IMPORTANT
NOTE ALSO THE INFORMATION GIVEN ON THE HEATER
The Installation must be carried out by trained personnel. A means for disconnection must be incorporated in the xed wiring by a double pole switch with a
contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations.
The heater must not be installed immediately below a xed socket outlet. The heater is not suitable for connection to a 30A ring circuit. Do not position the heater under windows where curtains can contact the heater casing.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT. This heater meets EN60335 safety requirements. However, any heater type becomes hot in normal
operation. Care must be taken to ensure that prolonged skin contact with the heater does not occur.
WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE
MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
This appliance is very heavy and must be securely fi xed to a wall. DO NOT UNDER ANY CIRCUMSTANCES
ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.
To maintain stability, it is essential that the heater is placed on a level surface and care should be taken
to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater.
This heater must be installed where it is impossible for switches and other controls to be touched by a
person using a bath or shower.
IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the fi rst few
days of operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS
DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART.
87570
INSTALLATION INSTRUCTIONS
PREPARATION
The heater will arrive separately from its storage bricks, the following bricks will be required:
Model 706N - 4 bricks
Model 712N - 8 bricks
Model 718N - 12 bricks
Model 724N - 16 bricks
Only heat resisting cable (min. rating T85) should be used. The wires in the mains cable will be coloured as follows:-
GREEN & YELLOW - EARTH BLUE - NEUTRAL BROWN - LIVE
SUGGESTED FIXINGS
SOLID BRICK/BLOCK: No. 10 Size plastic inserts,
8mm drill bit. Drill hole 15mm deeper than plastic insert length.
PLASTERBOARD - If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable.
NOTE: FOR OTHER WALL TYPES (eg. Timber frame and hollow concrete) SEEK SPECIALIST ADVICE.
FIXING ASSEMBLY
1. ENSURE THAT FIXING KIT AND FEET HAVE BEEN LOCATED BEFORE DISPOSING OF PACKAGING.
2. Fit the feet with the open end of the foot to the front of the heater. Secure each foot using two taptite screws provided in the fi xing kit.
2.
3. Place the heater on its feet and in the desired position against the wall. Ensure the heater is based on a fi rm level surface at least 75mm from any end wall and at least 250mm below any shelf or similar projection. Cut away any gripper rod or carpet which would prevent the heater sitting fi rmly on the fl oor.
3.
4. Mark the position of the two outside corners of the wall bracket with the heater pushed tight against the wall. Remove the wall bracket from the heater by removing the screw at each end. Place the heater to one side and reposition the bracket against the wall using the corner marks for alignment.
Four fi xing positions must be chosen for the 724N, three for the 718N and two for the 712N and 706N. Mark the positions for the fi xing holes - two at the extreme ends and the others spaced evenly between them. Remove the bracket from the wall, drill the holes in the positions marked, and insert suitable fi xings previously described. Secure the wall bracket to the wall.
4.
5. If mains connection is to be made from the left side, at this point the mains lead must be secured to the back of the heater using ties provided in the fi xing kit.
5.
WARNING - This appliance must be earthed
6. THE FOLLOWING MUST BE APPLIED WHEN FIXING THE HEATER TO THE WALL BRACKET
6.
i) If no skirting board is present secure the heater through
the wall bracket slots closest to the wall.
ii) If 100mm (4in.) skirting is present secure the heater
through the outer slots.
iii) If skirting taller than 150mm (6in.) is present this must be
reduced to 150mm (6in.) over the entire width of the heater
plus 25mm (1in.) at each end. Do not fully tighten these screws until the bricks are loaded into the heater as some settling of the heater may occur.
NOTE: NEVER REMOVE THESE SCREWS WITHOUT FIRST UNLOADING THE HEATER.
7. Remove the front panel by removing the two self tapping screws along its bottom edge. With hands positioned on each side of the panel, lift upwards to unhook the top edge whilst pressing down on the top panel with your thumbs. The panel can now be lifted clear and set to one side.
8.
8. Remove the inner front by removing the screws along its top and sides. As the front insulation is attached care must be taken when lifting this panel from the heater and placing it to one side. Remove the internal packing by sliding it up and off the elements taking care not to damage the insulation.
9.
9. Remove one element to allow access for the back rows of bricks. On the 724N remove the element to the right of centre, on the 718N remove the central element, on the 712N the left hand element should be removed and, on the 706N, there is only one element. Loosen the two screws securing the element tails in the ceramic connector block, and lift the element up and out of the heater.
10. Carefully fi t the bottom row of the back layer of bricks placing the two end bricks in position fi rst with the recess towards the element. Fit the top row of bricks also with the recess towards the element.
11. Refi t the element which has been removed by feeding the tails down through the hole in the base insulation and into the connector block. Ensure the element is fully pushed home then securely tighten the two screws in the block.
11.
