Ultratec SILENT STORM DMX User Manual

Silent Storm DMX Snow Machine
Operator’s Manual
www.ultratecfx.com
VER. 30.10.10
Table of Contents
Introduction ................................................................................ 3
Warning ...................................................................................... 3
Important Safety Instructions: ................................................... 3
Technical Specications ............................................................. 4
Technical Drawings ................................................................... 4
Operating Procedure ................................................................. 5
Maintenance ............................................................................... 5
Exterior ..................................................................................... 5
Recommended Fluids ................................................................. 5
Warranty ..................................................................................... 6
Contact Information .................................................................. 6
2
Note: Please read entire manual before operating the Silent Storm
Introduction
The Silent Storm is a snow machine, which can produce spectacular visual effects by creating an articial snow urry for distances of up to 40ft. The machine comes with a remote control and is DMX compatible. It is designed for applications requiring quite operation.
It can be seated, or mounted on an optional truss mount bracket. Adjustable distance and volume of snow can be used to achieve different visual effects.
With proper usage and regular maintenance the Silent Storm will provide years of snow making effects.
Warning
Important Safety Instructions:
1. Keep this device dry to prevent danger of electric shock.
2. Use in 3-prong grounded electrical outlets only.
3. Always unplug the machine before lling its tank.
4. Turn off power when not in use.
5. For adult use only. Snow machine must be installed out of the reach of children.
6. Never leave the unit running unattended.
7. Do not aim out put nozzle directly at anyone.
8. Locate the snow machine in a well-ventilated area.
9. Never cover the unit’s vents – to ensure adequate ventilation allow a free air space of at least 1” around the unit.
10. Never add ammable liquids (oils, gasses, or scent) to the snow uid.
11. Use only Ultratec Special Effects Snow Fluid.
12. Always make sure there is sufcient uid in the tank to prevent damage to the pump.
MSDS available at www.ulratecfx.com
www.ultratecfx.com
3
Technical Specications
Model: Silent Storm
Part Number: CLS 7100 - 120 Volt - 10amps
CLS 7150 - 220-240 Volt - 5amps
Length: 23in 58.5cm
Width: 10.125in 25.7cm
Height: 10.1in 26.8cm
Net Weight:
Net Weight w/ uid:
Power Rating: 120 Volt A.C. 50/60 Hz. 10 Amps.
Fluid: Ultratec Special Effects Snow Fluid
22lbs 10kg
32lbs 14.5kg
240 Volt A.C. 50/60 Hz. 5 Amps
Technical Drawings
4
Operating Procedure
The Silent Storm snow machine requires 120 volts AC at 10 amps (CLS 7100) or 220-240 Volts AC at 5 amps (CLS
7150). The unit can be operated from a wired hand held remote or from a DMX control signal. When DMX data is
present the hand held remote is ignored. A valid DMX signal causes the LED to light on the rear of the machine.
The blower starts before the pump, to allow it to come up to speed. When shut off, the blower runs for several seconds to purge the system. The pump rate is dependent on the blower settings. Low blower settings restrict pump range.
The remote has an On/Off switch with power LED and two ow control knobs. It plugs into the rear of the machine. The remote may be extended with a 100’ cable. The rst knob has a cloud illustration and controls the air speed. Fluid output is controlled by the second knob, which is denoted with a snowake. As the air speed is reduced the maximum uid rate is also reduced to prevent excess foam from forming on the nozzle. A range of ake size, noise levels and distances can be achieved by adjusting the two controls.
If the DMX control is used the remote does not need to be installed. DMX control data can also vary the blower and uid ow. Set the base DMX address on the rear of the machine. The base DMX address controls the air speed but the base address +1 controls the uid output rate. Don’t set the base DMX address above 511.
Maintenance
The uid pump is subject to burn out if run dry for any period of time. Take care when priming the pump when changing jugs. Keep the air intake ports on the bottom of the chassis free from blockage. With time the sock may accumulate residue, which will impede performance. Running clear water through the machine and rinsing off the sock will restore performance. If storing for extended periods of time ush the unit with clear water. Protect the unit from freezing. In extreme cold, performance will be reduced.
Do not allow the snow liquid to become contaminated. Always replace the caps on the snow liquid container and the snow machine liquid tank immediately after lling. Before storing, ush out system with clean water.
Exterior
To clean, wash with mild soap and warm water.
Recommended Fluids
True North Snow Fluid: The secret to creating realistic-looking snow is in the uid. Extensive research when into creating the best possible snow uid that is odorless and environmentally safe.
Ultimate Extra Dry Snow Fluid: Retaining the same snow properties as our popular True North Snow Fluid, this extra dry solution is perfect for a densely moist and humid environment.
Concentrated Snow Fluid: Available in a 410ml bottle, this Snow Fluid Concentrate is ideal for cost effective transportation and minimizing storage space without compromising quality.
www.ultratecfx.com
5
Warranty
Warranty: All warranty is for one year parts and labour unless specied or manufacturer defect only.
Abuse or Poor Maintenance will not be covered under warranty. Ultratec Special Effects Fluids must always be used. Use of any non Ultratec Special Effects Fluids will void all warranties. Accept no substitutions as there are no exceptions to this rule. Proof of Purchase or Proof of Sale must always accompany any warranty returns. An RA (return authorization) number must be noted on the outside of the box being returned to our facilities. Any packages without a clearly marked RA number will not be accepted by our receiving department. Freight on warranty items are freight prepaid to our facility and we will prepay freight back to your facility after repair by the most economical means available. Should you require the item express­returned, then you are responsible for any difference in freight cost.
Return Policy: Return of any product must be done within 30 days of purchase. The package must be
returned freight prepaid and the RA number clearly marked on the outside of the box. Minimum restocking fee is 25%. Once our facility has received the product a technical assessment will be completed to determine if an additional restocking fee needs to be issued. Only credits are issued to the dealers account. Any product not returned within 30 days is considered purchased.
Warning: Ultratec Special Effects Inc. considers all of it’s product to be safe for use in the application it
was intended. Ultratec Special Effects takes no responsibility for misuse or incorrect use. Always refer to the Product Manual for proper use.
Contact Information
Head Ofce
Ultratec Special Effects Inc. 1960 Blue Heron Drive London, Ontario N6H 5L9
Direct: 519-659-7972 Toll Free: 866-534-5557 Fax: 519-659-7713
Canadian Shipping Address
(For All Canadian Repairs) Ultratec Special Effects Inc. 1960 Blue Heron Drive London, Ontario N6H 5L9
Please remember to include the RA Number on all items being shipped for
repairs.
To get an RA Number, visit www.ultratecfx.com and click on the “Service” tab and then click on “Master Service Tracker or contact service at 519-951-3357 /
866.534.5557
USA Shipping Address
(For All USA Repairs) Ultratec Special Effects Inc. 640 Gadson St. Groveland, Florida 34736
6
Loading...