Relays
Thermistor Location
Task Touch Touch Display Comments
Adjust Set-point
View Actual Temp
(Thermistor 1)
View Actual Temp
(thermistors 2 - 4)
Service Mode
Relay Status
V
V
V
or or Flashing
V V
V
Hold 5
Hold 5
V
Hold
Hold
V
Scrolls Thermistors
Use the up or down
V
ºF
38º
2 - 4
0
31 30
Use the up and down arrows to adjust
arrows to scroll
Relay number 3 (comp) with 1 (on) or 0 (off)
Programming the board for a CLRCO2175
1 Unit must be plugged in
The display may show a SP or - -
2
either is OK Install a jumper on J3
3
Hold down warmer, colder and
4
light button until display shows 2 digits and the main board beeps
Use warmer/colder to select
5
model (68 = CLRCO2175)
To access the error codes, go into the service mode and arrow up to # 3 Touch light bulb icon to see the codes
Error Code Description E1 E2 E3 E5 E6
Thermistor #1 open Thermistor #1 shorted Door left open T 1 out of range +10º T 1 out of range -10º
Press and release light key
6
Wait for display to stop flashing
7
Remove jumper from b oard
8
Unplug unit and wait 5 seconds
9
Plug unit back in
10
J3 Plug
Jump these 2 pins
Trouble Shooting
Check for error codes
Unplug unit and plug back in. If the main board beeps when plugging in the unit it is probably not a board issue.
No Ice
Check Water Supply.
Check refrigerator temperature - must be at 42º or set point to
make ice.
Check bin temperature - at 34º the unit stops making ice it must
get above 35º to start again.
Check drain system.
Check circulation pump
Refrigerator too warm
Check the actual refrigerator temperature. If set to 38ºF the actual
temperature should be between 36ºF and 40ºF during normal operation.
Check door seal.
Check installation.
Set control colder.
E7 E8 E9 E10 E11 P1
FF7.5HBK p/n 70078-S
Voltage 115.0 Frequency 60.0 LRA 25.0 FLA 4.0 Start Winding 11.2 Run Winding 2.2
Water Valve 275 Ohms
Bypass Coil 300 Ohms
Pump Motor 72 Ohms
Refrigeration Coil 150 Ohms
White Thermistor 5,000 Ohms
Black Thermistor
T 2 open or shorted T 3 open or shorted T 4 open or shorted Top drawer left open EE Memory Error Pump Circuit open
Compressor
10,000 Ohms
Loading...