Ungo ProSecurity K20, RK20, S100, S670, SR7000 User Manual

...
Ungo ProSecurity
Ungo ProSecurity
SAA474U
K20
Remote Keyless Entry System
(2) 4-Button Remote Transmitters (SAA474U)
Anti-Code Grabbing Technology
On-Board Relays for Door Locks and Dome Light Supervision
Driver’s Door Priority Unlock Output
On-Board Parking Light Flash Relay
Hyper Blue LED
(2) Auxiliary Outputs
Comfort Closure
Horn Honk Output
SAA474U
RK20
Remote Start / Keyless Entry System
(2) 4-Button Remote Transmitters (SAA474U)
Anti-Code Grabbing Technology
On-Board Relays for Remote Start with Anti-Grind Circuit
Intelli-Tach RPM Detection Circuit
D2D (Data-to-Data) for XPress Kits Modules
Built-in Diesel Wait-to-Start Timer
Built-in Turbo Timer
Rear Window Defroster Output
On-Board Parking Light Flash Relay
(1) Auxiliary Output
Comfort Closure
Horn Honk Output
ProSecurity Programmer Compatible
S100
Security / Keyless Entry System
(2) 4-Button Remote Transmitters (SAA474U)
Anti-Code Grabbing Technology
Dual Stage Impact Sensor
On-Board Parking Light Flash Relay
Hyper Blue LED
Multiple Tone Siren
(2) Auxiliary Inputs
Dome Light Supervision Output
Driver’s Door Priority Compatible
ProSecurity Programmer Compatible
SAA474U
SAA474U
SAA477U
S670
2-Way Security / Keyless Entry System
(1) 2-Way Remote Transmitter (SAA477U)
(1) 4-Button Remote Transmitter (SAA474U)
Anti-Code Grabbing Technology
On-Board Dual Stage Impact Sensor
On-Board Relays for Door Locks and Dome Light Super­vision
On-Board Starter Disable Relay
Hyper Blue LED
Multiple Tone Siren
(3) Auxiliary Inputs
Driver’s Door Priority Compatible
Horn Honk Output
123
Ungo ProSecurity
SAA477U
SAA474U
SR7000
2-Way Security / Remote Start / Keyless Entry System
(1) 2-Way LCD Remote Transmitter (SAA477U)
(1) 4-Button Remote Transmitter (SAA474U)
Anti-Code Grabbing Technology
Compact Satellite Relay Pack for Remote Start with Anti-Grind Circuit
Intelli-Tach RPM Detection
D2D (Data-to-Data) for XPress Kits Modules
Built-in Diesel Wait-to-Start Timer
Built-in Turbo Timer
Rear Window Defroster Output
Dual Stage Impact Sensor
On-Board Parking Light Flash Relay
Hyper Blue LED
Multiple Tone Siren
(4) Auxiliary Outputs
Dome Light Supervision Output
Driver’s Door Priority Unlock Compatible
Comfort Closure
Dedicated Horn Honk Output
ProSecurity Programmer Compatible
SAA7101U
SR9000
1-Mile Range 2-Way Security / Remote Start / Keyless Entry System
(1) 2-Way LCD Remote Transmitter (SAA7701U)
SDC (Secure Digital Communication) Capable of 1-Mile Range
Anti-Code Grabbing Technology
Compact Satellite Relay Pack for Remote Start with Anti-Grind Circuit
Intelli-Tach RPM Detection
D2D (Data-to-Data) for XPress Kits Modules
Built-in Diesel Wait-to-Start Timer
Built-in Turbo Timer
Rear Window Defroster Output
Dual Stage Impact Sensor
On-Board Parking Light Flash Relay
Hyper Blue LED
Multiple Tone Siren
(4) Auxiliary Outputs
Dome Light Supervision Output
Driver’s Door Priority Unlock Compatible
Comfort Closure
Dedicated Horn Honk Output
ProSecurity Programmer Compatible
124
Ungo ProSecurity
Ungo Feature Descriptions
SDC (Secure Digital Communication)
In order to achieve a reliable 1-mile of range from the SR9000, Clarion has implemented Spread Spectrum Technology Secure Digital Communication. Spread Spectrum Technology takes a signal (in the case of the SR9000, a rolling code that tells the system what to do) and spreads the codes over a wide range of frequencies. The advantage of this is that because the signal is so spread out, it becomes more resistant to interference, and helps to guarantee the signal is received and decoded.
Ungo Spread Spectrum Technology operates at 900Mhz, further improving its resistance to interfer­ence.
Anti-Code Grabbing Technology (a.k.a. Code Hopping)
The receiver and remotes use a mathematical formula called an algorithm to change their code each time the remote is used. This technology has been developed to increase the security of the unit. The control unit knows what the next codes should be. This helps to keep the remote “in sync” with the control unit even if you use the remote control out of range of the vehicle.
Anti-Grind Circuitry
Whenever the vehicle is remote started, advanced anti-grind circuitry prevents the starter from engaging, even if the key is turned to the start position. This prevents damage to the starter motor if the key is turned to the start position during remote start opera­tion.
Gasoline or Diesel Vehicle Compatible
ProSecurity remote start systems can be installed into either gasoline or diesel vehicles.
Built-in Wait-to-Start Timer
Diesel vehicles need adequate time to warm up the glow plugs prior to starting. When the remote start is activated, the wait-to-start timer will allow the glow plugs to properly warm up before engaging the starter circuit. This feature prevents damage to the motor and glow plugs during remote start operation.
Comfort Closure
If programmed ON, the door lock output will activate the Comfort Closure output for 20 seconds. This output will begin 200mS after the final door lock output has completed regardless of the door lock program­ming. This feature is designed to integrate with vehicle’s that can close the power windows and
sunroof by holding the key in the driver’s door lock position, and will operate on both single input systems and two pulse dead bolt systems.
Dome Light Supervision Output
The dome light will illuminate for 30 seconds each time the system is disarmed using the remote control. This is useful for seeing inside the vehicle at night prior to entering it.
Dual Stage Impact Sensor
A sensor mounted in the vehicle’s interior that is designed to detect impact(s) to the vehicle and/or vehicle’s glass. Depending on the strength of the impact, the sensor can determine whether it’s an accidental contact or an actual violation attempt.
Event History Diagnostics
ProSecurity systems can provide notification that the alarm had been previous triggered and what zone. The status LED will indicate which zone was involved by flashing in a sequence. The system will retain this information until the next time the ignition key is turned ON.
False Alarm Prevention
It prevents annoying repetitive sequences due to faulty door pin switches or environmental conditions, such as thunder, jackhammers, airport noise, etc.
Hyper Blue LED
A blue LED (light emitting diode) mounted at a discretion­ary location inside the vehicle. It is used to indicate the status of your system.
(IDR) Individual Remote Recognition
Individual Remote Recognition makes it possible to program different settings for each remote that is used with the system. Then, whenever a specific remote is used, the system will recall the settings assigned to that remote. IDR lets up to four users of the system have different settings that meet their specific needs. It is almost like having four separate alarms in your vehicle, one for each user.
Keyless Entry
Allows for easy entry or exiting of the vehicle without fumbling around for your keys. Keyless entry may require additional parts and labor.
Over and Under Rev Protection
The remote start system monitors the engine speed and will automatically shut the engine off if the RPMs rise above or fall below the programmed levels. This feature prevents damage to the motor due to fuel delivery system failures or other problems, which may cause the engine to race.
125
Ungo ProSecurity
Programmable Override Sequence
ProSecurity systems can be programmed to respond to one to five pulses of the Valet/Override switch to disarm the system.
Progressive Door Unlock
For added security, the ProSecurity system can be configured to unlock the driver’s door only, leaving the remaining doors locked. Pressing the UNLOCK button an additional time will unlock the remaining doors. This option may require additional parts and labor.
ProSecurity Power Up
The ProSecurity systems will store its current state of non-volatile memory. If the power is lost and then reconnected the system will recall the stored state from memory. This means if the unit is in Valet mode and the battery is disconnected for any reason, when the battery is reconnected the unit will still be in Valet mode.
ProSecurity Starter Disable
An automatic switch controlled by your system that prevents the vehicle’s starter from cranking whenever the system is armed. The vehicle is never prevented from cranking when the system is disarmed, in Valet mode, or if the starter interrupt switch itself fails.
Rear Defroster Activation
During remote start operation, the rear defroster can be activated. This option may require additional parts and labor.
REV (Remote Enabled Valet)
REV allows access to entering and exiting Valet mode without having to disclose the location of the Valet/Override button. The security systems will not arm, even with the remote, but all convenience func­tions (door locks, trunk release, etc.) will still continue to work normally.
stage impact sensor.
