The machine is delivered in a cardboard box screwed onto a wooden pallet.
A. Unpack the machine
-Cut the tightening strap with shears.
-Open the cardboard box and take the accessories’ container out.
-Make screws loose by slightly inclining the cardboard box.
-Take the machine out of the cardboard box and put it on wooden blocks.
-Remove screws and washers used for transport.
B. Install the machine and preparation of the site
- Put the machine in its final place and level it up with the help of rubber washers, as necessary.
- The machine must be placed on a horizontal surface.
- There must be a free space of 5 cm behind the machine and the ventilation holes on the top of the machine
must not be obstructed.
- A socket with a ground system and a water-supply pipe corresponding to the characteristics of the machine
are sufficient for connecting.
Set up cup racks after making adjustments.
2. HYDRAULIC CONNECTION
A water softener is necessary.
Water Intake
-Pressure ranging from 0 to 10 bar
-Connection : 3/8 gas female socket (male plug on
machine)
-Pipe with a minimum 8 mm internal diameter
-Stop valve to be set up.
Drainage
-Connection : 3/4 gas female socket (male plug on
machine)
-Pipe with a minimum 12 mm internal diameter.
- 2 -
3. ELECTRIC CONNECTION
- .None of the switches must be in ON position.
- Make sure that the voltage, frequency and power values marked on the descriptive plate of the machine are
in conformity with the electric network mains.
- Mount a plug on the end of the machine cable (plug with grounding: green/yellow wire).
. POWER CONNECTIONS
Set the machine switch to Position
.
The machine is delivered with a cable consisting of 5 numbered wires.
Make sure that the machine connection matches the available voltage network (see wiring
diagrams hereunder). Bring the necessary modifications into the supply cable and the plug located
near the electrically-driven pressurestat.
WIRING DIAGRAMS
1
4
RESISTANCE
HEATING ELEMENT
ALIMENTATION BOITIERS ELECTRONIQUES
ET TRANSFORMATEUR NEON
FEEDING ELECTRONIC BOXES
AND NEON TRANSFO R MER
BORNIER
TERMINAL PLUG
1
2
3
4 5 6
1 2 3
P1 P2 P3
4 5 6
2 3
N
1
5
4
NL1PEL3 L2
4
5
6
THERMOSTAT
SECURI TE RESISTANCE
HEATING ELEMEN T
SAFETY THERM OSTAT
PRESSOSTAT
PRESSURESTAT
6
RESISTANCE
HEATING ELEMENT
ALIMENTATION BOITIERS ELECTRONIQUES
ET TRANSFORMATEUR NEON
FEEDING ELECTRO NIC BOXES
AND NEON TRANSFOR MER
BORNIER
TERMINAL PLUG
2
3
NL1
2
3
1
PE L3 L2
4 5 6
1 2 3
P1 P2 P3
4 5 6
5
6
5
6
THERMOSTAT
SECURITE RESIST AN CE
HEATING ELEM EN T
SAFETY THERM OSTAT
PRESSOSTAT
PRESSURESTAT
4
RESISTANCE
HEATING ELEMENT
ALIMENTATION BOITIERS ELECTRONIQUES
ET TRANSFORMATEUR NEON
FEEDING ELECTRONIC BOXES
AND NEON TRAN S F O RMER
BORNIER
TERMINAL PLUG
1
2
3
4 5 6
1 2 3
P1 P2 P3
4 5 6
1
563
N
2
NL1PEL3 L2
4
5
6
THERMOSTAT
SECURITE RESI STANCE
HEATING ELEMENT
SAFETY THERMOSTAT
PRESSOSTAT
PRESSURESTAT
4
N 1 2 3
N1 L1 L2 L3
N0 1 2 3
N 1 2 3
N Ph1 Ph2 Ph3
380 / 400 / 415V TRI + N +
A : Electronic box
B : Switch
MAIN
COMMUTATOR
CABLE
CORD
N 1 2 3
N1 L1 L2 L3
N0 1 2 3
N 1 2 3
N Ph
MAIN
COMMUTATOR
CABLE
CORD
200 / 230 / 240 V MONO +
IN ALL CASES, THE GREEN/YELLOW WIRE
MUST BE EARTHED
- 3 -
N 1 2 3
N1 L1 L2 L3
N0 1 2 3
N 1 2 3
Ph1 Ph2 Ph3
MAIN
COMMUTATOR
CABLE
CORD
200 / 230 / 240V TRI +
4. STARTING-UP
4.1 FILLING THE BOILERS
- Turn on the shutoff valve.
- Plug in the machine.
- Set the charge switch to Position 1. Do not set the charge switch to
Position 2 until the boiler has been filled.
