Contents under pressure. Can cause severe injury
or death from tank rupture.
When starting system:
• When starting system, water output must be
open when lling.
• Do not exceed pressure of 115 psi (8Bar).
• Check system for cracks.
• Be sure cover is in locked position.
• Keep water output open and hold yellow lever
down to remove trapped air from system.
• For use only with drinking water.
Before servicing system:
• Shut off drinking water supply and open
water output.
• Disconnect water supply and allow tank to drain.
2
DANGER
Spilled resin is a slipping hazard.
Clean up spilled resin immediately.
Resin can cause skin irritation.
Avoid skin contact.
Wash hands thoroughly after use.
Can cause eye irritation.
Avoid eye contact.
Wear safety goggles.
In case of eye contact, immediately ush
eyes thoroughly with clean water.
Consult doctor if symptoms persist.
READ MANUAL BEFORE
USING PRODUCT
ungerglobal.com
STORAGE: Do not store resin
in open or unlabeled containers.
Store in a cool (15°F to 100°F),
dry place.
DISPOSAL: Dispose of in
accordance with applicable
federal, state/provincial, and
local regulations.
All HydroPower models
require the use of mixed
bed ion exchange resin
(commonly referred to as
de-ionizing resin).
This resin will require
replacement and handling.
Installation &
Operating Instructions
Introduction
Thank you for choosing nLite HydroPowerTM for your pure water needs.
You have chosen a high quality product backed by Unger’s 100% customer
satisfaction guarantee. When used as intended, the nLite HydroPower unit will
produce zero TDS pure water for site glass cleaning.
The production of pure water, through deionization, is based on the principal of
ion exchange. In this process, the minerals responsible for producing spotting
are removed from the water.
The use of nLite HydroPower has the following advantages:
• With a waterfed wash pole and brush will effectively clean glass and other
surfaces without the need for chemicals.
• Run-off does not have to be remediated, and is safe for plants and animals.
• No electricity or external power supply needed – system works with plumbing
line pressure.
• QuickChangeTM resin bags are factory filled with the precise amount of
mixed bed DI Resin for optimum system performance.
As with any commercial equipment, care must be taken when operating and
servicing the unit. There is a risk of damage to the system due to:
• Operating and installation errors.
• Use of loose resin (overll and expansion of resin will damage unit).
• Vessel is opened incorrectly.
• Using non-Unger spare parts.
• Performing unauthorized modication to unit.
• Insufcient maintenance.
Use only original spare parts by Unger (according to spare parts list, pg. 14).
For all inquiries and spare parts orders, it is important to provide detailed
information located on the device (serial and/or part number).
ungerglobal.com
3
Installation &
Operating Instructions
Safety Information
General:
Please observe applicable rules and regulations, including all accident prevention
procedures. Unger is not liable for damage to application areas, plumbing
system components or persons.
The window cleaning contractor should strictly adhere to all applicable local,
state/provincial and federal labor laws and safety codes and standards.
Ensure work area has sufficient water drainage.
Turn off feed water supply when not in use.
Transportation:
Ensure unit is properly secured to car, trailer, van or truck bed during
transportation.
Intended Use:
This device may be dangerous if it is improperly installed, not regularly
maintained or not used as intended. Use this device only for water treatment
to reach an optimal water quality for glass and facade cleaning. Any other use,
especially water treatment for food production (e.g., beverages) or drinking water
consumption is prohibited.
4
ungerglobal.com
Installation &
Operating Instructions
General hazards associated with the use of waterfed wash pole and
deionization equipment1:
• Read and follow ANSI Standard IWCA 1-14.1 (Window Cleaning Safety).
• Trip hazard to the general public when using trailing hoses.
• Slip hazard presented from wet pathways.
• Slip hazard for operator when concentrating on work.
• Falls from height when working on at roofs.
• Electrocution from poles coming into contact with overhead power source.
• Injuries to others from falling poles or fabric of the building that may
be dislodged.
• Injury to others from falling poles caused by incorrect handling or failure of pole.
• Injury through incorrect manual handling of poles and other equipment.
• Hazards from carrying tanks, systems and equipment that are overloaded,
unstable, unsecured or incorrectly installed within a vehicle.
Puried water is delivered to the waterfed wash pole by exible hose.
This introduces a risk of tripping by both worker and general public.
Identify work area with appropriate signage.
Any surface that becomes wet must be identified with appropriate signage to
direct pedestrians and workers away from work area. During wintertime, it is
important to avoid water pooling, which could freeze, creating a dangerous
slip hazard.
1. British Window Cleaning Academy (BWCA): Safety in window cleaning using waterfed pole systems.