Unical ALKON 24 B 60, ALKON 35 B 60 User Operating Manual

00332926 - 1st edition - 09/2008
ALKON 24 B 60 ALKON 35 B 60
USER’S OPERA TING INSTRUCTIONS
Contents
1 - SYMBOLS USED IN THIS GUIDE
When reading this guide particular care has to be given to the parts marked with the followings symbols:
NOTE! Suggestions for the user
WARNING!
Indicates a potentially dangerous situation for the product and the environment
DANGER! Indicates serious danger for your personal safety and for your life
2 - CORRECT USE OF THE APPLIANCE
The ALKON appliance has been designed utilizing today’s heating technology and in compliance with the current safety regulations. However, following an improper use, dangers could arise for the safety and life of the user or of other people, or damage could be caused to the appliance or other objects. The appliance is designed to be used in pumped hot water central heating systems and for domestic hot water production. Any other use of this appliance will be considered improper. UNICAL declines any responsibility for any damages or injuries caused by an improper use; in this case the risk is completely at the user’s responsibility . In order to use the appliance according to the scopes it was designed for it is essential to carefully follow the instructions indicated in this guide.
3 - WA TER TREA TMENT
• The hardness of the mains water supply conditions the frequency with which the heat exchanger is cleaned.
• In hard water areas where the main water can exceed 15°f total hardness, a scale reducing device is recom­mended. The choice of this device has to be made taking into consideration the water’s characteristics.
• In order to improve the resistance to lime scale, it is recommended to adjust the domestic hot water tempera­ture as near as possible to the one you really require.
• The use of a modulating room thermostat reduces the dangers of lime scale formation.
• We recommend you to check the state of cleanliness of the domestic hot water heat exchanger at the end of the first year and subsequently, on the basis of the amount of lime scale found, this period can be extended to two years.
CONTENTS
1 Symbols used in this guide ....................................................................................................................................................... 2
2 Correct use of the appliance .................................................................................................................................................... 2
3
Water treatment ......................................................................................................................................................................... 2
4
Information to be handed over to the user ............................................................................................................................... 3
5 Safety warnings ......................................................................................................................................................................... 3
6 Operating instructions ............................................................................................................................................................... 4
6.1 Control panel ...................................................................................................................................................................... 4
6.2
Check list before commissioning the boiler ...................................................................................................................... 6
6.3
Boiler operation .................................................................................................................................................................. 6
DHW production (“R” model combined with an external storage tank) ......................................................................... 6
DHW production (“C” version) ........................................................................................................................................... 6
Energizing the “pre-heat” function .................................................................................................................................... 6
CH Mode ............................................................................................................................................................................ 6
Shutting down the boiler .................................................................................................................................................... 6
6.4 Frost protection mode ........................................................................................................................................................ 6
6.5 Eliminating the faults .......................................................................................................................................................... 7
General information
L'utente deve essere istruito sull'utilizzo e sul funzionamento del proprio impianto di riscaldamento; in parti­colare:
• Consegnare all'utente le presenti istruzioni, nonché gli altri documenti relativi all'apparecchio inseriti nella
busta contenuta nell'imballo. L’utente deve custodire tale documentazione in modo da poterla avere a disposizione per ogni ulteriore consultazione.
• Informare l'utente sull'importanza delle bocchette di areazione e del sistema di scarico fumi, evidenziandone l'indispensabilità e l'assoluto divieto di modifica.
• Informare l'utente riguardo al controllo della pressione dell'acqua dell'impianto nonché sulle operazioni per il ripristino della stessa.
• Informare l'utente riguardo la regolazione corretta di temperature, centraline/termostati e radiatori per rispar­miare energia.
