unexpected jets when putting the lance away. There are various types of lances; with a lever, mitra spray gun and pistol grip. For further information please refer to the handbook in the package. The lever lance is controlled by opening lever A which, depending on how much it’s pressed, produces a conical spray or direct jet. The standard nozzle is Ø 1.5 The mitra spray gun can produce a direct jet or a conical spray and the type of spray is selected by pushing lever B forwards or backwards. Use lever C to open the jet. The standard nozzle is Ø 2.5 Replacement nozzles are available for all of the lances and the capacities are indicated in the tables TAB.4 and TAB.5 ( page 29).
8 MAINTENANCE
All of the maintenance operations and repairs must be carried out with the machine and cardan shaft stopped and the tank and circuit clean of any residues of chemical products. The maintenance of the mistblower is essential for maintaining a high level of safety. Also consult the single handbooks of the main components of the mistblower. WARNING: the indications to follow for using chemical products are indicated in paragraph 2.2.1.
8.1 PROGRAMMED MAINTENANCE
(TAB. N° 7, page 30) We recommend using a table of programmed maintenance to follow in time to keep the mistblower in an efficient working condition. For major and important maintenance jobs we recommend using the normal UNIGREEN assistance service available from your reseller, (if necessary) replacing parts using original spare parts only.
8.2 ROUTINE MAINTENANCE = After every treatment wash the inside of the tank and the entire circuit as
indicated in paragraph 4.13
= Periodically check that the suction and delivery filters are clean = Check the oil level in the volumetric compensator of the pump = The use of chemical products that are particularly damaging for a nitrile
rubber mix can cause the diaphragm to break before time. In these conditions check the state of the components more often. There are diaphragms made of special materials (viton and desmopan) that are available on request. = When doing treatments with copper hydroxide you should take great care to thoroughly clean the system, washing it after each treatment because hydroxides attack parts that aren’t painted or protected by hot galvanising.
C
B
A
FIG. 22
unigreen 23
To prevent chemical attacks we recommend spraying transparent paint on the parts that are most exposed to the product and equipping the mistblower with stainless steel pressure gauges.
8.2.1 CLEANING THE NOZZLES
Check the state of wear of the nozzles and replace them when the delivery is over 30-35% of the theoretical level. If you notice even a partial blockage of a nozzle proceed as follows:
- drain the pressure and stop the machine
- dismantle the screw or bayonet ringnuts holding the nozzles
- clean with a small brush or compressed air, don’t use nails, punches or
bradawls
- reassemble the nozzles and the ringnuts, replacing the filters and seals.
8.2.2 LUBRICATION
The moving mechanical components must be lubricated to prevent wear and overheating. This lubrication can be done with grease or oil: oil allows significantly higher speeds, in general grease is used to lubricate bearings with a vertical or inclined axis as it stays in the zone for longer.
8.2.3 MULTIPLIER LUBRICATION
The multiplier and disengaging boxes are normally lubricated in an “oil bath”, in special cases NLGI n.0 grease is used. The viscosity is an essential characteristic of a lubricant oil and this is indicated by the SAE (SOCIETY OF AUTO-MOTIVE ENGINEERS) classification of the oils for gearboxes and differentials. Special additives improve the capacity of the oil to maintain a lubricant film also at high pressures and temperatures. We recommended using SAE 90 oil for the multiplier and disengaging boxes. The quantity of oil is established by the level cap. A greater quantity of oil doesn’t improve the conditions of lubrication and can cause overheating in the box. Changing the oil protects the parts from the dangers associated with wear and the presence of metallic particles that can be present, especially in the first period of use. We recommend replacing the oil after the first 50 working hours and then subsequently every 500 hours. The quantity of oil needed is indicated on the sticker near the multiplier (FIG.
23)
WARNING: waste oil must not be dispersed in the environment, to dispo­se of waste oil see paragraph 8.7.1.
8.3 EXTRAORDINARY MAINTENANCE
At the end of a season of intense use, or every two years of normal use, it is a good idea to have a specialised service technician perform a general check on the machine.
