U-Line SS1095FD, SS1095FC, SS1095NF User Manual

Installation Guide
SS1095 Ice Maker
www.U-LineService.com
Phone (414) 354-0300 • FAX (414) 354-7905
Service & Parts Tech Lines Phone (800) 779-2547 • FAX (414) 354-5696
OnlineService@U-Line.com
©2008 U-Line Corporation
09/2008
SS1095
MARINE SERIES
Contents
Follow Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Alert Definitions . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Inspect and Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Tools/Materials Required . . . . . . . . . . . . . . . . . . . . . . . . 3
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Prepare Site. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cut-Out Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Product Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Door Swing/Clearances Information . . . . . . . . . . . . . . . 7
Reversing the Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Other Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . 9
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Environmental Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Adjust Door. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Checking Door Alignment . . . . . . . . . . . . . . . . . . . . . . . 10
Prepare Plumbing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Water Supply Connection . . . . . . . . . . . . . . . . . . . . . . . 10
Prepare Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Level the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Leveling Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Install the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installation of the Unit. . . . . . . . . . . . . . . . . . . . . . . . . . 12
Grille Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installation Troubleshooting . . . . . . . . . . . . . . . . . . . . . 13
Start-Up for the First Time . . . . . . . . . . . . . . . . . . . . . . . 13
Initial Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Start-Up Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 14
Who To Call. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1 Follow Safety Precautions
IMPORTANT
PLEASE READ all instructions completely before attempting to install or operate the unit.
• This unit requires connection to the water supply. Improper hook-up can result in substantial property damage! If you are unsure of your ability to safely connect the water supply to the unit, consult a licensed plumber for assistance.
• This unit requires connection to a grounded (three­prong), polarized receptacle that has been placed by a qualified electrician in accordance with applicable electrical codes.
Safety Alert Definitions
Safety items throughout this guide are labeled with a Danger, Warning or Caution based on the risk type:
DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury, or death.
CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
www.U-LineService.com 2 09/2008
MARINE SERIES
SS1095
General Precautions
Use this appliance for its intended purpose only and follow these general precautions along with those listed throughout this guide:
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Keep the unit unplugged throughout installation except during testing.
• Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the unit.
• Always keep your working area dry.
CAUTION
• Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges.
• Do not lift the unit by the door or door handle.
• Do not install the unit behind closed doors or in any way that would obstruct airflow to the front grille, which may cause the unit to malfunction.
2 Inspect and Plan
You have received a carton containing your SS1095 Ice Maker with a package inside containing a User Manual, a Product Registration Card and water connection parts. Complete and mail the Product Registration Card or register online at www.U-LineService.com. Once your unit is installed, keep the User Manual and this Installation Guide in a safe place for future reference.
Please carefully follow the directions that apply to your unit and your intended design.
Tools/Materials Required
• Screwdrivers — slotted and Phillips head
• 1/4-inch OD copper tubing and shut-off valve for water supply line
• 1/4-inch thick door panel material and cutting tools
IMPORTANT
A complete water hook up kit is available for purchase from your dealer. Order U-Line Part No. WATERHOOKUP.
Inspection
Unwrap and inspect the unit on a flat, level surface capable of supporting its entire weight.
09/2008 3 www.U-LineService.com
SS1095
MARINE SERIES
3 Prepare Site
Your U-Line product has been designed for either free­standing or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must NOT be obstructed and clearance is required for water and electrical connections in the rear.
Note: Unit can NOT be installed behind a closed cabinet door.
Cut-Out Dimensions
IMPORTANT
It is extremely important that the unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly.
Filler Panel (Not Provided by U-Line) –
May Be Added Above or Below Unit
to Enclose for a Built-In Look
Typical
Counter
Height
34-1/4"
to
35-1/8"
Cut-Out
Height
24-7/8"
to
25"
15-7/8" Minimum
See Electrical
Specifications
for Power Supply
8"
14-3/8"
Model SS1095FC: Follow the cut-out drawing in (Figure
2). The unit must sit in a frame structure with a frame
thick enough to accommodate mounting the flange to its sides and top, and a base high enough to align the door with other cabinet doors. Make the frame width 14-1/6” and the height 24-3/4”. This will allow for ease in installation and removal of the unit for servicing. 16” depth includes the water line connection.
Note: If you purchase a U-Line WATERHOOKUP kit, the minimum depth required to install the unit is 15-1/4”. The recommended receptacle location is an adjacent cabinet. If receptacle will be behind unit, additional space is required.
Filler Panel (Not Provided by U-Line) –
Needed to Attach Mounting Flange on Unit
16" Minimum
Cut-Out
Height
24-3/4"
3/4"
Minimum Flange
Mounting Area
See Electrical
Specifications
for Power Supply
14-1/16"
Cut-Out Width
15-3/16"
Minimum Opening
8" Height
From Floor
Toe Kick
Figure 2
Figure 1
Model SS1095NF: Follow the cut-out drawing in (Figure
1). The 14-3/8" width allows 1/4" for ease in installation
and removal of the unit. 15-7/8" depth includes the water line connection.
Note: If you purchase a U-Line WATERHOOKUP kit, the minimum depth required to install the unit is 15-1/8”. The recommended receptacle location is an adjacent cabinet. If receptacle will be behind unit, additional space is required.
www.U-LineService.com 4 09/2008
MARINE SERIES
Model SS1095FD: Follow the cut-out drawing in (Figure
3). The unit must sit in a frame structure with a frame
thick enough to accommodate mounting the flange to its sides and top, and a base high enough to align the door with other cabinet doors. Make the frame width 14-5/8” and the height 24-3/4”. This will allow for ease in installation and removal of the unit for servicing. 18-3/8” depth includes the door and water line connection.
Note: If you purchase a U-Line WATERHOOKUP kit, the minimum depth required to install the unit is 17-5/8”. The recommended receptacle location is an adjacent cabinet. If receptacle will be behind unit, additional space is required.
SS1095
Filler Panel (Not Provided by U-Line) –
Needed to Attach Mounting Flange on Unit
18-3/8" Minimum
Cut-Out
Height
24-3/4"
See Electrical
Specifications
for Power Supply
8" Height
From Floor
3/4"
Minimum Flange
Mounting Area
Figure 3
14-5/8"
Cut-Out Width
16-1/8"
Minimum Opening
Toe Kick
09/2008 5 www.U-LineService.com
Loading...