Unicont SPb MV-1504, MV-1704, MV-1904, MV-2104 Operating Manual

Page 1
Unicont SPb Ltd
Marine LCD Display
MV-1504/1704/1904/2104
Operating Manual
(04-0-13122013)
2013
v.0.0
Page 2
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
Table of Contents
1.GENERAL INFORMATION ..........................................................................................4
2.DELIVERY SET ...............................................................................................................4
3.SPECIFICATIONS ..........................................................................................................5
4.MOUNTING AND CONNECTION ...............................................................................6
5.CONTROLS ....................................................................................................................10
6.TRANSPORTATION AND STORAGE ......................................................................11
7.WARRANTY ..................................................................................................................12
8.DATE OF PACKING .....................................................................................................13
9.ACCEPTANCE DETAILS ............................................................................................13
10.DATE OF COMMISSIONING .....................................................................................13
Page 2
Page 3
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
This operating manual (OM) is designed for marine LCD display MV-1504/1704/1904/2104.
The OM is designed for study of design, operation principles and operation rules of the device for its intended use and maintenance. The OM may also be a source of information about the device to compile relevant sections of the equipment operational documentation in which the device can be used as an integral part.
Important! The company-manufacturer does not assume any responsibility that comes with loss or damage resulting from use of this product or related documentation.
All information in this manual is distributed by the company for information purposes only. They are subject to change without notice of consumers; they may contain errors or inaccuracies. Information specified may not include an obligation on the part of the company Unicont Spb Ltd.
Page 3
Page 4
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
1. GENERAL INFORMA TION
Marine LCD MV-1504/1704/1904/2104 series MasterView is a multipurpose display used to output visual data received from the navigation system and other automated systems.
2. DELIVERY SET
1. Marine LCD MV-xx04 1 piece
2. Plate/desktop mounting brackets 1 piece
3. Operation Manual 1 piece
4. VGA cable 1 piece
5. DVI cable 1 piece
6. Feeding cable 1 piece
7. Sunscreen 1 piece
As an option you may choose to add the following items to the scope of supply:
Touch-sensitive screen (touch screen), model of execution is marked with MV-xx04 TS
CD with drivers.
Page 4
Page 5
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
3. SPECIFICA TIONS
Table 1. Versions
Parameter
Power supply voltage 110/220 VAC / 9...36 VDC
Power demand 40 W 60 W 80 W 100 W
Display diagonal 15” 17” 19” 21”
Viewable area of the screen 305 х 229 mm 337 х 270 mm 377 х 302 mm 432 х 324 mm
Angle of view 160° 170° 170° 178°
Contrast 400:1 1000:1 700:1 1000:1
Brightness 430 Cd/m2 300 Cd/m2 300 Cd/m2 300 Cd/m2
Response time 25 ms 5 ms 5 ms 5 ms
Resolution 1024 х 768 1280 х 1024 1280 х 1024 1600 х 1200
Point size 0.297 mm 0.264 mm 0.294 mm 0.27 mm
Vertical repetition frequency: 56–75 Hz
Horizontal repetition frequency:
Dimensions (mm) 371х340.5х77 411.5х388х75 449х418х75 510х443х81
Max. weight: 7 kg 9 kg 12 kg 15 kg
Protection class: IP 22
MV-1504 MV-1704 MV-1904 MV-2104
30–63 kHz 30–81 kHz 30–81 kHz 31–91 kHz
Storage temperature -55...+75°С
Operating temperature -25...+55°С
Backlight intensity is adjusted by the dimmer and can be fully cancelled (“deep dimming”).
Page 5
Page 6
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
4. MOUNTING AND CONNECTION
Device casing provides for it to be mounted on the desktop and on the plate.
If plate mounting is chosen, refer to the dimensional drawing (Figure 1) to prepare the location where the display is to be mounted to the control panel plate with fixing holes. If desktop mounting is chosen, attach the brackets to the display casing, prepare the location and tighten M5 screws to fix the display to the brackets.
Mounting being completed, lay connecting cables from external devices and connect it to the matching display connectors. Tighten the fixing screws to avoid their inadvertent disengagement.
After mounting and connection are completed, power the device up and ensure that the graphical data are properly output on the screen.
It is possible to connect several video signal sources (1 x VGA, 1 x DVI, 2 x AV and 1 x S­Video).
Power Connector
Power Pin 1 Pin 2
24 VDC +18...36 VDC 0 VDC
220 VAC L N
Page 6
Page 7
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
DVI Connector
Pin number
1 DATA2- 16 HOT PLUG DET
2 DATA2+ 17 DATA0-
3 DATA2/4 SHIELD 18 DATA0+
4 DATA4- 19 DATA0/5 SHIELD
5 DATA4+ 20 DATA5-
6 DDC CLK 21 DATA5+
7 DDC DATA 22 CLOCK SHIELD
8 ANALOG VSYNC 23 CLOCK+
9 DATA1- 24 CLOCK-
10 DATA1+
11 DATA1/3 SHIELD С1 ANALOG RED
12 DATA3- С2 ANALOG GREEN
Designation
Pin number
Designation
13 DATA3+ С3 ANALOG BLUE
14 +5V POWER С4 ANALOG HSYNC
15 GND С5 ANALOG GND
Composite Connection (Composite Input)
display
signal
Page 7
Page 8
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
S-Video Connector
Pin number
1 GND 3 Brightness
2 GND 4 Color
VGA Connector
Pin number
1 Red 9 NC
2 Green 10 GND
Designation
Designation
Pin number
Pin number
Designation
Designation
3 Blue 11 GND
4 GND 12 SDA
5 GND 13 HSYNC
6 Red GND 14 VSYNC
7 Green GND 15 SCL
8 Blue GND
Page 8
Page 9
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
Version
MV-1501 MV-1701 MV-1901 MV-2101
Figure 1. Dimensions
Dimension (mm)
A B C D E F G H I
371 357 60 220.5 58 14 340.5 311 343
411.5 395.5 75.5 217 58 19.5 388 352 373 449 433 75.5 247 58 19.5 418 382.5 411.5
509.5 493.5 77 269 67 17 443 410.5 475.5
Page 9
Page 10
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
5. CONTROLS
Menu Access Button
Setting Selection and Change Buttons
Set Button (to apply changed parameters and to access menu items)
Display Power on/off Button
(to choose
video signal sources)
Dimmer (Backlight)
Power LED
The following controls are located on the front panel:
1. Display Power on/off button (short-time pushing switches the display over cycle-wise
according to the video signal sources).
