Ultra Start 4295, 3295 User Manual

REV.2009.10.20
95 SERIES
Advanced Remote Starters & Vehicle Security Systems
THIS MANUAL COVERS THE OPERATIONS OF
THE 3295, 4295 SERIES REMOTE STARTERS
AND ALARMS
WARNING: NEVER USE AN AUTOMATIC TRANSMISSION
STARTER IN A MANUAL TRANSMISSION VEHICLE
95 SERIES
OWNERS MANUAL
TABLE OF CONTENTS.............................................................................................................PAGE 2
IMPORTANT NOTES.................................................................................................................PAGE 3
REMOTE TRANSMITTER.........................................................................................................PAGE4
BUTTON CONFIGURATION ICON DESCRIPTION
QUICK VIEW FUNCTIONS.......................................................................................................PAGE 5-7
REMOTE START FUNCTIONS................................................................................................PAGE 8-9
REMOTE START KEY TAKEOVER REMOTE STOP IDLE MODE EXTENDED RUNTIME TURBO TIMER
SYSTEM FEATURES............................................................................................................PAGE 10-13
LOCK DOORS/ ARM ALARM SHOCK BYPASS TRUNK RELEASE UNLOCK DOORS/ DISARM ALARM DR. UNLOCK AUX OUTPUTS COLD START/ TEMP MODE PANIC MODE SILENT MODE
PROGRAMABLE FEATURES..............................................................................................PAGE 14-15
TIMER MODE ON/OFF PAGER MODE ON/OFF VALET ON/OFF CAR 1/ 2 HORN ON/OFF SHOCK ON/OFF SENSOR SENSITIVITY TEMPERATURE SCALE
PROGRAMABLE FEATURES..................................................................................................PAGE 16
SETTING TIMER MODE SETTING CLOCK
SHOCK SENSOR PROGRAMMING........................................................................................PAGE 17
ENTER SHOCK PROGRAMMING ADJUSTING SENSITIVITY
PAGER FUNCTIONS............................................................................................................PAGE 18-19
ALARM TRIGGERS START FAULT
USER OPTIONS............................
RUN TIME SELECTION TEMPERATURE SETTINGS
VALET/ SERVICE MODE..........................................................................................................PAGE 21
EMERGENCY OVERRIDE MODE
DIAGNOSTICS..........................................................................................................................PAGE 22
TROUBLE SHOOTING
WARRANTY..............................................................................................................................PAGE 23
CONTACT..................................................................................................................................PAGE 24
............................................................................................PAGE 20
TABLE OF CONTENTS
IMPORTANT NOTES
1) FOR SAFETY REASONS THE OWNER/USER MUST INSTALL A CARBON MONOXIDE DETECTOR IN THE LIVING AREA NEAR TO WHERE THE VEHICLE IS BEING STORED OR PARKED.
2) IT IS THE SOLE RESPONSIBILITY OF THE OWNER/USER TO KEEP THE REMOTE TRANSMITTERS AWAY FROM THE REACH OF CHILDREN AND HANDLE WITH CARE SO THAT THE SYSTEM DOES NOT UNINTENTIONALLY START.
3) WHEN THE VEHICLE IS PARKED IN AN ENCLOSED/PARTIALLY ENCLOSED AREA (EX: GARAGE, CAR PORT...), BEING SERVICED (EX: OIL CHANGE) OR THE VEHICLE IS LOANED TO AN OPERATOR NOT FAMILIAR WITH A REMOTE STARTER, THE SYSTEM MUST BE PLACED SERVICE/ VALET MODE.
MANUAL TRANSMISSION STARTERS THIS MODEL IS NOT DESIGNED FOR USE IN A MANUAL TRANSMISSION VEHICLE. DOING SO COULD RESULT IN EXTENSIVE DAMAGE TO YOUR VEHICLE, PROPERTY DAMAGE AND POSSIBLY CAUSE SERIOUS INJURIES OR EVEN DEATH!!
