Contact Information .................................................................. 8
Note: Please read entire manual before operating the Turbo Fan
www.ultratecfx.com
2
Warning
Important Safety Instructions:
!!!
Safety Precautions
!!!
www.ultratecfx.com
3
Technical Specications
Model:Turbbo Fan
Part Number:CLF-2850 Turbo Fan 110V/220V (Wireless)
CLF-2851 Turbo Fan 110V/220V (Non-Wireless)
CLS-7300 Turbo Fan Snow Machine 110V
CLS-7301 Turbo Fan Snow Machine Sleeve Assy
CLS-7303 Turbo Fan Snow Machine 220V
Length:23in58.42cm
Width:21in53.34cm
Height:10in25.4cm
Weight:51 lb. (61 lbs. with snow front option)
Output:2500 cfm @ 1800 Ft/min
Power:3 / 1.5 amps (.3 KW or .4 HP)
Noise level:70 dB
Technical Drawings
www.ultratecfx.com
4
Turbo Fan
The Turbo Fan is a heavy duty stainless steel constructed machine that is, quiet, durable and powerful. It incorporates a
ratchet, positive locking positioning base for quick and easy use. It comes with a built-in variable speed control and can
also be controlled by an optional DMX/W-DMX with RDM mode interface for powerful, fast and secure control. The dual
voltage selector switch allows operation in either 110V/220V making it very versatile.
DMX Control:
The DMX control will occupy 3 consecutive channels. The rst channel controls the fan speed from 0-100%. The second
channel determines direction of ow where a setting above 50% provides reverse ow. The third channel will provide
snow volume if the fan is in the reverse direction and the fan speed is over 10%, this requires the optional snow machine.
The base DMX address can be selected from 1 – 510 with 3 consecutive addresses occupied. The arrow keys below each
address digit increases that digit. The “Valid DMX” LED indicates the presence of a stable DMX signal.
DMX ChannelControl
Base DisplayedFan speed from 0 to 100%
Base + 1Fan direction (0 - 49% Forward / 50% - 100% - Reverse)
Base + 2Snow Volume from 0 to 100% (Base must = 10% or higher, Base + 1 must = 50% or higher)
RDM
The wired DMX connection is also RDM enabled. Basic instruction set includes identication and DMX re-addressing.
Local Operation:
The fan can be controlled locally by using higher numbers in the DMX display.
700-799 will give forward fan speed settings of 0-99 which equates to OFF to 100%
800-899 will give reverse fan speed settings of 0-99 which equates to OFF to 100%
6xy-699 will give (x = 0-9) reverse fan speed and (y = 0-9) snow volume. There is a 5 second delay before the snow starts.
Wireless Option:
Optional wireless control is provided by a WDMX radio transceiver. In DMX mode the fan can be used as a drop point
to other equipment. The function switch is used to unlink the radio (By pressing and holding for 3 seconds only). The
link status is displayed on the blue Led. Solid blue indicates linked, fast ashing indicates linking, Slow ashing indicates
searching for a linked transmitter and off indicates unlinked. A Yellow LED will indicate signal strength when receiving DMX
data. When receiving valid DMX data the red valid DMX Led will be on solid.
Note: if wireless RDM features are implemented (user must program them) the fan will no longer be usable as a drop point.
Note: wireless and wired DMX can’t both be actively present.
www.ultratecfx.com
5
Before applying power verify that the voltage selector switch is set for the voltage to be applied. This switch is located
beneath the lower compartment lid. Hang securely or place the fan on the legs in a stable location.
Select the correct line cord for local conditions and connect to the fan. If the optional snow machine is used connect
it before powering the fan. Verify both ends of the fan are clear of possible obstructions and personal. Power on the
fan with care as it will start in the last mode it was used. Use the address switch buttons to select the desired setting.
If under DMX control the red valid DMX Led will be on if a signal is present. If the optional WDMX radio is used it will
light the blue Led when linked to a transmitter and the red DMX Led with show signal.
Note: Do not supply both wired and wireless DMX to the fan at the same time.
Snow Machine Option:
The snow machine option consists of 2 parts. The rst part is the ring that attaches to the back side of the fan, this
is the directional ow end. The grill retaining screws are used to attach this ring. The second part of the option is the
blow box. This will have the air hose and uid tube from the snow ring attached to the front end. A control cable
connects to the fan’s control box. The power for the blower connects to an appropriate power source. Note: the
blower in the blow box is not dual voltage, so the appropriate voltage model must be purchased for the
power source being supplied. The blower box can hold a 4 liter jug of uid. If a pail is to be used the jug holder can
be removed. If the blower is to be hung an optional truss bracket will be required. If a pail is to be used there is also an
option truss mount for this purpose.
