Unicont SPb PCH-205 Operating Manual

Unicont SPb Ltd
Power Supply/Automatic Battery Charger
PCH-205
Technical Documentation
St. Petersburg
2012
Unicont SPb Ltd Technical Documentation PCH-205
Page 2
Table of Contents
1.GENERAL DATA ............................................................................................................4
2.DELIVERY SET ...............................................................................................................4
3.SPECIFICATIONS ..........................................................................................................6
4.SAFETY ENGINEERING INSTRUCTIONS ...............................................................7
5.OPERATION PRINCIPLE .............................................................................................8
6.CONTROLS AND INDICATORS ..................................................................................9
7.INSTALLATION AND CONNECTION ......................................................................14
8.ALARM SIGNALS OF PCH-205 .................................................................................19
9.TRANSPORTATION AND STORAGE ......................................................................20
10.RECYCLING ..................................................................................................................21
11.WARRANTY ..................................................................................................................22
12.DATE OF PACKING .....................................................................................................23
13.ACCEPTANCE DETAILS ............................................................................................23
14.DATE OF COMMISSIONING .....................................................................................23
Unicont SPb Ltd Technical Documentation PCH-205
Page 3
This Operating Manual applies to the PCH-205 Power Supply/Automatic Battery
Charger.
This Manual is intended to assist in the familiarization with the design, operating principles and procedures established for the convection heater during its intended use or maintenance. This Manual can also be used as a source of information about сведений об устройстве to draw up corresponding sections in the operational documentation for the equipment, в которой this product may be used as its component part.
All information contained in this Manual is distributed by the company for information purposes only. The information is subject to changes without notification to consumers; the information may contain errors or discrepancies. The information provided may not contain obligations on the part of Unicont SPb Ltd
Unicont SPb Ltd Technical Documentation PCH-205
Page 4
1. General data
A power Supply/Automatic Battery Charger PCH-205 (hereinafter referred to as — PS, device) is designed to provide devices of the shipboard equipment with constant voltage 24 V.
Also, the device operates as a charging device (hereinafter referred to as — CHD) and carries out automatic charging of storage batteries connected to it (hereinafter referred to as — SB).
The PS is designed for operation at sea and river vessels in dry personnel facilities of the house, superstructures or enclosed decks.
The operator’s manual (OM) describes PS design and operation principles, installation, setting, and operation instructions.
The OM is designed for PS installation and setting specialists and PS users. To install the PS, an appropriate electrical safety group is required.
2. Delivery Set
1. Combined power supply/charging device PCH-205 1 ps.
2. Operator’s manual 1 ps.
The following devices can be used additionally (optionally) with this product:
1. Control panel of storage batteries BCP-136
2. Alarm unit AU-106
3. Temperature sensor of storage battery DTS-135
The PS is delivered in the following configurations (see Table 1):
Table 1. Device Configurations
Configuration Control and Management Functions
Base (see Figure 1)
- LED indication of an operation mode
- Integrated audio and light alarm
- Alarm signal acknowledgement button
With integrated control (see Figure 2)
- Button keyboard of SB current and charging voltage control
- Digital indicator of SB current and charging voltage
- LED indication of an operation mode
- Integrated audio and light alarm
- Alarm signal acknowledgement button
With remote control (see Figure 3)
- Remote unit of set point value input of SB charge (with SB control
panel ВСР-136)
- Digital indicator of SB current and charging voltage
- LED indication of an operation mode
- Integrated audio and light alarm
- Remote audio and light alarm (as a part of SB control panel ВСР-136)
- Alarm signal acknowledgement button
Unicont SPb Ltd Technical Documentation PCH-205
Page 5
Figure 1. Base Configuration PCH-205
Figure 2. Configuration PCH-205 with Integrated Control
Figure 3. Configuration PCH-205 with Remote Control
Unicont SPb Ltd Technical Documentation PCH-205
Page 6
3. Specifications
Table 2. Electrical Specifications
Parameter Integrated Power Supply Unit Integrated
Charging Device
Supply Voltage
220 V (180 V ... 264 V), 50/60 Hz,
optionally: 110 V (90 V – 132 V), 50/60 Hz
Output Voltage 24 V, constant (direct current)
9–30 V (is selected by the operator),
in base configuration 28.4 V
Output Current 40 A
0.2–20.0 А (is selected by the operator), in base configuration 20 A
Nominal Power 1,000 W 600 W
Connected SB: -
24 V, up to 200 A*h 12 V, up to 200 A*h
SB Charging Time
- maximum 10 hours up to 80% of capacity
A Number of Terminals for Connection of Loads
7 ps. (see Figure 9) 1 ps. (for connection of SB)
Integrated Protections:
- galvanic separation of output supply from the supply main
- connection of SB with reverse polarity
- protection of the battery against deep discharge (a deactivated function)
- overheat protection of PS, CHD
-
overheat protection of SB (when using a temperature sensor DTS-135)
Controls
Keyboard, digital indicator, LEDs, power supply switch (the content of controls depends on the device configuration, see para. 6)
Indicators
Digital indicator, PS state indication LEDs (the content of indictors depends on the device configuration, see para. 6)
Alarm Signals
- lack (failure) of supply voltage
- excess of the specified limits of SB charging current or voltage
- lack of SB connection (SB open-circuit failure, connection of SB with
reverse polarity, short circuit in the SB circuit)
-
discharge of SB
Types of Alarm Signals
Integrated Alarm:
- voltage-free (potential-free) relay contacts
- audio signal
- red LED
External Alarm (with devices):
- alarm unit AU-106
- panel control of storage batteries BCP-136
Unicont SPb Ltd Technical Documentation PCH-205
Page 7
Parameter Integrated Power Supply Unit
Integrated
Charging Device
Performance 85 %
Overall Dimensions 370 mm × 350 mm × 140mm
Operating Temperature:
-20 °C …+55 °C
Storage Temperature -60 °C …+70 °C
Weight 9.65 kg
Protection Class IP 22
4. Safety engineering Instructions
IMPORTANT! Do not allow contact of the device with water and water penetration
into the device.
IMPORTANT! When cleaning the device surface, do not use organic solvents to avoid
damage of the applied symbols and inscriptions.
It is prohibited to:
- allow tension of the cables connected to the PS;
- connect the PS to the networks with parameters that differ from specified in the
manual;
- use the device for purposes other than that intended;
- operate a defective device.
Loading...