IF THIS MODEL WAS INSTALLED INTO YOUR MANUAL TRANSMISSION VEHICLE, RETURN TO YOUR DEALER AND HAVE IT REPLACED WITH THE CORRECT MANUAL TRANSMISSION MODEL IMMEDIATELY!!!!
OWNERS MANUAL
95 SERIES
NEVER OPERATE THE SYSTEM IN AN ENCLOSED OR PARTIALLY ENCLOSED AREA!
95 SERIES
OWNERS MANUAL
REMOTE TRANSMITTER
Basic Remote Functions
THE NEW 95 SERIES XR 2WAY HYBRID REMOTE IS USER FRIENDLY AND EASY TO OPERATE. THE REMOTE DISPLAYS THE CURRENT STATUS OF YOUR SYSTEM USING BOTH ICONS AND TEXT ON ITS UNIQUE LCD DISPLAY.
Basic Remote Functions
LOCK/ ARM ALARM
UNLOCK/ DISARM ALARM
OFF
ON
1 2 3
UNLOCK
PROGRAM
ULTRA
REMOTE START/ STOP
TRUNK RELEASE
STATUS UPDATE
BUTTON #5
/ START STATUS
Basic Icon Description
3
5
TEXT–
7
1 2
ON OFF
1 2
PROGRAM
8 9 10
11
ICON DESCRIPTION
1- USER MODE ICON
4
6
1
2- FEATURE STATUS 3- RANGE INDICATOR 4- TIMER MODE ICON 5- DISPLAY TEXT 6- PROGRAM MODE ICON 7- LOCK ICON 8- UNLOCK ICON 9- START/RUN ICON 10- LOW TEMP MODE 11- TRUNK RELEASE ICON
QUICK VIEW CHART
95 SERIES
OWNERS MANUAL
DISPLAY BUTTON PRESS
1
LOCK
1
PANIC
1
LOCK
LOCK - PRESS & RELEASE
LOCK - PRESS & HOLD 4 SECONDS
PRESS AND RELEASE PRESS AND RELEASE (WITHIN 2 SECONDS)
1
UNLOCK
1
LOCK
1
UNLOCK
1
UNLOCK
UNLOCK - PRESS & RELEASE
LOCK - PRESS & RELEASE (WHILE ALARM TRIGGERED)
UNLOCK - PRESS & RELEASE (WHILE ALARM TRIGGERED)
UNLOCK- PRESS AND RELEASE UNLOCK- PRESS AND AN RELEASE
AUDIBLE
1 BEEP / 1 BEEP
SERIES OF BEEPS
1 BEEP PAUSE 1 BEEP
1 BEEP / 2 BEEPS
1 BEEP
1 BEEP
2 BEEPS PAUSE 1 BEEP
FUNCTION
LOCK THE DOORS & ARM THE ALARM* *ALARM MODELS ONLY.
ACTIVATES THE PANIC MODE FEATURE.
ACTIVATES THE CONSTANT LOCK OUTPUT FEATURE* *THE LOCK OUTPUT WILL STAY ON FOR 4 SECONDS.
ACTIVATES WINDOW ROLL UP ON SELECT VEHICLES.
UNLOCK THE DOORS & DISARM THE ALARM* *ALARM MODELS ONLY.
TURNS OFF THE SIREN BUT THE ALARM WILL STAY ARMED. *ALARM MODELS.
TURNS OFF THE SIREN BUT THE ALARM WILL STAY ARMED. *ALARM MODELS.
ACTIVATES THE DRIVER’S DOOR PRIORITY UNLOCK FEATURE. MAY REQUIRE ADDITION PARTS OR LABOUR. MUST BE PROGRAMMED FOR OUTPUT TO ACTIVATE.
1
TRUNK
TRUNK- PRESS AND HOLD FOR 4 SECONDS TRUNK- PRESS & RELEASE
1 BEEP PAUSE 3 BEEPS
ACTIVATES THE TRUNK RELEASE OUTPUT. *DISARMS ALARM, UNLOCKS DOORS & TRUNK ICON FLASHES WHEN REMOTE STARTED LCD WILL DISPLAY CURRENT RUNTIME.
QUICK VIEW CHART
95 SERIES
OWNERS MANUAL
DISPLAY BUTTON PRESS
1
START
KEY- PRESS AND HOLD FOR
3 SECONDS TILL REMOTE BEEPS
AUDIBLE
1 BEEP PAUSE
TONE
FUNCTION
ACTIVATES THE REMOTE CAR STARTER FUNCTION. THE DEFAULT RUNTIME IS 15 MINUTES.
THEN RELEASE
IF THE VEHICLE DOES NOT START A START FAULT CODE WILL BE DISPLAYED. THE START FAULT WILL CLEAR THE NEXT TIME THE SYSTEM IS LOCKED OR UNLOCKED. PLEASE SEE FAULT CODE SECTION OF MANUAL FOR MORE INFORMATION.
1
STOP
1
EX RUN
1
IDLE
1
TURBO
1
M-1234
*REMOTE PROGRAM MODE ALLOWS THE USER TO SET OR CHANGE DEFAULT FEATURES OF THE SYSTEM SUCH AS TIMER MODE, PAGER MODE, VALET MODE. SEE REMOTE PROGRAM MODE FOR MORE PROGRAMMABLE OPTIONS.
STATUS
(BUTTON 5)
(BUTTON 5)
KEY- PRESS AND HOLD
WHILE VEHICLE IS RUNNING
KEY- PRESS & RELEASE WHILE RUNNING BY STARTER
KEY- PRESS & RELEASE WHILE RUNNING BY KEY
PRESS & RELEASE WHILE RUNNING BY KEY
PRESS & HOLDSTATUS
1 BEEP PAUSE 1 BEEP
1 BEEP PAUSE
TONE
1 BEEP PAUSE
TONE
2 BEEPS
MELODY
TURNS OFF THE REMOTE CAR STARTER.
THE SYSTEM WILL AUTOMATICALLY TURN OFF AFTER THE DEFAULT RUNTIME (15 MINUTES) HAS EXPIRED.
RESETS THE RUN TIME.
THIS FEATURE WILL EXTEND THE CURRENT RUNTIME WHILE THE SYSTEM IS RUNNING BY THE REMOTE START.
ACTIVATES THE IDLE MODE FEATURE.
THE VEHICLE WILL RUN FOR 15 MINUTES WHEN THE KEY IS REMOVED.
ACTIVATES THE TURBO TIMER MODE FEATURE.
THE VEHICLE WILL RUN FOR 2 MINUTES WHEN THE KEY IS REMOVED.
ENTERS REMOTE PROGRAM MODE.
SEE REMOTE PROGRAM MODE SECTION OF THE MANUAL FOR MORE DETAILS.
95 SERIES
OWNERS MANUAL