Snow will only be issued when the fan is in reverse direction, this prevents snow from being accidentally drawn into the
fan. The rate of snow is controlled to produce the desire ake size of snow. The high volume snow sock will need to be
cleaned regularly to maintain optimum performance. A lower volume sock is available that requires less cleaning. The
snow machine should be ushed with water for about 1 minute when not in use to prevent clogging lines and to rinse
the snow sock.
Local Mode Snow Operation:
1. Connect Blower box control cable to Turbo Fan
2. Plug Snow Blower box to appropriate power source and ip Mains power switch to ON
3. Set DMX address on Turbo Fan to 600 (Fan OFF / Snow uid pump OFF) [Blower in box will turn ON after 5
seconds]
4. Adjust middle digit (10s column) on Turbo Fan (1- 9) to start fan in reverse at desired speed
5. Adjust far right digit (one’s column) on Turbo Fan (1-9) to start producing snow.
Note: The air blower in the blow box will turn ON automatically after a few seconds when the Turbo fan is set to local
mode and connected to the blow box with the control cord. This is normal and will not produce any snow until the
control digits on the Turbo Fan display are in the valid range.
Fan Features:
• Constructed of a stainless steel frame and shell gives a durability and toughness to the body.
• The adjustable hanging bracket provides both clamp hanging and oor stand capabilities.
• A secondary quick set bracket allows the fan to sit without extra parts.
• Durable black powder coat paint helps to reduce visible presence and blend into the back ground.
• The turbine style blade allows for quiet blade performance that is reversible.
• Two outlet styles are included, forward for a broad spread of air and reverse for a directional ow of air.
• The self-contained design provides smaller form factor for a full 16” fan.
• Led DMX addressing and control indicators are easy to read in varying light conditions.
• The control link for an optional snow machine gives direct control of the snow machine
• Servo motor with integrated driver provides high reliability in a compact design.
• Precision speed setting gives repeatable settings for superior control performance.
• Switch-mode motor power supply gives dual voltage supply in a lightweight compact design.
www.ultratecfx.com
6
Snow Option:
• Equipped with a 6 foot remote snow head allows the snow machine to be located in a more serviceable location.
• A lower noise prole is achieved with the separated components
• Chassis is constructed from stainless steel for corrosion resistance.
• The detachable jug holder allows for the use of jugs or larger pails.
• A control link to the fan gives auto control from the fan’s control signals.
• The 120 volt model draws 10 amps.
• The 230 volt model draws 5 amps.
• Max uid consumption is 6.6 liters / hour.
• An effective snow is produced at 3.6 liters / hour rate which is about 85% on the DMX setting.
• This machine will require our optional machine hanger to be hung
• Over 60 feet of snow output.
Warnings
!!!!
Maintenance
!!!
www.ultratecfx.com
7
Warranty
Warranty:Hardware products come with a one year warranty on parts and labor. Unless stated otherwise,
this will refer to manufacturer defects only. All warranty is based on destination of the original
sale. Any additional costs incurred are the responsibility of the Dealer and/ or the customer.
Abuse or poor maintenance is not accepted. Proof of purchase or proof of sale must always
accompany all warranty returns. An RA (Return Authorization) number must be noted on
the outside of each box being returned to our facility. Any package(s) without an RA number
clearly marked, will not be accepted by our receiving department. Freight on warranty items are
freight prepaid to our facility and we will prepay freight back to your facility following repair.
This will be done by the most economical means available. Should you require the item expressreturned, the dealer is responsible for request indication and any difference in freight cost.
Export Distributors are required to carry out the warranty repair, parts will be supplied by
Ultratec.
Return Policy:Return of any product must be done within 30 days of purchase. The package must be
returned freight prepaid and the RA number clearly marked on the outside of the box.
Warning:Ultratec Special Effects considers all of it’s product to be safe for use in the application it was
intended. Ultratec Special Effects takes no responsibility for misuse or incorrect use. Always
refer to the Product Manual for proper use.
Contact Information
Head Ofce
Ultratec Special Effects
1960 Blue Heron Drive
London, Ontario N6H 5L9
Ultratec Special Effects GmbH
Dieselstrasse 30-40
60314
Frankfurt am Main
Germany
Direct: 49-69-87-000-1850
Fax: 49-69-87-000-1899
Canadian Shipping Address
(For All Canadian Repairs)
Ultratec Special Effects
1960 Blue Heron Drive
London, Ontario N6H 5L9
Please remember to include the RA Number on all items being shipped
for repairs.
To retrieve an RA Number visit www.ultratecfx.com and click on the
“Service” section. Then click on “Return Authorization Request” which is
located on the left hand side of the page.
If you have any questions or require assistance please contact service at
519-951-3357/866-534-5557 or by email at Service@Ultratecfx.com.
USA Shipping Address
(For All USA Repairs)
Ultratec Special Effects
640 Gadson Street
Groveland, Florida 34736
www.ultratecfx.com
8
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.