8.4 REPAIRS
We recommend having the normal UNIGREEN assistance service available from our reseller perform any repairs or contact a specialised workshop. During all of the repairs, in particular when welding, the machine and the circuit must be clean of any residues of chemical product. If the machine has to be lifted (for example to change a wheel) follow the instructions in point 4.3 of the present handbook. Also make sure the machine is stopped, connected to the tractor, and use the relevant chocks to block the wheel still on the ground. If you use a jack (manual or hydraulic) make sure you use a jack that is suitable for the frame so it can’t slip and put it in the right position. The jack must be placed under the main frame of the machine near the wheel to change. Make sure the ground is compact: if necessary use wooden beams or other sufficiently resistant material to broaden the supporting base of the jack.
8.5 STORAGE IN A WAREHOUSE AND TRANSPORTATION
The sprayer must be kept in a closed place away from excessive humidity and protected from frost. Especially if electrical pressure regulators, electrical motors, a spraying computer or similar components are fitted. Before storing the machine, after you have washed it, apply a light coat of oil. If the temperature might drop to below zero, drain any residual liquid or add roughly 0.5 L of normal antifreeze for auto vehicles. To transport the machine follow the instructions in point 4.3 of the present handbook.
FIG. 23
24 unigreen
8.6 PUTTING BACK INTO SERVICE AFTER WINTER LAYUP
Before using the machine again after a long period of inactivity you should perform some general checks, following the instructions in point 4.2 and drain any antifreeze.
Never start the shaft of the pump if you think there may by ice inside. To check this, make sure you can turn the shaft by hand without connecting it to the tractor.
After you have connected the machine to the tractor (see point 4.4) following the instructions in the present user’s handbook and in the enclosures of the pump, pressure regulator and accessories.
8.7 DEMOLITION AND DISPOSAL
When the sprayer will be put out of service you should wash it with great care to remove any residues of chemical product, follow the instructions in point 4.13 of the present handbook. ATTENTION: It is necessary to adopt appropriate Individual Protection Devices in manipulating waste. The disposal of waste deriving from the demolition of the machine must be carried out respecting the environment, avoiding soil, air and water pollution. Local legislation in force in the matter must be respected in any case. Remember that waste is understood as any substance or object that enters into the categories shown in attachment A in part IV of Legislative Decree 152/2006, that the holder has destroyed, has decided or is obliged to destroy. Waste deriving from the demolition of the machine is classifiable as special waste.
8.7.1 MATERIALS FOR DEMOLITION
Non-dangerous special waste is that which can be recovered, according to the February 1998 Ministerial Decree:
· Iron, aluminium, stainless steel and copper materials
· Plastic materials
· Electronic cards
· Hydraulic oil
· Electrical plant
8.7.2 INDICATIONS FOR A SUITABLE TREATMENT OF WASTE
The Correct management of special waste envisages:
- stocking in suitable places, avoiding mixing dangerous waste with the non­dangerous.
- ensuring that authorised carriers and receivers carry out its transport and disposal/recovery. Transport of one's waste to authorised collection centres is allowed exclusively if you are enrolled in the Environmental Management Register.
8.7.3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE (EEAW)
The Italian government has adopted the European Parliament directives in the matter of the disposal of electrical and electronic waste (EEAW) (2002/95/CE and 2003/108/CE Directives) with Legislative Decree n° 151,July 25 2005). The measures: in particular, the decree established measures and procedures aimed at: a) forestalling the production of EEAW; b) promoting the re-use, recycling and other forms of EEAW recovery, in order to reduce the quantity to send for disposal; c) improving, in terms of the environment, the actions of the subjects who participate in the life-cycle of these apparatuses (producers, distributors, consumers and operators directly involved in the treatment of EEAW); d) reducing the use of dangerous substances in electrical and electronic apparatus.
The decree imposes the limitation and elimination of several substances present in EEAW: lead, mercury, cadmium, chrome, hexavalent chrome, polybrominated biphenyl, polybrominated diphenyl and polybrominated diphenyl ethers. The machine has been designed and created in conformity with this directive. Follow the indications shown below. The symbol to the side, showing a barred garbage can on wheels, indicates the separate collection of the electrical and electronic apparatuses of the machine.
