UNICOR HIGHTECH 315N, 315S, 315D User Manual

Press battery cover slightly and push to the direction of the arrow to open.
For the Emergency use : If [Open / Lock] button is not working, then just turn the manual lock by nger to open.
Deadbolt
Manual Lock
Open/Lock button
When auto lock is set
Default setting is auto lock so the door will be locked automatically in 3 seconds after it's closed.
Press [Open / Lock] button of Back Ass'y or turn the manual lock knob to [Locked] position to lock the door.
Auto locking mode
Manual locking mode
Auto, Manual locking mode
Attention
Auto relocking function : When the door is not opened within 7 seconds after
the lock is open, the door is relocked automatically.
Open battery cover and press [Register button]
Open battery cover and press [Register button]
After the door is opened, auto locking sensor detects auto locking status. When the door is open(auto locking detect sensor is not working), push up [Keypad cover] and press [
] button to lock the door.
[Register button]
[Register button]
(Default setting is auto locking mode.)
1. When the auto lock function is set, if the door is closed, it will be locked automatically within 3 seconds.
2. User can set the manual lock function to unset the auto lock function to lock the door only when it's necessary.
Attention
1. If no button is pressed within 7 seconds after push up the [Keypad cover], entering mode will end with error sound.
2. When [Keypad lamp] is o, press [
] button and enter password.
Then, the door will be opened with melody.
Product Composition
Registering and changing the password
Name of parts (Front Ass'y)
Name of parts (Back Ass'y)
To open the battery cover
Locking the door from inside
315N 315D 315S
AA Battery 4pcs
Bolts for installation
Strike & Strike spacer
User Manual
Digital Keys
(315D model only)
Smart keys
(315S model only)
Emergency
power terminal
Smart key
touch point
(315S)
Front Ass'y
Opening the door from outside
Opening the door with password
Opening the door with
digital key (315D)
Push [Keypad cover] up. Push down the cover after pressing password and the door will be opened with melody.
[Entering password]
Caution
Caution
Registering the digital key/smart key (for 2way only)
When you register new digital key, smart key or register it again, you need to register all digital key or smart key at a time.
Press [Register button] and [0] button for 5 seconds and all registered digital keys or smart keys will be deleted.
2. Open [Keypad cover] of Front Ass'y and press password (4 ~ 12 digit) except [
] and [ # ] buttons.
1. Open [Battery cover] of the Back Ass'y and press [Register button] once briey.
5. Password registration is nished if you press [Registraion button].
3. Press [
] to save. 4. To register another password,
repeat No. 2 & 3.
1. Open [Battery cover] and press [Register button] briey.
2. Place the digital key or smart key on the touch point of the front ass'y.
(Whenever you contact it, registration is done with beep sound).
3. Press [Register button] to complete registration.
(Up to 3 passwords can be registered)
The door must be open while registering the password. Default password is 1,2,3,4.
Deleting digital key or smart key
1. In case of registering more than 1 password, all process should be done at a time. (Existing passwords will be deleted when registering new password)
2. When all three passwords are registered, Registration mode will be automatically end.
3. If no password is entered within 7 seconds while registering password, registration will be cancelled.
Register
button
Default setting is auto lock so the door will be locked automatically in 3 seconds after it's closed.
Locking the door from outside
Push the [Keypad cover] up and press [] button to lock the door.
When auto lock is set
Opening the door from inside
Press [Open / Lock] button of the Back Ass'y or turn the manual lock knob to [Open] position to open the door.
Back Ass'y
Digital key touch plate (315D)
Keypad cover
Keypad
Auto Lock Latch
Mounting Plate
1. Place the registered digital key to [Digital key touch plate].
2. After beep sound, the door will be opened.
1. Place the registered smart key to [Smart key touch point].
2. After beep sound, the door will be opened.
Opening the door with smart key (315S)
Installation Template
As this is a keyless digital door lock, damage may occur to parts of the dead lock system if it is not used according to the manual. Users should be fully aware of the manual and how to operate this product.
CAUTION
315 Series User Manual
Warning
Safety precautions
The precautionary measures are for the safety of the user, for the prevention of property damage, and for the avoidance of any inconveniences due to an accident. These must be read and followed properly.
Do not disassemble or alter the lock.
UNICOR HIGHTECH CO., LTD
- This manual may change without notice in case of product improvement.
- Product specifications are subject to change without prior notice.
- This manual should not be edited or changed without manufacturer's permission.
Do not install where the distance over 5mm between the door and door frame.
Please do not expose the password and change the password in regularly.