4.1a STEAM BOILER
- As soon as the machine is turned on, the filling takes place automatically.A safety is programmed, if the filling
does not occur before 3 minutes. In this special case, the electrovalve and the pump are cut off. The indicator light
blinks when steam and hot water outlets are not activated.If after 3 minutes the indicator light is still blinking :
- Check the hydraulic connection of the machine.
- Switch off and switch on the machine by setting the charge switch to Position 0 then to position 1.
The filling starts again and lasts 3 minutes.
4.1b INTERNAL BOILERS
ON/OFF SWITCH
- With the filter holder in place, press the continuous/stop key of each unit. \\
As soon as the water flows correctly from the spout (with no air), press the same key again to stop the
water.
4.2 HEATING
- When the boilers have been filled, Set the charge switch to Position 2.
- When the operating temperature of the machine is reached, the pressure-gauge must indicate a pressure of
0.9 to 1 bar (red scale).
It is better to keep the machine switched on permanently and the filter-holders inserted in machine
even when you are not making coffees.
5. CHECKS AND ADJUSTMENTS
.To get to the various adjustments, the cup rack, the rear panel or the sides must be removed.
Proceed as follows:
.CUP RACK:
Remove the grids, than
unscrew the 4 upper screws and the two
side screws. Than remove the cup rack.
.REAR PANEL(S):
Unscrew the 2 screws located inside the
machine at its back; than make the
panel(s) glide laterally.
.SIDES:
On each side, unscrew 2 screws of the
cup rack and pull-up the sid e.
- 4 -
5.1 TEMPERATURE ADJUSTMENT BY MEANS OF THE ELECTRIC
PRESSURE CONTROLLER
.The pressure controller ( pressurestat) is located at the
back..
.Dismantle the cup rack, remove the cover of the
pressure controller to get to its adjustment
screw.
-TIGHTEN to LOWER the temperature
-LOOSEN to RAISE the temperature.
.The pressure-gauge (red scale) must
indicate a pressure of between 0.9
and 1 bar which corresponds to a
temperature of 120°C.
5.2 PRESSURE-RELEASE VALVE ADJUSTMENT
RUMBA Model
The HP valve is located in the lower part at the right rear
of the machine: it is necessary to dismantle the right side.
The valve must open at about 10 bar (green scale of the
pressure gauge).
- If the valve opens ABOVE 10 bar LOOSEN
- If the valve opens BELOW 10 bar TIGHTEN
Use a pin-wrench; after the adjustment,do not forget to
block the counter nut.
TWIN RUMBA and TRI RUMBA Model
The HP valve is located in the lower part at the left rear
of the machine: it is necessary to dismantle the left side.
The valve must open at about 13 bar (green scale of the
pressure gauge).
- If the valve opens ABOVE 13 bar LOOSEN
- If the valve opens BELOW 13 bar TIGHTEN
Use a pin-wrench; after the adjustment,do not forget to
block the counter nut.
- 5 -
5.3 PUMP - PRESSURE ADJUSTMENT
In infusion, the pressure must be between 9 and 10 bar (pressure gauge - green scale)
RUMBA Model
The pump is located in the left side
and the adjustment must be done from
the same side of the machine.
.TIGHTEN to INCREASE the pressure.
.LOOSEN to DECREASE the pressure.
TWIN RUMBA and TRI RUMBA Model
The pump is located in the right side
and the adjustment must be done from
the same side of the machine.
.TIGHTEN to INCREASE the pressure.
.LOOSEN to DECREASE the pressure.
5.4 COFFEE GRINDING ADJUSTMENT
.Wait until the machine has reached the proper temperature (0.9 to 1 bar).
.The fineness of the grinding determines the time it takes for hot water to pass through the coffee.
.The passage-time is usually checked by using the 2-cup filter, with 2 doses of ground coffee.
.The average passage-time for 2 cups (6 to 7 cl. per cup) is from 30 to 35 seconds.
.If the passage-time is shorter, grind the coffee finer.
.If the passage-time is longer, grind the coffee coarser.
.For a good cup of coffee, use at least 6 gr. of ground coffee per cup.
FLUSHING INSTRUCTIONS
The unit is to be flushed prior to putting it into service, or after 24 hours of inactivity.
Dispense to the drain : - through each coffee head and water nozzle 0,5 litre of water
- through each steam nozzle some steam for 1 minute
"BEFORE PREPARING ANY BEVERAGE"
- 6 -
6. PROGRAMING OF THE DIFFERENT COFFEE QUANTITIES IN THE CUP
P5
P1P2P3P4
The keys from P1 à P4 can be programmed.
The multiple doses (1 , 2 ou 3 cups ) are calculated automatically from the programming of one
of them on each box.
Set the machine switch to Position 0.
