Unidare UPX750, UPX1250, UPX750TI, UPX1250TI, UPX1500 Installation And Operating Instructions Manual

...
Installation and Operating Instructions
INUDUKP572 Issue 3
Dimensions
(millimetres)
Fig. 1
Model(s) Watts A B
UPX750 750 620 108
UPX750TI 750 620 108
UPX1250 1250 688 108
UPX1250TI 1250 688 108
UPX1500 1500 688 108
UPX1500TI 1500 680 108
UPX2000 2000 860 108
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
A
150 MIN
150 MIN
150 MIN
B
430
Important Safety Advice
When using electrical appliances, basic precautions should always be followed to
reduce the risk of re, electrical shock, and
injury to persons, including the following: IMPORTANT – The wall bracket supplied
with the appliance must be used.
WARNING – DO NOT USE THIS HEATER IN THE IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL. IMPORTANT – If the heater is installed in a
room containing a bath or shower, it must be so installed that switches and other controls cannot be touched by a person using a bath or shower. Do not use outdoors. Do not locate the heater immediately below
a xed socket outlet or connection box.
WARNING: In order to avoid overheating, do not cover the heater. Do not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or furniture, as this could cause
overheating and a re risk.
NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater.
The heater carries the Warning symbol
indicating that it must not be covered. CAUTION - Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. This appliance can be used by children aged from 8 years and above and by persons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning use of
UNIDARE
UPX.. Panel Heaters
the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. Note that due care and consideration must be taken when using this heater in series with a thermal control, a program controller, a timer or any other device that switches on
the heat automatically, since a re risk exists
when the heater is accidentally covered or displaced. If the supply cord is damaged it must be replaced by the manufacturer or service
agent or a similarly qualied person in order
to avoid a hazard. WARNING: Servicing and product repairs should only be undertaken by the manufacturers approved service agent or a
similarly qualied person, using only exact
manufacturer approved spare parts. The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm.
Operation - Timer Models
The slide switch on the timer unit controls the electricity supply to the heating elements. The switch marked I - II (half heat – full heat) provides a choice of output as desired. Switch on the heater by setting the slide switch to the
manual position. Turn the thermostat knob to
max. and set selector switch (where tted) to full
heat, to warm the room rapidly. When the room temperature has reached the desired level, turn the thermostat knob - see “Thermostat” and set
selector switch (where tted) to full heat, to warm
the room rapidly. The heater will then maintain the room temperature at the chosen level, provided that the correct size of heater has been selected for the room to be heated.
To set the time of day
The heater must be connected to the electricity supply for the timer to operate. Set the timer by rotating the dial clockwise until the correct
time of day is indicated opposite the datum mark
.
Manual Operation
Set the timer switch to manual . The heater will now operate continuously under the control of the thermostat.
Automatic Operation
Set the timer slide to automatic . Switching times can be selected in 20 minute steps. Set the desired programme by gently pulling the appropriate segments out, proud of the dial face during the ‘On’ period. The timer may be set to give as many ‘On’ periods of any length as may be required. The programme will repeat itself every 24 hours until changed.
The programme may be over-ridden at any time by switching to
manual
or to .
Operation - Non Timer Models
The switch marked and controls the electricity supply to the heating elements. The OFF position is marked .
The switch marked
- (half heat – full heat)
provides a choice of output as desired.
The heater is tted with an adjustable thermostat
enabling the room temperature to be controlled by adjusting the setting accordingly.
Thermostat
The thermostat has a minimum setting represented by . Providing the appliance has been switched ‘ON’ the heater will come on when
the surrounding temperature falls to approximately 6oC. This setting
may be used for protection against frost.
Switch on the heater and turn the thermostat knob to Max. and set selector switch (where tted) to full heat, to warm the room rapidly.
When the room temperature has reached the desired level, turn the thermostat knob back slowly until the thermostat just clicks off. The heater will then maintain the room temperature at the chosen level, provided that the correct size of heater has been selected for the room to be heated.
Useful Hints
Should your heater fail to operate please ensure:
1. The thermostat setting is higher than the room temperature
by turning the control knob to the maximum position.
2. The safety cut-out has not operated by following the procedure as detailed in ‘Safety - Overheat protection’.
General
The panel heater is designed for wall mounting on the wall brackets supplied. It should only be operated when in the upright position as shown. All models are splashproof to IP24 standard.
UPX.../TI models are tted with a 24 hour programme timer.
Before connecting the heater check that the supply voltage is the same as that stated on the heater.
Please note that lit cigarettes, candles and oil burners, combined with the convection effect of electric heaters can cause soot deposits to build up on the surface directly above and to the sides of the heater. This is not a fault of the heater. Extensive burning of candles or smoking in the operating environment of this product can produce heavy discolouration within a few months of use.
Wall Mounting
IMPORTANT – The wall brackets supplied with the appliance must
be used. The heater should be positioned observing the minimum clearances stated around the heater - see Fig. 1.
DO NOT locate the heater immediately below a xed socket outlet or connection box.
1. Remove wall mounting bracket from the back of the heater by depressing the spring latch at the top of each bracket
- see Fig. 2.
2 . F i x t h e w a l l b r a c k e t s e c u r e l y t o t h e w a l l t h r o u g h t h e f o u r
screw holes provided.
Access to the controls
To open the hinged controls cover, insert the blade of a screwdriver in the small slot on the right hand side of the cover, and gently lever the screwdriver outwards. On the 3kW model the controls are located on the top right hand corner, but the operations and functions are the same as the other models. Note: After adjustment of the controls the control cover must be closed.
Fig. 4
3. Present the heater to the wall bracket, and engage lower slots in the back with bracket.
4. Raise the heater to upright position and push the heater onto brackets to engage top latch.
Fig. 3
255 MIN
Fig. 2
The heater is tted with a length of exible cable type H05VV-F size 3 x 1.0mm2 on 0.75kW - 2.0kW models and size 3 x 1.5mm2 on 3.0kW models, for connection to the xed wiring of the premises through a suitable connection box positioned adjacent to the heater.
The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection (see Regulation 544.2.5, 17th Edition I.E.E. Wiring Regulations).
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent electrician, and be in strict accordance with the current I.E.E. regulations for Electrical Equipment in Buildings.
Loading...
+ 1 hidden pages