Please do not mix old with new batteries or use dierent types. Always use new alkaline batteries.
Do not clean the product with ammable materials such as alcohol, benzene or thinners. Such materials may damage the surface or cause a re.
Replace the current batteries with new ones within 1 week after the battery replacement notication melody sounded o for the rst time.
Do not press using sharp tools or press numeric button excessively.
Make sure the door is completely locked when going out.
Batteries should not be exposed directly to heat sources or ames, or submerged in water, because they may leak or explode, resulting in severe damage. Please do not use damaged batteries.
Place the batteries carefully and correctly according to their polarity (+/-). If the batteries are inserted in a wrong way, dierently from the indicated direction or polarity, leakage or rupture could occur. Pay attention to it.
Installation Template
Folding line for standard f ire-proof door
Folding line for one-side open or both-side open door
32mm diameter hole32mm diameter hole
Installation
Size
Fire proof door
Front Ass'y (Front body)
Back Ass'y (Main body)
Password
Smart key
Door thickness 40 ~ 50mm
68(W) x 173(H) x 24(D) mm
94(W) x 160(H) x 40(D) mm
4 ~ 12 digit (up to 3 password can be registered)
Digital key
Up to 100 keys can be registered (315D)
Up to 100 keys can be registered (315S)
Classcation Specication
Specication of product
Open type
* Lifetime of the batteries is based on the result of the tests by the company and is not an absolute measurement. It will vary depending on the temperature and humidity of the installed location as well as the frequency of usage and the quality of batteries. * Function, design and composition of the product may change without any prior notice for the purpose of improving the quality.
Double Locking mode
When all family members are in home, this safe mode allows no one can open the door using password or digital key or smart key from outside.
Press [Open/Lock] button of the Back Ass'y for more than 3 seconds and double locking is activated. When setup is done, you will hear beep sound.
Press [Open/Lock] button of the back ass'y or open the door with [Manual lock knob] and double locking mode is deactivated.
Double Locking mode
When double locking is set, the door will not be opened by password or digital key or smartkey from outside.
Unsetting
Setting
Battery replacement notication
When batteries are completely discharged making it impossible to open the door, this function allows the user can open the door using 9V battery from outside.
Contact DC 9V battery to external power supply terminal and open the door using registered password or digital key or smart key.
When it's time to replace batteries, you will hear melody sound to let you know when open or lock the door.
When you hear this melody, open battery cover and replace all batteries with
1.5V Alkaline batteries.
Attention
Must use general batteries, not rechargable ones.
Please be careful of batteries' polarity because it can cause leakage or
rupture if placed wrongly.
Must replace all old batteries with new ones, not partially. Do not use new ones
with discharged ones together.
It is designed to operate with the rated voltage 6V. If low voltage(4.2V ±0.3V) is
detected, melody will be generated.
If the door lock stops working or batteries are discharged in a short period of time after replacement, the batteries could be defective. It is required to contact the shop where the user purchased batteries and get new ones as replacement.
Emergency Power Supply
You can use 9V battery regardless of battery polarity.
Please remain contact of 9V battery onto the power supply terminal so that
emergency power is supplied (not rechargable).
Replace all discharged batteries with new ones right after emergency
power is supplied.
Caution
High-temperature warning system
Releasing high-temperature warning sound
When high temperature over 70 ±10 is detected, it generates warning sound over 80dB.
If incorrect password or digital key or smart key is entered 3 times consecutively, warning sound is generated and all functions are disabled for 30 seconds.
If the deadbolt is not working properly 3 times when open or lock the door, it generates melody as a warning signal.
Warning sound is disabled when registered password or digital key or smart key is entered or batteries are removed.
Trespass / Breakage alarm
30 seconds LOCK function
Notication function of the deadbolt jam
It is released when the power is reset by removing batteries. It is not released when the temperature of the product is high.
If there's any attempt to open the door by abnormal way such as widening the door gap, it generates 80dB warning sound with blink.
Releasing warning sound
Operation
If you keep experience warning sound or malfunction of the lock, you need to adjust the position of the lock again.
Attention
Attention
When warning sound is generated, the door opens automatically regardless of Double locking or Forced lock setting.
Warning sound disabled
- [7] button : If pressed repeatedly, volume will be reduced gradually.
- [8] button : Silence (except warning sound)
- [9] button : If pressed repeatedly, volume will be increased gradually.
(Default setting is stage 4 of basic setting. )
Volume Control
The user can set the volume from silence to stage 6.