QUICK VIEW CHART
DISPLAY BUTTON PRESS
1
LOCK
1
PRESS AND RELEASE THE LOCK AND UNLOCK BUTTONS AT THE SAME TIME.
UNLOCK
1
AUX 1
1
AUX 2
THE AUXILIARY OUTPUTS ARE USED TO ACTIVATE ADDITIONAL FUNCTIONS SUCH AS WINDOW ROLL-UP AND GAS CAP RELEASE. THESE FUNCTIONS MAY REQUIRE ADDITIONAL PARTS AND LABOUR. SEE DEALER FOR MORE INFORMATION.
1
LOCK
1
SENOFF
1
DISARM
1
STATUS
(BUTTON 5)
PRESS AND HOLD THE UNLOCK AND TRUNK BUTTONS FOR 5 SECONDS
PRESS AND HOLD THE UNLOCK AND STATUS BUTTONS FOR 5 SECONDS
LOCK- PRESS AND RELEASE SHOCK SENSOR BYPASS
WITHIN 3 SECONDS
KEY- PRESS AND RELEASE
PRESS AND RELEASE
12:25PM
AUDIBLE
1 BEEP PAUSE 1 BEEP
OR
1 BEEP PAUSE 2 BEEPS
1 BEEP PAUSE TONE
1 BEEP PAUSE TONE
1 BEEP PAUSE TONE
1 BEEP PAUSE 1 BEEP
FUNCTION
IF THE DOORS ARE UNLOCKED/ SYSTEM DISARMED * THE DOORS WILL LOCK WITH NO CHIRPS. IF THE DOORS ARE LOCKED/ SYSTEM ARMED* THE DOORS WILL UNLOCK WITH NO CHIRPS.
*ALARM MODELS ONLY.
ACTIVATES THE AUXILIARY #1 OUTPUT. THE OUTPUT WILL STAY ACTIVE FOR 4 SECONDS.
ACTIVATES THE AUXILIARY #2 OUTPUT. THE OUTPUT WILL STAY ACTIVE FOR 4 SECONDS
NOTE: THIS FEATURE MUST BE SET BY INSTALLER - REFER TO INSTALL GUIDE
THE SHOCK SENSOR WILL BE DISABLED UNTIL THE NEXT TIME THAT THE SYSTEM IS DISARMED THEN REARMED
*ALARM MODELS ONLY
STATUS UPDATE THIS FEATURE DISPLAYS THE CURRENT STATUS OF THE SYSTEM, THE TEMPERATURE THEN THE TIME.
* IF NO TEMP SENSOR IS INSTALLED OR IF THE SENSOR HAS AN ERROR THE TEMP DISPLAYED WILL BE -121 C.
95 SERIES
OWNERS MANUAL
PRESS AND HOLD THE START BUTTON ON THE REMOTE FOR
1
P 12:45
1
START
1
RUN 15
IF THE VEHICLE DOES NOT START A START FAULT CODE WILL BE DISPLAYED.
PLEASE SEE FAULT CODE SECTION OF MANUAL FOR MORE INFORMATION.
ENTER THE VEHICLE THEN INSERT THE KEY INTO THE IGNITION CYLINDER. TURN THE KEY FORWARD TO THE ON POSITION. (TYPICALLY 2 POSITIONS) STEP ON THE BRAKE AND THE REMOTE STARTER WILL TURN OFF AND THE VEHICLE WILL STAY RUNNING.
3 SECONDS UNTIL THE REMOTE BEEPS THEN RELEASE. THE PARK LIGHTS WILL FLASH. THE HORN (OPTIONAL) WILL CHIRP 1 TIME.
ULTRA
THE REMOTE WILL BEEP AND “START” WILL BE DISPLAYED ON THE LCD AFTER THE VEHICLE HAS STARTED THE RUN
. TIME WILL BE DISPLAYED AND REMOTE WILL PLAY THE START TUNE.
ULTRA
THE HORN (OPTIONAL) WILL CHIRP AND THE PARK LIGHTS WILL TURN ON AND STAY ON FOR THE PROGRAMMED RUNTIME. THE REMOTE WILL FLASH THE RUN TIME THEN TURN OFF.
ULTRA
PRESS & RELEASE THE TRUNK BUTTON TO CHECK THE RUN TIME.
SYSTEM FUNCTIONS
*IF THE VEHICLE SHUTS OF THE KEY WAS NOT TURN FORWARD TO THE IGNITION/RUN POSITION.
WARNING- DO NOT TURN THE KEY TO THE START POSITION WHILE THE VEHICLE IS RUNNING BY THE REMOTE START.
SYSTEM FUNCTIONS
1
STOP
ULTRA
1
RUN 15
ULTRA
95 SERIES
OWNERS MANUAL
PRESS AND HOLD THE START BUTTON ON THE REMOTE FOR 3-5 SECONDS OR UNTIL VEHICLE SHUTS OFF. THE PARK LIGHTS WILL TURN OFF AND THE HORN (OPTIONAL) WILL CHIRP 2 TIMES. THE REMOTE WILL BEEP AND “STOP” WILL DISPLAYED ON THE LCD.
PRESS AND RELEASE THE START BUTTON (KEY) WHILE RUNNING WITH KEY. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIRPS 2 TIMES. THE REMOTE WILL BEEP AND DISPLAY THE RUN TIME. REMOVE THE KEY THEN EXIT VEHICLE. THE VEHICLE WILL CONTINUE TO RUN FOR THE PROGRAMMED RUNTIME.
1
RUN 4
1
RUN 15
1
TURBO
ULTRA
ULTRA
ULTRA
PRESS AND RELEASE THE START BUTTON WHILE THE REMOTE STARTER IS ACTIVE. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL WILL CHIRP 1 TIME.
THE REMOTE WILL PLAY THE START TUNE AND THE RUN TIME WILL RESET TO THE DEFAULT SETTING.
PRESS AND RELEASE THE STATUS BUTTON WHILE RUNNING WITH THE KEY. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIRPS 2 TIMES. THE REMOTE WILL BEEP AND DISPLAY “TURBO”. REMOVE THE KEY THEN EXIT VEHICLE. THE VEHICLE WILL CONTINUE TO RUN FOR 2 MINUTES.
95 SERIES
OWNERS MANUAL
PRESS & RELEASE

