Congratulations on the purchase of your new Ultima 250 air dental delivery unit. Our goal at
Ultima Dental Systems is to provide the veterinarian with the finest dental products and the best
customer support available in the industry. All of our equipment is built with a close attention to
detail and a strong passion for quality.Ultima Dental Systems has specialized in dental air
equipment exclusively for veterinarians since 1984 when we introduced the first veterinarian
dental unit. We have offered quality products and services for nearly three decades, we are the
originators. So you can rest assured that you have purchased the finest veterinary dental
Equipment available in the world today.
The Ultima 250 series of dental air delivery units were designed with the veterinarian in mind.
Ultima Dental Systems offers the Ultima 250 series in two different models, both models are
extremely sleek, compact, and versatile units, built with attention to detail and Ultima’s
relentless passion for quality. The Ultima 250 Table-top is perfect for small clinics with minimal
work space, mobile clinics on the go, and also as a second unit in many practices. The fact that
the unit can connect to any air source, whether compressed air or nitrogen not only makes the
Ultima 250 series versatile, but very easy to use with quick disconnect fittings. The quick
disconnect fittings allows the user to disconnect the unit at a moment’s notice. The Ultima 250
Arm units can practically be mounted anywhere, on a wall, fixed to an anesthesia pole, inside
cabinets, under wet tables; the different custom possibilities are endless. The Ultima 250 Series
line of units is built to withstand the test of time.
*Your Ultima 250 unit has been set up, tested, and operated by the manufacturer to ensure
the highest level of quality.
1 | P a g e
www.UltimaDentalSystems.com
Ultima 250 Owner’s Manual Table-Top & Arm Units
Table of Contents
1. Set-Up and Installation…………………………………………………… Page 3-5
2. Ultima 250 Operation………………………………………………………Page 6-8
3. General Trouble Shooting………………………………………………... Page 9-14
Under and inside the units’ removable top are two male quick disconnect fittings one with shutoff and one without, along with Suction feet for the table-top unit. Un-screw the sliver thumb
screw located at the top of the unit. The two suction feet provided are to ensure more stability
for the unit on a table top surface, even if the water bottles are empty. To make a more
permanent installation in a particular location, simply screw in the unit to a flat surface.
Ultima 250 Arm Wall/Pole Mount
WALL MOUNT
When installing the wall mount for the Ultima 250 Arm unit, it is best if the wall mount is screwed
into and secured to a wall beam. Use a stud finder, which can be found in most hardware
stores, to locate a beam in the area the Ultima 250 will be installed. However, if this is not
possible a second option is to use Drywall mollies to secure the wall mount, preferably the
butterfly type that spring open behind the Drywall for extra holding power. Once the wall mount
has been secured, install the extension arm, followed by the unit. Then connect the air source to
the unit.
Wall Mount Re-Order # UD-105-018-BS
www.UltimaDentalSystems.com
3 | P a g e
Ultima 250 Owner’s Manual Table-Top & Arm Units
POLE MOUNT
When installing the pole mount be sure you have the right size pole mount for the pole you are
connecting it to. The pole mounts are available in two sizes 1 ¾” and 2”. On the pole mount
there are two Allen screws, one on either side of the mount. Simply, un-screw the Allen screws
to open the pole mount. Place the mount around the pole and Re-attach the other half, tighten
the screws on the pole mount until tight and secure. Once the pole mount has been secured,
install the extension arm, followed by the unit. Then connect the air source to the unit.
1 ¾ Inch Pole Mount Re-Order # UD-105-126-BS
2 Inch Pole Mount Re-Order # UD-105-051-BS
Both Units include a standard 12” arm attachment. Ultima Dental Systems also has available 6”,
8”, 10” and 16” arm attachments. The Ultima 250 Arm units make it possible to connect to as
many arm attachments as needed to achieve the correct length necessary for any practice
environment. To order additional arm attachments contact the local distributor in your area or
call The UDS Support team directly at: (954) 772-9779
www.UltimaDentalSystems.com
4 | P a g e
Ultima 250 Owner’s Manual Table-Top & Arm Units
Set-Up and Installation
Air Source
COMPRESSED AIR
To begin working with the Ultima 250 dental unit using an air compressor, you will need ¼
outside diameter tubing, this can be purchased at any local hardware store. Cut the ¼” tubing to
the length needed between the compressor and where the unit will be used. Connect the male
quick disconnects provided with the unit to the ¼” tubing, connect the male quick disconnect
without shut-off to the compressor. Run the tubing to the unit from the compressor and connect
the male quick disconnect with shut off to the female disconnect on the side of the unit labeled
Filtered Air In. Set the air pressure from the compressor or nitrogen tank to 65/70 Psi. NEVER
EXCEED 80 Psi GOING INTO THE UNIT!
Male Qucik Disconnect W/Shut off valve Male Qucik Disconnect Without/Shut off valve
PART # UD-1070-AS-PW PART# UD-P1069-PW
*If you are using a compressor that is not an Ultima Silent-Surge compressor then additional
parts and fittings may be required such as the Female quick disconnect fitting. For additional
parts contact your local distributor or UDS Technical Support: (954) 772-9779
NITROGEN
To begin working with the Ultima 250 dental unit using nitrogen, you will need ¼ outside
diameter tubing. Cut the ¼” tubing to the length needed between the nitrogen source and the
location the unit will be used. Connect the male quick disconnects provided with the unit to the
¼” tubing, connect the male quick disconnect without shut-off to the nitrogen source. Run the
tubing to the unit from the nitrogen source and connect the male quick disconnect with shut off
to the female disconnect on the side of the unit labeled Filtered Air In. Set the air pressure from
the nitrogen source to 70 Psi. NEVER EXCEED 80 Psi GOING INTO THE UNIT!
* If you are using a nitrogen regulator not provided by Ultima Dental Systems then additional
hardware may be required to install the unit. Contact your local gas company for Nitrogen Etanks and refills.
www.UltimaDentalSystems.com