Uncategorized SPORT BOATING Instruction Manual

OWNER’S M ANU A L
DO NOT REMOVE PRIOR TO SALE
INFLATABLE PERSONAL FLOTATION DEVICE (PFD)
SPORT BOATING (16g cylinder)
Type V User Assisted Inflatable PFD, U.S. Coast Guard approved only when for use in place of Flotation Aid, Type III PFD on recreational boats. Approved to meet
USB6MM
This PFD requires additional inflation by mouth after CO2 inflation to achieve maximum performance. A Type V approved condition lets users overcome its design trait that would otherwise prevent approval.
This Type V User Assisted Inflatable PFD is designed to provide the user with a device that is comfortable to wear at all times while underway, and an in-water performance that is at least equivalent to an inherently buoyant Type III device. Wearing a PFD while boating has been shown to significantly improve the wearers safety.
carriage requirements only for inland waters, and not approved for offshore use.
With an initial CO2 inflation, this PFD will turn many wearers to face up stable position. An initial CO2 inflation will allow the wearer to easily blow air into the chamber to achieve a higher level of freeboard and turning performance.
By wearing this PFD:
1) It gets needed extra attention associated with use:
2) Users get to know the disadvantages it has; and
3) Safety increases enormously because user has it when needed
When PFD is not worn, it’s less likely to be in working order and cannot be counted as a PFD to meet the carriage requirements on your boat.
WARNING!
WARNING!
This PFD will not float you without inflation! Each CO2 inflator body will only inflate the PFD once. You must rearm this PFD after each use of the CO2.
This device will not inflate automatically upon immersion. Tab must be pulled to activte inflation mechanism.
Approval Conditions and Carriage Regulations
This inflatable PFD is approved by the U.S. Coast Guard for use as the Type indicated on the cover. It is not approved for water skiing or other high impact, high speed activities. This inflatable was designed to be more comfortable and less restrictive to wear than inherently buoyant PFDs. When worn, used, and serviced according to this owner’s manual, this PFD can greatly increase your chances of survival in the water. NOT recommended for non-swimmers or weak swimmers. Users of inflatable PFDs must be at least 16 years old.
Mandatory Carriage Requirements
Federal regulations in 33 CFR 175-1993 require you to carry Coast Guard approved personal flotation devices (PFDs) legibly marked with the Coast Guard approval number which are in good and serviceable condition and are the correct size for each person on board. To be considered serviceable, this PFD shall not exhibit deterioration that could diminish its performance such as broken or deformed hardware, detached webbing, rotted structural components, air leaks, or non-functional oral inflation tube. Unless worn inflated, this PFD must also be properly armed with a full CO2 cylinder, inflation system status indicator, and an accessible manual inflation lanyard. A PFD which is “approved only when worn” or “required to be worn” must be worn under the specified conditions.
It is imperative that the inflatable PFD is properly adjusted to fit the person wearing it. An incorrect fit, or improper donning can inhibit the effectiveness of the device, or result in injury. Do not wear inflatable PFDs underneath any type of clothing, serious injury may result.
Specifications:
User Weight: Chest size: Age Limitation:
USB6MM: Rearming Kit V87000-82123Z
Features: 15-1/2 lbs design buoyancy with CO2
22.5 lbs of buoyancy with secondary oral inflate
Halkey-Roberts Corp. V87000 manual inflation system
P.1
More than 80 pounds 30 to 52 inches
16 years of age and older
INSTRUCTION FOR USE
1. Where and How to Check Inflation System Status Indicators:
It is necessary to open the cover over the inflator to determine whether the device is armed according to the instructions on page 4.
be on the front of the body and hanging down from the bottom of the device.
2. Donning Instructions:
Halkey-Roberts V87000 Manual Inflator
Donning Instructions:
1. The Velcro opening should
be on the bottom of the device.
2. Buckle the waist belt, adjust
envelope should be positioned to the front of the body.
3.
should be on the front of the body and hanging down from the bottom of the device.
Status Indicators
OK
STOP
STOP
Second Stage Donning Instructions:
1.
behind your head.
2. If needed use the oral tube
You do not need to removed device to
Use BLQ200T Black 1071 as a top-stitch overlay for this panel.
P.2
3. Inflation and Deflation
INFLATION
CO2 inflation (Manual Inflation PFD) The PFD is manually inflated by grasping the manual inflation pull tab
JERK TAB
JERK TAB
TO INFLATE
TO INFLATE
and pulling sharply downward.
Oral Inflation: The oral inflation tube is located inside the cover. To inflate orally, access the inflation tube by opening the top portion of the cover, remove the dust cap, and blow air into the tube until the inflatable is firm.
BLOW INTO
BLOW INTO
Use BLQ200T Black 1071 as a top-stitch overlay for this panel.
ORAL TUBE
ORAL TUBE
Note: Oral inflation can be used to test for air leakage or as a back-up in the event that the CO2 cylinder fails to operate. CO2 gas permeates the bladder more quickly than air, and therefore oral inflation can be used to refill the bladder in the event the wearer is in the water for an extended period.
Do not fully inflate the PFD orally and then inflate with CO2 cylinder as bladder could incur damage.
Additional inflation by mouth or adjustment in the water is required for
to float and easily achieve inflation by mouth.
DEFLATION
The deflation tab is located on top of the dust cap. Turn the dust cap upside down and insert the deflation mechanism into the oral tube. Hold the deflation mechanism in place with your finger and gently squeeze all the air out of the PFD. If the PFD has inflated while being worn, it may be necessary to partially deflate the PFD in order to remove it.
To remove all air, roll the PFD into a ball and squeeze while operating the deflation mechanism. The PFD will be difficult to fold and re-pack properly if not completely deflated.
PRESS DOWN
PRESS DOWN
ON ORAL TUBE
ON ORAL TUBE
PRACTICE wearing and adjusting your inflatable PFD in the water in order to be prepared for an emergency!
Practice wea
ring and inflating your PFD using different types of clothing. Wade into the water and manually inflate. Practice until you have complete confidence in the performance of your PFD.
P.3