Setting
[Register button] - [ # ] -
- [Register button]
[ 7 ] : Volume down
[ 8 ] : Silence
[ 9 ] : Volume up
Push up [Keypad cover] and press [#] button for 1 time. Enter registered password and press [] button.
Etiquette mode
Regardless of the current sound setting, this function makes the door lock silent for 1 time when the user wants to use it quietly.
This is one-time function so sound will be generated from next time.
This function is for apartments and other buildings with multiple households. It may be deleted upon moving in.
Master password registration & deletion
(Password / Digital key / Smart key)
[Register button]- [8] - [3] - [Register button] - [4 ~ 12 digit numer] - [Register button]
Registration
Registration
Deletion
Deletion
[Register button] - [#] - [#] - [#] - [7] - [3] - [Register button] - [ ]
- [Register button]
Master password
Key
registered password or master password
[Register button]- [8] - [6] - [Register button] - [key contact] - [Register button]
[Register button] - [#] - [#] - [#] - [7] - [6] - [Register button] - [ ]
- [Register button]
registered password or master password
Press [0] button after push up [Keypad cover] from outside and press [
] button for 5 seconds.
If the user opens the door using registered password, digital key or smart key from outside, the setting is released automatically.
Forced lock setting/unsetting from outside
This function helps strengthen the level of security by generating poweful warning sound if someone tries to unlock the door from inside when the user leaves home for long period of time.
Unsetting
Setting
[Register button] [Register button]
[Register button] [Register button]
Intrusion alert (Human hands detection system)
This function prevents intrusion by drilling a hole on the door or pressing the door open button with stick or metal wire and it makes the door open only by human hands.
Setting
Unsetting
If the password is '1234', enter fake password(random numbers) before real password, enter '1234' and the door will be opened.
Fake numbers(random numbers) + real password should not exceed 20 digit.
After entering fake numbers
(random numbers)
press '1234'
Entering trick numbers to prevent exposure password
If there's watchful person when the user enter password, this function allows the user can protect password by entering fake password before real password.
How to use
If the door is opened by [Open/Lock] button or manual lock knob from
inside, double locking mode is released automatically.
Double Locking unsetting from outside
This function allows the user can unset double locking mode from outside in case of setting double locking mode by mistake.
Unsetting
1. While the door is locked, Push the [keypad cover] up and enter the registered password.
2. Press the [#] button and press the password and press the [
] button again.
Warranty
The warranty period for all of the company’s products is 1 year from the date of purchase indicated on the warranty certicate.
Even during the warranty coverage, users need to pay (the cost for trip, technical support and parts) for some services if they are in the category of chargeable services.
User generally submit the warranty certicate or other methods that contains the installation information when needed to request a service.
If the warranty certicate is not available, users need to submit a receipt, a credit card receipt or a cash receipt instead (Except for a simple receipt)
◎◎
If it is impossible to show the purchase date, the warranty period will be applied by taking into consideration the product’s manufactured date + expiration period (6 months)
*
Details of mistakes and mishandling by the user
For products pruchased outside of Korea, please consult your local distiriboutor or reseller as warranty policies vary from country to country.
Types of consumer damage
Content of compensation
Within the warranty period
After the warranty period
The product
is used in
normal
conditions
Failure occurs within 1 month from date of purchase
Failure occurs within 1 year from date of purchase
Same failure occurs 4 times or more
The repair parts are not available at the main oce
Product replacement
Free-of-charge repair
Free-of-charge repair
Product replacement
Paid repair
Replacement after depreciation based on a xed rate.
Mistakes and
mishandling
by the user
Not the case of failure
Mistakes and mishandling by the user
Defective installation, and other reasons
Paid repair
Not the case of failure
Mistakes and mishandling by the user
Other reasons
When needed to break the product due to the loss of secret code. When the door is sagging, or installation is defective, requiring the product to be reinstalled. Request for checking the product for possible problems while there is no specic symptom of a failure. Problems in operation occur after the user installs the product directly.
A visit for repair is needed as there are mistakes and mishan dling by the user such as mistakes in replacing batteries and unskill ful use of the product.
Defective operation due to poorly inserted batteries and use of defective batteries. Failure and breaking due to the use of the product for other purposes. Failure and breaking caused by the user on purpose or from an external impact.
Failure and damage due to natu­ral disasters such as res, oods, and damage from sea water.
Penetration by water, condensa­tion and injection of chemicals, requiring the internal circuits to be replaced, and causing failures.
UNICOR HIGHTECH CO., LTD
62 EunCheong Street, Namdong-Gu, Incheon, Korea (zip. 21643)
Warning sound disabled if batteries are removed.