Selectable Ignition Controlled Door Locks
When the ignition is turned ON, the doors will lock within 3 seconds and unlock when the ignition is turned OFF. Ignition controlled lock and unlock are independent features and can be programmed separately
Selectable Siren Duration and Tones
The duration of the siren can be programmed to either 30 or 90 seconds. Some states have laws regulating how long a security system can sound. The multi-tone sirens included with ProSecurity systems can be easily modified to select desired tones or single tone.
Short Run Timer / Turbo Timer Mode
Short Run Timer / Turbo Timer mode keeps the engine running after arriving at your destination for a programmed period of time allowing the engine lubricants to circuit before shutting down the engine.
Intelli-Tach RPM Detection
Intelli-Tach gives the installer the performance of a hard wired tach wire, with the convenience of voltage sensing. It’s far superior to any voltage sensing feature you’ve tried before.
Intelli-Tach monitors the cranking voltage of the vehicle using a very fast micro controller and an analog-to-digital converter. The microprocessor “saves” the base voltage as a reference. When Intelli-Tach “sees” the slightest uptick in voltage indicating that the alternator is charging the battery, the starter motor shuts off instantly.
Tachometer or Voltage Sensing
ProSecurity remote start systems either use a tachom­eter signal or sense the voltage of the vehicle during remote start activation. These signals inform the remote start system that the vehicle has successfully started and is running.
Remote Panic
If you are threatened in or near your vehicle, you can attract attention by triggering the system with your remote control. Just press and “PANIC” or “LOCK” button for two seconds, and you’ll enter the panic mode. The siren will sound and the parking lights will flash for the programmed duration or until “PANIC” or “LOCK” button is pressed again.
Remote Silent Arm/Disarm Capability
The siren chirps upon Arm or Disarm can be temporar­ily eliminated for that one operation only. The Arm/Disarm chirps can be turned off permanently, if desired by entering the programming mode or using a ProSecurity Programmer. The sire chirps will also be eliminated during the warn-away trigger of the dual
126
Trunk/Hatch Release Output
The system’s auxiliary output can be programmed to operate a factory power release for the vehicle’s trunk/hatch. If the factory release is not power activated, an optional trunk release solenoid can often be added. This output will then disable/ignore the dual stage impact sensor as you load or unload the vehicle.
D2D (Data-to-Data)
The RK20 and SR7000 have the ability to interface with XK modules through the D2D port. The advantage of using D2D interface is that there is less wiring involved in the installation. Check the XK module installation guide to determine which wires are not needed and which options are available.
Ungo ProSecurity
Obtaining Optimal Range
Mounting the Extended Range Antenna
1. Clean the mounting area on the windshield with a quality glass cleaner or alcohol to remove any dirt or residue.
2. Plug the receiver/antenna cable into the receiver/antenna.
3. Mount the receiver/antenna vertically using the supplied double-sided tape.
4. Route the receiver/antenna cable to the control module and plug it into the four-pin antenna connector.
IMPORTANT:
To achieve the best possible range, DO NOT leave
the antenna cable bundled up tightly underneath the dash. Try to extend the cable to its full length during installation.
DO NOT mount the control module to close to the
vehicle’s body control module and/or electronic control modules.
Mounting the Standard Antenna
1. Route the antenna as high as possible, extending the cable to its full length.
2. Secure the antenna cable in place with cable ties. IMPORTANT:
To achieve the best possible range, DO NOT leave
the antenna cable bundled up tightly underneath the dash. Try to extend the cable to its full length during installation.
DO NOT mount the control module to close to the
vehicle’s body control module and/or electronic control modules.
Mounting the Control Unit
Do not mount or secure the control unit to close to
the vehicle’s body control module and/or electronic control modules.
Do not mount or secure the control unit to close to
sources of heat, such as the heater core and/or air ducts.
Ground the control unit to a clean, paint-free sheet
metal location using a factory bolt that DOES NOT have any vehicle components grounds attached to it. A screw should only be used when in conjunction with a two-sided lock washer. Under dash brackets and door sheet metal are not acceptable ground points.
It is recommended that all security components be
grounded at the same location.
Turning OFF the Anti-Code Grabbing Technology (a.k.a. Code Hopping)
Although this is a feature designed to prevent the remote transmitters from being cloned and re-transmitted to the control unit, it is virtually impossible to do. “Code Grab­bers” have a very limited range, usually required to be within 5 feet of the remote transmitter while the button is being depressed. By turning off the Anti-Code Grabbing feature, it can increase the receiving/transmitting range by 30-35%.
Refer to the “System Features Menu” for the feature number and programming instructions.
Double Stacking (2) CR2016 Batteries
The CR2032 3-volt micro lithium coin cell battery inside the SAA474U (4-button) remote transmitter can be substituted with (2) CR2016 3-volt batteries. This can increase the range between 65-75% depending on the surroundings.
Procedure:
1. Insert a small flat head screwdriver into the notch on the bottom of the SAA474U remote transmitter.
2. Gently twist the screwdriver to spreading apart the two halves of the remote transmitter.
3. Open up the remote transmitter exposing the CR2032 battery and slide it out.
4. Slide (2) CR2016 batteries into the battery holder with the “+” facing upwards. (It may be easier to slide one battery in at a time. With the first battery in place, slide the second battery between the PC board and battery.)
5. Prior to closing the two halves of the remote transmit­ter, verify the batteries are installed correctly by pressing any of the buttons. The green LED indicator should illuminate while a button is depressed. If the LED does not illuminate, double-check the direction of the batteries. The “+” should be facing upwards matching the “+” on the battery retaining clip.
6. Snap together the two halves of the remote transmit­ter.
Obtaining a Tachometer Refer­ence Signal
The tachometer reference signal is an essential signal for the safe operation of a remote start system. The signal informs the remote start module that the vehicle has successfully started and is running. It can also deter­mine whether the vehicle is idling at a safe RPM level. In the event the vehicle’s idle is racing or below safer operation level, the remote start module will shut down.
To test for a tachometer wire, a multi-meter capable of testing AC voltage must be used. The tachometer wire
127
Ungo ProSecurity
will show between 1V and 6V AC. In multi-coil systems, the system can learn individual coil wires. Individual coil wires in a multi-coil system will register lower amounts of AC voltage. Also, if necessary, the system can use a fuel injector control wire for engine speed sensing. Common locations for a tachometer wire are at the ignition coil, back of the gauge cluster, engine computers, and automatic transmission computers.
How to Find a Tachometer Wire with a Multimeter
1. Set the multimeter to ACV or AC voltage (12V or 20V is fine)
2. Attach the (-) probe of the meter to chassis ground.
3. Start the vehicle and allow it to reach its normal idle speed.
4. Probe the wire you suspect of being the tachometer wire with the red probe of the meter.
5. If it’s the correct wire the meter will read between 1V and 6V.
Multi-Coil Systems
1. Examine the individual coils and determine which wires are common on each coil. (Example: 2002 Chevy Pick-up: Each coil has 4 wires, three common wires on each coil and the 4th wire changes.)
2. The “different” colored wire can be used for the tachometer reference signal for the remote start module. (Only one coil wire is necessary.)
3. Teach the tachometer reference signal to the remote start module.
It is highly recommended to solder this connection, due to the heat generated inside the engine bay. Using t-taps or scotch-locks are likely to fail due to heat.
Fuel Injection Wire
1. Examine the individual fuel injectors and determine which wire(s) are common on each fuel injector.
2. The “different” colored wire can be used for the tachometer reference signal for the remote start module. (Only one fuel injector wire is necessary.)
3. Teach the tachometer reference signal to the remote start module.
It is highly recommended to solder this connection, due to the heat generated inside the engine bay. Using t-taps or scotch-locks are likely to fail due to heat.
128
Tachometer Reference Options
Tachless
If programmed to the voltage sense setting, the unit will crank the starter for a preset timed duration. Once the starter has been engaged, the system will check the voltage level to verify the engine is running.
When using tachless operation, it is essential to deter­mine the correct crank time to prevent damage to the starter. It may take several remote start activations to determine the crank time.
Some vehicles have many accessories, which are turned on during remote start activation. In these vehicles, the variations of voltage between the engine off and the vehicle running is very slight and the remote start module may “think” the vehicle has not started. This can cause the remote start module to shut down after the vehicle has been started. If this is the case, the Voltage Check Level must be set to the LOW position.
Voltage sensing is not recommended in areas that experience extreme cold temperatures. The resistance in the vehicle’s wiring increases which can cause intermit­tent remote start reliability.
Passive Anti-Theft Systems
Immobilizer (a.k.a. Transponder)
The Immobilizer uses an antenna ring around the ignition cylinder to energize a small transponder chip hidden in the ignition key. When the ignition is turned on, the chip is energized and the antenna ring sends the code to the Immobilizer control unit. The vehicle will only start if the code matches the one programmed into the vehicle.