PAGE 10

SYSTEM FUNCTIONS
ARM SYSTEM / LOCK DOORS
1
P 12:45
PRESS AND RELEASE THE LOCK BUTTON ON THE REMOTE TRANSMITTER. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIRP 1 TIME.
ULTRA
THE REMOTE WILL BEEP 1 TIME AND “LOCK” WILL BE DISPLAYED ON THE LCD SCREEN.
1
LOCK
THE DOORS WILL LOCK AND THE ALARM WILL ARM* *ALARM MODELS ONLY.
ULTRA
THE LEDS ON THE ANTENNA START FLASHING 3 SECONDS AFTER LOCKING. NOTE- THE LEDS CAN BE PROGRAMMED NOT TO FLASH WHEN LOCKED.
*ON ALARM MODELS THE ALARM IS ARMED WHEN THE DOORS ARE LOCKED. THE ALARM WILL ACTIVATE IF A DOOR IS OPENED, HOOD IS OPENED AND IT THE SHOCK IS SENSOR IS ACTIVATED. THE REMOTE WILL DISPLAY THE TRIGGER THAT SET THE ALARM OFF. SEE ALARM TRIGGERS FOR MORE INFORMATION.
ARM SYSTEM WITH SHOCK OFF
PRESS AND RELEASE THE LOCK BUTTON THEN WITHIN 4
1
LOCK
SECONDS PRESS AND RELEASE THE START BUTTON.
THE LCD WILL DISPLAY “LOCK” WHEN THE LOCK BUTTON IS
ULTRA
PRESS THEN “SENOFF” WHEN THE START BUTTON IS PRESSED.
OFF
1
SENOFF
THIS FEATURE DISABLES THE SHOCK SENSOR UNTIL THE NEXT TIME THE ALARM IS DISARMED THEN REARMED.
ULTRA
*ALARM MODELS ONLY.

PAGE 11

SYSTEM FUNCTIONS
OWNERS MANUAL
95 SERIES
PRESS AND RELEASE THE UNLOCK BUTTON ON THE
1
P 12:45
ULTRA
REMOTE TRANSMITTER. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIRP 2 TIMES.
THE REMOTE WILL BEEP 2 TIMES AND “UNLOCK” WILL BE DISPLAYED ON THE LCD SCREEN.
1
UNLOCK
ULTRA
THE DOORS WILL UNLOCK AND THE ALARM WILL DISARM* ALARM MODELS ONLY.
THE LEDS ON THE ANTENNA WILL STOP FLASHING.
*IF THE ALARM IS ACTIVATED PRESSING THE UNLOCK BUTTON ONCE WILL STOP THE SIREN BUT THE ALARM WILL STAY ARMED. TO FULLY DISARM THE ALARM YOU MUST PRESS AND RELEASE THE UNLOCK BUTTON A SECOND TIME.
PRESS AND RELEASE THE UNLOCK BUTTON ON THE
1
UNLOCK
ULTRA
REMOTE TRANSMITTER. THE REMOTE WILL BEEPS 2 TIMES AND THE LCD WILL DISPLAY “UNLOCK”. THE HORN WILL CHIRP AND THE PARK LIGHTS WILL FLASH 2 TIMES THEN THE DRIVER’S DOOR WILL UNLOCK.
1
D-LOCK
ULTRA
PRESS AND RELEASE THE UNLOCK BUTTON A SECOND TIME WITH IN 3 SECONDS TO UNLOCK THE REMAINING DOORS. THE REMOTE WILL BEEP 1 TIME AND “D-LOCK” WILL BE DISPLAYED ON THE LCD.
*OPTION FEATURE. MAY REQUIRE ADDITION PARTS AND LABOUR.
95 SERIES
OWNERS MANUAL
1
PANIC
1 1
LOCK
1
TRUNK
SYSTEM FUNCTIONS
PANIC MODE
HOLD THE LOCK BUTTON FOR 4 SECONDS TO ACTIVATE THE PANIC ALARM. THE PARK LIGHTS WILL FLASH AND THE HORN WILL BEGIN TO CHIRP.
ULTRA
THE LCD WILL DISPLAY “PANIC” / “ALARM” AND BEEP ON & OFF
TO EXIT PANIC MODE, PRESS ANY BUTTON ON REMOTE.
SILENT ARM/ DISARM
PRESS AND RELEASE THE LOCK AND UNLOCK BUTTONS TOGETHER AT THE SAME TIME. THE SYSTEM WILL TOGGLE BETWEEN LOCK/ARM & UNLOCK DISARM.
ULTRA
THE PARK LIGHTS WILL FLASH BUT THE HORN WILL NOT CHIRP AS CONFIRMATION. THE REMOTE WILL DISPLAY LOCK OR UNLOCK DEPENDING ON THE LAST FUNCTION.
TRUNK RELEASE
PRESS AND HOLD THE TRUNK RELEASE BUTTON. THE DOORS WILL UNLOCK, THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIP 2 TIMES.
ULTRA
THE PARK LIGHTS WILL FLASH AGAIN AND HORN (OPTIONAL) WILL CHIRP 1 MORE TIME THEN THE TRUNK WILL OPEN.