The user of the present machine can contact the collection centres instituted by the Local Authorities or the UNIGREEN Company directly, or request withdrawal by the dealer, in order to carry out correct disposal of the waste.
unigreen 25
AIRDROP CALIBRATING TABLES
TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.CANOPY
N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.4, page 25).
unigreen spa
Tabella e rogazi one in Li tri/ettaro pe r di ffusori a ventagl i o Vr. Tendone
MFC ® system
Lt./ha spreading rate table - Fan diffusors
POSIZIONE DOSATORE
Larghezza
45678di lavoro
PRESSIONE bar
22.53 22.53 22.53 22.53 22.53
working width
4 224 240 270 30 4 3 36 408 461 492 566 638 648 744 835 826 936 5 180 192 216 243 269 326 369 394 453 511 518 595 668 660 749 6 150 160 180 202 224 272 307 328 378 426 432 496 557 550 624 2.5 7 128 137 154 173 192 233 263 281 324 365 370 425 477 472 535 8 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468
2.5 m .
4 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 5 150 160 180 202 224 272 307 328 378 426 432 496 557 550 624 6 125 133 150 169 187 227 256 273 315 355 360 413 464 459 520 3 7 107 114 129 145 160 194 219 234 270 304 309 354 398 393 446 8 94 100 113 127 140 170 192 205 236 266 270 310 348 344 390
3 m.
4 140 150 169 190 210 255 288 308 354 399 405 465 522 516 585 5 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468 6 94 100 113 127 140 170 192 205 236 266 270 310 348 344 390 4 7 80 86 96 108 120 146 165 176 202 228 231 266 298 295 334 8 70 75 84 95 105 128 144 154 177 200 203 233 261 258 293
4 m.
Litri/min. 3.74 4.00 4.50 5.06 5.60 6.80 7.68 8.20 9.44 10.64 10.80 12.40 13.92 13.76 15.60
Tab.3215/0XXXF
Velocità Km/h
s
p
eed
Litri/haLitri/haLitri/ha
s
p
eed
Velocità Km/h
s
p
eed
Velocità Km/h
26 unigreen
AIRDROP CALIBRATING TABLES
TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI (FANS) VR.ESPALIER
+
ATTENTION: the OPTIONAL tabel shows the spreading rate of the two top side diffusers only, which has always to be added
to that one of the fans.
In the table examples the total spreading of the machine is: Fan table = 336 Lt/he Table of optional diffusers = 240 Lt/he TOTAL MACHINE : 336+240= 576 Lt/he
PS: The spreading taps are all adjustable independently, the approximate configuration for a standard use is 2/3 spreadings about to the fans and 1/3 to the diffusers. For special needs it's possible to change the proportions by setting the calibration of the taps.
TABLES FOR CALIBRATING AIRDROP 2 VENT. (FANS) ESPALIER TOPDIF.
OPTIONAL
unigreen spa
Tabella erogazione in Litri/ettaro per erogatori superiori opzionali Vr. Spallie ra
MFC ® s ystem
Lt./ha s p r ea di ng r a te table - Optional Top dif fusors
POSIZI ONE DOSATORE
Larghezza
4567
di lavoro
PRESSIONE bar
22.53 22.53 22.53 22.53
work ing wi dth
4 180 204 216 282 300 354 405 474 525 567 648 720 5 144 163 173 226 240 283 324 379 420 454 518 576 6 120 136 144 188 200 236 270 316 350 378 432 480 2 7 103 117 123 161 171 202 231 271 300 324 370 411 8 90 102 108 141 150 177 203 237 263 284 324 360
2 m.
4 144 163 173 226 240 283 324 379 420 454 518 576 5 115 131 138 180 192 227 259 303 336 363 415 461 6 96 109 115 150 160 189 216 253 280 302 346 384 2.5 7 82 93 99 129 137 162 185 217 240 259 296 329 8 72 82 86 113 120 142 162 190 210 227 259 288
2,5 m.