1
Keep the key P5 pressed and put again the machine on.
2
Display of Pn then Pc and Pr by pressing several times the key P5
Pc = CALCULATED PROGRAMMING
3
Insert a filter-holder ( with coffee ) into the unit
Install cups
" P5
Display Pc
" P1 à P4
" P5
" P5
Pn = DIGITAL PROGRAMMING
4
Quick programming without coffee and/or values carried foward on other units.
" P5
" P1 à P4
" P5
" P1
" P4
ε P5
Pr = MANUAL PROGRAMMING
5
Same proceeding as in calculated programming Pc.
The manual programming doesn't calculate the other doses (1, 2 or 3 cups), only the
programed dose is modified.
Caution: any new programming ( Pn or Pc ) cancel ALL previous programed
values.
Wait until the program mode is automatically inactivated (from 10 to 15s), or switch
6
off and on again the machine.
Select the dose to be programed (2c for example)
Start the infusion cycle
Press again to stop when the amount of coffee desired is correct.
Display of the corresponding digital value ( from 00 à 99 )
Repeat operation at 3 for the other doses ( 2C for example)
Display Pn
Select the dose to be programed
Dispaly of the digital value of the selected dose
Increase the value
Reduce the value
Memorize the new value
Repeat operation at 4 for the other doses
- 7 -
6.1 2 CUPS ELECTRONIC BOXES (type d2)
Continu / Stop key
6.1a USE OF THE DOSES TO BE PROGRAMED
− 4 coffee doses and 1 manual function, Continu/Stop are available. During the infusion, it is displayed :
* 1c or 2c= 1 or 2 small cups
* 1C or 2C= 1 or 2 large cups
* C-= Continu/Stop
− At any time you can change the selection by pressing another key.
− The dosage is automatic but the infusion can be stopped manually by pressing the key Continu/Stop.
− Programing: The multiple doses being computed, only two programing are necessary (1c or 2c) and
(1C or 2C).
6.1b CONFIGURATION PARAMETERS
* dn / dtFor the automatic calculation of the multiple doses
dn = normal dosage
dt = dosage with "Torino" kit
* C0 / C1Chronometer for the infusion time
C0 = no chronometer
C1 = display of the infusion time
cc= always starts in small cups
CC = always starts in large cups
cC= keep the last selection : c or C
After switching on, the display shows the following information in order:
− The version number of the electronic memory: ex. r1
− The type of box: d3
− The active functioning parameters: ex. dn, CO, A1, CC
6.2c MODIFICATIONS OF THE CONFIGURATION PARAMETERS
− Switch the machine off (switcher 0/1)
− Press simultaneously both keys P1 and P4, and in the same time, switch again the machine on
− Press the key P4 to change the selection (ex. dn or dt)
− Press the key P5 to change function (ex. dosage dn/dt or Chrono: C0/C1)
− Switch off to leave the configuration mode or wait the automatic leaving at the end of 10s.
- 9 -
7. DAILY CLEANING AND MAINTENANCE
Coffee unit :
- Carry out 2 or 3 infusion cycles without any coffee in the filter to clean the unit and the filter-holder
joint (filter-holders not tightened)
- Wash the filter-holders and the filters in soapy water.
Overflow tray :
- Remove the overflow tray to empty it and rinse it under the tap.
Steam outlet tube :
- After each use, clean the steam tube with a wet rag and push steam push-button for a short moment to
eliminate the small amount of liquid (milk) left inside the tube.
Body :
- Clean the body of the machine using a soft cloth and alcohol for the stainless-steel parts and a nonabrasive detergent for the painted parts.
Do not forget to regenerate your water softener periodically.
ATTENTION :
Air must be able to circulate freely all around the machine. The ventilation holes located at the rear and
on the top of the machine must not be obstructed.
The machine is not to be operated without its legs.
- 10 -
Water Softener Regeneration : how ?
A - Water intake
B - Water outlet
C - Intake tap
D - Outlet tap
E - Discharge pipe
F - Regenerating pipe
G - Lid wheel
Use 1 kg of salt when the
softener is 400 mm high.
Use 2 kg of salt when the
softener is 600 mm high.
INSTRUCTIONS FOR
USE :
Install an empty vessel with
a 2-litre capacity under Pipe E.
Turn Handles C and D from
the left to the right.
Unscrew G to remove the
lid.
Insert salt.
Restore the lid to its initial
position.
Turn Handle C from the right
to the left
Let the salted water run
through Pipe F until it gets
soft.
- 11 -
Turn Handle D from the right
to the left
Water Softener Regeneration : when ?
Example :
Daily amount of used coffee : 3 kg
Number of 7-centilitre cups : 420
Daily water consumption : 30 litres
Daily number of 20-centilitre cups of tea : 150
Daily water consumption : 30 litres.