PAGE 12

THE REMOTE WILL BE 2 TIMES PAUSE THEN ONCE AGAIN. “TRUNK” WILL DISPLAY ON THE LCD.

PAGE 13

SYSTEM FUNCTIONS
1 1
AUX 1
ULTRAULTRA
1 1
AUX 2
1
1
ON
TEMP
1
TEMP
ULTRA
1
OFF
ULTRA
95 SERIES
OWNERS MANUAL
AUX 1 OUTPUT
PRESS THE UNLOCK AND TRUNK BUTTONS FOR 3 SECONDS. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIRP 2 TIMES. THE DOORS WILL UNLOCK THEN THE AUX 1 OUTPUT WILL ACTIVATE FOR 4 SECONDS. THE REMOTE BEEPS 2 TIMES THEN 1 TIME THEN DISPLAY “AUX1" ON THE LCD.
AUX 2 OUTPUT
PRESS THE UNLOCK AND STATUS BUTTONS FOR 3 SECONDS.. THE PARK LIGHTS WILL FLASH AND THE HORN (OPTIONAL) WILL CHIRP 2 TIMES. THE DOORS WILL UNLOCK THEN THE AUX 2 OUTPUT WILL ACTIVATE FOR 4 SECONDS. THE REMOTE BEEPS 2 TIMES THEN 1 TIME THEN DISPLAY “AUX2" ON THE LCD.
NOTE: FEATURE MUST BE PROGRAMMED ON BY INSTALLER - SEE INSTALL GUIDE
COLD START/ TEMP MODE
HOLD THE LOCK AND START BUTTONS FOR 3 SECONDS. THE REMOTE WILL BEEP 1 TIME TO CONFIRM THAT TEMP MODE IS “ON”. LCD DISPLAYS “ TEMP” ON.
IF TEMP MODE WAS ON THEN REMOTE WILL BEEP 1 TIME TO CONFIRM THAT TEMP MODE IS “OFF” REMOTE WILL DISPLAY “TEMP” OFF.
SEE REMOTE PROGRAM MODE FOR INFORMATION ON TEMPERATURE SETTINGS.
95 SERIES
OWNERS MANUAL
PROGRAMMING

PAGE 14

REMOTE PROGRAM MODE
REMOTE PROGRAM MODE ALLOWS THE USER TO SET FEATURES ON OR OFF FROM THE REMOTE TRANSMITTER. SEE THE INSTRUCTIONS BELOW TO CHANGE A USER SETTING.
TO ENTER PROGRAM MODE
M-1234
PROGRAM
ULTRA
PRESS AND HOLD THE STATUS BUTTON ON THE REMOTE FOR 4 SECONDS. THE REMOTE WILL BEEP 1 TIME AND THEN 3 TIMES. THE DISPLAY WILL SHOW “PROGRAM” & “M-1234"
PRESS LOCK TO GO TO TIMER SETTING OR PRESS STATUS TO EXIT.
ON
ON
TIMER
TIMER
PROGRAM
PROGRAM
ULTRA
ULTRA
PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT.
ON
ON
PAGER
PAGER
PROGRAM
PROGRAM
ULTRA
ULTRA
PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT.
ON
VALET
PROGRAM
ULTRA
PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT.
CONTINUED ON NEXT PAGE...
TURN TIMER MODE ON / OFF (TIMER ICON ON/OFF)
PRESS THE LOCK BUTTON TO SELECT TIMER MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF
TURN PAGER ON / OFF
PRESS THE LOCK BUTTON TO SELECT PAGER MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF
TURN VALET ON / OFF
PRESS THE LOCK BUTTON TO SELECT VALET MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF

PAGE 15

PROGRAMMING
95 SERIES
OWNERS MANUAL
REMOTE PROGRAM MODE
ON
CAR 1
PROGRAM
ULTRA
PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT.
ON
ON
TIMER
HORN
PROGRAM
PROGRAM
ULTRA
ULTRA
PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT.
ON
SHOCK
PROGRAM
ULTRA
PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT.
ON
C/F
PROGRAM
ULTRA
PRESS LOCK TO GO BACK TO THE FIRST SETTING OR PRESS STATUS TO EXIT.
SWITCH FROM CAR 1 TO CAR 2
PRESS THE LOCK BUTTON TO SELECT CAR MODE PRESS THE UNLOCK BUTTON TO SELECT CAR 1 PRESS THE START BUTTON TO SELECT CAR 2
TURN HORN CHIRPS ON / OFF
PRESS THE LOCK BUTTON TO SELECT HORN MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF
TURN SHOCK SENSOR ON / OFF (ALARM MODELS)
PRESS THE LOCK BUTTON TO SELECT SHOCK MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF
SETS REMOTE TEMPERATURE DISPLAY FROM CELSIUS TO FAHRENHEIT
PRESS THE LOCK TO SELECT CELSIUS PRESS THE UNLOCK TO SELECT FAHRENHEIT
95 SERIES
OWNERS MANUAL
PROGRAM FEATURES
FEATURES SUCH AS TIMER SET, CLOCK SET AND TEMPERATURE MODE ARE SET BY HOLDING MULTIPLE BUTTONS TO ADUST.
PROGRAMMING

