Signature Series
Homeowner / User Guide
SS-2412-EZ
SS-2419-EZ
1-866-GO-UV-AIR (468-8247)
ultravation.com
Thank you for purchasing an Ultravation
®
Professional Indoor Air Quality Product
UltraMAX™EZUV™Signature Series
UV Air and Surface Disinfection for HVAC
Package Contents:
• Light Shield
• T3 Enhanced UVC Light
• ESP3 24VAC Power Supply with
power switch and diagnostics
UVLampMonitor Status
LED Audible Alarm Unit Status
Blue No Sound Normal
Flashing Red 6 second beep Replace Lamp(s)
• Magnetic Mount
• 6 - 3/4 inch 5/16 self tapping sheet
metal screws
• Warranty Card
Your UltraMAX™ EZUV™ is equipped
with an electronic power supply that
monitors operation and protects the UV
lamp filaments. It also monitors elapsed
time and reminds after 18,000 hours of
operation that lamps need to be replaced.
Below is a chart that describes how to
interpret the display.
AFETY PRECAUTIONS:
S
It is recommended that this unit be installed and maintained by a trained technician:
WARNING: UV Hazard. Always protect eyes from ultraviolet light.
NEVER look at UV lamps in operation. Unplug or disconnect power before
re-lamping or servicing.
WARNING: Severe eye damage or temporary blinding may occur.
WARNING: DO NOT operate outside of air handler. Mount lamp base to
duct first.
WARNING: No openings in HVAC system are allowed which would give
direct line-of-sight to the UV light.
In the event of accidental breakage or replacement of the ultraviolet lamp, please
ensure that the lamp is disposed of in accordance with local and state environmental
laws regarding fluorescent lamps containing mercury.
Notice: All wiring inside air handling system in direct line of site of the UV lamp must
be shielded with aluminum foil tape or equivalent non-combustible material. When
installing this unit, select a mounting location that prevents ultraviolet light exposure
to plastic non UV-rated flexible duct liner or other plastic components with unknown
resistance to ultraviolet light. Ultraviolet light may cause color shift or structural
degradation of plastic HVAC components. If installing where UV light can directly
contact fiberglass duct board, contact manufacturer of fiberglass product for advice
on UV rating. If unknown, install metal sheathing or foil tape to completely protect
fiberglass duct board from UV light exposure.
DC-OH-0229A
Lamp Replacement and Reset Procedure
It is recommended that a certified technician perform these operations.
Note to technician: When replacing lamps, turn off power to the unit first. Then
follow installation instructions for lamp replacement.
After the lamps are in place, the Service Indicator Light must be reset.
Steps for resetting the Service Indicator Light
1. Restore power to the EZUV Signature Series unit and turn it on.
2. Press down and hold the RESET button for 10 seconds. The LED will turn blue
while button is depressed.
3. Release the RESET button.
4. The LED should remain blue after button is released.
REPLACEMENT PARTS AND ACCESSORIES
12" T3 UVC Lamp .............................................................................. AS-IH-1001
17" T3 UVC Lamp .............................................................................. AS-IH-1003
12” Light Shield with magnet ............................................................. 94-066-M
17” Light Shield with magnet .............................................................. 94-067-M
Optional PCO plate ............................................................................ 94-004
Please contact your local dealer or use the Authorized Contractor Locator on
Ultravation.com for replacement lamps and parts.
To silence alarm, press reset for one second.
Troubleshooting
Ultravation® air disinfection equipment is designed to provide many years of trouble
free operation. In the unlikely event of a problem, please contact your local HVAC
professional or Ultravation directly. Before calling for service, you should have the
model number, serial number, and purchase date.
If you are troubleshooting the unit, please check the following:
• To save energy and maintain performance, the EZUV Signature Series automatically
turns off if the lamp has not been changed after two years. If this is the case,
replace the lamp and press the reset button on the side of the power supply.
• Verify that the UV lamp(s) is on or off—but never look at a UV lamp in operation!
You can safely confirm operation by way of the UV viewport installed with the unit.
• Verify the unit has power. Check voltage requirement on power supply label and
confirm proper power is supplied.
• Be sure lamps are securely plugged into their sockets, no loose wires, and in the
correct orientation (see other side of this sheet).
• If possible install a new lamp to determine whether the problem is the lamp or the
power supply.
Remember: DO NOT look at UV light without proper eye protection.
UL Listed. The health aspects associated with the use of this product and its ability to aid in disinfection of environmental
air have not been investigated by UL.
Lifetime Warranty
Ultravation®EZUV™ Signature Series features Ultravation’s lifetime warranty, with the
exception of the ultraviolet lamp(s), which are warranted for a period of one year after
date of consumer purchase.
This warranty does not include damage to the unit from accident, misuse or improper
installation.