4 120 136 144 188 200 236 270 316 350 378 432 480 5 96 109 115 150 160 189 216 253 280 302 346 384 6 80 91 96 125 133 157 180 211 233 252 288 320 3 7 69 78 82 107 114 135 154 181 200 216 247 274 8 60 68 72 94 100 118 135 158 175 189 216 240
3 m.
Litri/min. 2.40 2.72 2.88 3.76 4.00 4.72 5.40 6.32 7.00 7.56 8.64 9.60
Tab 3215/0XXXF
Velocità Km/h
s
p
ee
d
Litri/haLi tri/haLitri/ha
s
p
eed
Velocità Km/h
s
p
eed
Velocità Km/h
unigreen spa
Tabella erogazione in Litri/ettaro per diffusori a ventaglio Vr. Spalliera
MFC ® s ystem
Lt. /ha sprea ding r ate table - Fan dif fusors
POSIZIONE DOSATORE
Larghezza
45678
di lavoro
PRESSIONE bar
22.53 22.53 22.53 22.53 22.53
work ing wi dth
4 281 300 338 380 420 510 576 615 708 798 810 930 1044 1032 1170 5 224 240 270 304 336 408 461 492 566 638 648 744 835 826 936 6 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 2 7 160 171 193 217 240 291 329 351 405 456 463 531 597 590 669 8 140 150 169 190 210 255 288 308 354 399 405 465 522 516 585
2 m.
4 224 240 270 304 336 408 461 492 566 638 648 744 835 826 936 5 180 192 216 243 269 326 369 394 453 511 518 595 668 660 749 6 150 160 180 202 224 272 307 328 378 426 432 496 557 550 624 2.5 7 128 137 154 173 192 233 263 281 324 365 370 425 477 472 535 8 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468
2,5 m.
4 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 5 150 160 180 202 224 272 307 328 378 426 432 496 557 550 624 6 125 133 150 169 187 227 256 273 315 355 360 413 464 459 520 3 7 107 114 129 145 160 194 219 234 270 304 309 354 398 393 446 8 94 100 113 127 140 170 192 205 236 266 270 310 348 344 390
3 m.
Litri/min. 3.74 4.00 4.50 5.06 5.60 6.80 7.68 8.20 9.44 10.64 10.80 12.40 13.92 13.76 15.60 Tab.3215/0XXXF
Velocità Km/h
s
p
eed
Litri/haLitri/haLi tri/ha
s
p
eed
Velocità Km/h
s
p
eed
Velocità Km/h
unigreen 27
TABLES FOR CALIBRATING AIRDROP MINIBAR
AIRDROP CALIBRATING TABLES
N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.4, page 21).
unigreen spa
Tabella erogazione in Litri/ettaro per MINIBAR spalliera (6 diffusori)
MFC ® system
Lt./ha sp re ading ra te table - MINIBAR
PIASTRINA CALIBRATA Calibrated plate
4916/40 4916/47 4916/55 4916/70
Larghezz a di lavor o
PRESSIONE bar
1,522,531,522,531,522,531,522,53
working width
3,5 276 313 362 395 456 504 536 572 539 597 646 692 892 990 1035 1107
4 241 274 317 346 399 441 469 501 472 523 565 606 780 866 905 969 5 193 219 253 276 319 353 375 401 378 418 452 484 624 693 724 775 2,5 6 161 182 211 230 266 294 313 334 315 348 377 404 520 577 604 646 7 138 156 181 197 228 252 268 286 270 299 323 346 446 495 517 554
2,5 m .
3,5 230 261 302 329 380 420 447 477 449 498 538 577 743 825 862 923
4 201 228 264 288 332 367 391 417 393 436 471 505 650 722 755 807 5 161 182 211 230 266 294 313 334 315 348 377 404 520 577 604 646 3 6 134 152 176 192 222 245 261 278 262 290 314 336 433 481 503 538 7 115 130 151 165 190 210 223 238 225 249 269 288 371 412 431 461
3 m.