Passkey/VATS
The Passkey/VATS system consists of four parts: the Passkey cylinder, the ignition switch, the instrument cluster panel (ICP), and the power train control module (PCM). The system requires that the key cylinder be mechanically turned using a key. When the key cylinder is properly turned, it generates a resistance code (R-code), which is sent to the IPC. The vehicle will only start if the R-code matches the key and ignition cylinder.
Passlock 2
The Passlock 2 system must see the correct resistance code at the correct time. When the ignition system is turned to the crank position, the “Bulb Check” wire is switched to ground. This starts a time window during which the instrument cluster panel (IPC) analyzes the resistance code (R-code). If the R-code is valid and is received in the proper window of time, the IPC sends a code via data bus to the PCM to enable the fuel injection
system. If the key cylinder itself is pulled out or damaged, it will not generate the resistance code and vehicle will not run.
Passkey 3
The Immobilizer uses an antenna ring around the ignition cylinder to energize a small transponder chip hidden in the ignition key. When the ignition is turned on, the chip is energized and the antenna rings sends the code to the Immobilizer control unit. If the code is incorrect the vehicle will not start.
PATS
Passive Anti-Theft System (PATS) uses a specially programmed key to start the vehicle, similar to the Immobilizer. It uses an antenna ring around the ignition cylinder to energize a small transponder chip hidden in the ignition key. When the ignition is turned on, the chip is energized and the antenna ring sends the code to the PATS control unit. If the code is incorrect the vehicle will not start.
Ungo ProSecurity
129
Ungo ProSecurity
K10: Keyless Entry System
Replacement Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Arm/Disarm/Panic 2 Silent Mode/Remote Override/Trunk Release Red/White 3 Remote Engine Start or Other Accessory White/Blue 4 Arm Only 5 Disarm Only 6 Panic Only 7 Auto-Learn Single Button Arm/Disarm Configuration 8 Auto-Learn Standard Configuration 9 Delete All Remotes
K20: Keyless Entry System
Replacement Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Auto-Learn 2 Arm (Lock) Only 3 Disarm (Unlock) Only 4 Channel 2 Red/White 5 Channel 3 White/Blue 6 Arm/Disarm/Panic 7 Panic Only 8 Delete All Remotes
Transmitter/Receiver Learn Routine
Ungo ProSecurity come with either one or two transmitters that have been programmed to the receiver. Use the following learn routine to add transmitters to the system or to change button assignments if desired.
The Valet/Override button must be in working order and plugged into the blue port on the Ungo ProSecurity system. There is a basic sequence to remember whenever programming a system: Door, Key, Choose, Transmitter and Release.
Procedure:
1. Open a door.
2. Turn the ignition On
3. Press and release the Valet/Override switch the number of times necessary to access the desired channel, then press the switch once more and Hold it. The siren (or horn) with chirp and the LED will blink the number of times corresponding to the channel that has been accessed.
K10, K20, RK1, RS10, S100, S400, S660, S670, SR1000, SR5000, SR6000, SR9000
4. While holding the Valet/Override switch, press the button on that you would like to control the selected receiver channel. The unit will chirp to confirm that code has been successfully programmed. It is not possible to teach a remote button to the system more than once.
5. Once the code is learned, the Valet/Override switch can be released.
RK20, SR7000
4. While holding the Valet/Override switch, press the “LOCK” button on the remote control. The siren chirps to confirm that the code has been successfully programmed or the selected feature has been reset. It is not possible to teach a remote control button to the system more than once.
5. Once the code is learned, or the feature reset, the Valet/Override switch can be released.
130
Ungo ProSecurity
RS10: Remote Start/Keyless System
Replacement Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Auto-Learn 2 Lock/Unlock 3 Channel 2 Red/White 4 Remote Engine Stat 5 Turbo Timer / Short Run 6 Timer Mode 7 Rear Defogger Control 8 Delete All Remotes
RK1: Remote Start/Keyless System
Replacement Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Auto-Learn 2 Lock, Panic On / Panic Off 3 Unlock, Panic Off 4 Silent Mode/Channel 2 Red/White 5 Remote Start 6 Channel 4 Violet/Black 7 Turbo Timer / Short Run 8 Timer Mode
9 Lock/Unlock/Panic 10 Panic Only 11 Delete All Remotes
RK20: Remote Start/Keyless System
Replacement Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Auto-Learn
2 Delete All Remotes
3 Reset Features: This resets all the features of the system
to the factory default settings
4 Intelli-Tach Reset: Deletes all previously learned values for
Intelli-Tach, and on the next remote start sequence the unit will being the Intelli-Tach initialization.
131
Ungo ProSecurity
S100/S400: Security/Keyless System
Replacement Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Arm/Disarm/Panic
2 Silent Mode/Remote Override/Trunk Release Red/White
3 Remote Engine Start or Other Accessory White/Blue
4 Arm Only
5 Disarm Only
6 Panic Only
7 Auto-Learn Standard Configuration
8 Auto-Learn Single Button Arm/Disarm Configuration
9 Delete All Remotes
S660: 2-Way Security/Keyless System
Replacement 4-Button Remote Transmitter: SAA474U Replacement Battery: CR2032 Replacement LCD Remote Transmitter: SAA477U Replacement Battery: AAA
Ch. Number Function Wire Color
1 Auto Learn Standard Configuration
2 Arm Only
3 Disarm Only
4 Silent Mode/Remote Override/Trunk Release Red/White
5 No Function
6 Channel 4 Violet/Black
7 Channel 5 White/Black
8 No Function
9 No Function 10 Arm/Disarm/Panic 11 Panic Only 12 Delete All Transmitters
S670: 2-Way Security/Keyless System
Replacement 4-Button Remote Transmitter: SAA474U Replacement Battery: CR2032 Replacement LCD Remote Transmitter: SAA477U Replacement Battery: AAA
Ch. Number Function Wire Color
1 Arm/Disarm/Panic
2 Channel 2 Red/White
3 Channel 3 White/Blue
4 Channel 4 Violet/Black
5 Arm Only
6 Disarm Only
7 Panic Only
8 Auto-Learn (4-Button and LCD 2-Way Transmitter)
9 Auto-Learn (3-Button Optional Transmitter) 10 Delete All Transmitters
132
Ungo ProSecurity
SR1000: Remote Stat/Security/Keyless System
Replacement 4-Button Remote Transmitter: SAA474U Replacement Battery: CR2032
Ch. Number Function Wire Color
1 Auto-Learn Standard Configuration
2 Arm Only
3 Disarm Only
4 Silent Mode/Remote Override/Trunk Release Red/White
5 Remote Start
6 Channel 4 Violet/Black
7 Channel 5 White/Black
8 Turbo Timer / Short Run
9 Timer Mode 10 Arm/Disarm/Panic 11 Panic Only 12 Delete All Remotes
SR6000: 2-Way Remote Stat/Security/Keyless System
Replacement 4-Button Remote Transmitter: SAA474U Replacement Battery: CR2032 Replacement LCD Remote Transmitter: SAA477U Replacement Battery: AAA
Ch. Number Function Wire Color
1 Auto-Learn Standard Configuration
2 Arm Only
3 Disarm Only
4 Silent Mode/Remote Override/Trunk Release Red/White
5 Remote Start
6 Channel 4 Violet/Black
7 Channel 5 White/Black
8 Turbo Timer / Short Run
9 Timer Mode 10 Arm/Disarm/Panic 11 Panic Only 12 Delete All Remotes
SR5000: 2-Way Remote Stat/Security/Keyless System
Replacement 4-Button Remote Transmitter: SAA474U Replacement Battery: CR2032 Replacement LCD Remote Transmitter: SAA477U Replacement Battery: AAA
Ch. Number Function Wire Color
1 Arm/Disarm/Panic
2 Silent Mode/Remote Override/Trunk Release Red/White
3 Remote Start
4 Second Unlock or Other Accessory Violet/Black
5 Arm Only
6 Disarm Only
7 Panic Only
8 Auto-Learn Standard Configuration
9 Auto-Learn Single Button Configuration 10 Delete All Remotes
133
Ungo ProSecurity
SR7000: 2-Way Security/Remote Start/Keyless Entry
Replacement 4-Button Remote Transmitter: SAA474U Replacement Battery: CR2032 Replacement LCD Remote Transmitter: SAA477U Replacement Battery: AAA
Ch. Number Function Wire Color
1 Auto-Learn Standard Configuration
2 Delete Remotes: This feature will erase all remotes from the
memory of the system. NOTE: Does not reset the programmed features of the system or reset the Intelli-Tach setting.
3 Reset Features: This resets all the features of the system
to the factory default settings. NOTE: Does not delete the remotes from the system or reset the Intelli-Tach setting.