Conclusion : - Total daily water consumption is 60 litres
- Water hardness is 30°TH.
See 30°Column and line 60 of Table hereunder.
-DV 50 Water softener must be regenerated every 2 weeks.
-CN 97 Water softener must be regenerated every 5 weeks.
CN 97 Model Height : 600 mm Diam. : 185 mm Resin : 16 litres Salt : 2 kg
Water hardness °TH20°25°30°40°50°60°80°
Softened water
CN 97 Model
110171614131110 7202
1,5 15 111099775303
2209876554404
2,5 257665443505
3306554432606
3,5 355444332707
4404443322808
4,5 454333222909
5503333221
6603322221
6,5 653222211
7702222111
7,5 752222111
8802222111
Coffee
in kg
Daily consumption
Water
in litres
2500 2350 2100 1800 1600 1400 1000
36343026222014101
1200 1100 1000900760700500
20°25°30°40°50°60°80°Water hardness °TH
Water in
litres
NUMBER OF
WEEKS BETWEEN 2
REGENERATING
TREATMENTS
ACCORDING TO FLOW
CAPAC. & WATER °TH.
Daily
consumption
Softened water
DV 50 Model
Coffee
in kg
DV 50 Model Height : 400 mm Diam. : 185 mmResin : 8 litres Salt : 1 kg
- 12 -
8. CONNECTION TO A COMPUTER SYSTEM
A. GENERALITIES
Connection to a computer system (Hartwall, Walla, Remenco, ...)
The coffee machine informs the computer (in real time) about the number of cups of coffee and tea
(made with temporized hot water). The computer is in charge of the management of the collected
coffee machine data.
Each barman has got a coded badge that gives him permission to use the coffee machine and directly
charge the served drinks.
B. MACHINE PREPARATION
Prior to being connected to a computer system, a coffee machine of the RUMBA range must be modified
as follows:
1. Ref. 45026 and 45027 (with memory dated 22/07/97)
The following equipment is also supplied:
2. An interface box that records impulses coming from units and hot water outlets and transmit
them to the computer
3. The cables connecting the interface to the coffee machine
4. A key switch to enter in programing mode.
Relea se of cont rols
Impulse Transfert
BADGE
Temporized hot water
Access
to
Controls
INTERFACE
Computer System
Data Transfer
- 13 -
TROUBLE SHOOTING
VERY IMPORTANT
BEFORE TAKING ANY ACTION MAKE SURE THAT ALL THE ADJUSTMENTS ARE CORRECT.
1. TEMPERATURE 120°C
STEAM PRESSURE 0,9 to 1 bar (14 PSI)
2. INFUSION PRESSURE 9 to 10 bar (140 PSI)
High pressure valve opening : over 13 bar (188 PSI)
3. WATER SUPPLY PRESSURE 0 bar to 6 bar (0 PSI to 90 PSI)
If the machine "sucks" water directly from an external reservoir, check the water level in the
reservoir and the non-return valve and filter fixed at the end of the inlet pipe.
4. PRECAUTIONS TO BE TAKEN
Switch off the machine before any action on the electric circuits.
Cool the machine and make the pressures down before any action on the hydraulic circuit.
- 14 -
9. DISPLAYED FAILURES
Push button 1
Push button 2
Push button 3
Push button 4
Push button 5
Fuse
Time
See on
§ 9.1
See on
§ 9.2
See on
§ 9.3a > 105 sec
Metering + Time
Dosage Metering
Short circuit Metering
Opened Metering
- 15 -
See on
§ 9.3b > 105 sec
See on
§ 9.3b
See on
§ 9.3c
9.1 PROBLEMS IN CONNECTION WITH THE ELECTRONIC BOXES'S CONTROL
BUTTONS
If it is displayed P1, P2 ... or P5, this means that the corresponding key is in short-circuit and can't be used any more.
Remedy:
- Check that the front is not deformed
- Change the electronic box
9.2 FUSE PROBLEMS
Display: F
F- is displayed when the fuse located at the back of the electronic box is "cut out".
The fuse can be reached from the upper part of the machine after removing the cup warmer.
-
If the fuse is "all right"If the fuse is "cut out"
Check the fuse-holder
Clean fuse / fuse-holder contact points
Check the box conn ections:
Do not invert wires
(valve and motor-pump wires)
The cause must be determined, prior to fuse
replacement.
Possible causes:
- The valve coil of the unit is short circuited
- The motor-pump coil or R.C circuit
is short-circuited
∗
- The motor-pump or valve outlets
of the electronic box are short circuited (inside the box)
- Cables are short-circuited
- Fuse failure.
