Unidrive M600, H300, F300, E300, E200 Installation Sheet

Unidrive M600-M70X, F300, H300, E200 & E300
WARNING
WARNING
123
Size 5 Through-panel Mounting Installation Sheet

1 Safety information

Follow the instructions
The mechanical and electrical installation instructions must be adhered to. Any questions or doubt should be referred to the supplier of the equipment. It is the responsibility of the owner or user to ensure that the installation of the drive and any external option unit, and the way in which they are operated and maintained, comply with the requirements of the Health and Safety at Work Act in the United Kingdom or applicable legislation and regulations and codes of practice in the country in which the equipment is used.
Competence of the installer
The drive must be installed by qualified personnel who are familiar with the requirements for safety and EMC. The installer is responsible for ensuring that the end product or system complies with all the relevant laws in the country where it is to be used.

2 Introduction

This document covers through-panel mounting instructions for Unidrive M600 / M70X, F300, H300, E200 & E300 Size 5 drives. The standard drive is rated to IP20 pollution degree 2 (dry, non-conductive contamination only, NEMA 1), however it is possible to configure the device to achieve IP65 rating (NEMA 12). This is done by sealing the heat sink vents at the rear of the heatsink by installing the high IP inserts as illustrated in Figure 3-1. Some current derating is required, and reference should be made to the drive User Guide for current derating information.
The following items are supplied in the kit bag:
Table 2-1 Contents of the bag (CT Part Number: 3470-0067)
Description Image Qty

3 Instructions

3.1 Installing the high IP inserts

Figure 3-1 Installing the high IP inserts
Through panel mounting gasket x 1
Through panel securing brackets x 2
High IP inserts x 2
Through panel mounting installation sheet
The following items are included in the kit boxes 3470-0071 and 3470-0072, both of which are supplied with the drive.
Table 2-2 Additional items required
Description Image Qty
Frame 5 mounting brackets x 2
x 1
1. To install the high IP inserts, first unclip the baffle plate using a flat bladed screwdriver inserted under the slot as shown in Figure 3-1 (1).
2. Pull the hinged baffle plate down to expose the ventilation holes. Install the two high IP inserts into the ventilation holes in the heatsink (2). Ensure the high IP inserts are fully installed by pressing them firmly into place.
3. Close the hinged baffle plate by rotating it upwards until the clips on the baffle plate are secure within the slots in the drive chassis as shown in (3).
0478-0103-04

3.2 Preparing the backplate

106 mm (4.17 in)
156.6 mm (6.16 in)
359 mm (1
4.13 in)169 mm (6.65 in
)
26 mm
(1.02 in)
167 mm (6.58 in)
26 mm
(1.02 in)
393 mm (15.47 in)
136 mm (5.35 in)
6.5 mm (0.3 in)
(x 4 holes)
5.2mm (0.20 in) (x 4 holes)
135 mm (5.32 in)
67 mm (2.64 in)
17 mm
(0.66 in)
53 mm (2.1 in) 53 mm (2.1 in)
78.3 mm (3.08 in)
78.3 mm (3.08 in)
68 mm (2.67 in)
68 mm (2.67 in)
Radius 1.0 mm
(0.04 in)
Figure 3-2 Backplate mounting detail
Prepare the backplate in accordance with the mounting dimensions shown in Figure 3-2.

3.3 Preparing for installation

Figure 3-3 Installing the gasket
1. Install the main gasket with the kit provided as shown (1).
2. The image on the right shows the assembled drive and gasket (2).