2. “MENU”. Enter/exit button to access the display settings menu. When in the menu, this
button allows to exit the active setting without saving the changed parameter.
3. “” and “”. Selection buttons to select a menu item/parameter measurement. When in
the menu, this buttons allow to scroll up the items (settings) up and down. If any setting is changed, they are used to increase/decrease its value.
4. Dimmer to control the backlight intensity. Turn it up to the stop in direction right to
maximize the backlight intensity. Turn it up to the stop in direction left to cancel it (no backlight).
5. Power LED shows that power is available and the device is operating. If power is on and
video signals are received from the current video input, this LED is green. If power is off or no video signal available in the current input, the LED goes out.
Warning!
Changing backlight intensity automatically and correspondingly changes the LED-
light intensity. If it is in the minimum (backlight cancelled), the LED will go out.
Page 10
Page 11
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
6. TRANSPORTATION AND STORAGE
The device shall be stored in heated space at air temperature of +5 ºС to +35 ºС (maximum values of -55 ºС to +75 ºС), at relative humidity of air not exceeding 95 % at temperature of +25 °C and content of dust, oil, moisture and aggressive admixtures in the air not exceeding the norms envisaged by GOST 12.1.005-88 for the working zone of production areas.
The device shall be transported in transport container of the manufacturer in closed transport.
Means of transport:
automobile and railway closed transport (covered wagons, universal containers)
by air (in pressurized and heated bays of airplane)
by sea (in dry service spaces).
The device shall be transported in accordance with the transport regulations in force for the particular transport.
During handling operations and transportations strictly observe the requirements of handling marks on boxes and do not allow bumps and impacts which can affect preservation and serviceability of the device.
Packed devices shall be reliably secured in vehicles.
After storage in stores or transportation at temperature below +10 ºС the devices shall be unpacked only in heated spaces after keeping them unpacked in under normal climatic conditions for12 hours.
Page 11
Page 12
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
7. WARRANTY
The manufacturer guarantees the unit complies with this manual provided that the operation, transportation and storage conditions are adhered to during the warranty period.
The unit’s warranty period expires 24 months from the date of its shipping from the manufacturer’s storehouse.
Within the warranty period, the owner is entitled for a free repair, or a replacement of a separate part, provided that the malfunction occurred through the manufacturer’s fault.
Warranty repair is provided if the unit is submitted with the manufacturer’s label and a legible serial number available on it, as well as this operating manual.
The manufacturer is not responsible and cannot guarantee the unit’s operation:
1. After the warranty period is over;
2. In case of the failure to observe the unit’s operation, transportation, storage and
installation rules and conditions;
3. If the unit is in an unmarketable condition, or has a damaged body, and other causes
beyond the manufacturer’s control;
4. If self-made electrical devices were used.
5. If there was an attempt to repair the unit by a person who is not an authorized
representative of the manufacturer.
If the owner loses this operating manual or the manufacturer’s label with a serial number, the manufacturer shall not provide their copies, and the owner shall be divested of the right for a free repair during the warranty period.
Upon the warranty expiry, the manufacturer shall facilitate the repair of the unit at the owner’s expense.
Note: in case of warranty repair, the unit’s disassembling from the installation site and its delivery to the manufacturer’s service center are done at the owner’s expense.
Visit the manufacturer’s website www.unicont.spb.ru (section “support/warranty”) to find:
forms to fill in claims,
full warranty description;
full description of the warranty service rendering procedure.
The manufacturer service center’s address and contact details:
Unicont SPb, Ltd.
Bld. 26Е Kibalchich Str., Saint Petersburg, 192174, Russia
tel.: + 7 (812) 622 23 10, +7 (812) 622 23 11
fax: +7 (812) 362 76 36
e-mail: service@unicont.spb.ru
Page 12
Page 13
Unicont SPb Ltd Operating manual MV-1504/1704/1904/2104
8. DATE OF PACKING
Marine LCD Display
name of article designation serial number
Packed Unicont SPb Ltd., Russia.
Manufacturer
according to the requirements of the current technical documentation.
post signature clarification of signature
year, month, day
9. ACCEPTANCE DETAILS
Marine LCD Display
name of article designation serial number
was manufactured and accepted in accordance with the regulatory requirements of the
state standards and applicable technical documentation, and is suitable for operation.
Quality control representative
Stamp
here signature clarification of signature
year, month, day
10. DATE OF COMMISSIONING
Marine LCD Display
name of article designation serial number
The unit has been put into operation.
Date of installation: _________________________________________
Place of installation: _________________________________________
Person in charge of installation: _________________________________________
Page 13
Loading...