- Replace faulty elements
- Replace the fuse
- 16 -
9.3 DOSAGE PROBLEMS
9.3a 105-second safety system of the coffee unit
Thanks to such a safety system, the maximum infusion time is reduced and ranges from 1 minute to 45 seconds. As
a result, the infusion process automatically stops, if the dosing device no longer works or if the flow capacity is
insufficient so that the motor-pump and the valve of the unit are better protected.
When the safety system is on,
The flow of the water going through the coffee filter is insufficient.
The infusion time corresponding to the programed dose is more than 105 seconds.
The pump is faulty
Check:
- The pressure
- Power supply:
* cables
* condenser
- The mechanical state of
the motor-pump:
* filter
* coupling
t is displayed.
One of the water passage holes
is clogged.
Check the hydraulic circuit:
- Nozzle of dosing device
- Unit nozzle
- Unit filter
- Unit valve
- Coffee filters
The coffee grind is too fine:
- Use a coarser grind.
- The spout
- 17 -
9.3b Metering safety system
During the infusion process,
impulses to the unit electronic box for 5 seconds.
If the metering interruption is only temporary, the infusion cycle will stop as soon as the number of metered
impulses matches the number of programed impulses.
Obviously the obtained dose will be heavier.
If the metering interruption is permanent, the infusion will stop automatically 105 seconds after
the cycle has started and
Or stop manually by pressing the Continu/Stop key.Display of
Display ofct or cd. The dosing device has stopped transmitting
cd is displayed. This means that the dosing device has been no longer transmitting
ct is displayed.
cd
impulses to the unit electronic box for more than 5 seconds.
Start a coffee cycle.
Check the control LED located on the dosing device.
It does not flashIt flashes
The water does not run
through the spout
The hydraulic circuit is
blocked
Check:
- There is water above
the dosing device
- Coffee filters are clean
- The grind is not too
fine
- The device nozzle is
all right
- The unit valve is
opened
- The unit nozzle
- The unit filter.
The water runs through
the spout
The dosing device no longer
works
Check:
- The device cables
(power supply + 9V)
- The free rotary move ment of the turbine
- The magnets drowned
in the turbine are clean
- The dosing device
(outgoing signal)
Replace the dosing device, as
necessary.
- Either there is no more
problem and it all nor mally works.
- Or the outgoing signal
wire of the device is dis connected.
(terminal: 32-out)
- 18 -
9.3c Dosing device safety system
Display of
cc
The 9V power supply of the dosing
device is short circuited:
Terminal 30 (+) is earthed
To use the unit, press the Continu/Stop key
Check the cables and the connector of the dosing device
Replace the dosing device, as necessary.
Display of
co
The 9V power supply circuit of the
dosing device is opened:
Terminal 30 (+) or earth
are disconnected.
- 19 -
10. OTHER FAILURES
10.1 HYDRAULIC PROBLEMS OF THE COFFEE UNIT
10.1a Doses lighter than initially set
The obtained doses are lighter than initially set
There is a leak located just after the dosing device
The decompression way of the unit
valve leaks during the infusion
process
Check flaps
Repeat dose programing
10.1b Dripping outside infusion periods
Water goes through the unit or the decompression pipe outside
The 3-way valve is opened as a result of the
too highly set expansion pressure
(>13 bar)
One of the connections located
after the dosing device outlet leaks
Check waterproofness
Replace gaskets
infusion periods
The valve flaps
are faulty
Set the high pressure valve opening
at 13 bar
The pump pressure must be set at 10 bar
- 20 -
Check the flaps
Replace the flap
core, as necessary.