PAGE 16

+
TIMER SET MODE
TIMER SET MODE ALLOWS THE USER TO PROGRAM THE REMOTE STARTER TO START AT A PRESET TIME OF THE
P 12:35
PROGRAM
ULTRA
TO ENTER TIMER SET MODE PRESS AND HOLD THE START (KEY) AND STATUS BUTTONS ON THE REMOTE FOR 4 SECONDS. THE REMOTE WILL BEEP 1 TIME THEN THE PROGRAM AND CLOCK ICONS TURN ON.
PRESS THE LOCK BUTTON TO CHANGE FROM HH TO MM PRESS THE UNLOCK BUTTON TO INCREASE THE SETTING PRESS THE LOCK BUTTON TO DECREASE THE SETTING
DAY. ONCE THE TIME IS SET THE “TIMER ON” FUNCTION MUST BE ENABLED THROUGH THE REMOTE PROGRAMMING MENU.
+
CLOCK SET MODE
P 12:35
PROGRAM
ULTRA
TO SET THE CLOCK TIME
PRESS AND HOLD THE LOCK AND STATUS THE REMOTE FOR 4 SECONDS. THE REMOTE WILL BEEP 1 TIME THEN THE PROGRAM AND CLOCK ICONS TURN ON.
PRESS THE LOCK BUTTON TO CHANGE FROM HH TO MM PRESS THE UNLOCK BUTTON TO INCREASE THE SETTING PRESS THE START BUTTON TO DECREASE THE SETTING
BUTTONS ON
PRESS AND RELEASE THE STATUS BUTTON TO EXIT.

PAGE 17

PROGRAMMING
95 SERIES
OWNERS MANUAL
SHOCK SENSOR PROGRAMMING
THE SHOCK SENSOR SENSITIVITY IS SET USING THE REMOTE PROGRAM MODE FEATURE. ALARM MODELS ONLY.
ENTER REMOTE PROGRAM MODE
TO ENTER PROGRAM MODE
M-1234
PROGRAM
ULTRA
PRESS AND HOLD THE STATUS BUTTON ON THE REMOTE FOR 4 SECONDS. THE REMOTE WILL BEEP 1 TIME AND THEN 3 TIMES. THE DISPLAY WILL SHOW “PROGRAM” & “M-1234"
ENTER SHOCK SENSITIVITY PROGRAMMING
1
SEN 5
OFF
ULTRA
PRESS AND RELEASE THE UNLOCK BUTTON THE SENS LEVEL WILL BE DISPLAYED
ADJUSTING THE SENSOR SENSITIVITY
1
SEN 3
1
SEN 7
OFF
ULTRAULTRA
OFF
PRESS AND RELEASE THE UNLOCK BUTTON TO DECREASE THE SENSITIVITY. THE LCD WILL SHOW THE CURRENT SETTING. THE LOWEST (LEAST SENSITIVE SETTING IS SEN 1.
PRESS AND RELEASE THE START BUTTON TO INCREASE THE SENSITIVITY. THE LCD WILL SHOW THE CURRENT SETTING. THE HIGHEST (MOST SENSITIVE) SETTING IS SEN 10.
EXIT PROGRAM MODE
PRESS AND RELEASE THE STATUS BUTTON ON THE REMOTE TO EXIT.
95 SERIES
OWNERS MANUAL
PAGER FEATURES

PAGE 18

ALARM TRIGGERS & PAGER MODE
WHEN THE ALARM IS TRIGGERED THE SYSTEM WILL PAGE THE REMOTE WITH THE SPECIFIC ALARM TRIGGER. THE REMOTE WILL START TO BEEP AND THE LCD WILL ALTERNATE BETWEEN “ALARM” AND THE “TRIGGER”
1
ALARM
1
ALARM
1
ALARM
1
ALARM
1
ALARM
ULTRA
ULTRA
ULTRA
ULTRA
ULTRA
TOGGLE
TOGGLE
TOGGLE
TOGGLE
TOGGLE
1
DOOR
1
SHOCK
1
HOOD
1
AUX
1
PANIC
DOOR TRIGGER
THIS PAGE WOULD OCCUR IF A DOOR WAS OPENED ON THE
ULTRA
VEHICLE.
SHOCK TRIGGER
THIS PAGE WOULD OCCUR IF THE VEHICLE WAS IMPACTED
ULTRA
HARD ENOUGH TO TRIGGER THE SHOCK SENSOR.
HOOD TRIGGER
THIS PAGE WOULD OCCUR IF A HOOD WAS OPENED ON THE
ULTRA
VEHICLE.
AUX TRIGGER
THIS PAGE WOULD OCCUR IF THE AUXILIARY SENSOR
ULTRA
INPUT IS TRIGGERED.
PANIC TRIGGER
THIS PAGE WOULD OCCUR IF THE SYSTEM WAS SET INTO
ULTRA
PANIC MODE. (LOCK HELD FOR 3 SECONDS).