3,5 197 223 259 282 326 360 383 409 385 427 461 494 637 707 739 791
4 172 195 226 247 285 315 335 358 337 373 403 433 557 619 647 692 5 138 156 181 197 228 252 268 286 270 299 323 346 446 495 517 554 3,5 6 115 130 151 165 190 210 223 238 225 249 269 288 371 412 431 461 7 98 112 129 141 163 180 191 204 193 213 231 247 318 354 370 395
3,5 m .
Litri/min. 4,02 4,56 5,28 5,76 6,65 7,34 7,82 8,35 7,87 8,71 9,41 10,1 13 14,4 15,1 16,1 TOTALE / total
Litri/min. 0,67 0,76 0,88 0,96 1,11 1,22 1,3 1,39 1,31 1,45 1,57 1,68 2,17 2,41 2,52 2,69 SINGOLA / single
Tab. 3215/0578F
Velocità Km/h
s
p
eed
Litri/haLitri/haLitri/ha
Velocità Km/h
s
p
eed
Velocità Km/h
s
p
eed
unigreen spa
Tabella erogazione in Litri/ettaro per MINIBAR spalliera (8 diffusori)
MFC ® system
Lt./ha spreading rate table - MINIBAR (8 diffusors)
PIASTRINA CALIBRATA Calibrated plate
4916/40 4916/47 4916/55 4916/70
Larghezz a di lavor o
PRESSIONE bar
1,522,531,522,531,522,531,522,53
working width
3,5 368 417 483 527 608 671 715 763 719 797 861 923 1189 1320 1380 1476
4 322 365 422 461 532 588 625 668 629 697 753 807 1040 1155 1207 1292 5 257 292 338 369 425 470 500 534 503 558 602 646 832 924 966 1033 2,5 6 214 243 282 307 355 392 417 445 420 465 502 538 693 770 805 861 7 184 208 241 263 304 336 357 382 360 398 430 461 594 660 690 738
2,5 m .
3,5 306 347 402 439 507 560 596 636 599 664 717 769 991 1100 1150 1230
4 268 304 352 384 443 490 521 556 524 581 628 673 867 962 1006 1076 5 214 243 282 307 355 392 417 445 420 465 502 538 693 770 805 861 3 6 179 203 235 256 295 326 347 371 350 387 418 449 578 642 671 718 7 153 174 201 219 253 280 298 318 300 332 359 384 495 550 575 615
3 m.
3,5 263 298 345 376 434 480 511 545 514 569 615 659 849 943 985 1054
4 230 261 302 329 380 420 447 477 449 498 538 577 743 825 862 923 5 184 208 241 263 304 336 357 382 360 398 430 461 594 660 690 738 3,5 6 153 174 201 219 253 280 298 318 300 332 359 384 495 550 575 615 7 131 149 172 188 217 240 255 273 257 284 307 330 425 471 493 527
3,5 m .
Litri/min. 5,36 6,08 7,04 7,68 8,86 9,79 10,4 11,1 10,5 11,6 12,6 13,5 17,3 19,2 20,1 21,5 TOTALE / total
Litri/min. 0,67 0,76 0,88 0,96 1,11 1,22 1,3 1,39 1,31 1,45 1,57 1,68 2,17 2,41 2,52 2,69 SINGOLA / single
Tab. 3215/0578F
Litri/haLitri/haLitri/ha
Velocità Km/h
s
p
eed
Velocità Km/h
s
p
eed
Velocità Km/h
s
p
eed
OPTIONAL
28 unigreen
AIRDROP CALIBRATING TABLES
N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width indicated in the table and divide it by the new width (see chapter 6.4, page 21).