10.1c An insufficient infusion pressure
The infusion pressure is lower than 10 bar
Set the pump as indicated on (
§ 5.3 )
Setting operations are unsuccessful
The pump is faultyThe motor-pump isThe motor-pump is no
110 V mono
200 V mono
220 V mono - 380V tri + N
230 V mono - 400V tri + N
240 V mono - 415V tri + N
KW
Mono seulement
Mono only
1,7
2,3
2,7
3
3,2
2,3 / 3,5
2,7 / 4,3
3 / 4,7
3,2 / 5,1
3,5
4,3
4,7
5,1
- 24 -
PlECES DETACHEES POUR MODELE RUMBA
SPARE PARTS FOR RUMBA MODEL
PLANCHES
PLATES
100MODELE RUMBARUMBA MODEL
110MODELE TWIN / TRI RUMBATWIN / TRI RUMBA MODEL
115COTES RUMBARUMBA SIDES
200JUPETTECOVER
210FACE AVANTFRONT
230VIDANGE ET ENTREE EAUDRAIN AND WATER FEEDING
240GROUPE MAESTRO MAESTRO UNIT
241GROUPE CREMACREMA UNIT
242GROUPE MAESTRO CREMAMAESTRO CREMA UNIT
250MANOMETREMANOMETER
260ELECTROVANNE 3 VOIESELECTROVALVE 3 WAYS
281PORTE FILTRE 1 TASSE1 CUP FILTER
282PORTE FILTRE 2 TASSES2 CUP FILTER
283PORTE FILTRE 3 TASSES3 CUP FILTER
310BOITIER ELECTRONIQUE CAFECOFFEE ELECTRONIC BOX
420ENTREE EAUWATER FEEDING
450ELECTROVANNE DE REMPLISSAGEFEEDING ELECTROVALVE
451ELECTROVANNE DE REMPLISSAGE 1GR 1 UNIT FEEDING ELECTROVALVE
452ENTREE EAU ET SOUPAPE HP 1GR1 UNIT WATER FEEDING AND HP VALVE
455SOUPAPE HAUTE PRESSIONHIGH PRESSURE VALVE
460DOSEUR D'EAUWATER DOSER
470SOUPAPE BPVALVE LP
530ELECTROVANNES EAU CHAUDE VAPEUR HOT WATER STEAM ELECTROVALVES
535SORTIE VAPEUR TEFLONTEFLON STEAM SPOUT
540CHAUDIERE INJECTIONBOILER
552CIRCUIT HYDRAULIQUE 2 GROUPES2 UNITS HYDRAULIC CIRCUIT
553CIRCUIT HYDRAULIQUE 2 GROUPES3 UNITS HYDRAULIC CIRCUIT
554CIRCUIT HYDRAULIQUE 2 GROUPES4 UNITS HYDRAULIC CIRCUIT
560PRESSOSTAT ELECTRIQUEELECTRIC PRESSURESTAT
570BORNIERTREMINAL BOARD
572BORNIER POUR RUMBA 1 GR1 UNIT TERMINAL BOARD
580PIEDSFEET
590MOTEUR POMPE AVEC POMPE NUERTPUMP MOTOR WITH NUERT PUMP
591MOTEUR POMPE RUMBA 1GR1 UNIT PUMP MOTOR
592MOTEUR POMPE AVEC POMPE PROCON PUMP MOTOR WITH PROCON PUMP
595POMPE ROTATIVE 200 L/HPUMP
596POMPE ROTATIVE 100 L/HPUMP
655ELECTROVANNE 2 VOIESELECTROVALVE 2 WAYS
690RACCORD DE VIDANGEDRAIN CONNECTION
730COMMUTATEURSWlTCH
770ELEMENT CHAUFFANTHEATING ELEMENT
772THERMOSTAT DE SECURITESAFETY THERMOSTAT
975CAPPUCCINATORECAPPUCCINATORE
1010REFERENCE DE CABLES RUMBARUMBA WIRES REFERENCES
1020REFERENCE DE CABLES TWIN RUMBATWIN RUMBA WIRES REFERENCES
1030REFERENCE DE CABLES TRI RUMBATRI RUMBA WIRES REFERENCES
UNIC
0
16/04/2004
PLANCHE/PLATE : 10
REPREF
1DV3230COTE GAUCHE INOXSTAINLESS STEEL LEFT SIDE
2FR7046ENJOLIVEUR JOUE DROITORNAMENTAL RIGHT SIDE
3DV3202CHAUFFE TASSES 1 GROUPECUP WARMER
4DV3205VERRIERE LG 232 CUP RACK
5DV3240COTE DROIT INOXSTAINLESS STEEL RIGHT SIDE
6DV3250CALANDRE RUMBA 1GR UPPER FRONT PANEL
7FR7045ENJOLIVEUR JOUE GAUCHEORNAMENTAL LEFT SIDE
846041BANDEAU ADHESIF RUMBASTICKER RUMBA
945006BOITE ELECTRONIQUE d2 115VELECTRONIC BOX 115V d2
945007BOITE ELECTRONIQUE d3 115VELECTRONIC BOX 115V d3
945022BOITE ELECTRONIQUE d2 230VELECTRONIC BOX 230V d2
945023BOITE ELECTRONIQUE d3 230VELECTRONIC BOX 230V d3
1043405INTERRUPTEUR UNIP EAU CHAUDEHOT WATER SWITCH
1143406INTERRUPTEUR VAPEURSTEAM SWITCH
12DV-163JUPETTE PLASTIQUE MOD COVER PLASTIC
13DV3331GRILLE DE BASSINE 1GR 1 UNIT OVERFLOW TRAY GRID
DESIGNATION
14FR7041ENJOLIVEUR BASSINE DROITORNAMENTAL RIGHT OVERFLOW TRAY
15DV3301BAS BASSINE 1GR 1 UNIT OVERFLOW TRAY
16FR7040ENJOLIVEUR BASSINE GAUCHEORNAMENTAL LEFT OVERFLOW TRAY
17DV3221DEVANT RUMBA PANEL - FRONT - LOWER
18DV3211CHEMISE 1GRSTAINLESS STEEL CASING
.
