INSERT PANEL GUIDE
Door & Drawer Insert Panel Guide
Refrigerators
U-1115RB-00
U-1175RB-00
U-1175RB-02
U-1175RW-00
U-1175RW-02
U-2115RB-00
U-2115RW-00
U-2175RCB-00
Combo® Models
U-2175RFB-00
U-2175RFW-00
U-C2275DWROL-00
U-CLRCO2175B-00
U-CLRCO2175B-40
U-CO1175B-00
U-CO1175B-20
U-CO2175FB-00
Ice Makers
U-ADA15IMB-00
U-BI2115B-00
U-B12115B-20
U-B12115W-00
U-B12115W-20
U-CLR2160B-00
U-CLR2160B-40
U-CLR2160W-00
Freezers
ULN-75FB-00
ULN-75FWH-00
U-2175RCB-02
U-2175RCW-00
U-2175RCW-02
U-2275DWRCOL-00
U-2275DWRCOL-02
U-ADA24RB-13
ULN-29RB-00
ULN-29RB-02
ULN-29RB-06
ULN-29RB-09
ULN-29RWH-00
ULN-29RWH-02
ULN-29RWH-06
ULN-29RWH-09
U-CO2175FW-00
U-CO29B-00
U-CO29B-03
U-CO29B-20
U-CO29FB-00
U-CO29FWH-00
U-CLR2160W-40
ULN-BI95B-00
ULN-BI95B-20
ULN-BI95BTP-00
ULN-BI95BTP-20
ULN-BI95WH-00
ULN-BI95WH-20
ULN-SP18B-03
ULN-SP18B-20
ULN-SS98-03
ULN-SS98-20
The American Built-In Undercounter Leader Since 1962
U-LINE.COM
Safety Precautions
Panel Dimensions
The insert panel must not weigh more than 20 lbs.
Safety Alert Definitions
Throughout this guide are safety items labeled with a Danger,
Warning or Caution based on the risk type:
Danger means that failure to follow this safety statement will
result in severe personal injury or death.
Warning means that failure to follow this safety
statement could result in serious personal injury or
death.
Caution means that failure to follow this safety statement
may result in minor or moderate personal injury, property
or equipment damage.
Insert Panel Installation
Custom 1/4'' Thick Door/Drawer Panel
Insert
Insert Panel Preparation
A custom insert panel may be inserted into the door / drawer
frame. Custom insert panels can be flat or raised, as long as the
maximum panel thickness, where inserted into the door / drawer
reveal (channel), is no more than 1/4" thick. For raised panels, the
depth of the reveal is 1/4" on all four sides.
Model Width Height
1115R 13-15/16" 26-15/16"
1175R 22-15/16" 26-15/16"
2115R / BI2115 14-1/32" 27-11/16"
2175RC / 2175RF 23-1/32" 27-11/16"
*2275DWRC / *C2275DWR 23-1/32" 12-15/32"
29R / CO29 / CO29F 19-13/16" 21-13/32"
75F 22-15/16" 26-15/16"
ADA15IM 13-15/16" 26-15/16"
ADA24R 22-15/16" 26-15/16"
BI95 / BI95BTP / SP18 12-15/16" 13-15/32"
BI98 / SS98 13-15/16" 15-15/16"
CLR2160 14-1/32" 27-11/16"
CLRCO2175 / CO2175F 23-1/32" 27-11/16"
CO1175 22-15/16" 26-15/16"
* The overlay model is used to create a black model which can be used
with 1/4" insert panels (with the necessary purchase of two handle kits).
Insert Panel Installation
Door Models
1a. Remove top hinge screw pin with
Phillips head screwdriver. Remove
door by tilting forward and lifting off
bottom hinge pin.
Drawer Models
1b. Drawer model inserts can be installed without removing the
drawer from the unit. Simply pull the drawer open and follow
instructions.
Custom raised panels will reduce the door’s 90° swing if
the unit is installed next to a wall or similar type of
structure.
2. Pull door / drawer gasket out of groove
(top edge of door / drawer only). Start in
the middle and pull outward, moving
toward the edge. This may take some
force.
3. Remove the two outside screws, one on
each side, holding door / drawer handle.
Slightly separate handle from door /
drawer.
4. Pull handle up and off.
u-line.com 1