4 Intelli-Tach Reset
: Deletes all previously learned values for Intelli-Tach, and on the next remote start sequence the unit will begin Intelli-Tach initialization. NOTE: The "ZAP" feature on the ProSecurity Programmer does not reset the Intelli-Tach setting.
SR9000: 2-Way Security/Remote Start/Keyless Entry
Replacement LCD Remote Transmitter: SAA7701U Replacement Battery: AAA
Ch. Number Function Wire Color
1 Auto-Learn Standard Configuration 2 Arm Only 3 Disarm Only 4 Silent Mode/Remote Override/Trunk Release Red/White 5 Remote Start 6 Channel 4 Violet/Black 7 Channel 5 White/Black 8 Channel 6
9 Turbo Timer / Short Run 10 Timer Mode 11 Arm/Disarm/Panic 12 Panic Only 13 Rear Defogger 14 Delete All Transmitters
134
Ungo ProSecutity
K10: Keyless Entry System
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1 Active Arming Passive Arming 2 Chirps ON Chirps OFF 3 Ignition Controlled Door Lock ON Ignition Controlled Door Lock OFF 4 Ignition Controlled Door Unlock ON Ignition Controlled Door Unlock OFF 5 Active Locking Passive Locking 6 Ignition Controlled Domelight ON Ignition Controlled Domelight OFF 7 0.8 Second Door Lock Pulses 3.5 Second Door Lock Pulses 8 Double Pulse Unlock OFF Double Pulse Unlock ON
9 Security Features ON Securit
y Features OFF
10 Code Hopping ON Code Hopping OFF
K20: Keyless Entry System
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1 Ignition Controlled Door Lock ON Ignition Controlled Door Lock OFF 2 Ignition Controlled Door Unlock ON Ignition Controlled Door Unlock OFF 3 Ignition Controlled Domelight ON Ignition Controlled Domelight OFF 4 0.8 Second Door Lock Pulses 3.5 Second Door Lock Pulses 5 Double Pulse Unlock OFF Double Pulse Unlock ON 6 Double Pulse Lock OFF Double Pulse Lock ON 7 Comfort Closure OFF Comfort Closure ON 8 Code Hopping ON Code
Hopping OFF
Module Programming Routine
The Module Programming Routine dictates how the unit operates. Due to the number of steps, they have been broken up into different menus. It is possible to access and change any of the feature settings using the Valet/Override switch. However, this process can be greatly simplified by using the ProSecurity Programmer. Any of the settings can be changed and then assigned to a particular remote, up to four, a feature called individual remote recognition. Each time that particular remote is used to disarm the system, the assigned feature settings will be recalled. Individual recogni­tion is only possible when programming the unit via the ProSecurity Programmer.
If the system was programmed using the ProSecurity Programmer, the learn routine may be locked. If the siren generates one long chirp when attempting to program the unit, the Module Programming Routine is locked and must be unlocked using the ProSecurity Programmer.
Procedure:
1. Open a door.
2. Turn the ignition On, then back Off.
3. Press and HOLD the Valet/Override switch: (The Valet/Override switch must be plugged into the blue port.) After three seconds the siren will chirp once indicating entry to Menu #1. If this is the menu you wish to access, release the button and go on to Step 4. If the button is not released, you will jump to Menu #2 and the siren will chirp twice. If the button is not released, you will jump to Menu #3 and the siren will chirp three times. Once you have selected the desired menu, release the Valet/Override button and then proceed to Step 4.
4. Press and release the Valet/Override switch the number of times corresponding to the feature you wish to change. Then press the switch once more and HOLD it. The siren will chirp the number of times equal to the step you have accessed.
5. While holding the Valet/Override switch, you can toggle the feature on or off using the remote. Pressing the “LOCK” button will select the one chirp setting. Pressing the “UNLOCK” button will select the two chirp setting.
6. Release the Valet/Override switch.
135
Ungo ProSecurity
RK1: Remote Start/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Mode
Passive Mode
2
Chirps ON
Chirps OFF
3
Ignition Lock ON
Ignition Lock OFF
4
Ignition Unlock ON
Ignition Unlock OFF
5
Active Locking
Passive Locking
6
Panic with Ignition ON
Panic with Ignition OFF
7
Door Lock Pulse Duration 0.8 Seconds
Door Lock Pulse Duration 3.5 Seconds
8
Double Unlock Pulse OFF
Double Unlock Pulse ON
9
Channel 2 Delayed Validity
Channel 2 Latched (2), Latch Reset with
Ignition (3), 30-Second Timed (4)
10
Factory Alarm Disarm w/Channel 2 ON
Factory Alarm Disarm w/Channel 2 OFF
11
Security Features ON
Security Features OFF
12
Code Hopping ON
Code Hopping OFF
13
Channel 4 Validity
Channel 4 Latched (2), Latch Reset with
Ignition (3), 30-Second Timed (4)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
Factory default settings are indicated in
bold
in the following feature tables.
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Check ON
Engine Check OFF
2
Tachometer Engine Check
Voltage Engine Check
3
12 Minute Run Time (1)
24 Minutes (2), 60 Minutes (3) Run Time
4
Flashing Parking Light Output
Constant Parking Light Output
5
Cranking Time 0.6 sec. (1)
Crank Time: 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5)
6
Voltage Level High Check
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) Seconds
7 Activation Pulse: 1 (1)
Activation Pulses: 2 (2)
, 3 (3)
8
2nd Ignition Output
2nd Accessory Output
9
Acc. State During Wait to Start OFF
Acc. State During Wait to Start ON
10
2nd Status Output Normal
Rear Defogger Latched (2), Rear Defogger
Pulse (3)
11
Anti-Grind ON
Anti-Grind OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
136
Ungo ProSecurity
RS10: Remote Start/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Check ON
Engine Checking OFF
2
Tachometer Checking Type
Voltage Checking Type
3
12 Minutes Run Time (1)*
24 Minutes (2), 60 Minutes (3) Run Time
4
Flashing Parking Light Output
Constant Parking Light Output
5
Crank Time 0.6 sec. (1)
Crank Time: 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5)
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Check High Level
Voltage Check Low Level
7
Short Run (Turbo Timer): 1 (1) min.
Short Run (Turbo Timer): 3 (2), 5 (3), 10 (4)
Minutes
8 Activation Pulse: 1 (1)
Activation Pulses: 2 (2),
3 (3)
9
Ign/Acc Output: Ignition
Ign/Acc Output: Accessory
10
Acc. State During Wait to Start: OFF
Acc. State During Wait to Start: ON
11
2nd Status Output: Normal (1)
Rear Defogger Latched (2), Pulsed (3)
12
Diesel Timer Wait to Start Input (1)
Time 15 (2), 30 (3), 45 (4) Seconds
13
Run Time (Timer Mode) 12 min. (1)
3 (2), 6 (3), 9 (4) Minutes
14
Door Lock Pulse Duration 0.8 Sec (1)
3.5 (2), 0.4 (3) Seconds
15
Unlock Output 1 Pulse
Unlock Output 2 Pulses
16
Lock Output 1 Pulse
Lock Output 2 Pulses
17
Ignition Unlock ON
Ignition Unlock OFF
18
Ignition Lock ON
Ignition Lock OFF
19
Factory Alarm Disarm with Unlock
Before Unlock (2), Remote Engine Start
Only (3)
20
Factory Alarm Disarm 1 Pulse
2 Pulses
21 Comfort Closure ON
OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
RK20: Remote Start/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Horn Honk Pulses OFF (1)
20mS (2), 30mS (3), 40mS (4), 50mS (5)
2
Ignition Lock OFF
Ignition Lock ON
3
Ignition Unlock OFF
Ignition Unlock ON
4
Door Lock Pulse Duration 0.8 Seconds
3.5 (2), 0.4 (3) Seconds
5
Unlock Output 1 Pulse
Unlock Output 2 Pulses
6
Lock Output 1 Pulse
Lock Output 2 Pulses
7
Factory Alarm Disarm w/Unlock (1)
Before Unlock (2), Remote Start Only (3)
8
Factory Alarm Disarm 1 Pulse
2 Pulses
9
Comfort Closure OFF (1)
Version 1 (2), Version 2 (3)
10
Panic Mode ON
Panic Mode OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
137
Ungo ProSecurity
RK20: Remote Start/Keyless Entry System
continued
Factory default settings are indicated in
bold
in the following feature tables.