.
13456
2
7
8
9
10
11
18
12
13
14
151617
03/04
RUMBA
100
UNIC
0
16/04/2004
PLANCHE/PLATE : 11
REPREF
1DV3230COTE GAUCHE INOXSTAINLESS STEEL LEFT SIDE
2FR7046ENJOLIVEUR JOUE DROITORNAMENTAL RIGHT SIDE
3DV3202CHAUFFE TASSES 2 GROUPES2 UNITS CUP WARMER
4DV3204VERRIERE 2 GROUPES 2 UNITS CUP RACK
4DV3206VERRIERE 3 GROUPES 3 UNITS CUP RACK
5DV3240COTE DROIT INOXSTAINLESS STEEL RIGHT SIDE
6DV3260CALANDRE RUMBA 2GR 2 UNITS UPPER FRONT PANEL
7MI-83BOBINE EV O.D.E 220V 60HZ UL ELECTROVALVE COIL 220V-60HZ
7MI-90BOBINE EV O.D.E 110V60 UL ELECTROVALVE COIL 110V60Hz
8ID-57RONDELLE DE FREIN WASHER
9ID-56ECROU D'ELECTROVANNE NUT
10PI-45ELECTROVANNE 3V 220V50HZ WHOLE ELECTROVALVE 220V 50HZ
10PI-45AELECTROV.3V 110V60Hz UL WHOLE ELECTROVALVE 110V 60HZ
10PI-45BELECTROVANNE 3V. 220V60HZ UL WHOLE ELECTROVALVE 220V-60HZ
10PI-45XELECTROVANNE 3V D:1 SANS BOBINELECTROVALVE 3W WITHOUT COIL
DESIGNATION
9
8
7
10
6
5
4
3
01/04
2
1
ELECTROVANNE 3 VOIES
ELECTROVALVE 3 WAYS
260
UNIC
27/05/2004
PLANCHE/PLATE : 281
REPREF
1PC-58BEC UNE TASSE CHROME 1 CUP SPOUT
2DV7050CACHE SORTIE BECSPOUT HIDDER
3DV4010PROLONGATEUR SORTIE BECSPOUT SPACER
433102COUPE NUEFILTER HOLDER BODY
533104CARRE POIGNEE COUPE STEEL SQUARE FOR HANDLE
633105POIGNEE DE COUPE HANDLE
7CF-199RONDELLE PLATE DE 8WASHER
8RR-83RONDELLE GROVER 8 WASHER
9CN-51VIS TCHC M8 X 20SCREW M8 X 20
1033106BOUCHON POIGNEE DE COUPETAP FOR HANDLE
11PA-85ARESSORT DE COUPE DIAM:1.3 FILTER SPRING DIAM:1.3
12PA-84FILTRE UNE TASSE 1 CUP FILTER
1333131COUPE COMPLETE 1T1 CUP FILT. HOLDER
DESIGNATION
12
11
10
5
6
7
8
9
13
4
3
2
1
03/04
PORTE FILTRE 1 TASSE
1 CUP FILTE R HOLDER
281
UNIC
2
27/05/2004
PLANCHE/PLATE : 28
REPREF
1PC-25BEC 2 TASSES CHROME 2 CUP SPOUT
2DV7050CACHE SORTIE BECSPOUT HIDDER
3DV4010PROLONGATEUR SORTIE BECSPOUT SPACER
433102COUPE NUEFILTER HOLDER BODY
533104CARRE POIGNEE COUPE STEEL SQUARE FOR HANDLE
633105POIGNEE DE COUPE HANDLE
7CF-199RONDELLE PLATE DE 8WASHER
8RR-83RONDELLE GROVER 8 WASHER
9CN-51VIS TCHC M8 X 20SCREW M8 X 20
1033106BOUCHON POIGNEE DE COUPETAP FOR HANDLE
11PA-85ARESSORT DE COUPE DIAM:1.3 FILTER SPRING DIAM:1.3
12PH-73FILTRE DEUX TASSES 2 CUP FILTER
1333132COUPE COMPLETE 2T2 CUP FILT. HOLDER
DESIGNATION
12
11
5
4
3
6
7
8
9
2
1
10
13
03/04
PORTE FILTRE 2 TASSES
2 CUPS FILTER HOLDER
282
UNIC
3
27/05/2004
PLANCHE/PLATE : 28
REPREF
1PH-34BEC 3 TASSES CHROME 3 CUP SPOUT
2DV7050CACHE SORTIE BECSPOUT HIDDER
3DV4010PROLONGATEUR SORTIE BECSPOUT SPACER
433102COUPE NUEFILTER HOLDER BODY
533104CARRE POIGNEE COUPE STEEL SQUARE FOR HANDLE
633105POIGNEE DE COUPE HANDLE
7CF-199RONDELLE PLATE DE 8WASHER
8RR-83RONDELLE GROVER 8 WASHER
9CN-51VIS TCHC M8 X 20SCREW M8 X 20
1033106BOUCHON POIGNEE DE COUPETAP FOR HANDLE
11PA-85ARESSORT DE COUPE DIAM:1.3 FILTER SPRING DIAM:1.3
12PA-38FILTRE TROIS TASSES 3 CUP FILTER
13CN-175VIS TC M3x5 INOX SCREW M3 X 5
1433133COUPE COMPLETE 3T AVEC CAPTEUR3 CUP FILT. HOLDER WITH SENSOR
9DO-19PLOT APB 20-20 SILENTBLOC
10C-3VIS TH M6 X 10 INOX SCREW M 6 X 10
1
2
3
4
7
5
6
04/04
8
9
10
MOTEUR POMPE AVEC POMPE PROCON
PUMP MOTEUR WITH PROCON PUMP
592
UNIC
A
5
.