TABLES FOR CALIBRATING AIRDROP SUPER SPALLIERA
unigreen spa
Tabella erogazione in Litri/ettaro per SUPER SPALLIERA (8 diffusori)
MFC ® system
Lt./ha spreading rate table - SUPER SPALLIERA (8 diffusors)
PIASTRINA CALIBRATA
Calibrated plate
4916/40 4916/47 4916/55 4916/70
Larghezza di lavoro
PRESSIONE bar 1,522,531,522,531,522,531,522,53
working width
3,5 368 417 483 527 608 671 715 763 719 797 861 923 1189 1320 1380 1476
4 322 365 422 461 532 588 625 668 629 697 753 807 1040 1155 1207 1292 5 257 292 338 369 425 470 500 534 503 558 602 646 832 924 966 1033 2,5 6 214 243 282 307 355 392 417 445 420 465 502 538 693 770 805 861 7 184 208 241 263 304 336 357 382 360 398 430 461 594 660 690 738
2,5 m.
3,5 306 347 402 439 507 560 596 636 599 664 717 769 991 1100 1150 1230
4 268 304 352 384 443 490 521 556 524 581 628 673 867 962 1006 1076 5 214 243 282 307 355 392 417 445 420 465 502 538 693 770 805 861 3 6 179 203 235 256 295 326 347 371 350 387 418 449 578 642 671 718 7 153 174 201 219 253 280 298 318 300 332 359 384 495 550 575 615
3 m.
3,5 230 261 302 329 380 420 447 477 449 498 538 577 743 825 862 923
4 201 228 264 288 332 367 391 417 393 436 471 505 650 722 755 807 5 161 182 211 230 266 294 313 334 315 348 377 404 520 577 604 646 4 6 134 152 176 192 222 245 261 278 262 290 314 336 433 481 503 538 7 115 130 151 165 190 210 223 238 225 249 269 288 371 412 431 461
4 m.
Litri/min. 5,36 6,08 7,04 7,68 8,86 9,79 10,4 11,1 10,5 11,6 12,6 13,5 17,3 19,2 20,1 21,5
TOTALE / total
Litri/min. 0,67 0,76 0,88 0,96 1,11 1,22 1,3 1,39 1,31 1,45 1,57 1,68 2,17 2,41 2,52 2,69 SINGOLA / single
Tab. 3215/000F
Litri/haLitri/haLitri/ha
Velocità Km/h
s
p
eed
Velocità Km/h
s
p
eed
Velocità Km/h
s
p
eed
MFC ® system
UNIGREEN S.p.A.
PIASTRINA CALIBRATA
Calibrated plate
4916/34 4916/40 4916/47 4916/51
Larghezza di lavoro
PRESSIONE bar
1,5 2 2,5 3 1,5 2 2,5 3 1,5 2 2,5 3 1,5 2 2,5 3
working width
3,5 309 357 398 439 459 521 603 658 760 839 893 954 818 900 976 1041
4 270 312 348 384 402 456 528 576 665 734 782 835 716 788 854 911 5 216 250 278 307 322 365 422 461 532 588 625 668 573 630 684 729 2,5 6 180 208 232 256 268 304 352 384 443 490 521 556 477 525 570 607 7 154 178 199 219 230 261 302 329 380 420 447 477 409 450 488 520
2,5 m.
3,5 257 297 331 366 383 434 503 549 633 699 745 795 682 750 814 867
4 225 260 290 320 335 380 440 480 554 612 652 696 597 657 712 759 5 180 208 232 256 268 304 352 384 443 490 521 556 477 525 570 607 3 6 150 173 193 213 223 253 293 320 369 408 434 464 398 438 475 506 7 129 149 166 183 191 217 251 274 317 350 372 397 341 375 407 434
3 m.
3,5 193 223 249 274 287 326 377 411 475 525 558 596 511 563 610 651
4 169 195 218 240 251 285 330 360 416 459 489 522 447 492 534 569 5 135 156 174 192 201 228 264 288 332 367 391 417 358 394 427 455 4 6 113 130 145 160 168 190 220 240 277 306 326 348 298 328 356 380 7 96 111 124 137 144 163 189 206 237 262 279 298 256 281 305 325
4 m.