• Ricordare che, nel rispetto delle norme vigenti, il controllo e la manutenzione dell’apparecchio devono essere eseguiti conformemente alle prescrizioni e con le periodicità indicate dal fabbricante. L’installazione e la manutenzione devono essere effettuate in ottemperanza alle norme vigenti secondo le istruzioni del costruttore e da personale qualificato ed abilitato ai sensi di legge. Gli impianti per la produzione
di acqua calda ad uso sanitario DEVONO essere costruiti nella loro interezza con materiali conformi al D.M. 174/2004 ( rubinetterie, tubazioni, raccordi ecc...). Per personale professionalmente qualificato s'intende quello avente specifica competenza tecnica nel settore dei componenti di impianti di riscaldamento ad uso civile, produzione di acqua calda ad uso sanitario e manutenzione. Il personale dovrà avere le abilitazioni previste dalla legge vigente.
• Se l'apparecchio dovesse essere venduto o trasferito ad un altro proprietario o se si dovesse traslocare e lasciare l'apparecchio, assicurarsi sempre che il libretto accompagni l'apparecchio in modo che possa essere consultato dal nuovo proprietario e/o dall'installatore.
Nel caso di danni a persone, animali e cose derivanti dalla mancata osservanza delle istruzioni contenute nel presente manuale il costruttore non può essere considerato responsabile.
4 - INFORMAZIONI DA FORNIRE ALL ’UTENTE (A CURA DELL ’INSTALLATORE)
5 - AVVERTENZE PER LA SICUREZZA
ATTENZIONE! L’installazione, la regolazione e la manutenzione dell’apparecchio deve essere eseguita da un personale professionalmente qualificato, in conformità alle norme e disposizioni vigenti, poichè un'errata installazio­ne può causare danni a persone, animali e cose, nei confronti dei quali il costruttore non può essere considerato responsabile.
PERICOLO! Non tentare MAI di eseguire lavori di manutenzione o riparazioni della caldaia di propria iniziativa. Qualsiasi intervento deve essere eseguito da personale professionalmente qualificato, autorizzato da Unical; si raccomanda la stipula di un contratto di manutenzione. Una manutenzione carente o irregolare può compromettere la sicurezza operativa dell’apparecchio e provocare danni a persone, animali e cose per i quali il costruttore non può essere considerato responsa­bile.
Modifiche alle parti collegate all'apparecchio
Non effettuare modifiche ai seguenti elementi:
- alla caldaia
- alle linee di alimentazione gas, aria, acqua e corrente elettrica
- al condotto fumi, alla valvola di sicurezza e alla sua tubazione di scarico
- agli elementi costruttivi che influiscono sulla sicurezza operativa dell'apparecchio
Odore di gas
Qualora venisse avvertito odore di gas attenersi alle seguenti indicazioni di sicurezza:
- non azionare interruttori elettrici
- non fumare
- non far uso del telefono
- chiudere il rubinetto d'intercettazione del gas
- aerare l'ambiente dove è avvenuta la fuga di gas
- informare la società di erogazione gas oppure una ditta specializzata.
Sostanze esplosive e facilmente infiammabili
Non utilizzare o depositare materiali esplosivi o facilmente infiammabili (ad es. benzina, vernici, carta) nel locale dove è installato l'apparecchio.
User’s operating instructions
Domestic hot water temperature control
Through this knob it is possible to allow the preparation of the storage tank and to adjust the temperature of the domestic hot water:
With the pointer of the knob positioned in the range shown beside it is possible to adjust the temperature of the domestic hot water. The adjustment range is between a minimum of 25°C and a maximum of
60°C. If the rotating switch is in the position , the D.H.W. circuit is not in operation (in this case no warm water is available). If, in the mean time, the rotating switch (A) is in the position , the antifreeze function of the storage tank is activated.
F button
ATTENTION! Function not active for boilers with domestic hot water production by storage tank.
MAX
MAX
6 - OPERATING INSTRUCTIONS
6.1 - CONTROL PANEL
E = Burner On indicator led (Green) F = Not active G = Reset /chimneysweeper mode key H = Lock-out led indicator (Red) I = System temperature control/pressure gauge
Summer/winter selector + Central heating temperature control knob
By turning this knob it is possible to choose the following operating modes:
- Summer (only DHW production)
- Winter (DHW production and central hea­ting temperature control)
When the switch is in the (Summer) position the central heating mode is exclu-
ded. However, the frost protection mode remains enabled.