12. Fit the front layer of bricks again with the recess towards the element. The complete core will comprise:
706N - 1 x 4 Brick Columns 712N - 2 x 4 Brick Columns 718N - 3 x 4 Brick Columns 724N - 4 x 4 Brick Columns
13. Replace the inner front complete with insulation by locating its bottom edge behind the front lip of the chassis and inserting retaining screws along the top and both sides.
14. For models 712N, 718N and 724N only, check that the ap mechanism operates freely on its hinges and that with the output control set to 1 the fl ap is correctly seated in its closed position.
15. Feed the mains cable through the cable clamp and make connections as marked on heater. Pull back any slack through the clamp and tighten clamping screw. Make sure clamp is tightening on outer sheath of cable and not on individual conductors.
15.
WARNING - This appliance must be earthed
16. Replace outer front panel and grille by hooking the grille into its retaining slot on the top panel and lowering it into position. Secure the front panel with the two self tapping screws.
16.
17. Check that the screws securing the heater to the wall bracket have been fully tightened.
IT IS ESSENTIAL THAT ALL SCREWS ARE REPLACED TO ENSURE EARTH CONTINUITY.
Once installed do not attempt to reposition the heater without rst obtaining the services of a competent electrician.
7.
ENSURE THAT CABLE CLAMP IS SECURELY ATTACHED TO THE CHASSIS OF THE HEATER
OPERATING INSTRUCTIONS
This storage heater takes in Energy
when electricity tariffs are low and
dissipates it when tariffs are normal.
OPERATION
SAFETY INSTRUCTIONS
1. Ventilate rooms well during commissioning
2. Do not move the heater in any way once installed without the services of a competent electrician.
3. Do not cover the heater with clothing etc. at any time or position furniture close to or against the heater.
4. Ensure a clearance of at least 150mm between heaters and curtains.
5. Floor standing heaters must only be fi tted with the back against a wall.
6. Should your heater fail to operate either employ the services of a competent electrician or Telephone (0845) 600 5111.
ALSO REFER TO COVER PAGE
COMMISSIONING
Set both the Input Control and the Output Control to 6 and
leave the heater for 48 hours.
Following the commissioning period adjust the controls as
stated below.
CONTROL FUNCTIONS
THE INPUT CONTROL
For models WMS712N, 718N, 724N only:
This heater is fi tted with a user adjustable automatic input control which varies the charge taken in response to weather conditions taking into account the amount of energy already stored in the heater. Set at 6 the heater takes maximum charge and at 1 the heater takes a minimum charge at any room temperature. The casing of the heater, particularly in late evening, may feel cool, this is quite normal. The input control may require a few days experimentation before your comfort level is established. Initially set the control to 3, the following evening if the room is too warm reduce to 2 or if it is too cool increase to 4. On subsequent evenings adjust by half divisions until your comfort level is achieved. Having established the setting the input will automatically carry the amount of heat stored to compensate for weather variations.
CLEANING
To maintain the appearance of the heater wipe occasionally with a dry cloth when the heater is cool. Do not use abrasive powders of furniture polish.
AFTER SALES SERVICE
Issue 2
SETTING THE CONTROLS
The controls are located under the hinged fl ap at the top right hand corner of the heater. To adjust the controls on the heater use a coin and engage it in the slots provided on the top surface of the knob. There are no user adjustable controls on the WMX706N.
For models WMX712N, 718N, 724N only:
Initially set the input to 4. If the heater does not maintain a satisfactory room temperature the following day this setting should be increased. Conversely if the room temperature is too high this setting should be reduced. The input control should only require seasonal adjustments.
THE OUTPUT CONTROL
For all models except WMX706N
Most of the stored heat is radiated from the casing during the discharge period. However, some of the heat is emitted through the grille at the top of the heater and this additional heat (or boost) is regulated by the Output Control. With this set to 6 the boost begins in the early afternoon. Turning the control towards 1 will progressively delay the commencement of the boost. At 3 the boost will start in the evening. Once set, the boost will repeat itself automatically day after day. If no boost is required e.g. when the room will be unoccupied for a long period, set the Output Control to 1. With the control in this position, the heater will take less energy during the next charging up period.
Part No. 87570
Discolouration of wall fi nishes can sometimes occur immediately above a storage heater due to the properties of some paints and decorating materials or the presence of environmental impurities in the air (such as soot or incense generated from the burning of candles etc.).
Your storage heater is guaranteed for two years from date of purchase. We undertake to repair or exchange within the period, any part found to be defective due to a manufacturing fault. This guarantee does not affect your statutory rights.
Should you require after sales service, please contact the supplier through whom you purchased the heater, or telephone 0845 600
5111.
Please do not initially return faulty appliance, or part of an appliance to us as this may result in transit damage and/or a delay in providing service.
Let us know your diffi culty quoting the model number and serial number (located along the wall bracket). We will then take the appropriate action.
RECYCLING
For electrical products sold within the European Community. At the end of the electrical products useful
life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your
Local Authority or retailer for recycling advice in your country.