PAGE 19

PAGER FEATURES
OWNERS MANUAL
95 SERIES
FAULT CODE VIA PAGER
IF THE STARTER FAILS TO START THE REMOTE WILL DISPLAY A FAULT CODE ON THE LCD DISPLAY. THE TEXT “FAULT” WILL BE FOLLOWED BY THE INPUT OR CONDITION
1
FAULT
ULTRA
TOGGLE
1
BRAKE
BRAKE FAULT
THIS FAULT WOULD OCCUR IF THE BRAKE THERE WAS AN
ULTRA
ISSUE WITH THE BRAKE CIRCUIT.
1
FAULT
ULTRA
TOGGLE
1
HOOD
HOOD FAULT
THIS FAULT WOULD OCCUR IF THE HOOD WAS OPENED OR
ULTRA
THE HOOD SWITCH IS BROKE OR OUT OF ALIGNMENT.
1
FAULT
ULTRA
TOGGLE
1
TACH
TACH FAULT
THIS FAULT WOULD OCCUR IF THE VEHICLE HAD A START
ULTRA
ISSUE SUCH AS A DEFECTIVE BYPASS MODULE.
1
FAULT
1
FAULT
THE FAULT CODE WILL BE DISPLAYED WITH THE NEXT FUNCTION UNTIL THE SYSTEM IS UPDATED WITH THE STATUS BUTTON.
TOGGLE
ULTRA
TOGGLE
ULTRA
1
VALET
1
RANGE
VALET FAULT
THIS FAULT WOULD OCCUR IF THE SYSTEM WAS IN VALET
ULTRA
AND YOU PRESSED START.
RANGE FAULT
THIS FAULT WOULD OCCUR IF THE USER WAS OUT OF
ULTRA
OPERATING RANGE.
95 SERIES
OWNERS MANUAL
TO ENTER PROGRAM MODE
M-1234
PROGRAM
ULTRA
PRESS START TO GO TO RUN TIME ADJUSTMENT
PRESS AND HOLD THE STATUS BUTTON ON THE REMOTE FOR 4 SECONDS. THE REMOTE WILL BEEP 3 TIMES THEN DISPLAY “PROGRAM” & “M-1234". PRESS START TO CONTINUE.

PAGE 20

PROGRAMMING
RUN TIME ADJUSTMENT
ON
ON
TIMER
RUN 15
PROGRAM
PROGRAM
ULTRA
ULTRA
RUN TIME ADJUSTMENT
PRESS UNLOCK BUTTON TO CHANGE TO 4 MINUTES. PRESS START BUTTON TO CHANGE TO 45 MINUTES. PRESS STATUS TO EXIT.
TEMP START ADJUSTMENT
TO ENTER PROGRAM MODE
M-1234
PROGRAM
ULTRA
PRESS AND HOLD THE STATUS BUTTON ON THE REMOTE FOR 4 SECONDS. THE REMOTE WILL BEEP 3 TIMES THEN DISPLAY “PROGRAM” & “M-1234". PRESS TRUNK TO CONTINUE.
PRESS TRUNK TO GO TO TEMP ADJUSTMENT
ON
ON
TIMER
TEMP 1
PROGRAM
PROGRAM
ULTRA
ULTRA
*TEMP MODE IS TURNED ON OR OFF BY HOLDING THE LOCK AND START BUTTONS FOR 5 SECONDS. THE TEMP SENSOR MUST BE INSTALLED FOR THIS FEATURE TO OPERATE.
TEMP ADJUSTMENT
PRESS THE UNLOCK OR START BUTTONS TO SCROLL THROUGH THE SETTINGS. TEMP 1- THE SYSTEM WILL START AT 0C / 32F TEMP 2­TEMP 3­TEMP 4-
THE SYSTEM WILL START AT -5C / 23F THE SYSTEM WILL START AT -15C / 5F THE SYSTEM WILL START AT -25C / 13F

PAGE 21

PROGRAMMING
VALET / EMERGENCY OVERRIDE MODE
THIS FEATURE IS USED TO DEACTIVATE THE REMOTE START AND ALARM (ALARM MODELS ONLY) IF THE VEHICLE REQUIRES SERVICING OR IF THE REMOTE IS LOST OR DAMAGED WHILE THE ALARM IS IN ARMED STATE.
OWNERS MANUAL
95 SERIES
ACTIVATING VALET MODE/ EMERGENCY OVERRIDE.
ENTER THE VEHICLE THEN TURN THE IGNITION KEY TO THE ON POSITION. (LEAVE IN THE ON POSITION)
WITHIN 3 SECONDS PRESS AND HOLD THE VALET SWITCH FOR 8-15 SECONDS* *DEPENDS ON “VALET OPTIONS” PROGRAM OPTION.
THE HORN WILL CHIRP 5 TIMES AS CONFIRMATION THAT THE SYSTEM HAS ENTERED VALET/ EMERGENCY OVERRIDE MODE.
THE LCD WILL DISPLAY VALET AFTER A FUNCTION IS PREFORMED. THE LEDS ON THE ANTENNA WILL TURN ON SOLID.
ENTER THE VEHICLE THEN TURN THE IGNITION KEY TO THE ON POSITION. (LEAVE IN THE ON POSITION)
WITHIN 3 SECONDS PRESS AND HOLD THE VALET SWITCH FOR 8-15 SECONDS* *DEPENDS ON “VALET OPTIONS” PROGRAM OPTION.
THE HORN WILL CHIRP 2 TIMES AS CONFIRMATION THAT THE SYSTEM HAS EXITED VALET/ OVERRIDE MODE. EMERGENCY
THE LEDS ON THE ANTENNA WILL TURN OFF.
95 SERIES
OWNERS MANUAL
DIAGNOSTICS

