Ultra Faucets LTR10024 Owner Manual

Page 1
Z Collection
Two Handle Roman Tub Faucet with hand-shower and Rough-in Valve
Installation/Installation/Instalación
CUSTOMER SERVICE
TOLL-FREE 1-888-OK-ULTRA (658-5872)
UF65440 - Polished Chrome UF65443 - PVD Brushed Nickel UF65445 - Oil Rubbed Bronze UF65447 - Matte Black
Tools You Will Need / Outils dont vous aurez besoin / Herramientas necesarias
Adjustable Wrench
Clé à molette
Llave ajustable
Cinta selladora para rosca
Pipe Tape
Ruban pour tuyau
Phillips Screwdriver
Tournevis cruciforme
Destornillador cruciforme
Groove join pliers
Pince multiprise
SAFETY TIPS
If you use soldering for the installation of the faucet, the seats, cartridges and washers will have to be removed before using flame. Otherwise, warranty will be void on those parts.
Cover your drain to avoid losing parts.
0~55.
CONSIGNES DE SÉCURITÉ
Si vous posez le robinet par brasage, il est essentiel de retirer les sièges, les cartouches et les rondelles avant d’appliquer la flamme, faute de quoi la garantie sur ces pièces sera annulée.
Couvrez le drain pour ne pas perdre des pièces.
0~55.
CONSEJOS DE SEGURIDAD
En el caso de utilizar soldadura para instalar el grifo, remueva los asientos, cartuchos y arandelas antes de usar la llama. De lo contrario, se anulará la garantía para esos componentes.
Tape la boca del desagüe para prevenir la pérdida de piezas pequeñas.
0~55.
Revised 4-2020
Page 2
Installation/Installation/Instalación
UF65440 UF65443 UF65445 UF65447
1 1
Remove the mud guard from the spout nipple-diverter assembly and unthread the diverter assembly.
4
2
2
3
Slide the spout nipple down into the spout hole and secure by threading on the washer and nut.
5
3
Re-attach the diverter assembly to the spout nipple.
6
Remove the mud guards from the hot and cold valves.
7
Teflon Tape
Apply teflon tape to the bottom outlet on the spout nipple-diverter assembly and attach the rough hand shower hose with washer.
Push the hot and cold valves up from the bottom and thread on the valve nuts from the top to secure the valves.
8
Remove the mud guard from the hand shower hose guide nipple and unthread the fixed assembly.
Teflon Tape
Apply teflon tape to the connector and attach hoses. If you have set the hot and cold valves more than 12” from the spout nipple-diverter assembly, please supply a code approved supply line.
9 1
Slide the hand shower hose guide nipple into the appropriate hole and secure by threading on the nut and washer. For optimum hand shower usage, it should be located no father than 24" from the spout.
Revised 4-2020
Page 3
Replacement Parts / Pièces de rechange / Repuestos
Part No.DescriptionNO.
1
Diverter Knob & Rod Asse
2
Deck Spout Set Screw & Allen Key
3
4
Handle Adaptor 9Q224700PL
Handle Base Assembly 9Q224800CP/AP/HA/HBW
5
Base Assembly 9Q224900CP/AP/HA/HBW
6
Aerator 5E0M0115PL
7
8
Base Assembly
9
Shower Base Assembly
10
11
Hand Shower Set Screw & Allen Key 9Q1349NT
12
Hot Valve Body Assembly 9Q225300NT
13
Spout Diverter Assembly 9Q225500NT
14
Cold Valve Body Assembly 9Q225400NT
mbly
9Q225000CP/AP/HA/HBW
9Q1350NT
5C0001500CP/AP/HA/HBW0Handle
9Q225200CP/AP/HA/HBW
9Q225100CP/AP/HA/HBW
5F0001400CP/AP/HA0Hand Shower
1
2
3
4
5
10
11
UF65440 UF65443 UF65445 UF65447
10
12
11
3
Teflon Tape
9
8
7
6
Slide the black nylon or finished hand shower hose into the hand shower hose guide nipple and attach to rough hand shower hose using teflon tape. For optimum hand shower usage it should be located no father than 24" from the spout.
Connect valve body to water supplies using the proper fittings.
12
Turn on water supply and check for leaks.
15
Hose 5G0M0191CP
16
Hose 5G0M0055CP
17
Diverter Assembly
51014144NC
12
13
14
15
16
17
13
Replace mud guards.
14
Installation completed.
Limited Lifetime Warranty
Ultra Faucets warrants to the original purchaser that its products will be free from defects in workmanship and materials. All Ultra Faucets are provided with a life time limited warranty. This warranty does not cover any other labor or service charges associated with the removal, repair, or reinstallation of Ultra Faucets products. This express warranty does not apply to products that have been damaged as a result of misuse, abuse, negligence, accident, faulty installation or maintenance practices and/or used in any manner contrary to those recommended by the manufacturer.
Need help? Please ca Besoin d’aide? Veuillez communiquer avec notre service à la clientèle au numéro gratuit 1-888-658-5872 pour tous renseignements
ou services complémentaires. ¿Requiere asistencia? Llame a nuestro Servicio al Cliente, sin costo, al 1-888-658-5872 para asistencia adicional o servicio.
ll our toll-free customer service line at 1-888-658-5872 for additional assistance or service.
Revised 4-2020
Revised 4-2020
Page 4
Installation/Installation/Instalación
UF65440 UF65443 UF65445 UF65447
15
Turn the water supply off and remove the mud guards.
18
16
Place the spout washer under the spout and install spout on spout nipple-diverter assembly. Be sure the spout is firmly resting on the deck. Secure the spout with the setscrew.
17
Insert diverter knob and rod assembly into the spout and thread the assembly onto the diverter rod in the spout diverter assembly. Pull the diverter rod and knob up and down to test the connection.
19 20
24
Leaving the water on, pull the hose to its farthest extension and point it into the tub. Pull the diverter knob to its top position. Flush the debris for one minute. Turn off the valves.
27
25
Attach the hand shower to the black nylon or finished hose.
26
Re-install the aerator with tool.
Insert the bush and screw into the hot valve. turning the
for cold valve.
Secure
screw
the assembly
clockwise. Repeat
by
21
Pull black nylon or finished hose through the hand shower nipple bracket. Slide the hand shower washer, bracket and hose guide over the hose. Secure the assembly with the setscrew. Note, make sure the hose does not slip under the deck.
Place the washer over the hot valve. Align the handle and place the handle and escutcheon assembly into the valve. Secure the assembly by turning the escutcheon clockwise. Repeat for cold valve.
22
Remove the aerator with tool. Turn the water supply on.
Remove the plastic cover.
23
Make sure the diverter knob is in the down position. Turn the faucet handles on full for one minute to flush debris.
Installation complete.
Revised 4-2020
Revised 4-2020
Loading...