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Intelli-Tach (1)
Voltage (2), OFF (3), Tachometer (4)
2
12 Minute Run Time (1)
24 Minutes (2), 60 Minutes (3) Run Time
3
Constant Parking Light Output
Flashing Parking Light Output
4
Cranking Time 0.6 sec. (1)
Crank Time: 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5)
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) Seconds
5 Activation Pulse: 1 (1)
Activation Pulses: 2 (2)
, 3 (3)
6
2nd Ignition Output
2nd Accessory Output
7
Acc. State During Wait to Start OFF
Acc. State During Wait to Start ON
8
2nd Status Output Normal
Rear Defogger Latched (2), Rear Defogger
Pulse (3)
9
Anti-Grind ON
Anti-Grind OFF
10
Wait to Start Timer: 0 sec (1)
15 (2), 30 (3), 45 (3) seconds
S100/S400: Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Controlled Door Locks ON
Ignition Control Door Locks OFF
4
Active Locking OFF
Passive Locking ON
5
Panic with Ignition ON
No Panic with Ignition ON
6
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
7
Forced Passive Arming ON
Forced Passive Arming OFF
8 Automatic Engine Disable ON
Automatic Engine Disable OFF
9
Armed When Driving
Anti-Carjacking System
10
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
Factory default settings are indicated in
bold
in the following feature tables.
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren
Horn Honk
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Channel 3: Validity
Channel 3: Latched/Latched (2), Reset with
ignition(3), 30-Second Timed (4), Second
Unlock Output (5)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
138
Ungo ProSecurity
S660: 2-Way Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Door Locks ON
Ignition Door Locks OFF
4
Ignition Door Unlocks ON
Ignition Door Unlocks OFF
5
Active Locking Only
Passive Locking
6
Panic with Ignition ON
Panic with Ignition OFF
7
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
8
Forced Passive Arming ON
Forced Passive Arming OFF
9 Automatic Engine Disable ON
Automatic Engine Disable OFF
10
Armed When Driving
Anti-Carjacking System
11
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
Factory default settings are indicated in
bold
in the following feature tables.
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren Output Constant
Siren Output Pulsed
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Channel 4 Validity
Channel 4: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec. Timed (5), 90-Sec. Timed (6)
11
Channel 5 Validity
Channel 5: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec. Timed (5), 90-Sec. Timed (6)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
S670: 2-Way Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Door Locks ON
Ignition Door Locks OFF
4
Active Locking Only
Passive Locking
5
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
6
Double Unlock Pulse OFF
Double Unlock Pulse ON
7
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
8
Door Trigger Error Chirp ON
Door Trigger Error Chirp OFF
9
Lock Pulse Single
Lock Pulse Double
10
Comfort Closure OFF
Comfort Closure ON
139
Ungo ProSecurity
SR1000: Remote Start/Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Locks ON
Ignition Locks OFF
4
Ignition Unlock ON
Ignition Unlock OFF
5
Active Locking Only
Passive Locking
6
Panic With Ignition ON
No Panic With Ignition
7
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
8
Forced Passive Arming ON
Forced Passive Arming OFF
9 Automatic Engine Disable ON
Automatic Engine Disable OFF
10
Armed While Driving ON
Armed While Driving OFF
11
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren Output Constant
Siren Output Pulsed
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Channel 4 Validity
Channel 4: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec. Timed (5), 90-Sec. Timed (6)
11
Channel 5 Validity
Channel 5: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec. Timed (5), 90-Sec. Timed (6)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking ON
Engine Checking OFF
2
Engine Checking Tach
Engine Checking Voltage
3
Run Time: 12 Minutes (1)
Run Time: 24 Min (2), 60 Min. (3)
4
Parking Lights Flashing
Parking Lights Constant
5
Crank Time: 0.6 Sec (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Check: High
Voltage Check: Low
7
Short Run/Turbo Timer: 1 Min (1)
3 (2), 5 (3), 10 (4) Minutes
8 Activation Pulse Count: 1 (1)
Activation Pulse Count: 2 (2)
9
2nd Ign/ACC Output: Ignition
Accessory
10
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
11
2nd Status Output: Normal
Rear Defogger: Latched 10 Min (2),
Pulsed (3)
12
Anti-Grind: ON
Anti-Grind: OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
140
Ungo ProSecurity
SR5000: 2-Way Remote Start/Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Door Locks ON
Ignition Door Locks OFF
4
Active Locking Only
Passive Locking
5
Panic With Ignition ON
No Panic With Ignition
6
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
7
Forced Passive Arming ON
Forced Passive Arming OFF
8 Automatic Engine Disable ON
Automatic Engine Disable OFF
9
Armed While Driving ON
Armed While Driving OFF
10
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren Output Constant
Siren Output Pulsed
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Channel 4 Validity
Channel 4: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), Second Unlock Output (5)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking ON
Engine Checking OFF
2
Engine Checking Tach
Engine Checking Voltage
3
Run Time: 12 Minutes (1)
Run Time: 24 Min (2), 60 Min. (3)
4
Parking Lights Flashing
Parking Lights Constant
5
Crank Time: 0.6 Sec (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Check: High
Voltage Check: Low
7
Auxiliary Output: Factory Disarm
Special Accessory
8
Status Output
Factory Re-arm Output
9
Anti-Grind: ON
Anti-Grind: OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
141
Ungo ProSecurity
SR6000: Remote Start/Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Locks ON
Ignition Locks OFF
4
Ignition Unlock ON
Ignition Unlock OFF
5
Active Locking Only
Passive Locking
6
Panic With Ignition ON
No Panic With Ignition
7
0.8 Second Door Lock Pulse
3.5 Second Door Lock Pulse
8
Forced Passive Arming ON
Forced Passive Arming OFF
9 Automatic Engine Disable ON
Automatic Engine Disable OFF
10
Armed While Driving ON
Armed While Driving OFF
11
Anti-Code Grabbing ON
Anti-Code Grabbing OFF
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Siren Output Constant
Siren Output Pulsed
2
30-Second Siren Duration
60-Second Siren Duration
3
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
4
Progress Door Trigger
Instant Door Trigger
5
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
6
Open Zone Bypass Notice: ON
Open Zone Bypass Notice: OFF
7
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
8
Single Unlock Pulse
Double Unlock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Channel 4 Validity
Channel 4: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec. Timed (5), 90-Sec. Timed (6)
11
Channel 5 Validity
Channel 5: Latched/Latched (2), Reset with
Ignition (3), 30-Sec. Timed (4), 60-Sec. Timed (5), 90-Sec. Timed (6)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking ON
Engine Checking OFF
2
Engine Checking Tach
Engine Checking Voltage
3
Run Time: 12 Minutes (1)
Run Time: 24 Min (2), 60 Min. (3)
4
Parking Lights Flashing
Parking Lights Constant
5
Crank Time: 0.6 Sec (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Check: High
Voltage Check: Low
7
Short Run/Turbo Timer: 1 Min (1)
3 (2), 5 (3), 10 (4) Minutes
8 Activation Pulse Count: 1 (1)
Activation Pulse Count: 2 (2)
9
2nd Ign/ACC Output: Ignition
Accessory
10
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
11
2nd Status Output: Normal
Rear Defogger: Latched 10 Min (2),
Pulsed (3)
12
Anti-Grind: ON
Anti-Grind: OFF
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
142
Ungo ProSecurity
SR7000: 2-Way Remote Start/Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Lock ON
Ignition Lock OFF
4
Ignition Unlock ON
Ignition Unlock OFF
5
Active Locking Only
Passive Locking
6
Panic with Ignition ON
No Panic with Ignition ON
7
0.8 Sec. Door Lock Pulse (1)
3.4 (2), 0.4 (3) Seconds
8
Forced Passive Arming ON
Forced Passive Arming OFF
9 Automatic Engine Disable ON
Automatic Engine Disable OFF
10
Armed When Driving ON
Armed When Driving OFF
11
Code Hopping ON
Code Hopping OFF
12
Horn Output Pulsed
Constant
13
Horn Function Full Alarm Only (1)
Siren Function - Chirp Length 20mS (2),
30mS (3), 40mS (4), 50mS (5)
14 Comfort Closure ON
Comfort Closure OFF (2),
Comfort Closure OFF (3)
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
30-Second Siren Duration
60-Second Siren Duration
2
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
3
Progress Door Trigger
Instant Door Trigger
4
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
5
Door Trigger Error Chirp ON
Door Trigger Error Chirp OFF
6
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
7
Single Unlock Pulse
Double Unlock Pulse
8
Single Lock Pulse
Double Lock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Factory Alarm Disarm with Unlock (1)
Before Unlock (2), Remote Start Only (3)
11 Factory Alarm Disarm 1 Pulse 2 Pulses 12 Auxiliary 1 Validity (1) Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4), 60-Sec. Timed (5),
90-Sec. Timed (6) 13 Auxiliary 1 Linking None (1) Arm (2), Disarm (3), Remote Start (4) 14 Auxiliary 2 Validity (1) Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4) 15 Auxiliary 2 Linking None (1) Arm (2), Disarm (3), Remote Start (4) 16 Auxiliary 3 Validit
y (1) Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4) 17 Auxiliary 3 Linking None (1) Arm (2), Disarm (3), Remote Start (4)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
143
Ungo ProSecurity
SR7000: 2-Way Remote Start/Security/Keyless Entry System
(continued)
Factory default settings are indicated in
bold
in the following feature tables.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking: Intelli-Tach
Voltage (2), OFF (3), Tachometer (4)
2
Run Time: 12 Minutes (1)
Run Time: 24 Min (2), 60 Min. (3)
3
Parking Lights Flashing
Parking Lights Constant
4
Crank Time: 0.6 Sec (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
5
Activation Pulse 1
Activation Pulse 2
6
2nd Ign/Acc Output: Ignition
Accessory
7
Acc. State During Wait-to-Start OFF
ON
8
2nd Status Output: Normal
Rear Defogger: Latch 10 Min. (2),
Pulse (3)
9
Anti-Grind ON
OFF
10
Diesel Timer: Wait-to-Start Input
Timed 15 (2), 30 (3), 45 (4) Seconds
11 Timer Mode Run Time: 12 Min 3 (2), 6 (3), 9 (4) Minutes 12
Timer Mode: Timed Starts
Temp. Starts
13
Turbo Timer/Short Run: 1 Min (1)
3 (2), 5 (3), 10 (4) Minutes
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
SR9000: 2-Way Remote Start/Security/Keyless Entry System
Factory default settings are indicated in
bold
in the following feature tables.