PAGE 22

ALARM STATUS / DIAGNOSTICS
Diagnostic Mode is a tool that can help trouble shoot a start fault. If the remote starter fails to start i.e.: the hood is open the park likes will flash a diagnostic code. i.e.: 5 flashes = start attempt with hood open. If the vehicle does not remote start, count the park light flashes then compare it to the chart below.
PARK LIGHTS LED FLASHES DIAGNOSTICS / STATUS
3 SLOW FLASHES LED’s ON SOLID SYSTEM IS IN SERVICE MODE. 4 SLOW FLASHES SERIES OF 8 FLASHES NOT SET IN RESERVATION MODE “M” MODELS 5 SLOW FLASHES SERIES OF 5 FLASHES START ATTEMPT WHILE IGNITION IS ON
5 FLASHES SERIES OF 5 FLASHES START ATTEMPT WITH HOOD SWITCH OPEN 6 FLASHES SERIES OF 6 FLASHES START ATTEMPT WITH BRAKE APPLIED 7 FLASHES SERIES OF 7 FLASHES SYSTEM IS IN TACH LOCK OUT (SEE DEALER) 8 FLASHES SERIES OF 8 FLASHES THREE START ATTEMPTS WITH NO START
The start fault must be corrected in order for the system to operate correctly. See your dealer for additional trouble shooting or visit and visit the support page..www.ultrastarters.com
TROUBLE SHOOTING
When I press the start button the vehicle acts like it is going to start but does not?
This issue is most common to a problem with the bypass module. Bypass modules turn your factory security off so that the remote starter can start the vehicle. Have your dealer reprogram the bypass module to the vehicle.
When I unlock the doors the windows roll down or the Trunk Pops?
This issue is caused by the length of the unlock pulse. To correct this issue program the system for short door lock pulses. (125ms)
The alarm activates 30-45 minutes after setting it?
To prevent the vehicles battery from going dead the computer will "hibernate" like your home computer might. In some vehicles this causes the door pin input to change state. The alarm detects the change of state and activates. A relay must be installed to isolated the door pin circuit from the alarm.
The starter motor stays engaged to long when remote started?
Reset then relearn the Tach with the transmission in reverse. If the vehicle is tach learned when the idle is high the starter motor may "drag". Check your ground connection if issues persist.

PAGE 23

WARRANTY
OWNERS MANUAL
95 SERIES
WARRANTY
Applicated Security Technologies, Inc. ("AST") promises to the original purchaser to repair or replace with a comparable reconditioned model any AST control module ("module") excluding without limitation the any other accessories, including but not limited to the antenna, remote, siren and wiring harness, proves to be defective in workmanship or material under reasonable use during the lifetime of the vehicle it was originally installed, provided the following conditions have been met: the module was professionally installed and serviced by an authorized AST dealer; the unit will be professionally reinstalled in the vehicle in which it was originally installed by an authorized AST dealer; the warranty information card was sent to AST within 10 days of the original installation date. Any warranty returns include a warranty return authorization number issued by AST, original bill or sale and be pre-paid shipped directly to AST. After an initial period of 2 years from the date of installation, AST reserves the right, at its sole discretion, to charge a warranty processing fee of $30.00 USD. AST does not cover the cost for return freight on warranty items, this cost is the sole responsibility of the purchaser.
All components included with the original packaged unit other than the module, including but not limited to the siren, antenna and the remote transmitters, carry a one-year warranty from the date of purchase of the same. Any warranty returns on components must include a warranty return authorization number issued by AST, original bill or sale and be pre-paid shipped directly to AST. This warranty is non-transferable and is automatically void if: the original purchaser has not completed the warranty card and mailed it within ten (10) days of the date of purchase to the address listed on the card; the unit's date code or serial number is defaced, missing or altered; the unit has been modified or used in a manner contrary to its intended purpose; the unit has been damaged by accident, unreasonable use, neglect, improper service, installation or other causes not arising out of defects in materials or construction. The warranty does not cover damage to the unit caused by installation or removal of the unit. AST, at its sole discretion, will determine what constitutes excessive damage and may refuse the return of any unit with excessive damage, including, but not limited to, overloading, moisture and physical damage.
To the maximum extent allowed by law, any and all warranties are excluded by the manufacturer and each entity participating in the stream of commerce therewith. This exclusion includes but is not limited to, the exclusion of any and all warranty of merchantability and/or any and all warranty of fitness for a particular purpose and/or any and all warranty of non-infringement or patents, in the United States of America and/or abroad. Neither the manufacturer or any entities connected therewith shall be responsible or liable for any damages whatsoever, including but not limited to, any consequential damages, incidental damages, damages for loss of time, loss of earnings, commercial loss, loss of economic opportunity and the like. Notwithstanding the above, manufacturer does offer a limited warranty to replace or repair the control module as describe above.
Some states do not allow limitations on how long an implied warranty will last or the exclusion or limitation on how long an implied warranty will last or the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights, which vary State to State.
95 SERIES
OWNERS MANUAL

PAGE 24

Technical Support: support@ultrastarters.com
Additional Product Information: www.ultrastarters.com
IMPORTANT NOTES
LOCK, UNLOCK, DRIVER'S DOOR PRIORITY UNLOCK, TRUNK RELEASE AND THE AUXILIARY OUTPUTS ARE OPTIONAL OUTPUTS. ENABLING THESE FEATURES REQUIRES CUSTOM INSTALLATION & PROGRAMMING. THESE FEATURES MAY NOT BE COMPATIBLE WITH SOME VEHICLES.
FOR SAFETY REASONS THE TRUNK RELEASE OUTPUT WILL NOT ACTIVATE WHEN THE IGNITION IS IN THE ON POSITION.
NOTE: PADLOC AND 2ND CAR OPERATION ARE FEATURES THAT REQUIRE SPECIAL PROGRAMMING.
SOME FEATURES MAY NOT BE AVAILABLE FOR ALL APPLICATIONS. CONTACT YOUR DEALER FOR MORE INFORMATION.
Loading...