Litri/min. 4,5 5,2 5,8 6,4 6,7 7,6 8,8 9,6 11,1 12,2 13 13,9 11,9 13,1 14,2 15,2 TOTALE / total
Litri/min. 0,45 0,52 0,58 0,64 0,67 0,76 0,88 0,96 1,11 1,22 1,3 1,39 1,19 1,31 1,42 1,52
SINGOLA / single
Tab. 3215/0000
Litri/haLitri/haLitri/ha
Velocità Km/h
s
p
ee
d
Velocità Km/h
s
p
ee
d
Lt./ha spreading rate table RV -GDC (10 diffusors)
Tabella erogazione in Litri/ettaro per RV GDC (10 diffusori)
Velocità Km/h
s
p
ee
d
TABLES FOR CALIBRATING AIRDROP RV-GDC
unigreen 29
TABLE 4-5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES
TABLE OF DELIVERY IN LITRES / MIN. OF THE CONICAL NOZZLES FOR MITRA SPRAY GUN
note: standard Ø2,5 nozzle
DIAMETER NOZZLE Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,8 Ø 2,0 Ø 2,3 Ø 2,5 Ø 3,0
PRESSURE (BAR) JET CAPACITY ( Lt / min )
15 cone 2,45 3,60 4,60 5,90 6,90 8,10 9,20 11,5
direct jet 2,50 3,80 5,10 7,30 8,80 10,8 13,0 18,4
25 cone 3,00 4,25 5,70 7,20 8,10 10,2 11,4 14,4
direct jet 3,10 4,60 6,50 9,30 11,7 14,1 16,4 24,1
35 cone 3,40 4,70 6,60 8,50 10,2 12,9 14,0 18,0
direct jet 3,50 5,40 7,40 10,8 13,4 16,8 19,1 28,2
40 cone 3,55 5,20 6,90 9,20 10,9 13,7 14,5 18,8
direct jet 3,65 5,90 7,80 11,7 14,3 17,9 21,0 30,1
50 cone 4,00 5,60 7,70 10,5 12,5 14,9 16,4 20,9
direct jet 4,10 6,30 8,60 12,7 15,8 19,7 23,0 33,0
TABLE. 5
TABLE OF DELIVERY IN LITRES / MIN. OF THE CONICAL NOZZLES FOR LEVER LANCE
note: standard Ø1,5 nozzle
DIAMETER NOZZLE Ø 1,0 Ø 1,2 Ø 1,5 Ø 1,75 Ø 2,0 Ø 2,2 Ø 2,5
PRESSURE (BAR) JET CAPACITY ( Lt / min )
5 cone 1,16 1,40 1,90 2,25 2,65 2,90 3,50
direct jet 1,40 1,70 2,50 3,95 4,7 6,00 7,70
8 cone 1,40 1,80 2,60 2,80 3,40 3,65 4,45
direct jet 1,70 2,20 3,40 4,85 6,00 7,60 9,80
10 cone 1,50 1,96 2,90 3,10 3,90 4,10 5,00
direct jet 1,90 2,40 3,75 5,40 6,95 8,55 11,0
15 cone 1,88 2,40 3,40 3,80 4,50 5,00 6,10
direct jet 2,30 3,00 4,50 6,65 8,30 10,4 13,4
30 cone 2,60 3,40 4,80 5,40 6,30 7,10 8,70
direct jet 3,20 4,20 6,40 9,40 11,7 14,7 19,1
50 cone 3,40 4,40 6,20 6,80 8,10 9,20 11,2
direct jet 4,10 5,40 8,30 11,8 15,1 19,1 24,6
TABLE. 4
TABLE 3 TABLES OF DELIVERY CALIBRATED PLATE
CP4916/34 CP4916/40 CP4916/47 CP4916/51 CP4916/55 CP4916/70
Pressure 1,5 Bar
0,45 0,67 1,11 1,19 1,31 2,17
2,0 Ba r
0,52 0,76 1,22 1,31 1,45 2,41
2,5 Ba r
0,53 0,88 1,30 1,42 1,57 2,52
3,0 Ba r
0,64 0,96 1,39 1,52 1,68 2,69
TAB.3
Code: 2403/0054F 2403/0180F 2403/0161F 2403/0060F 2403/0048F 2403/0162F
TABL E OF DELIV ERY I N L IT RES /M IN. CAL IBRAT ED P L AT E Calibrated Plate
30 unigreen
TABLE 7 TABLE OF PROGRAMMED MAINTENANCE
OPERATION 8 h 50 h 300 h END
OF SEASON
Check the level and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes, unions) 0 Check and clean the suction 0 and delivery filters Check the pump fixing feet 0 and screws in general Check the diaphragm and the oil X (1) X (2) and change if necessary Check the suction/delivery valves X X Check the pump screws and bolts are tight X Check and clean the nozzles and the non-drip diaphragm 0 Check the wear of the nozzles 0 Check the hydraulic oil level 0 Check any failures or cracking of the welds, 0 especially on herbicide booms Grease the articulated joints and the wheel hubs 0 Check the tyre pressure 0