MENU #1
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Active Arming
Passive Arming
2
Chirps ON
Chirps OFF
3
Ignition Lock ON
Ignition Lock OFF
4
Ignition Unlock ON
Ignition Unlock OFF
5
Active Locking Only
Passive Locking
6
Panic with Ignition ON
No Panic with Ignition ON
7
0.8 Sec. Door Lock Pulse (1)
3.4 (2), 0.4 (3) Seconds
8
Forced Passive Arming ON
Forced Passive Arming OFF
9 Automatic Engine Disable ON
Automatic Engine Disable OFF
10
Armed When Driving ON
Armed When Driving OFF
11
Code Hopping ON
Code Hopping OFF
12
Horn Output Pulsed
Constant
13
Horn Function Full Alarm Only (1)
Siren Function - Chirp Length 20mS (2),
30mS (3), 40mS (4), 50mS (5) 14 Comfort Closure ON
Comfort Closure OFF (2),
Comfort Closure OFF (3)
144
SR9000: 2-Way Remote Start/Security/Keyless Entry System
(continued)
MENU #2
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
30-Second Siren Duration
60-Second Siren Duration
2
False Alarm Prevention Circuitry ON
False Alarm Prevention Circuitry OFF
3
Progress Door Trigger
Instant Door Trigger
4
Override Switch Input: 1 Pulse
Override Switch Input: 2-5 Pulses
5
Door Trigger Error Chirp ON
Door Trigger Error Chirp OFF
6
Ignition Controlled Dome Light ON
Ignition Controlled Dome Light OFF
7
Single Unlock Pulse
Double Unlock Pulse
8
Single Lock Pulse
Double Lock Pulse
9
Factory Disarm with Channel 2 ON
Factory Disarm with Channel 2 OFF
10
Factory Alarm Disarm with Unlock (1)
Before Unlock (2), Remote Start Only (3)
11
Factory Alarm Disarm 1 Pulse
2 Pulses
12
Auxiliary 1 Validity (1)
Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4) 13
Auxiliary 1 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
14
Auxiliary 2 Validity (1)
Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4) 15
Auxiliary 2 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
16
Auxiliary 3 Validity (1)
Latched (2), Latch Reset with Ignition (3),
30-Sec. Timed (4) 17
Auxiliary 3 Linking None (1)
Arm (2), Disarm (3), Remote Start (4)
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
Factory default settings are indicated in
bold
in the following feature tables.
MENU #3
Feature Default LED ON Setting LED OFF Setting
Number (Press "LOCK" Button) (Press "UNLOCK" Button)
1
Engine Checking ON
Engine Checking OFF
2
Engine Checking Tach
Engine Checking Voltage
3
Run Time: 12 Min. (1)
Run Time: 24 (2), 60 (3) Min.
4
Parking Lights Flashing
Parking Lights Constant
5
Crank Time: 0.6 sec. (1)
0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5), 1.6 (6),
1.8 (7), 2.0 (8), 4.0 (9)
6
Voltage Checking: High
Voltage Checking: Low
7
Short Run/Turbo: 1 Min. (1)
3 (2), 5 (3), 10 (4) Minutes
8 Activation Pulse Count 1 (1)
Activation Pulse Count 2 (2)
9
2nd Ign/Acc Output: Ignition
Accessory
10
Acc. State During Wait-to-Start: OFF
ON
11
2nd Status Output: Normal (1)
Rear Defogger: Latched 10 Min. (2)
Pulse (3)
12
Anti-Grind: ON
Anti-Grind: OFF
13
Diesel Timer Wait-to-Start Input (1)
Timed 15 (2), 30 (3), 45 (4) Seconds
14
Timer Mode- Timed Starts
Temperature Starts
15
Run Time: 12 Min. (1)
3 (2), 6 (3), 9 (4) Minutes
* NOTE: The numbers in parentheses indicate the number of times the LED will flash.
Ungo ProSecurity
145
Ungo ProSecurity
Valet Mode
To Enter or Exit Valet mode with the Valet/Override Switch:
Procedure:
1. Turn the ignition key ON and then OFF
2. At anytime during the next 10 seconds, press and release the Valet/Override switch. Now the status LED will glow constantly if you have entered Valet mode, and goes out if you have exited Valet mode.
To Enter or Exit Valet mode with the remote transmitter:
Procedure:
1. Open any door.
2. Press the “LOCK” button on the transmitter.
3. Press the “UNLOCK” button on the transmitter.
4. Press the “LOCK” button on the transmitter. Now the status LED will glow constantly if you have entered Valet mode, and goes out if you have exited Valet mode.
Tach Learning
To learn the tach signal:
Procedure:
1. Start the vehicle with the key.
2. Within 5 seconds, press and HOLD the Valet/Override switch.
3. The LED will glow constantly when the tach signal is learned.
4. Release the Valet/Override switch and turn off the vehicle.
Timer Mode
Timer mode can only be accomplished when using the “LOCK” and “UNLOCK” buttons the parking lights will flash 4 times and then start the vehicle and run for the set duration. The remote start can be shut off by the transmitter by pressing the remote start button “ or the “SIREN” icon button on LCD remote transmitters and remain in timer mode, but if any other shut down zone or the ignition becomes active the timer mode will cancel.
Procedure:
1. Press the “LOCK” and “UNLOCK” buttons together.
2. The vehicle confirms with 4 parking light flashes.
3. A 1-second delay will start.
4. The system will start the vehicle and will run for the specified duration, unless shut down by the remote start button “ or the “SIREN” icon button on LCD remote transmitters. If shut down with the remote start button “ or the “SIREN” icon button on LCD remote transmitters the system will remain in timer mode.
*
5. The system will start every 3 hours until canceled by the brake, hood, or neutral safety shut-down wires. To exit timer mode, turn the ignition switch on any time the engine is not running. The parking lights will flash 4 times indicat­ing timer mode has been exited.
6. The system will start every 3 hours until canceled by the brake, hood, or neutral safety shut-down wires.
*
*
146
Ungo ProSecurity
LED Flashes Shut Down Mode
1 Timed Out 2 Over-Rev Shut Down 3 Low or No RPM 4 Remote Shut Down (or Optional Push-Button) 6 (-) Shut Down (Gray Wire) or (+) Shut Down (Brown Wire) 7 (-) Neutral Safety Switch Shut Down (Black/White Wire) 8 Wait-to-Start Timed Out
LED Flashes Trigger Type
1 Multiplexed Input (Blue Wire) 2 Multiplexed Shock Sensor Input (Blue Wire) 3 Door Trigger 4 Multiplexed Shock Sensor Input (Green Wire) 5 Ignition Input (Yellow Wire) 6 Hood Pinswitch (Gray Wire), Brake Pedal (Brown Wire)
Short-Run/Turbo Timer Mode
Short run turbo timer mode keeps the engine running after arriving at your destination for a programmed period of 1, 3, 5, or 10 minutes. This allows the system’s timer to conveniently cool down the turbo after you have left the vehicle.