16/04/2004
PLANCHE/PLATE : 59
.
REPREFDESIGNATIONDESIGNATION
1CN-347ARACCORD 3/8 - 3/8 FITTING 3/8 - 3/8
237236RESSORT SORTIE OUTLET SPRING
337240VALVE BY-PASS OPEN BY-PASS VALVE
437239AXE BY-PASS BY-PASS PLUNGER
537238JOINT TORIQUEGASKET
637234JOINT PLATGASKET
737237RESSORT BY-PASS SPRING
837233RACCORD DE REGLAGE NUT M10
937235VIS DE REGLAGE SCREW
10CN-825COLLIER ACCOUPL.MOTEUR POMPE COLLAR OF PUMP MOTOR GANGING
1137210JOINT ACCOUPLEMENT POMPEGANGING RING
1237211
1337212KIT ACCOUPLEMENTGANGING RING KIT
MORTISSEUR ACCOUPLEMENT POMPEGASKET
11
12
1
2
13
37220 POMPE N U ERT COMPLETE
37220 WHOLE PU MP NU ERT
POMP E ROTATIVE SANS FILTRE 200L/H
03/04
PUMP
364
589
7
595
10
UNIC
6
.
16/04/2004
PLANCHE/PLATE : 59
.
REPREFDESIGNATIONDESIGNATION
1CN-347ARACCORD 3/8 - 3/8 FITTING 3/8 - 3/8
237236RESSORT SORTIE OUTLET SPRING
337240VALVE BY-PASS OPEN BY-PASS VALVE
437239AXE BY-PASS BY-PASS PLUNGER
537238JOINT TORIQUEGASKET
637234JOINT PLATGASKET
737237RESSORT BY-PASS SPRING
837233RACCORD DE REGLAGE NUT M10
937235VIS DE REGLAGE SCREW
10CN-825COLLIER ACCOUPL.MOTEUR POMPE COLLAR OF PUMP MOTOR GANGING
1
2
10
37260 POMPE N U ERT COMPLETE
37260 WHOLE PU MP NU ERT
4CN-245CBOBINE EV 2V 220-60/208-50 EV COIL 2W 220-60/208-50
5ED-26ECROU DE SERRAGE POUR VANNE MAIDEN NUT
6ED-25JOINT TORIQUE POUR E.V. ELECTRO VALVE JOINT
7CN-245HCORPS DEPHASEUR EV 2 VOIES PLUNGER FOR CN-631 OR CN-245
8ED-24RONDELLE RESSORT POUR VANNE SPRING WASHER
9CN-245JRESSORT ELECTROVANNE 2 VOIES SOLENOID SPRING 1 WAY/ADJ
10CN-245ACLAPET POUR ELECTROVANNE SOLENOID PISTON - 1 WAY\ADJ
11CN-245KCORPS ELECTROV. 2 V. REGLABLE ELECTROV. BODY ADJUSTABLE
11CN-245LCORPS ELECTROVANNE NON REGL, ELECTROV. BODY WITHOUT ADJUST
11CN-245MENSEMBLE VIS DE REGLAGE SCREW KIT
12CN-245WELECTROVANNE 2 V. SANS BOBINEELECTROVALVE 2W WITHOUT COIL
12CN-631WELECTROVANN 2V REG SANS BOBINEELECTROVAL 2W ADJ WITHOUT COIL
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.