NOTE: 0 Operation to be carried out by the operator
X Operation to be carried out by a specialised technician or in an authorised workshop (1) First oil change (2) Change at the same time a changing the diaphragm
TABLE 8 PROBLEMS, CAUSES AND SOLUTIONS
PROBLEMS CAUSES SOLUTIONS
The pump won’t charge Air suction Check the suction system
Adjustment valve closed Position the lever correctly (Command group isn’t at zero pressure)
Valves and/or valve seats Replace or clean ( * ) suction and delivery worn or dirty
The pump doesn’t reach the set Valve and/or valve seat Replace ( * ) pressure adjustment worn
Valves and/or valve seats suction Replace or clean ( * ) and delivery worn or dirty
Insufficient rpm Bring speed up to correct rpm
always in the field of 350 ÷ 550 rpm.
The nozzles used are worn or have Replace holes that are too big
Suction blocked Clean the cartridge of the
filter or remove the blockage
Irregular pressure (with impulses) Valves and/or valve seats Replace or clean ( * )
suction and delivery worn or dirty
Air suction Check the suction system
Excessive vibrations at delivery Pressure accumulator discharged Bring the air pressure back up to the right
or incorrect air pressure value (see pump handbook) ( * )
Noisiness and the level of the oil Blocked suction Check the suction system has dropped
Water in the oil Breakage of one or more diaphragms Replace ( * ) If the replacement isn’t
done immediately, drain the water out of the pump and introduce clean oil without water (also used) or diesel to stop rust attacking the internalparts
No liquid comes out of the nozzles Delivery filter dirty Clean
Non-drip filters dirty Nozzles blocked
NOTE: ( * ) Only specialised technician
unigreen 31
TAB.18A ALLOWED FITTINGS
2009 MOUNTED ATOMISERS
TYPE OF Polyethylene Tank MACHINE
TAB. 18 a
P302 P402 P500 P602
FITTING
Nominal capacity (L.) 300 400 500 600
FAN GROUP XPV Ø500 XXXX PUMPS " " APS 51 XXXX COMET " " APS 71 XXXX
" " APS 96 PRESSUREGCP 2 ELECTRIC XXXX REGULATORGCP 2 ELECTRIC +PRESXXXX
NOZZLES MFC XXXX
DISTRIBUTOR2 VENTAGLI XXXX ACCESSORIESMINIBAR XXXX
SUPER SPALLIERA XXXX
RV XXX
RV GDC XXX OPTIONALTOP DISTR for VENTAGLIXXXX
MIXER LP83 XXXX
COMPUTER X X X
TOTAL MASS EMPTY MAX FITINGS 280 370 380 390 in Kg FULL MAX FITINGS 640 920 1030 1140 P HP POWER NECESSARY 35 35 35 35
AIRDROP - ELETTRA -MFC
Descriptions, indicative illustrations, UNIGREEN S.P.A. reserves the right to make variations or modifications without prior warning.
via Rinaldi, 105 - 42124 Reggio Emilia - ITALY
Tel. +39 0522 369811 Fax. +39 0522 369898
e-mail: info@unigreen-spa.com
internet: www.unigreen-spa.com
member of the group
UNI 16100005F - GB Apr-10
Loading...