Models: 92-022, 92-142 (200-350 CFM) Models: 92-023, 92-141 (650-950 CFM)
Table of Contents:
Page 2- Shipping and Packaging list, Introduction and Application, Safety Precautions, Power Consumption
Page 3-
Page 4- Troubleshooting, Warranty, Replacement Part Numbers
Maintenance, Replacing Filter, Replacing Photo catalytic Lamps
LEAVE FOR HOMEOWNER
DC-IH-0211
Shipping and Packaging List:
Filter Housing including Access Door
Merv 11 Media Air Filter
*HEPA Filter
PCO Filter
Electrical Enclosure
2- 12” UVC Lamps
* If the option was purchased
Introduction and Applications:
This Ultravation Stand Alone Photronic HEPA is a stand alone air cleaning system. This high efficiency air filtration unit is designed to remove dirt, dust, pollen, and microscopic particles: reduce unpleasant odors, VOC gases and the microbial population from the air that circulates through it. By adding this device to your HVAC system, you are helping to create a cleaner indoor living environment for your whole household.
The system works in 2-3 steps (depending on model purchased, some models do not include the germicidal protection in step 3)
STEP 1: Trapping particles in the pleats of the MERV 11 media filter. With an extra large surface area, the filter allows for maximum dirt holding capacity and a long, useful filter life with minimum air flow restriction.
STEP 2: VOC’s and gases such as the f umes from new carpets, paints, nail polish, cigar and cigarette smoke are drastically reduced photo chemically via a patented process known as photo catalytic conversion or photo catalytic oxidation.
STEP 3: Germicidal UVC light is applied to the Air to drastically reduce or eliminate unwanted virus, bacteria and mold.
This air cleaner is to be installed in a forced air heating, cooling and ventilation system. It should be installed so that all the system’s air is circulated through the filter first and VOC Section second. The air cleaner will only filter the air that is circulated through it. For maximum filtration effect, set your blower to operate continuously. (Lower speeds allow for higher efficiency)
Safety Precautions:
It is recommended that this unit be installed and maintained by a trained technician:
WARNING: UV Hazard. Always protect eyes from ultraviolet light. NEVER look at UV lamps in operation. Unplug or disconnect power before re­lamping or servicing.
WARNING: Severe eye damage or temporary blinding may occur.
WARNING: DO NOT operate outside of Air Handler. Mount lamp base to duct first.
WARNING: No openings in duct are allowed which would give direct line-of-sight to the UV light.
In the event of accidental breakage or replacement of the ultraviolet lamp, please ensure that the lamp is disposed of in accordance with local and state environmental laws regarding fluorescent lamps containing mercury.
Notice:
All wiring inside of the duct or air handling system in direct line of site of the UV lamp must be shielded with aluminum foil tape or equivalent non-combustible material. When installing this unit, select a mounting location that prevents ultraviolet light exposure to plastic flexible duct liner or other plastic components with unknown resistance to ultraviolet light. Ultraviolet light may cause color shift or structural degradation of plastic HVAC components
Power Consumption UV-A, UV-C lamps
Lamp Type 12-inch UVC lamp is 16 watts each 2 Note: Handle fits either door. A Phillips screw driver
will be required to install the handle. Handle holes are behind the label on either door, depending on the orientation of the installation.
Quantity Required
2