With the knob in the position indicated in the figure, the boiler is in the “Winter” mode, and controls the central heating hot water flow temperature. The tempe­rature can be adjusted between 30°C minimum and 80°C maximum.
A = Domestic hot water temperature control B = Summer/winter selector + Central heating temperature
control knob C = Power On indicator led (Green) D = Central heating mode indicator led
MAX
M
I
N
SERVICE:
MAX
B
CADE HGI
F
User’s operating instructions
By pressing this key for at least 3 seconds the boiler will operate at the maximum ou­tput (led D = illuminated and flashing and led E = constantly illuminated).
By briefly pressing this key again (<3 secs.),
the boiler will operate at the minimum ou­tput (both the leds D and E flashing).
By briefly pressing this key again (<3 secs.), the boiler will operate at the minimum ou­tput (both the leds D and E flashing).
The “chimneysweeper” mode will remain enabled for 15 mi­nutes. To disenable the “CHIMNEYSWEEPER” mode before this set time has elapsed, press the reset/chimneysweeper key “G” for at least 3 seconds.
System temperature control/pressure gauge
This displays:
- on the upper scale the central heating hot water flow temperature is indica­ted.
- On the lower scale the water pressure in the central heating system is indica­ted.
- If the pressure is lower then 0,7 bar, then it will be necessary to restore the correct pressure by operating the filling valve when the system is cold and the boiler not operating
Power On indicator led
This led will illuminate when the boiler is connected to the electricity supply
Central heating mode indicator led
This led will illuminate when there is a request for central heating. If simultaneously there is a request for domestic hot water production, the led will switch off.
Burner On indicator led
When this led is illuminated it indicates that the burner is fun­ctioning correctly, both in central heating request mode and in domestic hot water production mode.
Lock-out indicator led
When this led is illuminated it indicates that the bur­ner’s safety cut-off device has shut-down the boiler.
Reset key
The function of this key is to reset correct boiler ope­ration after the cut-off device has shutdown the boiler
(red led indicator illuminated)
If the cut-off device operates more than 3 times, causing boiler shutdown, do not try to reset the boiler yourself. Contact your nea­rest Unical authorized After Sales Service Centre.
Reset key with “Chimneysweeper” mode
WARNING! This operation can be carried out exclusi­vely by personnel from authorized After Sa­les Service centres. The user is NOT autho­rized to activate the following described mode.
By pressing this key the “Chimneysweeper” mode is activated. This means that the boiler will be forced to operate at the maximum (or minimum) output so as to permit the adjust­ment operations and the combustion analysis.
6.2 - CHECK LIST BEFORE COMMISSIONING THE BOILER
Before commissioning the appliance it is recommended to check the following points:
- Check that the On-Off gas valve, positioned upstream of
the boiler, is in the On position..
- Check that any On-Off valves fitted on the flow and return
pipes for servicing purposes are in the On position.
- Check that any On-Off valves fitted on the cold water inlet
for servicing purposes are in the On position.
- Check that the pressure relief valve drainage pipe is con-
nected to the sewage system.
- Check that the boiler is connected to the electrical supply;
the green indicator led (
) on the control panel must be
illuminated..
- Check the heating system pressure, indicated by the pres-
sure gauge. For correct operation the pressure should be between 0,8 and 1 bar (with the pump not running). If the pressure falls below 0,7 bar restore the correct pres­sure by regulating the filling valve when the system is cold and the boiler not operating (refer to paragraph 6.5).