Procedure:
1. Park the vehicle and set the parking brake.
2. Remove your foot from the brake pedal and leave the engine running.
3. Press and release the “ ” and “AUX” buttons together at the same time.
4. The parking lights will flash to indicate the remote start has entered short run turbo mode.
5. Turn off the key, the engine will keep running.
6. Exit and secure the vehicle.
7. The engine will turn off after the programmed run time.
*
Remote Start Diagnostics
Procedure:
1. With the ignition OFF, press and HOLD the Valet/Override button.
2. Turn the ignition ON and then back OFF while HOLDING the Valet/Override button.
3. Release the Valet/Override button.
4. Press and release the Valet/Override button. The LED will report the last shutdown for one minute or until the ignition is turned ON.
Security Diagnostics
The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full trigger, the older of the two triggers in memory will be replaced by the new trigger.
Procedure:
1. With the ignition OFF, press and HOLD the Valet/Override switch.
2. Turn on the ignition.
3. Release the Valet/Override switch.
4. Press and release the Valet/Override switch within 5 seconds. The LED will flash in groups indicating the last two zones that triggered the system. The LED will flash for one minute or until the ignition is turned OFF.
147
Ungo ProSecurity
Trouble Shooting
Alarm Troubleshooting
Shock sensor doesn’t trigger the alarm:
Has the false alarm prevention circuitry system been triggered? If so, you will hear 5 chirps when disarming the system. To check this, turn the ignition key ON and OFF to clear the false alarm prevention circuity’s memory, and then retest the shock sensor.
Door input does not immediately trigger full alarm. Instead, chirps are heard for the first 3 seconds:
That’s how progressive two-stage door input works. This is a feature of this system. This is an instant trigger, remem­ber, since even if the door is instantly closed again, the progressive from chirps to constant siren will continue.
Closing the door triggers the system, but opening the door does not:
Have you correctly identified the type of door switch system? This happens often when the wrong door input has been used.
System will not passively arm until it is remotely armed and then disarmed:
Are the door inputs connected? Is the Blue wire connected to the door trigger wire in the vehicle? Either the Green or Violet wire should be used instead.
Door input does not respond with the progressive trigger, but with the immediate full alarm:
Does the status LED indicate that the trigger was caused by the shock sensor? The shock sensor, if set to extremely sensitivity may be detecting the door unlatching before the door switch sends its signal. Reducing the sensitivity can solve this problem.
The Valet/Override switch doesn’t work:
Is it plugged into the correct socket?
Status LED doesn’t work:
Is it plugged into the correct socket?
Door locks operate backwards:
This unit has easily reversed lock/unlock outputs. Recheck the wire connections to see if you have these reversed.
Remote Start Troubleshooting
The remote start will not activate:
1. Check the harnesses and their connections. Make sure that the harnesses are completely plugged in the remote start module. Make sure these are good connections to the vehicle wiring.
2. Check the voltage and fuses. Use a meter to check for voltage between the constant wires and ground wire(s). If you have less than battery voltage, check the fuses in the system. Also make sure that the ground wire connects to a good chassis ground point.
3. Check diagnostics. The diagnostics will tell you which shut down is active or not connected.
The remote start will activate, but the starter never engages:
1. Check for voltage on the Violet starter wire two seconds after the remote start becomes active. If there is voltage present, skip to Step 4. If there is not voltage present, advance to Step 2.
2. Check the 30A fuses.
3. Check diagnostics. If the Gray/Black wire is detecting ground upon activation, the starter will not crank.
4. Make sure the Violet starter wire is connected on the starter side of the optional starter kill/anti-grind relay.
5. Does the vehicle have an immobilizer? Some immobilizer systems will not allow the vehicle to crank if active.
6. Check connections. The Red heavy gauge input wires on the relay satellite should have solid connections. “T-Taps” or “Scotch Locks” are not recommended for any high current heavy gauge wiring. Also, if the vehicle has more than one 12-volt input wire, then connect one red wire to each.
148
Ungo ProSecurity
The vehicle starts, but the starter keeps running:
1. Is the system programmed for engine checking OFF or voltage sense? When programmed for either or these features, the engine cranks for the preprogrammed crank time regardless of how long it takes for the vehicle to actually start. Adjust to a lower cranking time.
2. Was the Tach learn successful? The LED must light solid and bright to indicate a successful learn.
3. Make sure that there is a tach signal at the Purple/White tach input wire on the remote start. If there is not a tach signal, recheck the connection to the vehicle’s tach wire and make sure the wire is not broken or shorted to ground leading to the remote start.
The vehicle will start, but will only run for 10 seconds:
1. Is the remote start programmed for voltage sense? Try programming the unit for low voltage reference. If this does not work, a tach wire should be used.
2. Check diagnostics.
The climate control system does not work during remote start activation:
Either the wrong accessory wire is being energized or more than one ignition or accessory wire must be energized in order to operate the climate control system.
149
Ungo ProSecurity
K20: Keyless Entry System
Main Harness
Wire Color Function
Violet Unlock #87 Normally Open Input Red/White (-) Output for Channel 2 Black/Blue Unlock #30 Common Output Brown/Black Unlock #87A Normally Closed
Violet/Black Lock #87 Normally Open Input Orange (-) 500mA Ground-When-Armed Output White/Black Lock #87 Normally Closed Yellow (+) Switched Ignition Input Green/Black Lock #30 Common Output White/Blue (-) Output for Channel 3 Black/White Output for Domelight Supervision Relay #30 Lt
. Green/Black (-) Factory Disarm Output Black/White Input for Domelight Supervision Relay #87 Brown (-) Horn Honk Output Blue (-) 200mA 2nd Unlock Output Black (-) Chassis Ground Red (+) 12v Constant White (+/-) Parking Light Flash Output
Ports
White Status LED Blue Valet/Override Switch
K10: Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (-) Parking Light Output White/Blue (-) 200mA Channel 3 Validity Output Black/White (-) 200mA Domelight Supervision Output Green Not Used Blue (-) Second Unlock Output Violet Not Used Black (-) Chassis Ground Yellow (+) Ignition Input Brown (-) Horn Output Red (+) Constant Power Red/White (-) 200mA Channel 2 Auxiliary Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock, (+) Unlock Output Empty Blue (-) Unlock, (+) Lock Output
Wiring Quick Reference
150
Ungo ProSecurity
RK1: Remote Start/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) Activation Input Black/White (-) 200mA Domelight Supervision Output Green Not Used Blue (-) Second Unlock Output Violet Not Used Black (-) Chassis Ground
Brown (-) Horn Output Red (+) Constant Power Red/White (-) 200mA Channel 2 Auxiliary Output
4-Pin Harness
Wire Color Function
Lt. Green/Black (-) Factory Alarm Disarm Gray/Black (-) Wait-to-Start Input Green/White (-) Factory Alarm Rearm Violet/Black (-) 200mA Channel 4 Auxiliary Output
5-Pin Harness
Wire Color Function
Black/White (-) Neutral Safety Input Violet/White Tachometer Input Brown (+) Brake Shutdown Input Gray (-) Hoodpin Shutdown Input Blue/White (-) 200mA 2nd Status / Rear Defogger Output
Relay Satellite
Wire Color Function
Purple (+) Starter Side Starter Wire (Output) Green (+) Key Side Starter Wire (Input) Red (+) 12v Constant Input Orange (+) Accessory Output Red (+) 12v Constant Input Pink (+) Ignition Output Red/White (+) 12v Constant Input Pink/White (+) 2nd Ignition Output
4-Pin Harness on Relay Satellite
Wire Color Function
Pink (-) 200mA 3rd Ignition Output Violet (-) 200mA Starter Output Orange (-) 200mA 2nd Accessory Output Blue (-) Status Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock, (+) Unlock Output Empty Blue (-) Unlock, (+) Lock Output
151
RS10: Remote Start/Keyless Entry System
Main Harness
Wire Color Function
White (+/-) Parking Light Output Black (-) Chassis Ground Red/White (-) 200mA Channel 2 Auxiliary Output White/Red (+) Activation Input Gray/Black (-) Wait-to-Start Input White/Blue (-) Activation Input Yellow (+) Ignition Output Green/White (-) Factory Alarm Rearm Lt. Green/Black (-) Factory Alarm Disarm