If this product should become defective, Ultravation will elect to repair or replace the
product free of charge. Ultravation will return repaired or replaced warranted products
pre-paid to the customer, provided that the product was delivered pre-paid.
Ultravation shall have no responsibilities for charges incurred by the customer for
installation or removal of warranted items. Liability is limited only to the replacement or
repair of this product.
This warranty gives you specific legal rights, and you may also have other rights, which
vary from state to state. All returns must be accompanied by a return authorization
number, which may be obtained by contacting Ultravation, Inc.
Ultravation, Inc.
P.O. Box 165, 212 Ideal Way, Poultney, Vermont 05764
Phone: 1-866-GO-UV-AIR (468-8247) • Fax: 802-287-9203
www.ultravation.com • info@ultravation.com
Copyright © 2008-2013 Ultravation Inc.
Ultravation.com
Installation and Maintenance
We recommend that this unit be installed and maintained by a trained HVAC
professional technician.
Installation steps for external mounting of power supply:
1. Determine a suitable location to install unit housing. Mounting location should be of
sufficient strength as to support the unit, otherwise reinforcement of the ductwork may
be necessary. Fasten the unit in place with two self-tapping screws (supplied).
2. Select location for UV lamp module. Drill a 1" hole. Install mounting plate over
drilled hole with screws provided. Insert UV lamp into hole. Attach to mounting plate
system with two self-tapping screws (supplied).
3. Attached the rubber lamp connector fully onto the installed UV lamp assembly. Be
sure the four pinholes are orientated properly to the four matching pins on the lamp
(see diagram at right).
4. Connect power wires to a dedicated minimum 40VA transformer or hardwire to
appropriate voltage based on requirements listed on power supply label.
This should be done in accordance with all state and local electrical and
building codes.
Notes: The UV lamp assembly can be removed independently, by removing the
two screws in the lamp holder.
The rectangular pin pattern allows connection in two positions (see other
side of this sheet).
A UV status viewport lens is supplied to verify lamp operation. Drill a 3/8"
hole within a 3" radius around the lamp, and on the “lamp side” of the “V” in
the light shield. Snap viewport into place.
Important! Read before installation
The screw holes on the UV lamp
need to be parallel to the lamp lead
cord on the back of the female
receptacle for correct assembly!
Note that lamp connector pin pattern
is NOT square.
It can be mounted from either side
and top or bottom depending on the
orientation of the installed lamp.
Installation steps for internal mounting of power supply:
1. Mount power supply inside of the air handler but out of the air stream as much as
possible. Place the power supply close to the control panel for ease of connecting to
24 VAC or appropriate voltage according to the power supply label.
2. To utilize the internal mounting bracket, first install the bracket inside the air handler
in a location that will position the UV lamp such that it bathes the entire surface to be
treated. Plug the lamp connector onto the lamp and snap into the bracket.
Note: The rectangular pin pattern can be mated in two positions only.
3. Connect power wires to a dedicated minimum 40VA transformer. This must be done in
accordance with all state and local electrical and building codes.
Maintenance
Never perform maintenance on the UV unit without disconnecting power. Typical
maintenance consists of replacement of the ultraviolet (UV) lamps. UV lamps undergo a
photochemical process during operation, that slowly reduces the amount of UV light
generated to disinfect the air and surfaces. For optimum air stream disinfection UV lamps
should be replaced annually. For surface disinfection, lamp replacement should be
performed no later than every two years (see below, “Important Information about UV
lamp replacements”). When installing new lamps, ensure that the lamp glass is free from
any fingerprints or debris, as this may alter the path of the UV energy. Use rubbing
alcohol and a dry cloth to remove any surface contamination.
Important information about UV lamp replacements
Replace UV lamp(s) annually in order to maintain optimum effectiveness in the reduction
of pathogens such as bacteria, viruses and microscopic mold. Lamps operating after a
period of 18,000 hours (two years) no longer provide adequate UV-C. When the UV lamp(s)
reach the end of the 18,000 hour useful operating life, the unit automatically turns off. The
UV lamp must be replaced and the power supply reset. Do not reset the power supply
without replacing the UV lamp as worn out UV lamps draw excessive electrical
current which may result in damage to the UV system, and may void the warranty.
Lamp lead (rubber
sleeved female
receptacle)
UVC lamp
Electrical
NOTICE: All 24 volt UV equipment for HVAC systems
(regardless of manufacturer) must be installed using
a separate, dedicated minimum 40VA transformer to
avoid the possibility of voiding UL certification of the
HVAC system.
Lamp screw holes and lamp lead
cord need to be parallel
Ultravation.com
Horizontal orientation of
the lamp lead requires
installing the lamp with
screws left to right.
DC-OH-0229A