User’s operating instructions
6.3 - BOILER OPERATION
Position the domestic hot water control knob (A) to the desired DHW tempera­tur
- with the knob turned at 10% to the left
= 25°C
- with the knob turned completely to the right = 60°C
Note: By adjusting the DHW temperature at a tem­perature very close to the one actually used will avoid mixing hot water with cold water, thus resulting in fuel savings and a signifi­cant reduction in lime scale formation.
In this case, the boiler will fire until the water contained in the tank has reached the desired temperature, set via the knob “A” .
When a tap or shower is turned on the appliance will provide domestic hot water at the desired temperature.
Domestic hot water production
For the operation in heating mode the knob (B) must be positioned in the range as shown in figure.
- the knob pointer in position 1 corresponds to the minimum temperature of 35°C
- the knob pointer in position 1 corresponds to the maximum temperature of 80°C
SWITCH OFF OF THE BOILER
Deactivation of heating mode By rotating the knob (B) completely to
the left the heating is deactivated, but the D.H.W. mode remains active (Summer mode).
Complete boiler shut down
If the boiler is completely shut down, the CH and DHW mode will be completely disenabled.
To completely shut down the boiler, switch off the electrical supply to the boiler (the green “Power On” led
is not illumi-
nated).
If the boiler will remain shut down for a longer period, turn the
Domestic hot water production
MAX
On/Off gas cock into the Off position and, if fitted, turn the cold water supply cock into the Off position.
In the case of long periods of inactivity of the boiler close the gas and water gate valves. Remember that the installation of this boiler, as well its maintenance, must be performed by authorised and trained personnel. All these activities have to be recorded on the log book of the installation, as per local regulations.
6.4 - ELIMINATING THE FAULTS
The boiler is fitted with a frost protection system which will operate automatically when the system temperature falls be­low 6°C: the burner is automatically fired and the pump is energized until the system’s water temperature has risen to 16°C.
If the temperature detected by the CH sensor falls below 2°C, burner operation is automatically stopped until the tempera­ture has risen to 5°C.
WARNING!
This feature will operate only if the electrical supply to the boiler is On (green Power On led illuminated). However, further frost protection can be incor­porated by using specific frost protection pro­ducts, suitable for multi-metal systems. Do not
use anti-frost products for motor vehicles because they could seriously damage the water gaskets.
If, for any reason, there is no gas or electrical supply, the above described frost protection mode will not be active.
MAX
M
I
N
MAX
User’s operating instructions
Cause:
Insufficient water pressure in the central heating system.
Elimination of the fault:
Restore the correct pressure value by regulating the boiler’s filling valve (for correct boiler operation the pressure should be between 0,8 and 1 bar). When the correct pressure value has been reached the led will switch off automatically and normal boiler operation will be restored.
DANGER! If the system has to be frequently restored please contact an authorized Unical After Sales Service Centre.
6.5 - ELIMINATING THE FAULTS
If the boiler goes into lock-out the user can reset the boiler only in the following cases:
Lock-out led illuminated and flashing
WARNING: If the boiler goes into lock-out and/or the leds continue to flash repeatedly or remain illumi­nated do not try to reset the boiler yourself. Contact your nearest Unical authorized Af­ters Sales Service Centre.
Burner lock-out led constantly illuminated
Cause:
IThe burner’s lock-out device has intervened due to:
- no gas supply (in this case check that the gas service cock is open
- presence of air in the piping (if it is a new system or after a long inactivity of the boiler).
Elimination of the fault:
Check that the gas service cock is in the On position and that the air present in the piping has been vented. Press the reset key to restore correct boiler operation.
If the cut-off device operates repeatedly (a maximum of 3 times), causing boiler shu­tdown, do not try to relight the boiler your­self. Contact your nearest Unical authorized After Sales Service Centre.
Filling cock
AG S.P.A.
46033 casteldario - mantova - italia - tel. 0376/57001 (r.a.) - fax 0376/660556
www.unical.ag - info@unical-ag.com
The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press. Also reserves the right to bring those changes that it will hold necessary to it own products or profits, without jeopardizing its essential characteristics.