4-Pin Harness
Wire Color Function
Pink (-) 200mA 3rd Ignition Output Violet (-) 200mA Starter Output Orange (-) 200mA 2nd Accessory Output Blue (-) Status Output
5-Pin Harness
Wire Color Function
Black/White (-) Neutral Safety Input Violet/White Tachometer Input Brown (+) Brake Shutdown Input Gray (-) Hoodpin Shutdown Input Blue/White (-) 200mA 2nd Status / Rear Defogger Output
Relay Satellite
Wire Color Function
Red (+) 12v Constant Input Pink (+) Ignition Output Violet (+) Starter Output Orange (+) Accessory Output Red (+) 12v Constant Input Pink/White (+) 2nd Ignition Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock Empty Blue (-) Unlock
Ungo ProSecurity
152
RK20: Remote Start/Keyless Entry System
Main Harness
Wire Color Function
White (+/-) Parking Light Output Black (-) Chassis Ground Red/White (-) 200mA Channel 2 Auxiliary Output Brown (-) Horn Honk Output Orange (-) Ground-When-Locked White/Blue (-) Activation Input Yellow (+) Ignition Output Green/White (-) Factory Alarm Rearm Lt. Green/Black (-) Factory Alarm Disarm
4-Pin Harness
Wire Color Function
Pink (-) 200mA 3rd Ignition Output Violet (-) 200mA Starter Output Orange (-) 200mA 2nd Accessory Output Blue (-) Status Output
5-Pin Harness
Wire Color Function
Black/White (-) Neutral Safety Input Violet/White Tachometer Input Brown (+) Brake Shutdown Input Gray (-) Hoodpin Shutdown Input Blue/White (-) 200mA 2nd Status / Rear Defogger Output
Relay Satellite
Wire Color Function
Red (+) 12v Constant Input Pink (+) Ignition Output Violet (+) Starter Output Orange (+) Accessory Output Red (+) 12v Constant Input Pink/White (+) 2nd Ignition Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock Empty Blue (-) Unlock
Ungo ProSecurity
153
Ungo ProSecurity
S100: Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) 200mA Channel 3 Validity Output Black/White (-) 200mA Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Yellow (+) Ignition Input Brown (+) Siren Output Red (+) Constant Power Red/White (-) 200mA Channel 2 Auxiliary Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock, (+) Unlock Output Empty Blue (-) Unlock, (+) Lock Output
S400: Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) 200mA Channel 3 Validity Output Black/White Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Yellow (+) Ignition Input Brown (+) Siren Output Red (+) Constant Power Red/White Channel 2 Auxiliary Output
8-Pin Harness
Wire Color Function
Violet Unlock #87 Normally Open (Input) Blue/Black Unlock #30 Common (Output) Brown/Black Unlock #87A Normally Closed Violet/Black Lock #87 Normally Open (Input) Green/Black Lock #30 Common (Output) White/Black Lock #87A Normally Closed Black/White Domelight Supervision Relay Input #87 Red/White Channel 2 Relay Input #87
154
Ungo ProSecurity
S660: 2-Way Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue No Function Black/White (-) Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Empty Brown (+) Siren Output Red (+) Constant Power Red/White (-) Channel 2 Auxiliary Output
7-Pin Harness
Wire Color Function
Empty Empty Empty Empty Empty Yellow (+)Ignition Input Empty
6-Pin Harness
Wire Color Function
Lt. Green/Black (-) Factory Alarm Disarm Gray/Black No Function Green/White (-) Factory Alarm Rearm Violet/Black (-) 200mA Channel 4 Output White/Black (-) 200mA Channel 5 Output Lt. Blue (-) 2nd Unlock Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock Empty Blue (-) Unlock
155
Ungo ProSecurity
S670: 2-Way Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) Channel 3 Auxiliary Output Black/White Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Yellow (+) Ignition Input Brown (+) Siren Output Red (+) Constant Power Red/White (-) Channel 2 Auxiliary Output
7-Pin Harness
Wire Color Function
Violet Unlock Relay Normally Open Relay #87 Blue/Black Unlock Relay Common Relay #30 Brown/Black Unlock Relay Normally Closed Relay #87A Violet/Black Lock Relay Normally Open Relay #87 Green/Black Lock Relay Common Relay #30 White/Black Lock Relay Normally Closed Relay #87A Black/White Input to On-Board Domelight Supervision Relay #87
3-Pin Harness
Wire Color Function
Violet/Black (-) 200 mA Channel 4 Output Brown/Black (-) 200mA Horn Honk Output Blue (-) 200mA Second Unlock Output
2-Pin Male Terminals
Wire Color Function
Terminal Starter Interrupt Input/Out Terminal Starter Interrupt Input/Out
SR1000: Remote Start/Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) Activation Input Black/White (-) Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Empty Brown (+) Siren Output Red (+) Constant Power Red/White (-) Channel 2 Auxiliary Output
156
SR1000: Remote Start/Security/Keyless Entry System
(continued)
5-Pin Harness
Wire Color Function
Black/White (-) Neutral Safety Input Violet/White Tachometer Input Brown (+) Brake Shutdown Input Gray (-) Hoodpin Shutdown Input Blue/White (-) 200mA Status/Defogger Output
6-Pin Harness
Wire Color Function
Lt. Green/Black (-) Factory Alarm Disarm Output Gray/Black (-) Wait-to-Start Input Green/White (-) Factory Alarm Rearm Output Violet/Black (-) 200mA Channel 4 Output White/Black (-) 200mA Channel 5 Output Lt. Blue (-) 2nd Unlock Output
Relay Satellite
Wire Color Function
Purple (+) Starter Side Starter Wire (Output) Green (+) Key Side Starter Wire (Input) Red (+) 12v Constant Input Orange (+) 12v Accessory Output Red (+) 12v Constant Input Pink (+) 12v Ignition Output Red/White (+) 12v Constant Input Pink/White (+) 12v Ignition 2 Output
4-Pin Harness on Relay Satellite
Wire Color Function
Pink (-) 200mA 3rd Ignition Output Violet (-) 200mA 2nd Starter Output Orange (-) 200mA 2nd Accessory Output Blue (-) Status Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock, (+) Unlock Output Empty Blue (-) Unlock, (+) Lock Output
Ungo ProSecurity
157
Ungo ProSecurity
SR5000: 2-Way Remote Start/Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) Activation Input Black/White (-) Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Empty Brown (+) Siren Output Red (+) Constant Power Red/White (-) Channel 2 Auxiliary Output
6-Pin Harness
Wire Color Function
Blue (-) 200mA Status/Factory Alarm Rearm Output Blue/Black (-) 200mA 3rd Ignition Output Gray (-) Hoodpin Shutdown Input Brown (+) Brake Switch Shutdown Input Violet/White Tachometer Input Black/White (-) Neutral Safety Switch Input
3-Pin Harness
Wire Color Function
Gray/Black (-) Wait-to-Start Input Lt. Green/Black (-) Factory Disarm/Special Accessory Output Violet/Black (-) Programmable Channel 4 Output
Relay Satellite
Wire Color Function
Red (+) 12v Constant Input Red (+) 12v Constant Input Pink (+) 12v Ignition Output Orange (+) 12v Accessory Output Purple (+) 12v Starter Output Pink/White (+) 12v 2nd Ignition Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock, (+) Unlock Output Empty Blue (-) Unlock, (+) Lock Output
158
SR6000, SR7000, SR9000: 2-Way Remote Start/Security/Keyless Entry System
Main Harness
Wire Color Function
Orange Ground When Armed (-) 500mA White (+/-) Parking Light Output White/Blue (-) Activation Input Black/White (-) Domelight Supervision Output Green (-) Door Trigger Input Blue (-) Instant Trigger Input Violet (+) Door Trigger Input Black (-) Chassis Ground Empty Brown (+) Siren Output Red (+) Constant Power Red/White (-) Channel 2 Auxiliary Output
6-Pin Harness
Wire Color Function
Lt. Green/Black (-) Factory Alarm Disarm Gray/Black (-) Wait-to-Start Input Green/White (-) Factory Alarm Rearm Violet/Black (-) 200mA Channel 4 Output White/Black (-) 200mA Channel 5 Output Lt. Blue (-) 2nd Unlock Output
5-Pin Harness
Wire Color Function
Black/White (-) Neutral Safety Input Violet/White Tachometer Input Brown (+) Brake Shutdown Input Gray (-) Hoodpin Shutdown Input Blue/White (-) 200mA 2nd Status/Rear Defogger Output
2-Pin Harness
Wire Color Function
Orange/Black (-) 200mA Channel 6 Output Brown (-) 200mA Horn Output
Relay Satellite
Wire Color Function
Purple (+) Starter Side Starter Wire (Output) Green (+) Key Side Starter Wire (Input) Red (+) 12v Constant Input Orange (+) 12v Accessory Output Red (+) 12v Constant Input Pink (+) 12v Ignition Output Red/White (+) 12v Constant Input Pink/White (+) 12v 2nd Ignition Output
Ungo ProSecurity
159
Ungo ProSecurity
SR6000, SR7000, SR9000: 2-Way Remote Start/Security/Keyless Entry System
4-Pin Harness on Realy Satellite
Wire Color Function
Pink (-) 200mA 3rd Ignition Output Violet (-) 200mA 2nd Starter Output Orange (-) 200mA 2nd Accessory Output Blue (-) Status Output
3-Pin 2-Wire Door Lock Harness
Wire Color Function
Green (-) Lock, (+) Unlock Output Empty Blue (-) Unlock, (+) Lock Output
160